AMI-0416.01 Switch Actuator with current measur.4f AMI-0416.01
MDT technologies GmbH · Order number AMI-0416.01 · Archive › Actuators › Switch Actuators witch current measurement
Industrial version 230VAC, 16A, 200µF C-Load
Download .knxprod Switching, Staircase, Meter current 4f 1.6 · 112 KB
Product
| Manufacturer | MDT technologies GmbH |
|---|---|
| Product name | AMI-0416.01 Switch Actuator with current measur.4f |
| Order number | AMI-0416.01 |
| Hardware | Schaltaktor mit Strommessung 4-fach, 8TE, 230V,16A |
| Medium | Twisted Pair |
| Bus current (mA) | 10 |
| Rail mounted | Yes |
| Width (mm) | 71.3 |
| Registration | Certified · 2011-11-08 |
| Languages | de-DE, en-US, es-ES |
| Catalog entry | M-0083_H-8-1_HP-0018-16-18AC_CI-AMI.2D0416.2E01-2 |
| Fingerprint | 18AC |
| SHA-256 | 995f08c058ecae4509e0ade16c92413c58d9885c734cacf40d677d400724ad2d |
| First seen | 2026-11-25 |
| Markets | 69 markets |
Application program: Switching, Staircase, Meter current 4f 1.6
| Application number | $0018 |
|---|---|
| Version | 1.6 |
| Mask version | MV-0701 (7.1) |
| KNX Data Secure | No |
| Minimum ETS version | 3.0d |
| Parameters | 503 |
| Group objects | 110 |
Group objects (110)
| No | Name | Function | Size | DPT | Flags |
|---|---|---|---|---|---|
| 0 | Channel A | Switch On/Off | 1 Bit | 1.1 switch | CW |
| 1 | Channel A | Staircase | 1 Bit | 1.1 switch | CW |
| 2 | Channel A | Block | 1 Bit | 1.3 enable | CW |
| 3 | Channel A | Forced | 2 Bit | 2.1 switch control | CW |
| 4 | Channel A | Scene | 1 Byte | CW | |
| 5 | Channel A | State | 1 Bit | CRT | |
| 6 | Channel A | Logic 1 | 1 Bit | 1.2 boolean | CW |
| 7 | Channel A | Logic 2 | 1 Bit | 1.2 boolean | CW |
| 8 | Channel A | Response operating hours | 2 Bytes | CRT | |
| 8 | Channel A | Time to the next service | 2 Bytes | CRT | |
| 9 | Channel A | Reset operating hours | 1 Bit | 1.1 switch | CW |
| 9 | Channel A | Reset service | 1 Bit | 1.1 switch | CW |
| 10 | Channel A | Service required | 1 Bit | CRT | |
| 11 | Channel A | Current value | 2 Bytes | CRT | |
| 11 | Channel A | Current value | 2 Bytes | 9.21 current (mA) | CRT |
| 11 | Channel A | Current value | 4 Bytes | 14.19 electric current (A) | CRT |
| 12 | Channel A | Exceedance of load | 1 Bit | 1.1 switch | CRT |
| 13 | Channel A | Lower deviation of load | 1 Bit | 1.1 switch | CRT |
| 14 | Channel A | Load faulty | 1 Bit | CRT | |
| 14 | Channel A | Fault current | 1 Bit | CRT | |
| 14 | Channel A | Fault current/Load faulty | 1 Bit | CRT | |
| 15 | Channel A | Reset power meter | 1 Bit | 1.3 enable | CW |
| 16 | Channel A | Active energy (Wh) | 4 Bytes | CRT | |
| 16 | Channel A | Active energy (kWh) | 4 Bytes | CRT | |
| 17 | CO_dummyA2 | 1 Bit | CRT | ||
| 18 | Channel B | Switch On/Off | 1 Bit | 1.1 switch | CW |
| 19 | Channel B | Staircase | 1 Bit | 1.1 switch | CW |
| 20 | Channel B | Block | 1 Bit | 1.3 enable | CW |
| 21 | Channel B | Forced | 2 Bit | 2.1 switch control | CW |
| 22 | Channel B | Scene | 1 Byte | CW | |
| 23 | Channel B | State | 1 Bit | CRT | |
| 24 | Channel B | Logic 1 | 1 Bit | 1.2 boolean | CW |
| 25 | Channel B | Logic 2 | 1 Bit | 1.2 boolean | CW |
| 26 | Channel B | Response operating hours | 2 Bytes | CRT | |
| 26 | Channel B | Time to the next service | 2 Bytes | CRT | |
| 27 | Channel B | Reset operating hours | 1 Bit | 1.1 switch | CW |
| 27 | Channel B | Reset service | 1 Bit | 1.1 switch | CW |
| 28 | Channel B | Service required | 1 Bit | CRT | |
| 29 | Channel B | Current value | 2 Bytes | CRT | |
| 29 | Channel B | Current value | 2 Bytes | 9.21 current (mA) | CRT |
| 29 | Channel B | Current value | 4 Bytes | 14.19 electric current (A) | CRT |
| 30 | Channel B | Exceedance of load | 1 Bit | 1.1 switch | CRT |
| 31 | Channel B | Lower deviation of load | 1 Bit | 1.1 switch | CRT |
| 32 | Channel B | Fault current | 1 Bit | CRT | |
| 32 | Channel B | Load faulty | 1 Bit | CRT | |
| 32 | Channel B | Fault current/Load faulty | 1 Bit | CRT | |
| 33 | Channel B | Reset power meter | 1 Bit | 1.3 enable | CW |
| 34 | Channel B | Active energy (Wh) | 4 Bytes | CRT | |
| 34 | Channel B | Active energy (kWh) | 4 Bytes | CRT | |
| 35 | CO_dummyB2 | 1 Bit | CRT | ||
| 36 | Channel C | Switch On/Off | 1 Bit | 1.1 switch | CW |
| 37 | Channel C | Staircase | 1 Bit | 1.1 switch | CW |
| 38 | Channel C | Block | 1 Bit | 1.3 enable | CW |
| 39 | Channel C | Forced | 2 Bit | 2.1 switch control | CW |
| 40 | Channel C | Scene | 1 Byte | CW | |
| 41 | Channel C | State | 1 Bit | CRT | |
| 42 | Channel C | Logic 1 | 1 Bit | 1.2 boolean | CW |
| 43 | Channel C | Logic 2 | 1 Bit | 1.2 boolean | CW |
| 44 | Channel C | Response operating hours | 2 Bytes | CRT | |
| 44 | Channel C | Time to the next service | 2 Bytes | CRT | |
| 45 | Channel C | Reset operating hours | 1 Bit | 1.1 switch | CW |
| 45 | Channel C | Reset service | 1 Bit | 1.1 switch | CW |
| 46 | Channel C | Service required | 1 Bit | CRT | |
| 47 | Channel C | Current value | 2 Bytes | CRT | |
| 47 | Channel C | Current value | 2 Bytes | 9.21 current (mA) | CRT |
| 47 | Channel C | Current value | 4 Bytes | 14.19 electric current (A) | CRT |
| 48 | Channel C | Exceedance of load | 1 Bit | 1.1 switch | CRT |
| 49 | Channel C | Lower deviation of load | 1 Bit | 1.1 switch | CRT |
| 50 | Channel C | Fault current | 1 Bit | CRT | |
| 50 | Channel C | Load faulty | 1 Bit | CRT | |
| 50 | Channel C | Fault current/Load faulty | 1 Bit | CRT | |
| 51 | Channel C | Reset power meter | 1 Bit | 1.3 enable | CW |
| 52 | Channel C | Active energy (Wh) | 4 Bytes | CRT | |
| 52 | Channel C | Active energy (kWh) | 4 Bytes | CRT | |
| 53 | CO_dummyC2 | 1 Bit | CRT | ||
| 54 | Channel D | Switch On/Off | 1 Bit | 1.1 switch | CW |
| 55 | Channel D | Staircase | 1 Bit | 1.1 switch | CW |
| 56 | Channel D | Block | 1 Bit | 1.3 enable | CW |
| 57 | Channel D | Forced | 2 Bit | 2.1 switch control | CW |
| 58 | Channel D | Scene | 1 Byte | CW | |
| 59 | Channel D | State | 1 Bit | CRT | |
| 60 | Channel D | Logic 1 | 1 Bit | 1.2 boolean | CW |
| 61 | Channel D | Logic 2 | 1 Bit | 1.2 boolean | CW |
| 62 | Channel D | Response operating hours | 2 Bytes | CRT | |
| 62 | Channel D | Time to the next service | 2 Bytes | CRT | |
| 63 | Channel D | Reset operating hours | 1 Bit | 1.1 switch | CW |
| 63 | Channel D | Reset service | 1 Bit | 1.1 switch | CW |
| 64 | Channel D | Service required | 1 Bit | CRT | |
| 65 | Channel D | Current value | 2 Bytes | CRT | |
| 65 | Channel D | Current value | 2 Bytes | 9.21 current (mA) | CRT |
| 65 | Channel D | Current value | 4 Bytes | 14.19 electric current (A) | CRT |
| 66 | Channel D | Exceedance of load | 1 Bit | 1.1 switch | CRT |
| 67 | Channel D | Lower deviation of load | 1 Bit | 1.1 switch | CRT |
| 68 | Channel D | Fault current | 1 Bit | CRT | |
| 68 | Channel D | Load faulty | 1 Bit | CRT | |
| 68 | Channel D | Fault current/Load faulty | 1 Bit | CRT | |
| 69 | Channel D | Reset power meter | 1 Bit | 1.3 enable | CW |
| 70 | Channel D | Active energy (Wh) | 4 Bytes | CRT | |
| 70 | Channel D | Active energy (kWh) | 4 Bytes | CRT | |
| 71 | CO_dummyD2 | 1 Bit | CRT | ||
| 72 | Central function | Operating | 1 Bit | CRT | |
| 73 | Central function | Group State | 4 Bytes | CRT | |
| 74 | Central function | Manual control | 1 Bit | 1.2 boolean | CW |
| 75 | Central function | Total active energy (kWh) | 4 Bytes | CRT | |
| 75 | Central function | Total active energy (Wh) | 4 Bytes | CRT | |
| 76 | Central function | Value of total current | 2 Bytes | 9.21 current (mA) | CRT |
| 76 | Central function | Value of total current | 4 Bytes | 14.19 electric current (A) | CRT |
| 76 | Central function | Value of total current | 2 Bytes | CRT | |
| 77 | Central function | Exceedance of total load | 1 Bit | 1.1 switch | CRT |
| 78 | Central function | Switch On/Off | 1 Bit | 1.1 switch | CW |
Parameters (97)
| Parameter | Type | Default |
|---|---|---|
| Disabled objects | unsignedInt 0…255 | 1 |
| Startup timeout | list | 1 s |
| Cyclic send of "Operating"-Telegramm | list | no send |
| Send group state | list | not active |
| Total current | list | not active |
| Object selection for the current measurement | list | Floating value in mA (DPT 9.021) |
| Faktor=1 | list | On |
| Factor for conversion into theoretical wattage kW: Current value x Factor | unsignedInt 100…250 | 230 |
| Send current value after changes value | list | not active |
| Cyclic send | list | not active |
| Monitoring exceedance of load | list | not active |
| Lastüberwachung inaktiv | list | Off |
| Factor for load monitoring [A] | unsignedInt 1…200 | 1 |
| Faktor für Lastüberwachung | list | 1 A |
| Hysteresis [%] | unsignedInt 10…100 | 10 |
| Behavior at exceeding | list | Send no telegramm |
| Behavior at not exceeding | list | Send no telegramm |
| Send exceeding cyclical | list | not active |
| Total power meter function (Wh/kWh) | list | not active |
| Object selection for total power meter | list | Value in Wh (DPT 13.010) |
| Sending object value | list | only request |
| Memory of all power meters delete after download of application | list | No |
| Channel A | list | Switch |
| Central function | list | not active |
| Channel activate | list | active |
| Manual control | list | active |
| Channel B | list | Switch |
| Channel C | list | Switch |
| Channel D | list | Switch |
| Mode | list | normaly opend |
| Block object | list | not active |
| Send cyclic the current state value | list | no send cyclic |
| delay on SOO or ADV | list | SOO |
| Prewarning time in [s] | unsignedInt 0…30000 | 0 |
| Time for staircase [s] | unsignedInt 0…30000 | 0 |
| Manual switching off | list | not active |
| Verlängern bei Treppenlicht | list | Disable |
| On delay [s] | unsignedInt 0…30000 | 0 |
| Off delay [s] | unsignedInt 0…30000 | 0 |
| State at the beginning of the lock state | list | Off |
| State at the end of the lock state | list | Off |
| Behaviour when locked | list | no change |
| Behaviour when unlocked | list | no change |
| invertieren des Lock Objektes | list | not inverted |
| Value of the device after bus power down | list | Off |
| Value of the device after bus power up | list | Off |
| Behaviour at bus power up | list | no change |
| Behaviour at bus power down | list | no change |
| Operating hours counter | list | not active |
| Current measurement | list | not active |
| Bus Power Up Message Delay | list | 1 s |
| Logical functions | list | not active |
| active Logic Inputs | list | not active |
| Logic operations | list | OR |
| mode | list | switching |
| Scene | list | not active |
| Type of operating hours counter | list | Operating hours counter |
| Count if | list | Relay ON |
| Send status of operating hours every … hours | unsignedInt 0…10000 | 0 |
| Send status of service hours every … [h] | unsignedInt 0…10000 | 0 |
| Send signal of service at … x10h intervals | unsignedInt 0…250 | 0 |
| Power meter function (Wh/kWh) | list | not active |
| Object selection for power meter | list | Value in Wh (DPT 13.010) |
| Current filter | list | Filter 1. step: meter 2 values than output |
| Object selection for the current measurement | list | Value in mA (DPT 7.012) |
| Add the channel to total current measurement | list | not active |
| Cyclic sending | list | not active |
| Value range for load monitoring | list | 100mA - 20A |
| Factor for load monitoring x100 mA | unsignedInt 1…200 | 1 |
| Advanced function only for hardware as from version R2.2 | text | <- TIP |
| Value for load monitoring | list | 50 mA |
| Monitoring lower deviation of load | list | not active |
| Behavior at deviating | list | Send no telegramm |
| Behavior at not deviating | list | Send no telegramm |
| Send falling below cyclical | list | not active |
| Message if contact opened | list | not active |
| Switching threshold | list | 20 mA |
| Save scene | list | disabled |
| Scene A | list | Off |
| Scene number A | list | 1 |
| Scene B | list | Off |
| Scene number B | list | 2 |
| Scene C | list | Off |
| Scene number C | list | 3 |
| Scene D | list | Off |
| Scene number D | list | 4 |
| Scene E | list | Off |
| Scene number E | list | 5 |
| Scene F | list | Off |
| Scene number F | list | 6 |
| Scene G | list | Off |
| Scene number G | list | 7 |
| Scene H | list | Off |
| Scene number H | list | 8 |
| Prewarning | list | not active |
| Warning time [s] | unsignedInt 0…30000 | 1 |
| Extend staircase time | list | not active |
Version history
| Application | App no | Fingerprint | First seen | Size | File |
|---|---|---|---|---|---|
| Switching, Staircase, Meter current 4f 1.6 latest | $0018 | 18AC | 2026-11-25 | 112 KB | Download |
| Switching, Staircase, Meter current 4f 1.2 | $0018 | E8AC | 2026-11-25 | 105 KB | Download |
About this file
This is the official ETS product database for the MDT technologies GmbH AMI-0416.01 Switch Actuator with current measur.4f (AMI-0416.01), published by the manufacturer in the KNX online catalog. To use it, open ETS, go to Catalogs → Import and choose the downloaded .knxprod file. The device then appears in your catalog and can be added to a project. Older versions are kept so existing projects can be matched to the application program they were commissioned with.
More from MDT technologies GmbH
- AKD-0224V.01 LED Controller 2 channel AKD-0224V.01
- AKD-0324V.01 RGB LED Controller AKD-0324V.01
- AKD-0410V.01 Dimming Control Unit 4-f, 4TE, 1-10V AKD-0410V.01
- AKD-0424R.01 RGBW LED Controller, MDRC AKD-0424R.01
- AKD-0424V.01 RGBW LED Controller AKD-0424V.01
- AKH-0400.01 Heating actuator 4-fold, 2SU,24/230VAC AKH-0400.01
- AKH-0800.01 Heating actuator 8-fold, 4SU,24/230VAC AKH-0800.01
- AKK-01UP.01 Switch Actuator 1-fold, UP, 16A AKK-01UP.01
- AKK-0216.01 Switch Actuator 2-fold, 2SU, 16A AKK-0216.01
- AKK-0216.02 Switch Actuator 2-fold, 2SU, 16A AKK-0216.02
- AKK-02UP.01 Switch Actuator 2-fold, UP, 6A AKK-02UP.01
- AKK-03UP.01 Switch Actuator 3fold, FanCoil AKK-03UP.01