MK2007 DIN Rail 1ch Module MK2007
Moorgen Deutschland GmbH · Order number MK2007 · Light Control › Dimmer
Din Rail Dimmer 1 ch
Download .knxprod MK2007 DIN Rail 1ch Module 1.0 · 84 KB
Product
| Manufacturer | Moorgen Deutschland GmbH |
|---|---|
| Product name | MK2007 DIN Rail 1ch Module |
| Order number | MK2007 |
| Product text | Din Rail Dimmer 1 ch |
| Hardware | MK2007 DIN Rail 1ch Module |
| Medium | Twisted Pair |
| Bus current (mA) | 10 |
| Rail mounted | Yes |
| Registration | Registered · 2017-10-09 |
| Languages | en-US, fr-FR, it-IT |
| Catalog entry | M-01B9_H-MK2007-1-O006C_HP-030B-10-6188-O006C_CI-MK2007-2 |
| Fingerprint | 6188 |
| SHA-256 | e9a031152f9c0ccda66ad1679a618a0d46f07495a7fd674ab000e2766e733b2a |
| First seen | 2026-11-25 |
| Markets | 69 markets |
Application program: MK2007 DIN Rail 1ch Module 1.0
| Application number | $030B |
|---|---|
| Version | 1.0 |
| Mask version | MV-0021 (2.1) |
| KNX Data Secure | No |
| Minimum ETS version | 3.0 |
| Parameters | 231 |
| Group objects | 46 |
Group objects (46)
| No | Name | Function | Size | DPT | Flags |
|---|---|---|---|---|---|
| 0 | <Ch. 1> Switching (at once) | Off/On | 1 Bit | 1.1 switch | CW |
| 1 | <Ch. 2> Switching (at once) | Off/On | 1 Bit | 1.1 switch | CW |
| 2 | <Ch. 3> Switching (at once) | Off/On | 1 Bit | 1.1 switch | CW |
| 3 | <Ch. 1> Switching (smooth) | Off/On | 1 Bit | 1.1 switch | CW |
| 4 | <Ch. 2> Switching (smooth) | Off/On | 1 Bit | 1.1 switch | CW |
| 5 | <Ch. 3> Switching (smooth) | Off/On | 1 Bit | 1.1 switch | CW |
| 6 | <Ch. 1> Switching (timing) | Off/On | 1 Bit | 1.1 switch | CW |
| 7 | <Ch. 2> Switching (timing) | Off/On | 1 Bit | 1.1 switch | CW |
| 8 | <Ch. 3> Switching (timing) | Off/On | 1 Bit | 1.1 switch | CW |
| 9 | <Ch. 1> Dimming | Dimming control | 4 Bit | 3.7 dimming control | CW |
| 10 | <Ch. 2> Dimming | Dimming control | 4 Bit | 3.7 dimming control | CW |
| 11 | <Ch. 3> Dimming | Dimming control | 4 Bit | 3.7 dimming control | CW |
| 12 | <Ch. 1> Dimming Value | Value % | 1 Byte | 5.1 percentage (0..100%) | CW |
| 13 | <Ch. 2> Dimming Value | Value % | 1 Byte | 5.1 percentage (0..100%) | CW |
| 14 | <Ch. 3> Dimming Value | Value % | 1 Byte | 5.1 percentage (0..100%) | CW |
| 15 | <Ch. 1> Dimming Status | Feedback % | 1 Byte | 5.1 percentage (0..100%) | CRT |
| 16 | <Ch. 2> Dimming Status | Feedback % | 1 Byte | 5.1 percentage (0..100%) | CRT |
| 17 | <Ch. 3> Dimming Status | Feedback % | 1 Byte | 5.1 percentage (0..100%) | CRT |
| 18 | <Ch. 1> Status | Off/On | 1 Bit | 1.1 switch | CRT |
| 19 | <Ch. 2> Status | Off/On | 1 Bit | 1.1 switch | CRT |
| 20 | <Ch. 3> Status | Off/On | 1 Bit | 1.1 switch | CRT |
| 21 | <Ch. 1> Logic Function | Logic | 1 Bit | 1.2 boolean | CW |
| 21 | <Ch. 1> Lock Function | Disable/Enable | 1 Bit | 1.1 switch | CW |
| 22 | <Ch. 2> Logic Function | Logic | 1 Bit | 1.2 boolean | CW |
| 22 | <Ch. 2> Lock Function | Disable/Enable | 1 Bit | 1.1 switch | CW |
| 23 | <Ch. 3> Logic Function | Logic | 1 Bit | 1.2 boolean | CW |
| 23 | <Ch. 3> Lock Function | Disable/Enable | 1 Bit | 1.1 switch | CW |
| 24 | <Ch. 1> Scene | Scene | 1 Byte | CW | |
| 25 | <Ch. 2> Scene | Scene | 1 Byte | CW | |
| 26 | <Ch. 3> Scene | Scene | 1 Byte | CW | |
| 27 | Dynamic Scene | Disable/Enable | 1 Bit | 1.1 switch | CW |
| 30 | <Ch. 1> Alarm Function | Alarm | 1 Bit | CRT | |
| 30 | <Ch. 1> Alarm Function | Alarm | 1 Byte | CRT | |
| 31 | <Ch. 2> Alarm Function | Alarm | 1 Bit | CRT | |
| 31 | <Ch. 2> Alarm Function | Alarm | 1 Byte | CRT | |
| 32 | <Ch. 3> Alarm Function | Alarm | 1 Bit | CRT | |
| 32 | <Ch. 3> Alarm Function | Alarm | 1 Byte | CRT | |
| 33 | <Ch. 1> Economical Mode | Disable/Enable | 1 Bit | 1.1 switch | CW |
| 34 | <Ch. 2> Economical Mode | Disable/Enable | 1 Bit | 1.1 switch | CW |
| 35 | <Ch. 3> Economical Mode | Disable/Enable | 1 Bit | 1.1 switch | CW |
| 36 | <Ch. 1> Ramp Time | 0-255 | 1 Byte | 5.10 counter pulses (0..255) | CW |
| 37 | <Ch. 2> Ramp Time | 0-255 | 1 Byte | 5.10 counter pulses (0..255) | CW |
| 38 | <Ch. 3> Ramp Time | 0-255 | 1 Byte | 5.10 counter pulses (0..255) | CW |
| 39 | <Ch. 1> Actual Temperature | Value °C | 2 Bytes | 9.1 temperature (°C) | CRT |
| 40 | <Ch. 2> Actual Temperature | Value °C | 2 Bytes | 9.1 temperature (°C) | CRT |
| 41 | <Ch. 3> Actual Temperature | Value °C | 2 Bytes | 9.1 temperature (°C) | CRT |
Parameters (79)
| Parameter | Type | Default |
|---|---|---|
| Delay to send telegrams on power up [sec] | unsignedInt 5…15 | 5 |
| Enable temperature object | list | false |
| Sending interval | list | no sending |
| Send temperature if variation >= 5°C | list | true |
| Enable additional channel 2 | list | false |
| Enable additional channel 3 | list | false |
| Dynamic scene object | list | false |
| Type of load | list | manual local setting |
| Type of curve | list | pattern 1 |
| Maximum dimming value [50...100%] | unsignedInt 50…100 | 100 |
| Minimum dimming value [0...45%] | unsignedInt 0…45 | 0 |
| Dimming time from 0% to 100% [sec] | unsignedInt 0…255 | 10 |
| Local buttons | list | disabled |
| Behaviour on KNX bus power down [0...100%] (101=no action) | unsignedInt 0…101 | 101 |
| Behaviour on KNX bus power up [0...100%] (101=previous state) | unsignedInt 0…101 | 101 |
| Brightness at switch on [1...100%] (101=previous state) | unsignedInt 1…101 | 100 |
| Absolute value object [0...100%] | list | disabled |
| Additional function | list | no function |
| Activation telegram | list | telegram "1" |
| Timing function | list | timing function disabled |
| Dimming time from 0% to 100% for timing function [sec] | unsignedInt 0…255 | 10 |
| Delay on activation | list | false |
| Delay on activation (base time) | list | 1 sec |
| Delay on activation (factor) | unsignedInt 1…255 | 1 |
| Delay on deactivation | list | false |
| Delay on deactivation (base time) | list | 1 sec |
| Delay on deactivation (factor) | unsignedInt 1…255 | 1 |
| Timing (base time) | list | 1 sec |
| Timing (factor) | unsignedInt 1…255 | 1 |
| Timing can be stopped | list | false |
| Warning function | list | false |
| Warning time (seconds before time ends) | list | 15 sec |
| Switch off time | list | 1.0 sec |
| Receiving on when timing is active | list | trigger mode |
| Maximum number of time extension | list | 4 times |
| Scene | list | disabled |
| Enable ramp time object | list | false |
| Economical mode | list | disabled |
| Maximum dimming value in economical mode [20...90%] | unsignedInt 20…90 | 80 |
| Timing economical object [hr] (0=time unlimited) | unsignedInt 0…24 | 0 |
| Scene A [0...63] (64=not active) | unsignedInt 0…64 | 1 |
| Initial value scene A [0...100%] | unsignedInt 0…100 | 10 |
| Dimming time scene A from 0% to 100% [sec] | unsignedInt 0…255 | 10 |
| Scene B [0...63] (64=not active) | unsignedInt 0…64 | 2 |
| Initial value scene B [0...100%] | unsignedInt 0…100 | 25 |
| Dimming time scene B from 0% to 100% [sec] | unsignedInt 0…255 | 10 |
| Scene C [0...63] (64=not active) | unsignedInt 0…64 | 3 |
| Initial value scene C [0...100%] | unsignedInt 0…100 | 40 |
| Dimming time scene C from 0% to 100% [sec] | unsignedInt 0…255 | 10 |
| Scene D [0...63] (64=not active) | unsignedInt 0…64 | 4 |
| Initial value scene D [0...100%] | unsignedInt 0…100 | 50 |
| Dimming time scene D from 0% to 100% [sec] | unsignedInt 0…255 | 10 |
| Scene E [0...63] (64=not active) | unsignedInt 0…64 | 5 |
| Initial value scene E [0...100%] | unsignedInt 0…100 | 60 |
| Dimming time scene E from 0% to 100% [sec] | unsignedInt 0…255 | 10 |
| Scene F [0...63] (64=not active) | unsignedInt 0…64 | 6 |
| Initial value scene F [0...100%] | unsignedInt 0…100 | 75 |
| Dimming time scene F from 0% to 100% [sec] | unsignedInt 0…255 | 10 |
| Scene G [0...63] (64=not active) | unsignedInt 0…64 | 7 |
| Initial value scene G [0...100%] | unsignedInt 0…100 | 90 |
| Dimming time scene G from 0% to 100% [sec] | unsignedInt 0…255 | 10 |
| Scene H [0...63] (64=not active) | unsignedInt 0…64 | 8 |
| Initial value scene H [0...100%] | unsignedInt 0…100 | 100 |
| Dimming time scene H from 0% to 100% [sec] | unsignedInt 0…255 | 10 |
| Learn scene | list | enabled |
| Submit to dynamic scene function | list | false |
| Keep scenes value after download | list | disabled |
| Logic function | list | AND |
| Initial value for logic object | list | last value received |
| Initial value for lock object | list | last value received |
| Telegram for lock activation | list | telegram "1" |
| Brightness value % when lock is active (101=no action) | unsignedInt 0…101 | 0 |
| Position when lock ends | list | fixed value |
| Brightness value % when lock ends (101=no action) | unsignedInt 0…101 | 0 |
| Behaviour on KNX or local bus power down [0...100%] (101=no action) | unsignedInt 0…101 | 101 |
| Alarm object channel 1 | list | 1-bit object |
| Sending interval | list | no cyclic sending |
| Alarm object channel 2 | list | 1-bit object |
| Alarm object channel 3 | list | 1-bit object |
Version history
| Application | App no | Fingerprint | First seen | Size | File |
|---|---|---|---|---|---|
| MK2007 DIN Rail 1ch Module 1.0 latest | $030B | 6188 | 2026-11-25 | 84 KB | Download |
About this file
This is the official ETS product database for the Moorgen Deutschland GmbH MK2007 DIN Rail 1ch Module (MK2007), published by the manufacturer in the KNX online catalog. To use it, open ETS, go to Catalogs → Import and choose the downloaded .knxprod file. The device then appears in your catalog and can be added to a project. Older versions are kept so existing projects can be matched to the application program they were commissioned with.
More from Moorgen Deutschland GmbH
- PIR or(and) Microwave Sensor BKA501S/6S
- 4-Channel Motor Actuator MK1007
- 16 Input / 16 Output Module MK2/MKL/BK2/BKL 025A&016A&012A&027A
- MK2001 DIN Rail 4 Out Module MK2001
- MK2008 DIN Rail 8 Out Module MK2008
- MK2012 DIN Rail 12 Out Module MK2012
- 8-Channel 16A Switch Actuator MK2016
- 12-Channel 16A Switch Actuator MK2017
- 4-Channel Universal Switch Actuator MK2025
- 8-Channel 10A Universal Switch Actuator MK2026
- 16-Channel 10A Switch Actuator MK2027
- 4-Channel 1-10V Dimming Actuator MK2031