| Light value | list | 100% light |
| Release time for locking | unsignedInt 0…600 | 0 |
| Staircase light | list | not active |
| Dimming speed for switch off | list | 2 s |
| Dim speed for absolute dimming | unsignedInt 1…120 | 5 |
| Dim speed for relative dimming | unsignedInt 1…120 | 5 |
| Startup timeout(Bus) | list | 2 s |
| Off delay | unsignedInt 0…30000 | 0 |
| Behavior at unlocking | list | light value |
| Automatic function | list | not active |
| Send on/off state | list | at change |
| Behavior at locking | list | light value |
| When permanent OFF | list | dimm down off |
| Timed on retrigger function | list | not active |
| Send dim value after change | list | at dim end |
| Manual off enable | list | not active |
| Maximum set value | list | 100% |
| Invert lock device | list | not active |
| Light value | list | 50% light |
| Switch on behavior | list | on-value setting |
| Brightness value during permanent ON | list | 50% |
| Behavior after bus power up | list | off |
| Prewarning | list | not active |
| Value of switch on behavior | list | 100% |
| Timed on duration | unsignedInt 1…30000 | 90 |
| Automatic function 1-Exposure value | list | off |
| Send lamp failure state1 | list | any of them |
| Dimming speed for switch on set value | list | 2 s |
| Relative off enable | list | not active |
| Learn scene | list | not active |
| Automatic function 2-Exposure value | list | off |
| Scenes | list | not active |
| Behavior at locking | list | off |
| Prewarning duration in | unsignedInt 1…30000 | 10 |
| Automatic function 3-Exposure value | list | off |
| Behavior at unlocking | list | off |
| On delay | unsignedInt 0…30000 | 0 |
| Automatic function 4-Exposure value | list | off |
| Value of dimming down | list | 20% |
| Behavior bus power up | list | last value |
| Minimum set value | list | 0.5% |
| Transmission cycle time(0=not active) | unsignedInt 0…30000 | 0 |
| Dimming curve | list | linear |
| Counting of operating hours & CLO | list | not active |
| CLO factor | list | 85% |
| CLO factor | list | 100% |
| CLO factor | list | 90% |
| LED module work time before | unsignedInt 1…500 | 100 |
| LED module work time before | unsignedInt 1…500 | 150 |
| LED module work time before | unsignedInt 1…500 | 300 |
| LED module work time before | unsignedInt 1…500 | 200 |
| Constant light output(CLO) | list | not active |
| Send counters on change(per hour) | list | active |
| CLO factor | list | 80% |
| CLO factor | list | 95% |
| Send counters cyclically | list | not active |
| Power consumption active | list | not active |
| Actual connected LED load | unsignedInt 1…200 | 200 |
| Send watts report cyclically | list | not active |
| Counting of operating hours in | list | seconds |
| PWM Frequency Value | list | 1500 |
| Eliminate Tamb Alarm protection via | list | automatic |
| Send temperature report cyclically | list | not active |
| Tunit Alarm Hysteresis | unsignedInt 5…20 | 20 |
| Tunit Alarm Trigger point | unsignedInt 25…85 | 75 |
| Temperature Measurement | list | not active |
| Temperature Alarm protection | list | not active |
| Relative on enable | list | active |
| Report temperature value by | list | Tunit: Unit internal temperature |
| Watts report linked to CLO | list | not active |
| Tamb correction factor | unsignedInt 0…50 | 42 |
| Tamb Alarm Hysteresis | unsignedInt 5…20 | 20 |
| Tamb Alarm Trigger point | unsignedInt 25…85 | 75 |
| (Tamb = Tunit - Tamb correction factor) | text | |
| (value "1" to "0") | text | |
| (0 min = not active) | text | |
| Eliminate Tunit Alarm protection via | list | automatic |
| PIDHardware | list | PIDHardware |
| PidVersion | unsignedInt 0…65535 | 6208 |
| Send lamp failure state2 | list | not active |
| Select the lifetime of connected LED load | list | L70 |
| Dimming mode selection | list | dimming |
| BaseReserve0 | list | reserve |
| Correction characteristic enable | list | not active |
| Number of correcting points | unsignedInt 1…2 | 1 |
| KNX dimming value | list | 10% |
| KNX dimming value | list | 50% |
| KNX dimming value | list | 70% |
| KNX dimming value | list | 90% |
| Measured lux value/sensor value | unsignedInt 0…10000 | 400 |
| Measured lux value/sensor value | unsignedInt 0…10000 | 2000 |
| Measured lux value/sensor value | unsignedInt 0…10000 | 2800 |
| Measured lux value/sensor value | unsignedInt 0…10000 | 3600 |
| Measured lux value/sensor value at 100% | unsignedInt 0…10000 | 4000 |
| Measured lux value/sensor value at 0% | unsignedInt 0…10000 | 0 |
| CrLedReserve0 | list | reserve |
| CrLedReserve1 | list | reserve |
| CrLedReserve2 | list | reserve |
| CrLedReserve3 | list | reserve |
| Dimmer Mode | list | normal dimmer |
| Energy consumption feedback | list | not active |
| Send energy report cyclically | list | not active |
| Time 0 | unsignedInt 100…65535 | 1000 |
| Time 1 | unsignedInt 100…65535 | 1000 |
| Time 2 | unsignedInt 100…65535 | 1000 |
| Time 3 | unsignedInt 100…65535 | 1000 |
| Time 4 | unsignedInt 100…65535 | 1000 |
| Time 5 | unsignedInt 100…65535 | 1000 |
| Time 6 | unsignedInt 100…65535 | 1000 |
| Time 7 | unsignedInt 100…65535 | 1000 |
| Limit 0 | list | 10% |
| Limit 1 | list | 20% |
| Limit 2 | list | 30% |
| Limit 3 | list | 40% |
| Limit 4 | list | 50% |
| Limit 5 | list | 60% |
| Limit 6 | list | 70% |
| Limit 7 | list | 80% |
| MulReserve0 | list | reserve |
| MulReserve1 | list | reserve |
| MulReserve2 | list | reserve |
| MulReserve3 | list | reserve |
| Object selection for the energy | list | value in kWh(DPT 13.013) |
| Voltage,current,power feedback | list | not active |
| Send output power report cyclically | list | 5s |
| Object selection for the current | list | value in A(DPT 14.019) |
| Object selection for the voltage | list | value in V(DPT 14.027) |
| Scene 1 | list | not active |
| Scene 10 | list | not active |
| Scene 11 | list | not active |
| Scene 12 | list | not active |
| Scene 13 | list | not active |
| Scene 14 | list | not active |
| Scene 15 | list | not active |
| Scene 16 | list | not active |
| Scene 17 | list | not active |
| Scene 18 | list | not active |
| Scene 19 | list | not active |
| Scene 2 | list | not active |
| Scene 20 | list | not active |
| Scene 21 | list | not active |
| Scene 22 | list | not active |
| Scene 23 | list | not active |
| Scene 24 | list | not active |
| Scene 25 | list | not active |
| Scene 26 | list | not active |
| Scene 27 | list | not active |
| Scene 28 | list | not active |
| Scene 29 | list | not active |
| Scene 3 | list | not active |
| Scene 30 | list | not active |
| Scene 31 | list | not active |
| Scene 32 | list | not active |
| Scene 4 | list | not active |
| Scene 5 | list | not active |
| Scene 6 | list | not active |
| Scene 7 | list | not active |
| Scene 8 | list | not active |
| Scene 9 | list | not active |
| Light value | list | off |
| Scene number | list | 1 |
| Transition time to new brightness | unsignedInt 1…240 | 10 |
| Send lamp failure state1 | list | not active |
| Send lamp failure state3 | list | not active |
| Send lamp failure state4 | list | not active |
| stWattReportParaReserve0 | list | reserve |
| stWattReportParaReserve1 | list | reserve |
| Subrange num | unsignedInt 1…8 | 2 |
| Dimming time adjustable via object “Flexible dimming time/fade time” | list | not active |
| Action for brightness change in auto-dimming | list | no reaction |
| Auto-dimming over time | list | not active |
| Brightness | list | off |
| Dimming behavior | list | smooth transition between two times |
| End at the latest time point | list | active |
| Delay time | list | 5 min |
| Hour | unsignedInt 0…23 | 8 |
| Hour | unsignedInt 0…23 | 9 |
| Hour | unsignedInt 0…23 | 10 |
| Hour | unsignedInt 0…23 | 11 |
| Hour | unsignedInt 0…23 | 12 |
| Hour | unsignedInt 0…23 | 0 |
| Hour | unsignedInt 0…23 | 14 |
| Hour | unsignedInt 0…23 | 15 |
| Hour | unsignedInt 0…23 | 16 |
| Hour | unsignedInt 0…23 | 17 |
| Minute | unsignedInt 0…59 | 0 |
| Behavior at control object “Stop” (Select “Stop” via “Start/Stop auto-dimming...”) | list | switch off |
| TdReserve0 | list | reserve |
| TdReserve1 | list | reserve |
| TdReserve2 | list | reserve |
| TdReserve3 | list | reserve |
| Time step | list | 10 |
| Switch off behavior | list | switch off |
| Switch off value | list | 10% |
| Behavior | list | flashing when bus power on |
| Life time pre-warning | list | not active |
| Pre-warning time | unsignedInt 1…87600 | 43800 |
| Model Selection | list | XLC-25-H-KN |
| Output value | unsignedInt 0…100 | 10 |
| Output value | unsignedInt 0…100 | 50 |
| Output value | unsignedInt 0…100 | 70 |
| Output value | unsignedInt 0…100 | 90 |
| Output value | unsignedInt 0…100 | 100 |
| Output value | unsignedInt 0…100 | 0 |
| Correction by | list | measured value(lux) |
| KNX dimming value 0%(OFF) | unsignedInt 0…255 | 0 |
| KNX dimming value 100% | unsignedInt 0…255 | 100 |
| Scene1Enable | list | not active |
| Scene1LightVal | list | off |
| Scene1Num | list | 1 |
| Scene1TransTime | unsignedInt 1…240 | 16 |
| Scene2Enable | list | not active |
| Scene2LightVal | list | off |
| Scene2Num | list | 1 |
| Scene2TransTime | unsignedInt 1…240 | 16 |
| Scene3Enable | list | not active |
| Scene3LightVal | list | off |
| Scene3Num | list | 1 |
| Scene3TransTime | unsignedInt 1…240 | 16 |
| Scene4Enable | list | not active |
| Scene4LightVal | list | off |
| Scene4Num | list | 1 |
| Scene4TransTime | unsignedInt 1…240 | 16 |
| Scene5Enable | list | not active |
| Scene5LightVal | list | off |
| Scene5Num | list | 1 |
| Scene5TransTime | unsignedInt 1…240 | 16 |
| Scene6Enable | list | not active |
| Scene6LightVal | list | off |
| Scene6Num | list | 1 |
| Scene6TransTime | unsignedInt 1…240 | 16 |
| Scene7Enable | list | not active |
| Scene7LightVal | list | off |
| Scene7Num | list | 1 |
| Scene7TransTime | unsignedInt 1…240 | 16 |
| Scene8Enable | list | not active |
| Scene8LightVal | list | off |
| Scene8Num | list | 1 |
| Scene8TransTime | unsignedInt 1…240 | 16 |
| Push Dim Port | list | not active |
| Blocking object for push dim | list | not active |
| If backup DC input, dimming output | list | light value |
| Light value | list | 10% |
| Debounce time | list | 100ms |
| Dimming mode | list | START/STOP dimming |
| Brightness change on every sent telegram | list | 25% |
| Function dimming | list | dimming and switching |
| Function of push dim port | list | push dim |
| Long operation after | list | 1.0s |
| When AC input failure, led driver | list | no reaction |
| Telegram repeated every in s | list | 1.0s |
| Current level | list | 300mA |
| Current level | list | 600mA |
| Current level | list | 900mA |
| Telegram send after change | list | not active |
| Light value after protection | list | 50% light |
| Sketch map | picture | |
| LED Driver under control by PUSH DIM | list | active |
| Scene Number | unsignedInt 1…64 | 1 |
| On short operation:switch | list | toggle |
| On short operation:switch | list | start staircase light |
| On long operation:dimming direction | list | brighter |
| On operation:dimming direction | list | brighter |
| Send dim value report cyclically | list | not active |
| Send lamp failure state report cyclically | list | not active |
| Send on/off state report cyclically | list | not active |
| Dimming speed for start staircase light | list | 2 s |