KNX Database
OURICAN MES-CFC-4 PRO MES-CFC-4 PRO

MES-CFC-4 PRO

OURICAN · Order number MES-CFC-4 PRO · Output › Actuator › Fan Controller

Download .knxprod MES-CFC-4 PRO 1.2 · 115 KB

Product

ManufacturerOURICAN
Product nameMES-CFC-4 PRO
Order numberMES-CFC-4 PRO
HardwareMES-CFC-4 PRO_Hw
MediumTwisted Pair
Bus current (mA)15
Rail mountedYes
Width (mm)208
RegistrationCertified · 2023-06-16
Languagesen-US
Catalog entryM-0260_H-SN2022.2D10.2D29-1_HP-0003-12-BE4D_CI-MES.2DCFC.2D4.20PRO-1
FingerprintBE4D
SHA-256e60cfa16f5b4df1ec06a0754f37fd8168deda8c1de82b0a9a91e1c9ddae69ab6
First seen2026-11-25
Markets13 markets

Application program: MES-CFC-4 PRO 1.2

Application number$0003
Version1.2
Mask versionMV-07B0 (System B)
KNX Data SecureNo
Minimum ETS version5.0
Parameters144
Group objects40
Group objects (40)
NoNameFunctionSizeDPTFlags
1FAN 1 ON/OFF0 = OFF, 1 = ON1 Bit1.1 switchCWT
2FAN 1 ON/OFF STATUS0 = OFF, 1 = ON1 Bit1.1 switchCRT
3FAN 1 SPEED VALUE (PERCENTAGE)0, 20%, 40%, 60%, 80%, 100%1 Byte5.1 percentage (0..100%)CWT
4FAN 1 SPEED STATUS (PERCENTAGE)0, 20%, 40%, 60%, 80%, 100%1 Byte5.1 percentage (0..100%)CRT
5FAN 1 INC/DEC 0 = DEC, 1 = INC1 Bit1.7 stepCWT
6FAN 2 ON/OFF0 = OFF, 1 = ON1 Bit1.1 switchCWT
7FAN 2 ON/OFF STATUS0 = OFF, 1 = ON1 Bit1.1 switchCRT
8FAN 2 SPEED VALUE (PERCENTAGE)0, 20%, 40%, 60%, 80%, 100%1 Byte5.1 percentage (0..100%)CWT
9FAN 2 SPEED STATUS (PERCENTAGE)0, 20%, 40%, 60%, 80%, 100%1 Byte5.1 percentage (0..100%)CRT
10FAN 2 INC/DEC 0 = DEC, 1 = INC1 Bit1.7 stepCWT
11FAN 3 ON/OFF0 = OFF, 1 = ON1 Bit1.1 switchCWT
12FAN 3 ON/OFF STATUS0 = OFF, 1 = ON1 Bit1.1 switchCRT
13FAN 3 SPEED VALUE (PERCENTAGE)0, 20%, 40%, 60%, 80%, 100%1 Byte5.1 percentage (0..100%)CWT
14FAN 3 SPEED STATUS (PERCENTAGE)0, 20%, 40%, 60%, 80%, 100%1 Byte5.1 percentage (0..100%)CRT
15FAN 3 INC/DEC 0 = DEC, 1 = INC1 Bit1.7 stepCWT
16FAN 4 ON/OFF0 = OFF, 1 = ON1 Bit1.1 switchCWT
17FAN 4 ON/OFF STATUS0 = OFF, 1 = ON1 Bit1.1 switchCRT
18FAN 4 SPEED VALUE (PERCENTAGE)0, 20%, 40%, 60%, 80%, 100%1 Byte5.1 percentage (0..100%)CWT
19FAN 4 SPEED STATUS (PERCENTAGE)0, 20%, 40%, 60%, 80%, 100%1 Byte5.1 percentage (0..100%)CRT
20FAN 4 INC/DEC0 = DEC, 1 = INC1 Bit1.7 stepCWT
22FAN 1 CYCLIC SPEED0 / 1 = CYCLIC SPEED1 Bit1.17 triggerCWT
23FAN 2 CYCLIC SPEED0 / 1 = CYCLIC SPEED1 Bit1.17 triggerCWT
24FAN 3 CYCLIC SPEED0 / 1 = CYCLIC SPEED1 Bit1.17 triggerCWT
25FAN 4 CYCLIC SPEED0 / 1 = CYCLIC SPEED1 Bit1.17 triggerCWT
26FAN 1 SPEED VALUE (0 to 5)0 TO 5 SPEED1 Byte5.100 fan stage (0..255)CWT
27FAN 1 SPEED VALUE STATUS (0 to 5)0 TO 5 SPEED1 Byte5.100 fan stage (0..255)CRT
28FAN 2 SPEED VALUE (0 to 5)0 TO 5 SPEED1 Byte5.100 fan stage (0..255)CWT
29FAN 2 SPEED VALUE STATUS (0 to 5)0 TO 5 SPEED1 Byte5.100 fan stage (0..255)CRT
30FAN 3 SPEED VALUE (0 to 5)0 TO 5 SPEED1 Byte5.100 fan stage (0..255)CWT
31FAN 3 SPEED VALUE STATUS (0 to 5)0 TO 5 SPEED1 Byte5.100 fan stage (0..255)CRT
32FAN 4 SPEED VALUE (0 to 5)0 TO 5 SPEED1 Byte5.100 fan stage (0..255)CWT
33FAN 4 SPEED VALUE STATUS (0 to 5)0 TO 5 SPEED1 Byte5.100 fan stage (0..255)CRT
34FAN 1 RELATIVE SPEED VALUE4-BIT VALUE4 Bit3.7 dimming controlCWT
35FAN 2 RELATIVE SPEED VALUE4-BIT VALUE4 Bit3.7 dimming controlCWT
36FAN 3 RELATIVE SPEED VALUE4-BIT VALUE4 Bit3.7 dimming controlCWT
37FAN 4 RELATIVE SPEED VALUE4-BIT VALUE4 Bit3.7 dimming controlCWT
38FAN 1 SCENESSCENES1 Byte17.1 scene numberCWT
39FAN 2 SCENESSCENES1 Byte17.1 scene numberCWT
40FAN 3 SCENESSCENES1 Byte17.1 scene numberCWT
41FAN 4 SCENESSCENES1 Byte17.1 scene numberCWT
Parameters (21)
ParameterTypeDefault
Speed ValuelistSpeed 0
Scene Number (0 = disabled)unsignedInt 0…640
Fan Speed ValuelistSpeed 0
CHANNEL 1listDisable
CHANNEL 2listDisable
CHANNEL 3listDisable
CHANNEL 4listDisable
Status for Cyclic Speedlist0...100 %
Status for Inc/Declist0...100 %
Status for Sceneslist0...100 %
Status for Relative Speedlist0...100 %
Status for On/Offlist0...100 %
Status for Push Buttonlist0...100 %
Relative SpeedlistDisable
Time interval between speedslist1 secs
ScenelistDisable
Type of Cyclic Speedlist0,1,2,3,4,5,4,3,2,1,0
Cyclic SpeedlistDisable
DelayunsignedInt 0…500
Status after Bus Voltage RecoverylistDisable
StartuplistDefault

Version history

ApplicationApp noFingerprintFirst seenSizeFile
MES-CFC-4 PRO 1.2 latest$0003BE4D2026-11-25115 KBDownload

About this file

This is the official ETS product database for the OURICAN MES-CFC-4 PRO (MES-CFC-4 PRO), published by the manufacturer in the KNX online catalog. To use it, open ETS, go to Catalogs → Import and choose the downloaded .knxprod file. The device then appears in your catalog and can be added to a project. Older versions are kept so existing projects can be matched to the application program they were commissioned with.

More from OURICAN

All OURICAN products