Modular Push Button with Thermostat MSW100x-MPL-T
Makel Elektrik · Order number MSW100x-MPL-T · Buttons › Push/Touch Buttons
Modular Push Button with Thermostat
Download .knxprod MSW100x-MPL-T_v1.1_349a6d5 1.1 · 300 KB
Product
| Manufacturer | Makel Elektrik |
|---|---|
| Product name | Modular Push Button with Thermostat |
| Order number | MSW100x-MPL-T |
| Hardware | Modular Push Button with Thermostat |
| Medium | Twisted Pair |
| Bus current (mA) | 4 |
| Rail mounted | No |
| Registration | Certified · 2025-01-23 |
| Languages | tr-TR, de-DE, en-US |
| Catalog entry | M-0111_H-MSW100x.2DMPL.5FT.5F07012025-1_HP-300F-11-E867_CI-MSW100x.2DMPL.2DT-1 |
| Fingerprint | E867 |
| SHA-256 | ff121e3b19aac8688eb1de4107d05a6eac2dfd72bd122ce37631df95893cb251 |
| First seen | 2026-11-25 |
| Markets | Belgium, Germany, Italy, Kazakhstan, Netherlands, Saudi Arabia, Turkey |
Application program: MSW100x-MPL-T_v1.1_349a6d5 1.1
| Application number | $300F |
|---|---|
| Version | 1.1 |
| Mask version | MV-0705 (7.5) |
| KNX Data Secure | No |
| Minimum ETS version | 5.0 |
| Parameters | 602 |
| Group objects | 371 |
Group objects (371)
| No | Name | Function | Size | DPT | Flags |
|---|---|---|---|---|---|
| 0 | Button 1 | Status indication | 1 Bit | 1.1 switch | CWTU |
| 0 | Button 1 | Status indication ChA | 1 Bit | 1.1 switch | CWTU |
| 0 | Button 1 | State Up / Down | 1 Bit | 1.8 up/down | CWTU |
| 1 | Button 1 | ON / OFF | 1 Bit | 1.1 switch | CRTU |
| 1 | Button 1 | ON / OFF ChA | 1 Bit | 1.1 switch | CRTU |
| 1 | Button 1 | Up / Down | 1 Bit | 1.8 up/down | CRTU |
| 2 | Button 1 | Step Up / Down | 1 Bit | 1.8 up/down | CRTU |
| 3 | Button 1 | Priority | 2 Bit | 2.1 switch control | CRTU |
| 4 | Button 1 | Dimming | 4 Bit | 3.7 dimming control | CRTU |
| 5 | Button 1 | Scene Control | 1 Byte | 18.1 scene control | CRTU |
| 5 | Button 1 | HVAC Mode | 1 Byte | 20.102 HVAC mode | CRTU |
| 5 | Button 1 | DHW Mode | 1 Byte | 20.103 DHW mode | CRTU |
| 6 | Button 1 | Percentage | 1 Byte | 5.1 percentage (0..100%) | CRTU |
| 6 | Button 1 | Angle | 1 Byte | 5.3 angle (degrees) | CRTU |
| 7 | Button 1 | Status indication ChB | 1 Bit | 1.1 switch | CWTU |
| 8 | Button 1 | ON / OFF ChB | 1 Bit | 1.1 switch | CRTU |
| 9 | Button 1 | LED | 1 Bit | 1.1 switch | CWTU |
| 10 | Button 1 | Temperature | 2 Bytes | 9.1 temperature (°C) | CRTU |
| 10 | Button 1 | Luminosity | 2 Bytes | 9.4 lux (Lux) | CRTU |
| 11 | Button 1 | Jamming | 1 Bit | 1.2 boolean | CRWU |
| 12 | Button 1 | Percentage Value Indication | 1 Byte | 5.1 percentage (0..100%) | CWTU |
| 12 | Button 1 | Angle Value Indication | 1 Byte | 5.3 angle (degrees) | CWTU |
| 13 | Button 1 | Temperature Value Indication | 2 Bytes | 9.1 temperature (°C) | CWTU |
| 13 | Button 1 | Luminosity Value Indication | 2 Bytes | 9.4 lux (Lux) | CWTU |
| 14 | Button 2 | Status indication | 1 Bit | 1.1 switch | CWTU |
| 14 | Button 2 | Status indication ChA | 1 Bit | 1.1 switch | CWTU |
| 14 | Button 2 | State Up / Down | 1 Bit | 1.8 up/down | CWTU |
| 15 | Button 2 | ON / OFF | 1 Bit | 1.1 switch | CRTU |
| 15 | Button 2 | ON / OFF ChA | 1 Bit | 1.1 switch | CRTU |
| 15 | Button 2 | Up / Down | 1 Bit | 1.8 up/down | CRTU |
| 16 | Button 2 | Step Up / Down | 1 Bit | 1.8 up/down | CRTU |
| 17 | Button 2 | Priority | 2 Bit | 2.1 switch control | CRTU |
| 18 | Button 2 | Dimming | 4 Bit | 3.7 dimming control | CRTU |
| 19 | Button 2 | Scene Control | 1 Byte | 18.1 scene control | CRTU |
| 19 | Button 2 | HVAC Mode | 1 Byte | 20.102 HVAC mode | CRTU |
| 19 | Button 2 | DHW Mode | 1 Byte | 20.103 DHW mode | CRTU |
| 20 | Button 2 | Percentage | 1 Byte | 5.1 percentage (0..100%) | CRTU |
| 20 | Button 2 | Angle | 1 Byte | 5.3 angle (degrees) | CRTU |
| 21 | Button 2 | Status indication ChB | 1 Bit | 1.1 switch | CWTU |
| 22 | Button 2 | ON / OFF ChB | 1 Bit | 1.1 switch | CRTU |
| 23 | Button 2 | LED | 1 Bit | 1.1 switch | CWTU |
| 24 | Button 2 | Temperature | 2 Bytes | 9.1 temperature (°C) | CRTU |
| 24 | Button 2 | Luminosity | 2 Bytes | 9.4 lux (Lux) | CRTU |
| 25 | Button 2 | Jamming | 1 Bit | 1.2 boolean | CRWU |
| 26 | Button 2 | Percentage Value Indication | 1 Byte | 5.1 percentage (0..100%) | CWTU |
| 26 | Button 2 | Angle Value Indication | 1 Byte | 5.3 angle (degrees) | CWTU |
| 27 | Button 2 | Temperature Value Indication | 2 Bytes | 9.1 temperature (°C) | CWTU |
| 27 | Button 2 | Luminosity Value Indication | 2 Bytes | 9.4 lux (Lux) | CWTU |
| 28 | Button 3 | Status indication | 1 Bit | 1.1 switch | CWTU |
| 28 | Button 3 | Status indication ChA | 1 Bit | 1.1 switch | CWTU |
| 28 | Button 3 | State Up / Down | 1 Bit | 1.8 up/down | CWTU |
| 29 | Button 3 | ON / OFF | 1 Bit | 1.1 switch | CRTU |
| 29 | Button 3 | ON / OFF ChA | 1 Bit | 1.1 switch | CRTU |
| 29 | Button 3 | Up / Down | 1 Bit | 1.8 up/down | CRTU |
| 30 | Button 3 | Step Up / Down | 1 Bit | 1.8 up/down | CRTU |
| 31 | Button 3 | Priority | 2 Bit | 2.1 switch control | CRTU |
| 32 | Button 3 | Dimming | 4 Bit | 3.7 dimming control | CRTU |
| 33 | Button 3 | Scene Control | 1 Byte | 18.1 scene control | CRTU |
| 33 | Button 3 | HVAC Mode | 1 Byte | 20.102 HVAC mode | CRTU |
| 33 | Button 3 | DHW Mode | 1 Byte | 20.103 DHW mode | CRTU |
| 34 | Button 3 | Percentage | 1 Byte | 5.1 percentage (0..100%) | CRTU |
| 34 | Button 3 | Angle | 1 Byte | 5.3 angle (degrees) | CRTU |
| 35 | Button 3 | Status indication ChB | 1 Bit | 1.1 switch | CWTU |
| 36 | Button 3 | ON / OFF ChB | 1 Bit | 1.1 switch | CRTU |
| 37 | Button 3 | LED | 1 Bit | 1.1 switch | CWTU |
| 38 | Button 3 | Temperature | 2 Bytes | 9.1 temperature (°C) | CRTU |
| 38 | Button 3 | Luminosity | 2 Bytes | 9.4 lux (Lux) | CRTU |
| 39 | Button 3 | Jamming | 1 Bit | 1.2 boolean | CRWU |
| 40 | Button 3 | Percentage Value Indication | 1 Byte | 5.1 percentage (0..100%) | CWTU |
| 40 | Button 3 | Angle Value Indication | 1 Byte | 5.3 angle (degrees) | CWTU |
| 41 | Button 3 | Temperature Value Indication | 2 Bytes | 9.1 temperature (°C) | CWTU |
| 41 | Button 3 | Luminosity Value Indication | 2 Bytes | 9.4 lux (Lux) | CWTU |
| 42 | Button 4 | Status indication | 1 Bit | 1.1 switch | CWTU |
| 42 | Button 4 | Status indication ChA | 1 Bit | 1.1 switch | CWTU |
| 42 | Button 4 | State Up / Down | 1 Bit | 1.8 up/down | CWTU |
| 43 | Button 4 | ON / OFF | 1 Bit | 1.1 switch | CRTU |
| 43 | Button 4 | ON / OFF ChA | 1 Bit | 1.1 switch | CRTU |
| 43 | Button 4 | Up / Down | 1 Bit | 1.8 up/down | CRTU |
| 44 | Button 4 | Step Up / Down | 1 Bit | 1.8 up/down | CRTU |
| 45 | Button 4 | Priority | 2 Bit | 2.1 switch control | CRTU |
| 46 | Button 4 | Dimming | 4 Bit | 3.7 dimming control | CRTU |
| 47 | Button 4 | Scene Control | 1 Byte | 18.1 scene control | CRTU |
| 47 | Button 4 | HVAC Mode | 1 Byte | 20.102 HVAC mode | CRTU |
| 47 | Button 4 | DHW Mode | 1 Byte | 20.103 DHW mode | CRTU |
| 48 | Button 4 | Percentage | 1 Byte | 5.1 percentage (0..100%) | CRTU |
| 48 | Button 4 | Angle | 1 Byte | 5.3 angle (degrees) | CRTU |
| 49 | Button 4 | Status indication ChB | 1 Bit | 1.1 switch | CWTU |
| 50 | Button 4 | ON / OFF ChB | 1 Bit | 1.1 switch | CRTU |
| 51 | Button 4 | LED | 1 Bit | 1.1 switch | CWTU |
| 52 | Button 4 | Temperature | 2 Bytes | 9.1 temperature (°C) | CRTU |
| 52 | Button 4 | Luminosity | 2 Bytes | 9.4 lux (Lux) | CRTU |
| 53 | Button 4 | Jamming | 1 Bit | 1.2 boolean | CRWU |
| 54 | Button 4 | Percentage Value Indication | 1 Byte | 5.1 percentage (0..100%) | CWTU |
| 54 | Button 4 | Angle Value Indication | 1 Byte | 5.3 angle (degrees) | CWTU |
| 55 | Button 4 | Temperature Value Indication | 2 Bytes | 9.1 temperature (°C) | CWTU |
| 55 | Button 4 | Luminosity Value Indication | 2 Bytes | 9.4 lux (Lux) | CWTU |
| 56 | Button 5 | Status indication | 1 Bit | 1.1 switch | CWTU |
| 56 | Button 5 | Status indication ChA | 1 Bit | 1.1 switch | CWTU |
| 56 | Button 5 | State Up / Down | 1 Bit | 1.8 up/down | CWTU |
| 57 | Button 5 | ON / OFF | 1 Bit | 1.1 switch | CRTU |
| 57 | Button 5 | ON / OFF ChA | 1 Bit | 1.1 switch | CRTU |
| 57 | Button 5 | Up / Down | 1 Bit | 1.8 up/down | CRTU |
| 58 | Button 5 | Step Up / Down | 1 Bit | 1.8 up/down | CRTU |
| 59 | Button 5 | Priority | 2 Bit | 2.1 switch control | CRTU |
| 60 | Button 5 | Dimming | 4 Bit | 3.7 dimming control | CRTU |
| 61 | Button 5 | Scene Control | 1 Byte | 18.1 scene control | CRTU |
| 61 | Button 5 | HVAC Mode | 1 Byte | 20.102 HVAC mode | CRTU |
| 61 | Button 5 | DHW Mode | 1 Byte | 20.103 DHW mode | CRTU |
| 62 | Button 5 | Percentage | 1 Byte | 5.1 percentage (0..100%) | CRTU |
| 62 | Button 5 | Angle | 1 Byte | 5.3 angle (degrees) | CRTU |
| 63 | Button 5 | Status indication ChB | 1 Bit | 1.1 switch | CWTU |
| 64 | Button 5 | ON / OFF ChB | 1 Bit | 1.1 switch | CRTU |
| 65 | Button 5 | LED | 1 Bit | 1.1 switch | CWTU |
| 66 | Button 5 | Temperature | 2 Bytes | 9.1 temperature (°C) | CRTU |
| 66 | Button 5 | Luminosity | 2 Bytes | 9.4 lux (Lux) | CRTU |
| 67 | Button 5 | Jamming | 1 Bit | 1.2 boolean | CRWU |
| 68 | Button 5 | Percentage Value Indication | 1 Byte | 5.1 percentage (0..100%) | CWTU |
| 68 | Button 5 | Angle Value Indication | 1 Byte | 5.3 angle (degrees) | CWTU |
| 69 | Button 5 | Temperature Value Indication | 2 Bytes | 9.1 temperature (°C) | CWTU |
| 69 | Button 5 | Luminosity Value Indication | 2 Bytes | 9.4 lux (Lux) | CWTU |
| 70 | Button 6 | Status indication | 1 Bit | 1.1 switch | CWTU |
| 70 | Button 6 | Status indication ChA | 1 Bit | 1.1 switch | CWTU |
| 70 | Button 6 | State Up / Down | 1 Bit | 1.8 up/down | CWTU |
| 71 | Button 6 | ON / OFF | 1 Bit | 1.1 switch | CRTU |
| 71 | Button 6 | ON / OFF ChA | 1 Bit | 1.1 switch | CRTU |
| 71 | Button 6 | Up / Down | 1 Bit | 1.8 up/down | CRTU |
| 72 | Button 6 | Step Up / Down | 1 Bit | 1.8 up/down | CRTU |
| 73 | Button 6 | Priority | 2 Bit | 2.1 switch control | CRTU |
| 74 | Button 6 | Dimming | 4 Bit | 3.7 dimming control | CRTU |
| 75 | Button 6 | Scene Control | 1 Byte | 18.1 scene control | CRTU |
| 75 | Button 6 | HVAC Mode | 1 Byte | 20.102 HVAC mode | CRTU |
| 75 | Button 6 | DHW Mode | 1 Byte | 20.103 DHW mode | CRTU |
| 76 | Button 6 | Percentage | 1 Byte | 5.1 percentage (0..100%) | CRTU |
| 76 | Button 6 | Angle | 1 Byte | 5.3 angle (degrees) | CRTU |
| 77 | Button 6 | Status indication ChB | 1 Bit | 1.1 switch | CWTU |
| 78 | Button 6 | ON / OFF ChB | 1 Bit | 1.1 switch | CRTU |
| 79 | Button 6 | LED | 1 Bit | 1.1 switch | CWTU |
| 80 | Button 6 | Temperature | 2 Bytes | 9.1 temperature (°C) | CRTU |
| 80 | Button 6 | Luminosity | 2 Bytes | 9.4 lux (Lux) | CRTU |
| 81 | Button 6 | Jamming | 1 Bit | 1.2 boolean | CRWU |
| 82 | Button 6 | Percentage Value Indication | 1 Byte | 5.1 percentage (0..100%) | CWTU |
| 82 | Button 6 | Angle Value Indication | 1 Byte | 5.3 angle (degrees) | CWTU |
| 83 | Button 6 | Temperature Value Indication | 2 Bytes | 9.1 temperature (°C) | CWTU |
| 83 | Button 6 | Luminosity Value Indication | 2 Bytes | 9.4 lux (Lux) | CWTU |
| 84 | Button 7 | State Up / Down | 1 Bit | 1.8 up/down | CWTU |
| 84 | Button 7 | Status indication ChA | 1 Bit | 1.1 switch | CWTU |
| 84 | Button 7 | Status indication | 1 Bit | 1.1 switch | CWTU |
| 85 | Button 7 | ON / OFF | 1 Bit | 1.1 switch | CRTU |
| 85 | Button 7 | ON / OFF ChA | 1 Bit | 1.1 switch | CRTU |
| 85 | Button 7 | Up / Down | 1 Bit | 1.8 up/down | CRTU |
| 86 | Button 7 | Step Up / Down | 1 Bit | 1.8 up/down | CRTU |
| 87 | Button 7 | Priority | 2 Bit | 2.1 switch control | CRTU |
| 88 | Button 7 | Dimming | 4 Bit | 3.7 dimming control | CRTU |
| 89 | Button 7 | Scene Control | 1 Byte | 18.1 scene control | CRTU |
| 89 | Button 7 | HVAC Mode | 1 Byte | 20.102 HVAC mode | CRTU |
| 89 | Button 7 | DHW Mode | 1 Byte | 20.103 DHW mode | CRTU |
| 90 | Button 7 | Angle | 1 Byte | 5.3 angle (degrees) | CRTU |
| 90 | Button 7 | Percentage | 1 Byte | 5.1 percentage (0..100%) | CRTU |
| 91 | Button 7 | Status indication ChB | 1 Bit | 1.1 switch | CWTU |
| 92 | Button 7 | ON / OFF ChB | 1 Bit | 1.1 switch | CRTU |
| 93 | Button 7 | LED | 1 Bit | 1.1 switch | CWTU |
| 94 | Button 7 | Luminosity | 2 Bytes | 9.4 lux (Lux) | CRTU |
| 94 | Button 7 | Temperature | 2 Bytes | 9.1 temperature (°C) | CRTU |
| 95 | Button 7 | Jamming | 1 Bit | 1.2 boolean | CRWU |
| 96 | Button 7 | Angle Value Indication | 1 Byte | 5.3 angle (degrees) | CWTU |
| 96 | Button 7 | Percentage Value Indication | 1 Byte | 5.1 percentage (0..100%) | CWTU |
| 97 | Button 7 | Luminosity Value Indication | 2 Bytes | 9.4 lux (Lux) | CWTU |
| 97 | Button 7 | Temperature Value Indication | 2 Bytes | 9.1 temperature (°C) | CWTU |
| 98 | Button 8 | Status indication | 1 Bit | 1.1 switch | CWTU |
| 98 | Button 8 | Status indication ChA | 1 Bit | 1.1 switch | CWTU |
| 98 | Button 8 | State Up / Down | 1 Bit | 1.8 up/down | CWTU |
| 99 | Button 8 | ON / OFF | 1 Bit | 1.1 switch | CRTU |
| 99 | Button 8 | ON / OFF ChA | 1 Bit | 1.1 switch | CRTU |
| 99 | Button 8 | Up / Down | 1 Bit | 1.8 up/down | CRTU |
| 100 | Button 8 | Step Up / Down | 1 Bit | 1.8 up/down | CRTU |
| 101 | Button 8 | Priority | 2 Bit | 2.1 switch control | CRTU |
| 102 | Button 8 | Dimming | 4 Bit | 3.7 dimming control | CRTU |
| 103 | Button 8 | DHW Mode | 1 Byte | 20.103 DHW mode | CRTU |
| 103 | Button 8 | HVAC Mode | 1 Byte | 20.102 HVAC mode | CRTU |
| 103 | Button 8 | Scene Control | 1 Byte | 18.1 scene control | CRTU |
| 104 | Button 8 | Percentage | 1 Byte | 5.1 percentage (0..100%) | CRTU |
| 104 | Button 8 | Angle | 1 Byte | 5.3 angle (degrees) | CRTU |
| 105 | Button 8 | Status indication ChB | 1 Bit | 1.1 switch | CWTU |
| 106 | Button 8 | ON / OFF ChB | 1 Bit | 1.1 switch | CRTU |
| 107 | Button 8 | LED | 1 Bit | 1.1 switch | CWTU |
| 108 | Button 8 | Temperature | 2 Bytes | 9.1 temperature (°C) | CRTU |
| 108 | Button 8 | Luminosity | 2 Bytes | 9.4 lux (Lux) | CRTU |
| 109 | Button 8 | Jamming | 1 Bit | 1.2 boolean | CRWU |
| 110 | Button 8 | Percentage Value Indication | 1 Byte | 5.1 percentage (0..100%) | CWTU |
| 110 | Button 8 | Angle Value Indication | 1 Byte | 5.3 angle (degrees) | CWTU |
| 111 | Button 8 | Luminosity Value Indication | 2 Bytes | 9.4 lux (Lux) | CWTU |
| 111 | Button 8 | Temperature Value Indication | 2 Bytes | 9.1 temperature (°C) | CWTU |
| 112 | Logic A | Input 1 | 1 Bit | 1.2 boolean | CWTU |
| 112 | Logic A | Input DPT1 (1 bit) | 1 Bit | DPT.1 | CWTU |
| 112 | Logic A | Input 1 (inverted) | 1 Bit | 1.2 boolean | CWTU |
| 113 | Logic A | Input 2 | 1 Bit | 1.2 boolean | CWTU |
| 113 | Logic A | Input 2 (inverted) | 1 Bit | 1.2 boolean | CWTU |
| 114 | Logic A | Input 3 | 1 Bit | 1.2 boolean | CWTU |
| 114 | Logic A | Input 3 (inverted) | 1 Bit | 1.2 boolean | CWTU |
| 115 | Logic A | Input 4 | 1 Bit | 1.2 boolean | CWTU |
| 115 | Logic A | Input 4 (inverted) | 1 Bit | 1.2 boolean | CWTU |
| 116 | Logic A | Input DPT2 (2 bit) | 2 Bit | DPT.2 | CWTU |
| 117 | Logic A | Input DPT3 (4 bit) | 4 Bit | DPT.3 | CWTU |
| 118 | Logic A | Input (1 byte) | 1 Byte | DPT.5 | CWTU |
| 119 | Logic A | Input (2 byte) | 2 Bytes | DPT.7 | CWTU |
| 120 | Logic A | ON / OFF | 1 Bit | 1.1 switch | CRTU |
| 120 | Logic A | Output DPT1 (1 bit) | 1 Bit | DPT.1 | CRTU |
| 121 | Logic A | Output DPT2 (2 bit) | 2 Bit | DPT.2 | CRTU |
| 122 | Logic A | Output DPT3 (4 bit) | 4 Bit | DPT.3 | CRTU |
| 123 | Logic A | Scene | 1 Byte | 17.1 scene number | CRTU |
| 123 | Logic A | Percentage | 1 Byte | 5.1 percentage (0..100%) | CRTU |
| 123 | Logic A | Angle | 1 Byte | 5.3 angle (degrees) | CRTU |
| 123 | Logic A | Output (1 byte) | 1 Byte | DPT.5 | CRTU |
| 124 | Logic A | Temperature | 2 Bytes | 9.1 temperature (°C) | CRTU |
| 124 | Logic A | Luminosity | 2 Bytes | 9.4 lux (Lux) | CRTU |
| 124 | Logic A | Output (2 byte) | 2 Bytes | DPT.7 | CRTU |
| 125 | Logic A | Jamming | 1 Bit | 1.2 boolean | CRWU |
| 125 | Logic A | Copy Disable (if 1) | 1 Bit | 1.2 boolean | CRWU |
| 125 | Logic A | Copy Disable (if 0) | 1 Bit | 1.2 boolean | CRWU |
| 126 | Logic B | Input 1 | 1 Bit | 1.2 boolean | CWTU |
| 126 | Logic B | Input DPT1 (1 bit) | 1 Bit | DPT.1 | CWTU |
| 126 | Logic B | Input 1 (inverted) | 1 Bit | 1.2 boolean | CWTU |
| 127 | Logic B | Input 2 | 1 Bit | 1.2 boolean | CWTU |
| 127 | Logic B | Input 2 (inverted) | 1 Bit | 1.2 boolean | CWTU |
| 128 | Logic B | Input 3 | 1 Bit | 1.2 boolean | CWTU |
| 128 | Logic B | Input 3 (inverted) | 1 Bit | 1.2 boolean | CWTU |
| 129 | Logic B | Input 4 | 1 Bit | 1.2 boolean | CWTU |
| 129 | Logic B | Input 4 (inverted) | 1 Bit | 1.2 boolean | CWTU |
| 130 | Logic B | Input DPT2 (2 bit) | 2 Bit | DPT.2 | CWTU |
| 131 | Logic B | Input DPT3 (4 bit) | 4 Bit | DPT.3 | CWTU |
| 132 | Logic B | Input (1 byte) | 1 Byte | DPT.5 | CWTU |
| 133 | Logic B | Input (2 byte) | 2 Bytes | DPT.7 | CWTU |
| 134 | Logic B | ON / OFF | 1 Bit | 1.1 switch | CRTU |
| 134 | Logic B | Output DPT1 (1 bit) | 1 Bit | DPT.1 | CRTU |
| 135 | Logic B | Output DPT2 (2 bit) | 2 Bit | DPT.2 | CRTU |
| 136 | Logic B | Output DPT3 (4 bit) | 4 Bit | DPT.3 | CRTU |
| 137 | Logic B | Scene | 1 Byte | 17.1 scene number | CRTU |
| 137 | Logic B | Percentage | 1 Byte | 5.1 percentage (0..100%) | CRTU |
| 137 | Logic B | Angle | 1 Byte | 5.3 angle (degrees) | CRTU |
| 137 | Logic B | Output (1 byte) | 1 Byte | DPT.5 | CRTU |
| 138 | Logic B | Temperature | 2 Bytes | 9.1 temperature (°C) | CRTU |
| 138 | Logic B | Luminosity | 2 Bytes | 9.4 lux (Lux) | CRTU |
| 138 | Logic B | Output (2 byte) | 2 Bytes | DPT.7 | CRTU |
| 139 | Logic B | Jamming | 1 Bit | 1.2 boolean | CRWU |
| 139 | Logic B | Copy Disable (if 1) | 1 Bit | 1.2 boolean | CRWU |
| 139 | Logic B | Copy Disable (if 0) | 1 Bit | 1.2 boolean | CRWU |
| 140 | Logic C | Input 1 | 1 Bit | 1.2 boolean | CWTU |
| 140 | Logic C | Input DPT1 (1 bit) | 1 Bit | DPT.1 | CWTU |
| 140 | Logic C | Input 1 (inverted) | 1 Bit | 1.2 boolean | CWTU |
| 141 | Logic C | Input 2 | 1 Bit | 1.2 boolean | CWTU |
| 141 | Logic C | Input 2 (inverted) | 1 Bit | 1.2 boolean | CWTU |
| 142 | Logic C | Input 3 | 1 Bit | 1.2 boolean | CWTU |
| 142 | Logic C | Input 3 (inverted) | 1 Bit | 1.2 boolean | CWTU |
| 143 | Logic C | Input 4 | 1 Bit | 1.2 boolean | CWTU |
| 143 | Logic C | Input 4 (inverted) | 1 Bit | 1.2 boolean | CWTU |
| 144 | Logic C | Input DPT2 (2 bit) | 2 Bit | DPT.2 | CWTU |
| 145 | Logic C | Input DPT3 (4 bit) | 4 Bit | DPT.3 | CWTU |
| 146 | Logic C | Input (1 byte) | 1 Byte | DPT.5 | CWTU |
| 147 | Logic C | Input (2 byte) | 2 Bytes | DPT.7 | CWTU |
| 148 | Logic C | ON / OFF | 1 Bit | 1.1 switch | CRTU |
| 148 | Logic C | Output DPT1 (1 bit) | 1 Bit | DPT.1 | CRTU |
| 149 | Logic C | Output DPT2 (2 bit) | 2 Bit | DPT.2 | CRTU |
| 150 | Logic C | Output DPT3 (4 bit) | 4 Bit | DPT.3 | CRTU |
| 151 | Logic C | Scene | 1 Byte | 17.1 scene number | CRTU |
| 151 | Logic C | Percentage | 1 Byte | 5.1 percentage (0..100%) | CRTU |
| 151 | Logic C | Angle | 1 Byte | 5.3 angle (degrees) | CRTU |
| 151 | Logic C | Output (1 byte) | 1 Byte | DPT.5 | CRTU |
| 152 | Logic C | Temperature | 2 Bytes | 9.1 temperature (°C) | CRTU |
| 152 | Logic C | Luminosity | 2 Bytes | 9.4 lux (Lux) | CRTU |
| 152 | Logic C | Output (2 byte) | 2 Bytes | DPT.7 | CRTU |
| 153 | Logic C | Jamming | 1 Bit | 1.2 boolean | CRWU |
| 153 | Logic C | Copy Disable (if 1) | 1 Bit | 1.2 boolean | CRWU |
| 153 | Logic C | Copy Disable (if 0) | 1 Bit | 1.2 boolean | CRWU |
| 154 | Logic D | Input 1 | 1 Bit | 1.2 boolean | CWTU |
| 154 | Logic D | Input DPT1 (1 bit) | 1 Bit | DPT.1 | CWTU |
| 154 | Logic D | Input 1 (inverted) | 1 Bit | 1.2 boolean | CWTU |
| 155 | Logic D | Input 2 | 1 Bit | 1.2 boolean | CWTU |
| 155 | Logic D | Input 2 (inverted) | 1 Bit | 1.2 boolean | CWTU |
| 156 | Logic D | Input 3 | 1 Bit | 1.2 boolean | CWTU |
| 156 | Logic D | Input 3 (inverted) | 1 Bit | 1.2 boolean | CWTU |
| 157 | Logic D | Input 4 | 1 Bit | 1.2 boolean | CWTU |
| 157 | Logic D | Input 4 (inverted) | 1 Bit | 1.2 boolean | CWTU |
| 158 | Logic D | Input DPT2 (2 bit) | 2 Bit | DPT.2 | CWTU |
| 159 | Logic D | Input DPT3 (4 bit) | 4 Bit | DPT.3 | CWTU |
| 160 | Logic D | Input (1 byte) | 1 Byte | DPT.5 | CWTU |
| 161 | Logic D | Input (2 byte) | 2 Bytes | DPT.7 | CWTU |
| 162 | Logic D | ON / OFF | 1 Bit | 1.1 switch | CRTU |
| 162 | Logic D | Output DPT1 (1 bit) | 1 Bit | DPT.1 | CRTU |
| 163 | Logic D | Output DPT2 (2 bit) | 2 Bit | DPT.2 | CRTU |
| 164 | Logic D | Output DPT3 (4 bit) | 4 Bit | DPT.3 | CRTU |
| 165 | Logic D | Scene | 1 Byte | 17.1 scene number | CRTU |
| 165 | Logic D | Percentage | 1 Byte | 5.1 percentage (0..100%) | CRTU |
| 165 | Logic D | Angle | 1 Byte | 5.3 angle (degrees) | CRTU |
| 165 | Logic D | Output (1 byte) | 1 Byte | DPT.5 | CRTU |
| 166 | Logic D | Temperature | 2 Bytes | 9.1 temperature (°C) | CRTU |
| 166 | Logic D | Luminosity | 2 Bytes | 9.4 lux (Lux) | CRTU |
| 166 | Logic D | Output (2 byte) | 2 Bytes | DPT.7 | CRTU |
| 167 | Logic D | Jamming | 1 Bit | 1.2 boolean | CRWU |
| 167 | Logic D | Copy Disable (if 1) | 1 Bit | 1.2 boolean | CRWU |
| 167 | Logic D | Copy Disable (if 0) | 1 Bit | 1.2 boolean | CRWU |
| 172 | Thermostat | Temperature Indication | 2 Bytes | 9.1 temperature (°C) | CRTU |
| 173 | Thermostat | Temperature (external source) | 2 Bytes | 9.1 temperature (°C) | CWTU |
| 174 | Thermostat | Heating / Cooling Indication | 1 Bit | 1.100 cooling/heating | CRTU |
| 175 | Thermostat | Heating / Cooling | 1 Bit | 1.100 cooling/heating | CWTU |
| 176 | Thermostat | Comfort Mode Trigger | 1 Bit | 1.1 switch | CWTU |
| 177 | Thermostat | StandBy Mode Trigger | 1 Bit | 1.1 switch | CWTU |
| 178 | Thermostat | Economy Mode Trigger | 1 Bit | 1.1 switch | CWTU |
| 179 | Thermostat | Building Protection Trigger | 1 Bit | 1.1 switch | CWTU |
| 180 | Thermostat | Mode (next/previous) | 1 Bit | 1.8 up/down | CWTU |
| 181 | Thermostat | Mode Indication | 1 Byte | 20.102 HVAC mode | CRTU |
| 182 | Thermostat | Comfort Mode Ind. | 1 Bit | 1.3 enable | CRTU |
| 183 | Thermostat | StandBy Mode Ind. | 1 Bit | 1.3 enable | CRTU |
| 184 | Thermostat | Economy Mode Ind. | 1 Bit | 1.3 enable | CRTU |
| 185 | Thermostat | Building Protection Ind. | 1 Bit | 1.3 enable | CRTU |
| 186 | Thermostat | Mode | 1 Byte | 20.102 HVAC mode | CWTU |
| 187 | Thermostat | Force Mode | 1 Byte | 20.102 HVAC mode | CWTU |
| 188 | Thermostat | Time Limited Comfort | 1 Bit | 1.1 switch | CWTU |
| 189 | Thermostat | Presence Detector Input | 1 Bit | 1.2 boolean | CWTU |
| 190 | Thermostat | Forced Building Protection | 1 Bit | 1.2 boolean | CWTU |
| 191 | Thermostat | Window Status | 1 Bit | 1.9 open/close | CWTU |
| 192 | Thermostat | Current Setpoint Temp. Ind. | 2 Bytes | 9.1 temperature (°C) | CRTU |
| 193 | Thermostat | Current Setpoint Temperature | 2 Bytes | 9.1 temperature (°C) | CWTU |
| 194 | Thermostat | Current Setpoint Temp. Step | 1 Bit | 1.8 up/down | CWTU |
| 195 | Thermostat | Heating Setpoint Temp. Ind. | 2 Bytes | 9.1 temperature (°C) | CRTU |
| 196 | Thermostat | Cooling Setpoint Temp. Ind. | 2 Bytes | 9.1 temperature (°C) | CRTU |
| 197 | Thermostat | Outdoor Temperature Input | 2 Bytes | 9.1 temperature (°C) | CWTU |
| 198 | Thermostat | Spot Temperature (Heating) | 2 Bytes | 9.1 temperature (°C) | CWTU |
| 199 | Thermostat | Spot Temperature (Cooling) | 2 Bytes | 9.1 temperature (°C) | CWTU |
| 200 | Thermostat | Internal Sensor Value Ind. | 2 Bytes | 9.1 temperature (°C) | CRTU |
| 201 | Thermostat | Scene | 1 Byte | 17.1 scene number | CWTU |
| 202 | Thermostat | Controller Status Indication | 2 Bytes | 22.101 RHCC status | CRTU |
| 204 | Thermostat | Jamming | 1 Bit | 1.3 enable | CWTU |
| 205 | Thermostat | Frost Alarm Indication | 1 Bit | 1.2 boolean | CRTU |
| 206 | Thermostat | Heat Alarm Indication | 1 Bit | 1.2 boolean | CRTU |
| 207 | Thermostat | Base Temperature Indication | 2 Bytes | 9.1 temperature (°C) | CRTU |
| 208 | Thermostat | Base Temperature | 2 Bytes | 9.1 temperature (°C) | CWTU |
| 209 | Thermostat | Base Temperature Step | 1 Bit | 1.8 up/down | CWTU |
| 210 | Heater | Stop | 1 Bit | 1.2 boolean | CWTU |
| 210 | Comb. (Heat/Cool) | Stop | 1 Bit | 1.2 boolean | CWTU |
| 211 | Heater | Heater control | 1 Bit | 1.1 switch | CRTU |
| 211 | Comb. (Heat/Cool) | Comb. control | 1 Bit | 1.1 switch | CRTU |
| 212 | Heater | Heater control | 1 Byte | 5.1 percentage (0..100%) | CRTU |
| 212 | Comb. (Heat/Cool) | Comb. Control | 1 Byte | 5.1 percentage (0..100%) | CRTU |
| 213 | Heater | Fan Speed 1 | 1 Bit | 1.1 switch | CRTU |
| 213 | Comb. (Heat/Cool) | Fan Speed 1 | 1 Bit | 1.1 switch | CRTU |
| 214 | Heater | Fan Speed 2 | 1 Bit | 1.1 switch | CRTU |
| 214 | Comb. (Heat/Cool) | Fan Speed 2 | 1 Bit | 1.1 switch | CRTU |
| 215 | Heater | Fan Speed 3 | 1 Bit | 1.1 switch | CRTU |
| 215 | Comb. (Heat/Cool) | Fan Speed 3 | 1 Bit | 1.1 switch | CRTU |
| 216 | Heater | Fan Speed (%) | 1 Byte | 5.1 percentage (0..100%) | CRTU |
| 216 | Comb. (Heat/Cool) | Fan Speed (%) | 1 Byte | 5.1 percentage (0..100%) | CRTU |
| 217 | Supp. Heater | Stop | 1 Bit | 1.2 boolean | CWTU |
| 217 | Supp. Comb. | Stop | 1 Bit | 1.2 boolean | CWTU |
| 218 | Supp. Heater | Supplementary Heater control | 1 Bit | 1.1 switch | CRTU |
| 218 | Supp. Comb. | Supplementary Comb. control | 1 Bit | 1.1 switch | CRTU |
| 219 | Supp. Heater | Supplementary Heater control | 1 Byte | 5.1 percentage (0..100%) | CRTU |
| 219 | Supp. Comb. | Supplementary Comb. control | 1 Byte | 5.1 percentage (0..100%) | CRTU |
| 220 | Cooler | Stop | 1 Bit | 1.2 boolean | CWTU |
| 221 | Cooler | Cooler Control | 1 Bit | 1.1 switch | CRTU |
| 222 | Cooler | Cooler Control | 1 Byte | 5.1 percentage (0..100%) | CRTU |
| 223 | Cooler | Fan Speed 1 | 1 Bit | 1.1 switch | CRTU |
| 224 | Cooler | Fan Speed 2 | 1 Bit | 1.1 switch | CRTU |
| 225 | Cooler | Fan Speed 3 | 1 Bit | 1.1 switch | CRTU |
| 226 | Cooler | Fan Speed (%) | 1 Byte | 5.1 percentage (0..100%) | CRTU |
| 227 | Supp. Cooler | Stop | 1 Bit | 1.2 boolean | CWTU |
| 228 | Supp. Cooler | Supplementary Cooler control | 1 Bit | 1.1 switch | CRTU |
| 229 | Supp. Cooler | Supplementary Cooler control | 1 Byte | 5.1 percentage (0..100%) | CRTU |
| 230 | Fan Control | Enable Auto. 0-Man/1-Auto | 1 Bit | 1.2 boolean | CWTU |
| 231 | Fan Control | Speed Step | 1 Bit | 1.8 up/down | CWTU |
| 232 | Fan Control | Set Speed (%) | 1 Byte | 5.1 percentage (0..100%) | CWTU |
| 233 | Fan Control | Auto. 0-Man/1-Auto indication | 1 Bit | 1.2 boolean | CRTU |
Parameters (223)
| Parameter | Type | Default |
|---|---|---|
| Duration of long key press for Dimming and Shutter/Blinds operation (ms) | unsignedInt 0…12500 | 500 |
| Duration of long key press for 2-Channel mode operation (ms) | unsignedInt 0…12500 | 1000 |
| Duration of LED key press confirmation (s) | unsignedInt 0…65535 | 5 |
| Application Version | text | V0.0.1 |
| Function | list | Button not used |
| Press / Release | list | ON / OFF |
| None | unsignedInt 0…0 | 0 |
| Press / Release | list | Toggle / - |
| 1 button dimming | unsignedInt 0…255 | 11 |
| Mode | list | 1 Button Dimmer |
| Direction | list | Increase |
| Mode | list | 1 Button Shutter/Blinds |
| 1 button | unsignedInt 0…255 | 14 |
| Direction | list | Up |
| Value | list | Auto |
| Scene Number | list | Scene 1 |
| Mode | list | Send Scene |
| Value Type | list | Percentage |
| Luminosity (lux) | list | 0 lux |
| Temperature | list | 0 °C |
| Channel A (Short) / Channel B (Long) | list | Toggle / Toggle |
| LED Usage | list | OFF |
| Jamming | list | Not used |
| Emission Delay (s) | unsignedInt 0…65535 | 0 |
| Mode | list | 1 channel mode |
| Value | list | Priority OFF |
| Short Press / Long Press | list | OFF / Prio. OFF |
| Percentage (%) | list | 0.0% | 0x00 |
| Angle (°) | list | 00.00 ° | 0x00 |
| Mode | list | Send Value |
| Emission delay cancellable by second press? | list | No |
| Behavior at Power up | list | Don't read objects |
| Function | list | Switch (ON/OFF) |
| none | unsignedInt 0…0 | 0 |
| scene | unsignedInt 26…26 | 26 |
| Logic Channel A | list | Not used |
| Logic Operation | list | And |
| Input 1 | list | Disabled |
| Input 2 | list | Disabled |
| Input 3 | list | Disabled |
| Input 4 | list | Disabled |
| func onoff | unsignedInt 1…1 | 1 |
| Send Condition | list | When result changes |
| Debounce Time (s) | unsignedInt 0…255 | 0 |
| Copy and forward an object | unsignedInt 53…53 | 53 |
| 1 Bit Copy | list | Not used |
| 2 Bit Copy | list | Not used |
| 4 Bit Copy | list | Not used |
| 1 Byte Copy | list | Not used |
| 2 Byte Copy | list | Not used |
| Disable copy | list | Not used |
| Emission Delay (s) (Attention: See the product manual) | unsignedInt 0…65535 | 0 |
| Logic Channel B | list | Not used |
| Logic Channel C | list | Not used |
| Logic Channel D | list | Not used |
| Heating Type | list | HVAC |
| Initial Result Status | list | FALSE |
| Apply jamming to | list | Jamming Output |
| Dimming Step | list | 100 % |
| Repetition Period | list | Don't Repeat |
| When Copy Re-enabled | list | Do nothing |
| PID_HardwareType | list | HARDWARE_TYPE |
| HVAC installation type | list | Heating |
| Changeover Cooling/Heating | list | Automatic |
| The source of the Room temperature | list | Internal Sensor |
| Make Read Request to external source? | list | No |
| Use valve protection? | list | No |
| Aperture angle to open and close(º) | unsignedInt 1…15 | 5 |
| Time of inactivity before open and close | list | approx. 12 hours |
| Internal sensor calibration (10 = 1°C) | signedInt -100…100 | 0 |
| Time Limited Comfort Usage | list | 1 h |
| Send Thermostat's Status COs every (min) (0 = never send) | unsignedInt 0…255 | 0 |
| Temperature Increase for Economy mode | list | 2.0 °C |
| Temperature Increase for Standby | list | 4.0 °C |
| Bluiding Heating protection temperature | list | 37.0 °C |
| Bluiding Frost protection temperature | list | 3.0 °C |
| Temperature Decrease for Standby | list | 4.0 °C |
| Temperature Decrease for Economy mode | list | 2.0 °C |
| Controller type | list | ON-OFF controller |
| Use cooling supplementary system | list | No |
| Use heating supplementary system | list | No |
| Supplementary controller type | list | ON-OFF controller |
| Supplementary control type | list | ON-OFF controller |
| Difference between "main" and "supplementary" setpoint | list | 2.0 °C |
| NOTE: If not acquainted to the PID parameters representation, please | text | |
| refer to the device's manual. | text | |
| Cooling PID Parameters SETUP: | text | |
| Supplementary Cooling PID Parameters SETUP: | text | |
| Heating PID Parameters SETUP: | text | |
| Supplementary Heating PID Parameters SETUP: | text | |
| Proportional band / Gain (Kp) (1%/1°C) | unsignedInt 0…255 | 20 |
| Integration time (Ti) (minutes) | unsignedInt 0…255 | 100 |
| Derivative time (Td) (minutes) | unsignedInt 0…255 | 0 |
| Use outdoor temperature for limiting used power? | list | No |
| Use spot limit temperature? | list | No |
| Delta set (°C) | list | 2.0 °C |
| Fluctuation range (°C) | list | 25.0 °C |
| Spot's minimum temperature | list | 10.0 °C |
| Spot's maximum temperature | list | 35.0 °C |
| Fan usage on cooling | list | Automatic |
| Fan usage on heating | list | Automatic |
| Use fan protection? | list | No |
| Duration of fan in max speed (s) | unsignedInt 1…15 | 3 |
| Time of inactivity before starting and stopping the fan | list | approx. 1 day |
| Mode for scene 1 | list | Don't react |
| Mode for scene 2 | list | Don't react |
| Mode for scene 3 | list | Don't react |
| Mode for scene 5 | list | Don't react |
| Mode for scene 4 | list | Don't react |
| Mode for scene 6 | list | Don't react |
| Mode for scene 7 | list | Don't react |
| Mode for scene 8 | list | Don't react |
| Mode for scene 9 | list | Don't react |
| Mode for scene 10 | list | Don't react |
| Mode for scene 11 | list | Don't react |
| Mode for scene 12 | list | Don't react |
| Mode for scene 13 | list | Don't react |
| Mode for scene 14 | list | Don't react |
| Mode for scene 15 | list | Don't react |
| Mode for scene 16 | list | Don't react |
| Mode for scene 17 | list | Don't react |
| Mode for scene 18 | list | Don't react |
| Mode for scene 19 | list | Don't react |
| Mode for scene 20 | list | Don't react |
| Mode for scene 21 | list | Don't react |
| Mode for scene 22 | list | Don't react |
| Mode for scene 23 | list | Don't react |
| Mode for scene 24 | list | Don't react |
| Mode for scene 25 | list | Don't react |
| Mode for scene 26 | list | Don't react |
| Mode for scene 27 | list | Don't react |
| Mode for scene 28 | list | Don't react |
| Mode for scene 29 | list | Don't react |
| Mode for scene 30 | list | Don't react |
| Mode for scene 31 | list | Don't react |
| Mode for scene 32 | list | Don't react |
| Mode for scene 33 | list | Don't react |
| Mode for scene 34 | list | Don't react |
| Mode for scene 35 | list | Don't react |
| Mode for scene 36 | list | Don't react |
| Mode for scene 37 | list | Don't react |
| Mode for scene 38 | list | Don't react |
| Mode for scene 39 | list | Don't react |
| Mode for scene 40 | list | Don't react |
| Mode for scene 41 | list | Don't react |
| Mode for scene 42 | list | Don't react |
| Mode for scene 43 | list | Don't react |
| Mode for scene 44 | list | Don't react |
| Mode for scene 45 | list | Don't react |
| Mode for scene 46 | list | Don't react |
| Mode for scene 47 | list | Don't react |
| Mode for scene 48 | list | Don't react |
| Mode for scene 49 | list | Don't react |
| Mode for scene 50 | list | Don't react |
| Mode for scene 51 | list | Don't react |
| Mode for scene 52 | list | Don't react |
| Mode for scene 53 | list | Don't react |
| Mode for scene 54 | list | Don't react |
| Mode for scene 55 | list | Don't react |
| Mode for scene 56 | list | Don't react |
| Mode for scene 57 | list | Don't react |
| Mode for scene 58 | list | Don't react |
| Mode for scene 59 | list | Don't react |
| Mode for scene 60 | list | Don't react |
| Mode for scene 61 | list | Don't react |
| Mode for scene 62 | list | Don't react |
| Mode for scene 63 | list | Don't react |
| Mode for scene 64 | list | Don't react |
| Allow to save scenes via "learn scene" request? | list | No |
| Distance between decision levels (10 = 1°C) | unsignedInt 0…255 | 30 |
| Initial operating mode | list | Wait for bus response |
| Hysteresis (10 = 1°C) | unsignedInt 1…255 | 5 |
| Hysteresis (10 = 1°C) | unsignedInt 1…255 | 10 |
| Threshold to set from Off to Speed 1 (10=1°C) | unsignedInt 0…100 | 1 |
| Threshold to set from Speed 1 to 2 (10=1°C) | unsignedInt 0…100 | 30 |
| Threshold to set from Speed 2 to 3 (10=1°C) | unsignedInt 0…100 | 60 |
| Hysteresis between threshold values (10=1°C) | unsignedInt 0…100 | 5 |
| Threshold to set from Off to Speed 1 (%) | unsignedInt 0…100 | 1 |
| Threshold to set from Speed 1 to 2 (%) | unsignedInt 0…100 | 30 |
| Threshold to set from Speed 2 to 3 (%) | unsignedInt 0…100 | 60 |
| Hysteresis between threshold values (%) | unsignedInt 0…100 | 5 |
| Time between speed switch (10 = 1s) | unsignedInt 0…255 | 10 |
| Maximum deviation (+/-°C) | unsignedInt 0…15 | 3 |
| Modification via CO | list | Permanent change of setpoint |
| Emission of control value | list | approx. 1% |
| Controller execution period | list | 30 sec |
| Setpoint Temperature | list | 24.0 °C |
| Switchover trigger | list | Room Temperature |
| Enter Cooling when outdoor is | list | 28.0 °C |
| Enter Heating when outdoor is | list | 14.0 °C |
| Over-Heat Alarm Temperature | list | 40.0 °C |
| Frost Alarm Temperature | list | 0 °C |
| SET_NEW_PARAMS_FLAGS | list | SET_ALL_NEW |
| Allow Fan's Man. control when available? | list | Don't allow |
| Manual Fan Control step value | list | 33.7% | 0x56 (3 Speed Fan) |
| Manual Fan Controll step rollover allowed (at upper/lower limit)? | list | Not allowed |
| Use time limited Comfort mode | list | No |
| _Th_TimeLimitedComfortUsage:NOT_USED | unsignedInt 0…255 | 0 |
| Use Over-Heat and Freeze alarms? | list | No |
| HVAC Mode Control Interfaces | text | |
| Use 1bit Enable CO per Mode? | list | Yes |
| Use Next/Prev Mode CO (1bit)? | list | No |
| Use HVAC Mode CO (1byte)? | list | Yes |
| Use Presence Detector? | list | No |
| Use 'Force Building Protection' Comm. Obj.? | list | No |
| Use 'Window Status' Com. Obj.? | list | No |
| Use fan in cooling | list | No |
| Th_AC_FanUsage:NOT_USED | unsignedInt 0…255 | 0 |
| Use fan in heating | list | No |
| Th_FanUsage:NOT_USED | unsignedInt 0…255 | 0 |
| Th_FrostAlarm:NOT_USED | unsignedInt 0…65535 | 0 |
| Th_FrostAlarm:NOT_USED | unsignedInt 0…65535 | 5221 |
| Messages to block | list | Block Sending |
| After Jamming | list | Do nothing |
| Th_AC_Heat_swov_NONE | unsignedInt 0…3 | 0 |
| Send temperature value when changes more than (10=1°C; 0->never) | unsignedInt 0…50 | 5 |
| LED Color | text | |
| Color On | list | White |
| Color Off | list | Off |
| Setpoint Temperature Step | list | 0.5 °C |
| Brightness of LED when key is pressed. | list | %100 |
| Brightness of LED when key is released. | list | %100 |
| Button Count | list | 8 Button |
Version history
| Application | App no | Fingerprint | First seen | Size | File |
|---|---|---|---|---|---|
| MSW100x-MPL-T_v1.1_349a6d5 1.1 latest | $300F | E867 | 2026-11-25 | 300 KB | Download |
About this file
This is the official ETS product database for the Makel Elektrik Modular Push Button with Thermostat (MSW100x-MPL-T), published by the manufacturer in the KNX online catalog. To use it, open ETS, go to Catalogs → Import and choose the downloaded .knxprod file. The device then appears in your catalog and can be added to a project. Older versions are kept so existing projects can be matched to the application program they were commissioned with.
More from Makel Elektrik
- KNX Touch Button with Thermostat MSW100x-Tx
- KNX DALI Gateway (1/2 Channels) MKD1002
- 8 output Switch Actuator | Shutter Blinds MSA08yy-CM
- Thermostat+6-fold Push Button MTH1006-PL