Lithoss K1 yyK1xx

Lithoss Design Switches · Order number yyK1xx · Push Buttons › 1 Channel

1 channel

Download .knxprod yyK1xx 1.0 · 95 KB

Product

ManufacturerLithoss Design Switches
Product nameLithoss K1
Order numberyyK1xx
Product text1 channel
HardwareyyK1xx
MediumTwisted Pair
Bus current (mA)10
Rail mountedNo
RegistrationRegistered · 2016-11-04
Languagesen-US
Catalog entryM-00B1_H-yyK1xx-1-O006C_HP-006C-10-956D-O006C_CI-yyK1xx-1
Fingerprint956D
SHA-256cd65171fb11933079588ce7e82909bb6cfa802b4b40feb7a792045d1aca34c7c
First seen2026-11-25
MarketsBelgium, France, Netherlands

Application program: yyK1xx 1.0

Application number$006C
Version1.0
Mask versionMV-0021 (2.1)
KNX Data SecureNo
Minimum ETS version3.0
Parameters191
Group objects101
Group objects (101)
NoNameFunctionSizeDPTFlags
0<Button> FeedbackOff/On1 Bit1.1 switchCW
0<Button> Sequence Command A Off/On1 Bit1.1 switchCRT
0<Button> Sequence Command A 0-2551 Byte5.10 counter pulses (0..255)CRT
0<Button> Sequence Command A 0-100%1 Byte5.1 percentage (0..100%)CRT
0<Button> Sequence Command A HVAC Mode1 ByteCRT
4<Temp Sensor Ext> T. Sensor - Trigger T1Off/On1 Bit1.1 switchCRT
4<Temp Sensor Ext> Thermostat - Heat/Cool ModeHeat/Cool1 BitCW
4<Temp Sensor Ext> Thermostat - Heat/Cool StatusHeat/Cool1 BitCRT
5<Temp Sensor Int> T. Sensor - Trigger T1Off/On1 Bit1.1 switchCRT
5<Temp Sensor Int> Thermostat - Heat/Cool ModeHeat/Cool1 BitCW
5<Temp Sensor Int> Thermostat - Heat/Cool StatusHeat/Cool1 BitCRT
6<Output Led> LedOff/On/Blink1 Bit1.1 switchCW
8<Button> EdgeOff/On1 Bit1.1 switchCRWT
8<Button> Edge 0-2551 Byte5.10 counter pulses (0..255)CRT
8<Button> Edge 0-100%1 Byte5.1 percentage (0..100%)CRT
8<Button> Edge HVAC Mode1 ByteCRT
8<Button> Short - Long PressOff/On1 Bit1.1 switchCRWT
8<Button> Value SendingHVAC Mode1 ByteCRT
8<Button> Value Sending0-100%1 Byte5.1 percentage (0..100%)CRT
8<Button> Value Sending0-2551 Byte5.10 counter pulses (0..255)CRT
8<Button> Sequence Command BOff/On1 Bit1.1 switchCRT
8<Button> Sequence Command B0-2551 Byte5.10 counter pulses (0..255)CRT
8<Button> Sequence Command B0-100%1 Byte5.1 percentage (0..100%)CRT
8<Button> Sequence Command BHVAC Mode1 ByteCRT
8<Button> Dimmer On/OffOff/On1 Bit1.1 switchCRWT
8<Button> ShutterUp/Down1 Bit1.8 up/downCRWT
8<Button> Recall/Learn SceneScene1 ByteCRT
12<Temp Sensor Ext> Enable Trigger T1/T2Disable/Enable1 Bit1.3 enableCW
12<Temp Sensor Ext> Thermostat - Window ContactClose/Open1 BitCW
13<Temp Sensor Int> Enable Trigger T1/T2Disable/Enable1 Bit1.3 enableCW
13<Temp Sensor Int> Thermostat - Window ContactClose/Open1 BitCW
16<Button> Long PressOff/On1 Bit1.1 switchCRWT
16<Button> Long Press0-2551 Byte5.10 counter pulses (0..255)CRT
16<Button> Long Press0-100%1 Byte5.1 percentage (0..100%)CRT
16<Button> Long PressHVAC Mode1 ByteCRT
16<Button> Sequence Command COff/On1 Bit1.1 switchCRT
16<Button> Sequence Command C0-2551 Byte5.10 counter pulses (0..255)CRT
16<Button> Sequence Command C0-100%1 Byte5.1 percentage (0..100%)CRT
16<Button> Sequence Command CHVAC Mode1 ByteCRT
16<Button> DimmingDimming Control4 Bit3.7 dimming controlCRT
16<Button> ShutterStep/Stop1 BitCRT
16<Button> Send Learn Scene TriggerDisable/Enable1 BitCW
20<Temp Sensor Ext> T. Sensor - Trigger T2Off/On1 Bit1.1 switchCRT
20<Temp Sensor Ext> Thermostat - Comfort ModeDisable/Enable1 Bit1.1 switchCW
21<Temp Sensor Int> T. Sensor - Trigger T2Off/On1 Bit1.1 switchCRT
21<Temp Sensor Int> Thermostat - Comfort ModeDisable/Enable1 Bit1.1 switchCW
28<Temp Sensor Ext> Thermostat - HVAC ModeComf/Standby/Eco/B. protection1 ByteCW
28<Temp Sensor Ext> Thermostat - Base SetpointValue °C2 Bytes9.1 temperature (°C)CRW
29<Temp Sensor Int> Thermostat - HVAC ModeComf/Standby/Eco/B. protection1 ByteCW
29<Temp Sensor Int> Thermostat - Base SetpointValue °C2 Bytes9.1 temperature (°C)CRW
30<Temp Sensor Ext> Thermostat - Actual Setpoint Value °C2 Bytes9.1 temperature (°C)CRT
30<Temp Sensor Ext> Thermostat - Actual SetpointValue °C2 Bytes9.1 temperature (°C)CRT
31<Temp Sensor Int> Thermostat - Actual Setpoint Value °C2 Bytes9.1 temperature (°C)CRT
31<Temp Sensor Int> Thermostat - Actual SetpointValue °C2 Bytes9.1 temperature (°C)CRT
32<Temp Sensor Ext> T. Sensor - Actual TemperatureValue °C2 Bytes9.1 temperature (°C)CRT
32<Temp Sensor Ext> Thermostat - Actual TemperatureValue °C2 Bytes9.1 temperature (°C)CRT
33<Temp Sensor Int> T. Sensor - Actual TemperatureValue °C2 Bytes9.1 temperature (°C)CRT
33<Temp Sensor Int> Thermostat - Actual TemperatureValue °C2 Bytes9.1 temperature (°C)CRT
34<Temp Sensor Ext> Thermostat - Extra TemperatureValue °C2 Bytes9.1 temperature (°C)CW
34<Temp Sensor Ext> Thermostat - Setpoint ComfortValue °C2 Bytes9.1 temperature (°C)CW
34<Temp Sensor Ext> Thermostat - Setpoint ComfortValue °C2 Bytes9.1 temperature (°C)CWT
35<Temp Sensor Int> Thermostat - Extra TemperatureValue °C2 Bytes9.1 temperature (°C)CW
35<Temp Sensor Int> Thermostat - Setpoint ComfortValue °C2 Bytes9.1 temperature (°C)CW
35<Temp Sensor Int> Thermostat - Setpoint ComfortValue °C2 Bytes9.1 temperature (°C)CWT
36<Temp Sensor Ext> Fan Coil Valve Heat/CoolOff/On1 Bit1.1 switchCRT
36<Temp Sensor Ext> Thermostat - On/Off HeatingOff/On1 Bit1.1 switchCRT
36<Temp Sensor Ext> Heating ValveOff/On1 Bit1.1 switchCRT
36<Temp Sensor Ext> Heating/Cooling ValveOff/On1 Bit1.1 switchCRT
37<Temp Sensor Int> Fan Coil Valve Heat/CoolOff/On1 Bit1.1 switchCRT
37<Temp Sensor Int> Thermostat - On/Off HeatingOff/On1 Bit1.1 switchCRT
37<Temp Sensor Int> Heating ValveOff/On1 Bit1.1 switchCRT
37<Temp Sensor Int> Heating/Cooling ValveOff/On1 Bit1.1 switchCRT
38<Temp Sensor Ext> Thermostat - On/Off CoolingOff/On1 Bit1.1 switchCRT
38<Temp Sensor Ext> Cooling ValveOff/On1 Bit1.1 switchCRT
39<Temp Sensor Int> Thermostat - On/Off CoolingOff/On1 Bit1.1 switchCRT
39<Temp Sensor Int> Cooling ValveOff/On1 Bit1.1 switchCRT
40<Temp Sensor Ext> Fan Coil Speed 1Off/On1 Bit1.1 switchCRT
40<Temp Sensor Ext> Continuous Control %0-100%1 Byte5.1 percentage (0..100%)CRT
41<Temp Sensor Ext> Fan Coil Speed 2Off/On1 Bit1.1 switchCRT
41<Temp Sensor Ext> Set Man/Auto ModeManual (0) / Auto (1)1 BitCW
42<Temp Sensor Ext> Fan Coil Speed 3Off/On1 Bit1.1 switchCRT
42<Temp Sensor Ext> Force Value in Manual Mode 0-100%1 Byte5.1 percentage (0..100%)CW
43<Temp Sensor Int> Fan Coil Speed 1Off/On1 Bit1.1 switchCRT
43<Temp Sensor Int> Continuous Control %0-100%1 Byte5.1 percentage (0..100%)CRT
44<Temp Sensor Int> Fan Coil Speed 2Off/On1 Bit1.1 switchCRT
44<Temp Sensor Int> Set Man/Auto ModeManual (0) / Auto (1)1 BitCW
45<Temp Sensor Int> Fan Coil Speed 3Off/On1 Bit1.1 switchCRT
45<Temp Sensor Int> Force Value in Manual Mode 0-100%1 Byte5.1 percentage (0..100%)CW
48<Temp Sensor Ext> Thermostat - Setpoint AdjustmentValue °C2 Bytes9.1 temperature (°C)CW
48<Temp Sensor Ext> Thermostat - Setpoint AdjustmentValue °C1 BitCW
48<Temp Sensor Ext> Thermostat - Setpoint StandbyValue °C2 Bytes9.1 temperature (°C)CW
48<Temp Sensor Ext> Thermostat - Setpoint StandbyValue °C2 Bytes9.1 temperature (°C)CWT
49<Temp Sensor Int> Thermostat - Setpoint AdjustmentValue °C2 Bytes9.1 temperature (°C)CW
49<Temp Sensor Int> Thermostat - Setpoint AdjustmentValue °C1 BitCW
49<Temp Sensor Int> Thermostat - Setpoint StandbyValue °C2 Bytes9.1 temperature (°C)CW
49<Temp Sensor Int> Thermostat - Setpoint StandbyValue °C2 Bytes9.1 temperature (°C)CWT
50<Temp Sensor Ext> Thermostat - Setpoint EconomyValue °C2 Bytes9.1 temperature (°C)CW
50<Temp Sensor Ext> Thermostat - Setpoint EconomyValue °C2 Bytes9.1 temperature (°C)CWT
51<Temp Sensor Int> Thermostat - Setpoint EconomyValue °C2 Bytes9.1 temperature (°C)CW
51<Temp Sensor Int> Thermostat - Setpoint EconomyValue °C2 Bytes9.1 temperature (°C)CWT
52<Temperature Alarm>Alarm1 BitCRT
Parameters (97)
ParameterTypeDefault
Delay to send telegrams on power upunsignedInt 5…155
Button debounce time - buttonlist80 mS
Minimum time long presslist0,5 sec
External temperature sensorlistdisabled
Function external temperature sensorlisttemperature sensor
Internal temperature sensorlistdisabled
Function internal temperature sensorlisttemperature sensor
Object Temperature Alarmlistdisabled
Functionlistnothing
Telegram associatedlist1 bit
Command associated with presslistnothing
Command associated with releaselistnothing
Command typelistvalue 0-255
Value associated with pressunsignedInt 0…2550
Value associated with releaseunsignedInt 0…2550
Value associated with presslist0%
Value associated with releaselist0%
Value associated with presslistAUTO
Value associated with releaselistAUTO
Telegram sendingliston release/press
Sending telegrams every:list5 min
Send telegram on power uplistdisabled
Feedback objectlistdisabled
Command associated with short presslistnothing
Command associated with long presslistnothing
Communication object on long presslistdisabled
Value associated with short pressunsignedInt 0…2550
Value associated with long pressunsignedInt 0…2550
Value associated with short presslist0%
Value associated with long presslist0%
Value associated with short presslistAUTO
Value associated with long presslistAUTO
Telegram associated with command Alist1 bit
Command typelistnothing
Telegram associated with command Blist1 bit
Telegram associated with command Clistnothing
Scene number (0-63)unsignedInt 0…630
Store scene on long presslistdisabled
Enable learn scene objectlistdisabled
Sensor codelistProbe A (-20 to 100°C epoxy)
Temperature sensor calibrationlist0,0 °C
Temperature cyclic sendinglistdisabled
Sending intervallist10 min
Enable threshold T1 (low)listdisabled
Threshold T1list0 °C
Telegram to send when T < T1listtelegram "1"
Enable threshold T2 (high)listdisabled
Threshold T2list0 °C
Telegram to send when T > T2listtelegram "1"
Object enable/disable for trigger 1 and 2listhide
Initial value for object enable(1) /disable(0)list1
Temperature objectlistdisabled
Control algorithmlist2 points on/off control
Thermostat control modelistHVAC mode (switched heat/cool )
Enable setpoint objectslistdisabled
Enabled additional temperature (internal-without CO )listDisabled
Ratio between internal and additional sensorlist50 % internal - 50 % external
Surveillance time for additional sensor (min)unsignedInt 10…25525
Enable additional temperature sensor objectlistdisabled
Minimum valid value for additional probe (°C)signedInt -50…100-50
Maximum valid value for additional probe (°C)signedInt -50…100100
Enable setpoint adjustment objectlistdisabled
Setpoint adjustment value formatlist2 byte object - temperature value
Adjustment allowedlist+/- 3 °C
Keep setpoint adjustment value on power uplistenabled
Window contactlistdisabled
Window contact activation telegramlisttelegram "1"
Object value Heat/Cool after downloadlist1 = Heat
Object value HVAC after downloadlistOFF (antifreeze / high temperature protection)
Setpoint antifreezelist7 °C
Setpoint economy heating (Teh)list16 °C
Setpoint standby heating (Tsh)list18 °C
Setpoint comfort heating (Tch)list20 °C
Setpoint high temperature protectionlist35 °C
Setpoint economy cooling (Tec)list28 °C
Setpoint standby cooling (Tsc)list26 °C
Setpoint comfort cooling (Tcc)list24 °C
Dead zonelist3 °C
Repetition time on/off telegramslistno cyclic sending
Regulation differential value - heatinglist0,4 °C
Regulation differential value - coolinglist0,4 °C
Cycle timelist10 min
Proportional bandlist1,2 °C
System typelist2 pipes
Speed numberlist3 speed
Regulation differential value V1 - heatinglist0,4 °C
Regulation differential value V1 - coolinglist0,4 °C
Regulation differential value V2 - heatinglist0,4 °C
Regulation differential value V2 - coolinglist0,4 °C
Proportional bandlist2 °C
Initial value for MAN (0) / AUTO (1) objectlist1
RGB Led functionlistdisable
Colour RGB Ledlistwhite
LED on Time [0=while pressed / 1..20=1..20 seconds]unsignedInt 0…200
Activation telegramlisttelegram "1"
Functionliston/off
Blinking timelistfast

Version history

ApplicationApp noFingerprintFirst seenSizeFile
yyK1xx 1.0 latest$006C956D2026-11-2595 KBDownload

About this file

This is the official ETS product database for the Lithoss Design Switches Lithoss K1 (yyK1xx), published by the manufacturer in the KNX online catalog. To use it, open ETS, go to Catalogs → Import and choose the downloaded .knxprod file. The device then appears in your catalog and can be added to a project. Older versions are kept so existing projects can be matched to the application program they were commissioned with.