| Hardwaretype | list | 000A00000047 |
| Müll | list | disabled |
| ETS_Download_I | unsignedInt 0…255 | 1 |
| ETS_Download_II | unsignedInt 0…255 | 1 |
| Objekte | list | disabled |
| Objekte 2 | list | disabled |
| Setting of channel parameters | list | each channel individual |
| Dimmer-Kanal 1 verwenden? | list | Yes |
| Dimmer-Kanal 2 verwenden? | list | Yes |
| Dimmer-Kanal 3 verwenden? | list | Yes |
| Dimmer-Kanal 4 verwenden? | list | Yes |
| Wirkungsweise Kanal 1 | list | Output 1 (max. 250W) |
| Wirkungsweise Kanal 2 | list | Output 2 (max. 250W) |
| Wirkungsweise Kanal 3 | list | Output 3 (max. 250W) |
| Wirkungsweise Kanal 4 | list | Output 4 (max. 250W) |
| Verzögerung nach Busspannungswiederkehr | list | enabled |
| Verzögerungszeit
Stunden (0...23) | unsignedInt 0…59 | 0 |
| Delay time
Minutes (0...59) | unsignedInt 0…59 | 0 |
| Delay after bus voltage return
Minutes (0...59) | unsignedInt 0…59 | 0 |
| Delay time
Secondes (0...59) | unsignedInt 0…59 | 0 |
| Seconds (0...59) | unsignedInt 0…59 | 0 |
| Verzögerungszeit
Millisekunden (0...99) | unsignedInt 0…99 | 0 |
| Central function ? | list | No |
| Central object polarity | list | 0 = deactivated; 1 = activated |
| Blinking rate | list | 1 sec |
| Time for cycl. transm. of the feedback
Hours (0...23) | unsignedInt 0…23 | 0 |
| Minutes (0...59) | unsignedInt 0…59 | 2 |
| Seconds (10...59) | unsignedInt 10…59 | 10 |
| Millisekunden (0...99) | unsignedInt 0…99 | 0 |
| Time for cycl. transm. of operat. hours
Hours (0...23) | unsignedInt 0…23 | 23 |
| Minutes (0...59) | unsignedInt 0…59 | 0 |
| Manual control in case of bus voltage
failure | list | enabled |
| Manual control during bus operation | list | enabled |
| Disabling function ? | list | No |
| Polarity of disable object | list | 0 = enabled; 1 = disabled |
| Transmit status ? | list | No |
| Status object function and polarity | list | 0 = inactive; 1 = manual control active |
| Behaviour at the end of permanent
manual control during bus operation | list | no change |
| Bus control of single channels during
bus operation can be disabled? | list | No |
| Kanalfunktion | list | Dimmer |
| Art der angeschlossenen Last | list | universal (with automatic calibration procedure) |
| Type of connected load | list | universal (with automatic calibration procedure) |
| Operation with
Universal power booster ? | list | No |
| Definition of the
brightness range | list | with basic brightness |
| Minimum brightness | list | 1% |
| Minimalhelligkeit | list | 1 |
| Basic brightness | list | Level 2 |
| Maximum brightness | list | 100% |
| Behaviour after ETS programming | list | No reaction |
| Ver_ETS_Download | list | Value |
| Ver_ETS_DownloadWert | unsignedInt 0…255 | 51 |
| Behaviour in case of bus voltage failure | list | No reaction |
| Ver_ETS_Download | list | switch off |
| Ver_ETS_DownloadWert | unsignedInt 0…255 | 255 |
| Behaviour after bus or
mains voltage return | list | Brightness value before bus voltage failure |
| Ver_ETS_DownloadWert | unsignedInt 0…255 | 89 |
| Switch-on brightness | list | 100% |
| Einschalth_Download | list | Value |
| Einschalth_DownloadWert | unsignedInt 0…255 | 102 |
| Freigabe Einschaltdrehzahl
(Nur bei Dimmaktor 1fach!) | list | No |
| Cutting-in speed | list | 100% |
| Einschalth_DownloadWert | unsignedInt 0…255 | 255 |
| Verweildauer in Einschaltdrehzahl
Stunden (0...23) | unsignedInt 0…23 | 0 |
| Verweildauer für Einschaltdrehzahl
Stunden (0...23) | unsignedInt 0…23 | 0 |
| Verweildauer für Einschaltdrehzahl
Minuten (0...59) | unsignedInt 0…59 | 0 |
| Verweildauer in Einschaltdrehzahl
Minuten (0...59) | unsignedInt 0…59 | 0 |
| Dwell time in cutting-in speed
Seconds (0...59) | unsignedInt 0…59 | 2 |
| Dwell time for cutting-in speed
Seconds (0...59) | unsignedInt 0…59 | 2 |
| Milliseconds (5...9 * 100) | unsignedInt 5…9 | 5 |
| Dimming behaviour after receipt
of a brightness value | list | dimming to |
| Zeit für Dimmen über Fading
Stunden (0...23) | unsignedInt 0…23 | 0 |
| Zeit für Dimmen über Fading
Minuten (0...59) | unsignedInt 0…59 | 0 |
| Time for brightness value via fading
Seconds (0...59) | unsignedInt 0…59 | 20 |
| Zeit für Dimmen über Fading
Sekunden (0...59) | unsignedInt 0…59 | 20 |
| Zeit für Dimmen über Fading
Millisekunden (0...99) | unsignedInt 0…99 | 0 |
| Behaviour when OFF by
relative dimming | list | Dimming up switches channel ON (Standard) |
| Assignment to central function ? | list | No |
| Feedback telegrams | list | disabled |
| Time delays | list | disabled |
| Staircase function | list | disabled |
| Switch-on/switch-off behaviour | list | disabled |
| Scene function | list | disabled |
| Operating hours counter | list | disabled |
| Freigabe | list | not enabled |
| Signal short-circuit ? | list | No |
| Signal load failure / overload ? | list | No |
| Signal load type ? | list | No |
| Feedback switching status ? | list | No feedback |
| Updating the object value
for switching status feedback | list | only if the feedback value changes |
| Time delay for feedback telegram
after bus voltage return? | list | Yes |
| Cyclical transmission of the
feedback ? | list | No |
| Feedback brightness value ? | list | No feedback |
| Updating the object value
for brightness value feedback | list | only if the feedback value changes |
| Time delay for feedback telegram
after bus voltage return? | list | No |
| Selection of time delay | list | no time delay |
| Ausschaltverz_00 | unsignedInt 0…4294967295 | 0 |
| Einschaltverz_00 | unsignedInt 0…4294967295 | 0 |
| Einschaltverzögerung
Stunden | unsignedInt 0…23 | 0 |
| Switch-on delay
Minutes (0...59) | unsignedInt 0…59 | 0 |
| Ausschaltverzögerung
Stunden | unsignedInt 0…23 | 0 |
| Switch-off delay
Minutes (0...59) | unsignedInt 0…59 | 0 |
| Seconds (0...59) | unsignedInt 0…59 | 10 |
| Millisekunden | unsignedInt 0…99 | 0 |
| Switch-on delay retriggerable ? | list | No |
| Switch-off delay retriggerable ? | list | No |
| Treppenhausfnkt_00 | unsignedInt 0…4294967295 | 0 |
| Staircase time
Hours (0...23) | unsignedInt 0…23 | 0 |
| Minutes (0...59) | unsignedInt 0…59 | 3 |
| Staircase time retriggerable ? | list | No |
| Reaction to OFF-telegram | list | switch off |
| Supplementary function for
staircase function | list | No supplementary function |
| Freigabe_Zeitverlängerung | unsignedInt 0…255 | 0 |
| Einschaltzeit über Objekt
einstellbar ? | list | Yes |
| Zeitverlängerung der Einschaltzeit ? | list | No |
| Staircase function activatable via
"Staircase time" object ? | list | No |
| Maximum time extension | list | 1-fold time |
| Reaction at the end of
the staircase time | list | switch off |
| Vorwarnzeit_gesperrt | unsignedInt 0…4294967295 | 0 |
| Vorwarnzeit
Stunden ($FF) | unsignedInt 0…255 | 255 |
| Vorwarnzeit
Stunden (0...23) | unsignedInt 0…23 | 0 |
| Pre-warning time
Minutes (0...59) | unsignedInt 0…59 | 0 |
| Seconds (0...59) | unsignedInt 0…59 | 30 |
| Reduced brightness during the
pre-warning time (1...100 %) | unsignedInt 1…100 | 50 |
| Reduced brightness for
continuous lighting (1...100 %) | unsignedInt 1…100 | 50 |
| Soft ON function ? | list | No |
| Zeit für Dimmschritt Soft-EIN
Stunden (0...59) | unsignedInt 0…23 | 0 |
| Minuten (0...59) | unsignedInt 0…59 | 0 |
| Time for soft ON dimming increment
Seconds (0...59) | unsignedInt 0…59 | 0 |
| Milliseconds (1...99 * 10) | unsignedInt 1…99 | 1 |
| Millisekunden (0...99 * 10) | unsignedInt 0…99 | 0 |
| Soft OFF function ? | list | No |
| Time for soft OFF dimming increment
Seconds (0...59) | unsignedInt 0…59 | 0 |
| Automatic switch-off if a
brightness is undershot ? | list | No |
| Switch-off if brightness value
is smaller than | list | 5% |
| Delay time until switching off
Hours (0...23) | unsignedInt 0…23 | 0 |
| Delay scene recall ? | list | No |
| Verzögerungszeit
Stunden (0...23) | unsignedInt 0…23 | 0 |
| Szenenstatus
(Wird später ausgeblendet!) | list | no scene status |
| Behaviour when recalling a scene | list | Dimming to brightn. value via dimming increm. time |
| Fading time (0...240 s) | unsignedInt 0…240 | 2 |
| Dimming increment time (0...255 ms) | unsignedInt 0…255 | 5 |
| Overwrite values stored in the device
during ETS download ? | list | Yes |
| Scene 1 activatable by scene number
(scene number "0" = scene deactivated) | unsignedInt 0…64 | 1 |
| Brightness value for scene 1 | list | 100% |
| Storage function for scene 1 ? | list | No |
| Scene 2 activatable by scene number
(scene number "0" = scene deactivated) | unsignedInt 0…64 | 2 |
| Brightness value for scene 2 | list | 90% |
| Storage function for scene 2 ? | list | No |
| Scene 3 activatable by scene number
(scene number "0" = scene deactivated) | unsignedInt 0…64 | 3 |
| Brightness value for scene 3 | list | 80% |
| Storage function for scene 3 ? | list | No |
| Scene 4 activatable by scene number
(scene number "0" = scene deactivated) | unsignedInt 0…64 | 4 |
| Brightness value for scene 4 | list | 70% |
| Storage function for scene 4 ? | list | No |
| Scene 5 activatable by scene number
(scene number "0" = scene deactivated) | unsignedInt 0…64 | 5 |
| Brightness value for scene 5 | list | 60% |
| Storage function for scene 5 ? | list | No |
| Scene 6 activatable by scene number
(scene number "0" = scene deactivated) | unsignedInt 0…64 | 6 |
| Brightness value for scene 6 | list | 50% |
| Storage function for scene 6 ? | list | No |
| Scene 7 activatable by scene number
(scene number "0" = scene deactivated) | unsignedInt 0…64 | 7 |
| Brightness value for scene 7 | list | 40% |
| Storage function for scene 7 ? | list | No |
| Scene 8 activatable by scene number
(scene number "0" = scene deactivated) | unsignedInt 0…64 | 8 |
| Brightness value for scene 8 | list | 30% |
| Storage function for scene 8 ? | list | No |
| Type of counter | list | Up-counter |
| Limiting value specification ? | list | No |
| Start value preset ? | list | No |
| Limit value (1...65535 h) | unsignedInt 1…65535 | 65535 |
| Start value (1...65535 h) | unsignedInt 1…65535 | 65535 |
| Automatic transmitting of the
counter value | list | after change by interval value |
| Count value interval (1...65535 h) | unsignedInt 1…65535 | 1 |
| Selection of supplementary function | list | No supplementary function |
| Auswahl_SperrenZwang | list | Disabling function |
| Polarity of the disabling object | list | 0 = enabled; 1 = disabled |
| Behaviour at the beginning of the
disabling function | list | switch off |
| Brightness for forced position
"active, switch on" | list | 100% |
| Ver_AnfZw_Download | list | Value |
| Ver_AnfSp_Download | list | Value |
| Ver_AnfSp_DownloadWert | unsignedInt 0…255 | 255 |
| Ver_AnfZW_DownloadWert | unsignedInt 0…255 | 255 |
| Behaviour at the end of the
disabling function | list | tracked brightness value |
| Brightness for forced position
"active, switch off" | list | switch off |
| Ver_EndeSp_Download | list | tracked value |
| Brightness for forced position end
"inactive" | list | tracked brightness value |
| Ver_EndeSp_DownloadWert | unsignedInt 0…255 | 255 |
| Behaviour after
bus voltage return | list | No forced position |
| Logic operation function ? | list | No |
| Type of logic operation function | list | OR |
| Obj. value of logic operation obj.
after bus voltage return | list | 0 (OFF) |
| Obj. value of logic operation obj.
after ETS download | list | 0 (OFF) |
| Characteristic curve | list | linear |
| 1rd area: Time between two dimming
increments (1...255 ms) | unsignedInt 1…255 | 20 |
| Time between two dimming
increments (1...255 ms) | unsignedInt 1…255 | 20 |
| Brightness limiting value
1st / 2nd area (1…100 %) | unsignedInt 1…100 | 30 |
| Grenzwert 1. Bereich / 2. Bereich
(1...100 %) | unsignedInt 1…100 | 30 |
| 2rd area: Time between two dimming
increments (1...255 ms) | unsignedInt 1…255 | 10 |
| Brightness limiting value
2nd / 3rd area (1…100 %) | unsignedInt 1…100 | 60 |
| Grenzwert 2. Bereich / 3. Bereich
(1...100 %) | unsignedInt 1…100 | 60 |
| 3rd area: Time between two dimming
increments (1...255 ms) | unsignedInt 1…255 | 7 |
| Basic brightness | list | Level 5 (Standard halogen) |
| Ver_ETS_DownloadWert | unsignedInt 0…255 | 128 |
| Ver_ETS_DownloadWert | unsignedInt 0…255 | 166 |
| Ver_ETS_DownloadWert | unsignedInt 0…255 | 204 |
| Time for dimming via fading
Seconds (0...59) | unsignedInt 0…59 | 0 |
| Time for brightness value via fading
Seconds (0...59) | unsignedInt 0…59 | 0 |
| K1_Lastart LED Download | list | No LED load |
| Auswahl_SperrenZwang | list | Forced position function |
| Ver_EndeSp_Download | list | Value |
| Time between two dimming
increments (1...255 ms) | unsignedInt 1…255 | 10 |
| 1rd area: Time between two dimming
increments (1...255 ms) | unsignedInt 1…255 | 10 |
| 1. Bereich: Zeit zwischen zwei
Dimmschritten (1...255 ms) | unsignedInt 1…255 | 10 |
| Brightness limiting value 1st / 2nd area
(1…100 %) | unsignedInt 1…100 | 100 |
| Brightness limiting value
1st / 2nd area (1…100 %) | unsignedInt 1…100 | 100 |
| Helligkeits-Grenzwert
1. Bereich / 2. Bereich (1...100 %) | unsignedInt 1…100 | 100 |
| 2rd area: Time between two dimming
increments (1...255 ms) | unsignedInt 1…255 | 1 |
| Brightness limiting value 2nd / 3rd area
(1...100 %) | unsignedInt 1…100 | 100 |
| Brightness limiting value
2nd / 3rd area (1…100 %) | unsignedInt 1…100 | 100 |
| Helligkeits-Grenzwert
2. Bereich / 3. Bereich (1...100 %) | unsignedInt 1…100 | 100 |
| 3rd area: Time between two dimming
increments (1...255 ms) | unsignedInt 1…255 | 1 |
| Output 1 | list | Complete load of channel 1 (max. 300W) |
| Output 2 | list | Complete load of channel 2 (max. 300W) |
| Load channel 1 | list | max. 300W |
| Load channel 2 | list | max. 300W |