Product
| Manufacturer | LEGRAND Appareillage électrique |
|---|---|
| Product name | KNX-Mallia Senses command 6 push with thermostat brushed black |
| Order number | 281028BB/F0306TKNX |
| Hardware | KNX-Mallia Senses command 6 push with thermostat |
| Medium | Twisted Pair |
| Bus current (mA) | 12 |
| Rail mounted | No |
| Registration | Certified · 2024-01-03 |
| Languages | en-US |
| Catalog entry | M-000B_H-CH21DE-1_HP-0AAF-14-B470_CI-281028BB.2FF0306TKNX-1 |
| Fingerprint | B470 |
| SHA-256 | f394a75c120c6c93936c9288bdcf1db95aba3ee5a0825eb84e98b31e5e540ba5 |
| First seen | 2026-11-25 |
| Markets | China, India |
Application program: KNX-Mallia Senses command 6 push with thermostat 1.4
| Application number | $0AAF |
|---|---|
| Version | 1.4 |
| Mask version | MV-07B0 (System B) |
| KNX Data Secure | No |
| Minimum ETS version | 5.0 |
| Parameters | 607 |
| Group objects | 251 |
Group objects (251)
| No | Name | Function | Size | DPT | Flags |
|---|---|---|---|---|---|
| 1 | Button 1 | Short/Close, Swtich | 1 Bit | 1.1 switch | CWT |
| 1 | Button 1 | Short, Switch | 1 Bit | 1.1 switch | CWT |
| 1 | Button 1 | Up/Down, Blind | 1 Bit | 1.8 up/down | CT |
| 1 | Button 1 | Short/Close, Value | 1 Bit | 1.1 switch | CT |
| 1 | Button 1 | Short/Close, Value | 4 Bit | 3.7 dimming control | CT |
| 1 | Button 1 | Short/Close, Value | 1 Byte | 5.10 counter pulses (0..255) | CT |
| 1 | Button 1 | Short/Close, Value | 2 Bytes | 7.1 pulses | CT |
| 1 | Button 1 | Short/Close, Scene | 1 Byte | 17.1 scene number | CT |
| 2 | Button 1 | Long/Open, Swtich | 1 Bit | 1.1 switch | CWT |
| 2 | Button 1 | Long, Dimming | 4 Bit | 3.7 dimming control | CWT |
| 2 | Button 1 | Stop/Adjust, Blind | 1 Bit | 1.7 step | CT |
| 2 | Button 1 | Long/Open, Value | 1 Bit | 1.1 switch | CT |
| 2 | Button 1 | Long/Open, Value | 4 Bit | 3.7 dimming control | CT |
| 2 | Button 1 | Long/Open, Value | 1 Byte | 5.10 counter pulses (0..255) | CT |
| 2 | Button 1 | Long/Open, Value | 2 Bytes | 7.1 pulses | CT |
| 2 | Button 1 | Long/Open, Scene | 1 Byte | 17.1 scene number | CT |
| 3 | Button 1 | Disable | 1 Bit | 1.3 enable | CW |
| 4 | Button 2 | Short/Close, Swtich | 1 Bit | 1.1 switch | CWT |
| 4 | Button 2 | Short, Switch | 1 Bit | 1.1 switch | CWT |
| 4 | Button 2 | Up/Down, Blind | 1 Bit | 1.8 up/down | CT |
| 4 | Button 2 | Short/Close, Value | 1 Bit | 1.1 switch | CT |
| 4 | Button 2 | Short/Close, Value | 4 Bit | 3.7 dimming control | CT |
| 4 | Button 2 | Short/Close, Value | 1 Byte | 5.10 counter pulses (0..255) | CT |
| 4 | Button 2 | Short/Close, Value | 2 Bytes | 7.1 pulses | CT |
| 4 | Button 2 | Short/Close, Scene | 1 Byte | 17.1 scene number | CT |
| 5 | Button 2 | Long/Open, Swtich | 1 Bit | 1.1 switch | CWT |
| 5 | Button 2 | Long, Dimming | 4 Bit | 3.7 dimming control | CWT |
| 5 | Button 2 | Stop/Adjust, Blind | 1 Bit | 1.7 step | CT |
| 5 | Button 2 | Long/Open, Value | 1 Bit | 1.1 switch | CT |
| 5 | Button 2 | Long/Open, Value | 4 Bit | 3.7 dimming control | CT |
| 5 | Button 2 | Long/Open, Value | 1 Byte | 5.10 counter pulses (0..255) | CT |
| 5 | Button 2 | Long/Open, Value | 2 Bytes | 7.1 pulses | CT |
| 5 | Button 2 | Long/Open, Scene | 1 Byte | 17.1 scene number | CT |
| 6 | Button 2 | Disable | 1 Bit | 1.3 enable | CW |
| 7 | Button 3 | Short/Close, Swtich | 1 Bit | 1.1 switch | CWT |
| 7 | Button 3 | Short, Switch | 1 Bit | 1.1 switch | CWT |
| 7 | Button 3 | Up/Down, Blind | 1 Bit | 1.8 up/down | CT |
| 7 | Button 3 | Short/Close, Value | 1 Bit | 1.1 switch | CT |
| 7 | Button 3 | Short/Close, Value | 4 Bit | 3.7 dimming control | CT |
| 7 | Button 3 | Short/Close, Value | 1 Byte | 5.10 counter pulses (0..255) | CT |
| 7 | Button 3 | Short/Close, Value | 2 Bytes | 7.1 pulses | CT |
| 7 | Button 3 | Short/Close, Scene | 1 Byte | 17.1 scene number | CT |
| 8 | Button 3 | Long/Open, Swtich | 1 Bit | 1.1 switch | CWT |
| 8 | Button 3 | Long, Dimming | 4 Bit | 3.7 dimming control | CWT |
| 8 | Button 3 | Stop/Adjust, Blind | 1 Bit | 1.7 step | CT |
| 8 | Button 3 | Long/Open, Value | 1 Bit | 1.1 switch | CT |
| 8 | Button 3 | Long/Open, Value | 4 Bit | 3.7 dimming control | CT |
| 8 | Button 3 | Long/Open, Value | 1 Byte | 5.10 counter pulses (0..255) | CT |
| 8 | Button 3 | Long/Open, Value | 2 Bytes | 7.1 pulses | CT |
| 8 | Button 3 | Long/Open, Scene | 1 Byte | 17.1 scene number | CT |
| 9 | Button 3 | Disable | 1 Bit | 1.3 enable | CW |
| 10 | Button 4 | Short/Close, Swtich | 1 Bit | 1.1 switch | CWT |
| 10 | Button 4 | Short, Switch | 1 Bit | 1.1 switch | CWT |
| 10 | Button 4 | Up/Down, Blind | 1 Bit | 1.8 up/down | CT |
| 10 | Button 4 | Short/Close, Value | 1 Bit | 1.1 switch | CT |
| 10 | Button 4 | Short/Close, Value | 4 Bit | 3.7 dimming control | CT |
| 10 | Button 4 | Short/Close, Value | 1 Byte | 5.10 counter pulses (0..255) | CT |
| 10 | Button 4 | Short/Close, Value | 2 Bytes | 7.1 pulses | CT |
| 10 | Button 4 | Short/Close, Scene | 1 Byte | 17.1 scene number | CT |
| 11 | Button 4 | Long/Open, Swtich | 1 Bit | 1.1 switch | CWT |
| 11 | Button 4 | Long, Dimming | 4 Bit | 3.7 dimming control | CWT |
| 11 | Button 4 | Stop/Adjust, Blind | 1 Bit | 1.7 step | CT |
| 11 | Button 4 | Long/Open, Value | 1 Bit | 1.1 switch | CT |
| 11 | Button 4 | Long/Open, Value | 4 Bit | 3.7 dimming control | CT |
| 11 | Button 4 | Long/Open, Value | 1 Byte | 5.10 counter pulses (0..255) | CT |
| 11 | Button 4 | Long/Open, Value | 2 Bytes | 7.1 pulses | CT |
| 11 | Button 4 | Long/Open, Scene | 1 Byte | 17.1 scene number | CT |
| 12 | Button 4 | Disable | 1 Bit | 1.3 enable | CW |
| 13 | Button 5 | Short/Close, Swtich | 1 Bit | 1.1 switch | CWT |
| 13 | Button 5 | Short, Switch | 1 Bit | 1.1 switch | CWT |
| 13 | Button 5 | Up/Down, Blind | 1 Bit | 1.8 up/down | CT |
| 13 | Button 5 | Short/Close, Value | 1 Bit | 1.1 switch | CT |
| 13 | Button 5 | Short/Close, Value | 4 Bit | 3.7 dimming control | CT |
| 13 | Button 5 | Short/Close, Value | 1 Byte | 5.10 counter pulses (0..255) | CT |
| 13 | Button 5 | Short/Close, Value | 2 Bytes | 7.1 pulses | CT |
| 13 | Button 5 | Short/Close, Scene | 1 Byte | 17.1 scene number | CT |
| 14 | Button 5 | Long/Open, Swtich | 1 Bit | 1.1 switch | CWT |
| 14 | Button 5 | Long, Dimming | 4 Bit | 3.7 dimming control | CWT |
| 14 | Button 5 | Stop/Adjust, Blind | 1 Bit | 1.7 step | CT |
| 14 | Button 5 | Long/Open, Value | 1 Bit | 1.1 switch | CT |
| 14 | Button 5 | Long/Open, Value | 4 Bit | 3.7 dimming control | CT |
| 14 | Button 5 | Long/Open, Value | 1 Byte | 5.10 counter pulses (0..255) | CT |
| 14 | Button 5 | Long/Open, Value | 2 Bytes | 7.1 pulses | CT |
| 14 | Button 5 | Long/Open, Scene | 1 Byte | 17.1 scene number | CT |
| 15 | Button 5 | Disable | 1 Bit | 1.3 enable | CW |
| 16 | Button 6 | Short/Close, Swtich | 1 Bit | 1.1 switch | CWT |
| 16 | Button 6 | Short, Switch | 1 Bit | 1.1 switch | CWT |
| 16 | Button 6 | Up/Down, Blind | 1 Bit | 1.8 up/down | CT |
| 16 | Button 6 | Short/Close, Value | 1 Bit | 1.1 switch | CT |
| 16 | Button 6 | Short/Close, Value | 4 Bit | 3.7 dimming control | CT |
| 16 | Button 6 | Short/Close, Value | 1 Byte | 5.10 counter pulses (0..255) | CT |
| 16 | Button 6 | Short/Close, Value | 2 Bytes | 7.1 pulses | CT |
| 16 | Button 6 | Short/Close, Scene | 1 Byte | 17.1 scene number | CT |
| 17 | Button 6 | Long/Open, Swtich | 1 Bit | 1.1 switch | CWT |
| 17 | Button 6 | Long, Dimming | 4 Bit | 3.7 dimming control | CWT |
| 17 | Button 6 | Stop/Adjust, Blind | 1 Bit | 1.7 step | CT |
| 17 | Button 6 | Long/Open, Value | 1 Bit | 1.1 switch | CT |
| 17 | Button 6 | Long/Open, Value | 4 Bit | 3.7 dimming control | CT |
| 17 | Button 6 | Long/Open, Value | 1 Byte | 5.10 counter pulses (0..255) | CT |
| 17 | Button 6 | Long/Open, Value | 2 Bytes | 7.1 pulses | CT |
| 17 | Button 6 | Long/Open, Scene | 1 Byte | 17.1 scene number | CT |
| 18 | Button 6 | Disable | 1 Bit | 1.3 enable | CW |
| 19 | Button 7 | Short/Close, Swtich | 1 Bit | 1.1 switch | CWT |
| 19 | Button 7 | Short, Switch | 1 Bit | 1.1 switch | CWT |
| 19 | Button 7 | Up/Down, Blind | 1 Bit | 1.8 up/down | CT |
| 19 | Button 7 | Short/Close, Value | 1 Bit | 1.1 switch | CT |
| 19 | Button 7 | Short/Close, Value | 4 Bit | 3.7 dimming control | CT |
| 19 | Button 7 | Short/Close, Value | 1 Byte | 5.10 counter pulses (0..255) | CT |
| 19 | Button 7 | Short/Close, Value | 2 Bytes | 7.1 pulses | CT |
| 19 | Button 7 | Short/Close, Scene | 1 Byte | 17.1 scene number | CT |
| 20 | Button 7 | Long/Open, Swtich | 1 Bit | 1.1 switch | CWT |
| 20 | Button 7 | Long, Dimming | 4 Bit | 3.7 dimming control | CWT |
| 20 | Button 7 | Stop/Adjust, Blind | 1 Bit | 1.7 step | CT |
| 20 | Button 7 | Long/Open, Value | 1 Bit | 1.1 switch | CT |
| 20 | Button 7 | Long/Open, Value | 4 Bit | 3.7 dimming control | CT |
| 20 | Button 7 | Long/Open, Value | 1 Byte | 5.10 counter pulses (0..255) | CT |
| 20 | Button 7 | Long/Open, Value | 2 Bytes | 7.1 pulses | CT |
| 20 | Button 7 | Long/Open, Scene | 1 Byte | 17.1 scene number | CT |
| 21 | Button 7 | Disable | 1 Bit | 1.3 enable | CW |
| 22 | Button 8 | Short/Close, Swtich | 1 Bit | 1.1 switch | CWT |
| 22 | Button 8 | Short, Switch | 1 Bit | 1.1 switch | CWT |
| 22 | Button 8 | Up/Down, Blind | 1 Bit | 1.8 up/down | CT |
| 22 | Button 8 | Short/Close, Value | 1 Bit | 1.1 switch | CT |
| 22 | Button 8 | Short/Close, Value | 4 Bit | 3.7 dimming control | CT |
| 22 | Button 8 | Short/Close, Value | 1 Byte | 5.10 counter pulses (0..255) | CT |
| 22 | Button 8 | Short/Close, Value | 2 Bytes | 7.1 pulses | CT |
| 22 | Button 8 | Short/Close, Scene | 1 Byte | 17.1 scene number | CT |
| 23 | Button 8 | Long/Open, Swtich | 1 Bit | 1.1 switch | CWT |
| 23 | Button 8 | Long, Dimming | 4 Bit | 3.7 dimming control | CWT |
| 23 | Button 8 | Stop/Adjust, Blind | 1 Bit | 1.7 step | CT |
| 23 | Button 8 | Long/Open, Value | 1 Bit | 1.1 switch | CT |
| 23 | Button 8 | Long/Open, Value | 4 Bit | 3.7 dimming control | CT |
| 23 | Button 8 | Long/Open, Value | 1 Byte | 5.10 counter pulses (0..255) | CT |
| 23 | Button 8 | Long/Open, Value | 2 Bytes | 7.1 pulses | CT |
| 23 | Button 8 | Long/Open, Scene | 1 Byte | 17.1 scene number | CT |
| 24 | Button 8 | Disable | 1 Bit | 1.3 enable | CW |
| 25 | LED 1 | Status | 1 Bit | 1.1 switch | CWTU |
| 25 | LED 1 | Status | 1 Byte | 5.10 counter pulses (0..255) | CWTU |
| 26 | LED 2 | Status | 1 Bit | 1.1 switch | CWTU |
| 26 | LED 2 | Status | 1 Byte | 5.10 counter pulses (0..255) | CWTU |
| 27 | LED 3 | Status | 1 Bit | 1.1 switch | CWTU |
| 27 | LED 3 | Status | 1 Byte | 5.10 counter pulses (0..255) | CWTU |
| 28 | LED 4 | Status | 1 Bit | 1.1 switch | CWTU |
| 28 | LED 4 | Status | 1 Byte | 5.10 counter pulses (0..255) | CWTU |
| 29 | LED 5 | Status | 1 Bit | 1.1 switch | CWTU |
| 29 | LED 5 | Status | 1 Byte | 5.10 counter pulses (0..255) | CWTU |
| 30 | LED 6 | Status | 1 Bit | 1.1 switch | CWTU |
| 30 | LED 6 | Status | 1 Byte | 5.10 counter pulses (0..255) | CWTU |
| 31 | LED 7 | Status | 1 Bit | 1.1 switch | CWTU |
| 31 | LED 7 | Status | 1 Byte | 5.10 counter pulses (0..255) | CWTU |
| 32 | LED 8 | Status | 1 Bit | 1.1 switch | CWTU |
| 32 | LED 8 | Status | 1 Byte | 5.10 counter pulses (0..255) | CWTU |
| 33 | Proximity function | Dis/En Proximity function | 1 Bit | 1.3 enable | CW |
| 34 | Proximity function | Proximity input | 1 Bit | 1.1 switch | CW |
| 35 | Proximity function | Proximity output | 1 Bit | 1.1 switch | CT |
| 35 | Proximity function | Proximity output | 1 Byte | 17.1 scene number | CT |
| 36 | General | Day/Night | 1 Bit | 1.24 day/night | CW |
| 37 | General | Screen locking | 1 Bit | 1.3 enable | CW |
| 38 | Internal sensor | Temperature value | 2 Bytes | 9.1 temperature (°C) | CRT |
| 39 | AC | External temperature, In | 2 Bytes | 9.1 temperature (°C) | CWTU |
| 40 | AC | ON/OFF, Out | 1 Bit | 1.1 switch | CT |
| 41 | AC | ON/OFF Status, In | 1 Bit | 1.1 switch | CWU |
| 42 | AC | Preset 1Bit, In | 1 Bit | 1.22 scene | CW |
| 43 | AC | Mode, Out | 1 Byte | 20.105 HVAC control mode | CT |
| 44 | AC | Mode status, In | 1 Byte | 20.105 HVAC control mode | CWU |
| 45 | AC | Fan speed, Out | 1 Byte | 5.1 percentage (0..100%) | CT |
| 45 | AC | Fan speed, Out | 1 Byte | 5.100 fan stage (0..255) | CT |
| 46 | AC | Fan speed status, In | 1 Byte | 5.1 percentage (0..100%) | CWU |
| 46 | AC | Fan speed status, In | 1 Byte | 5.100 fan stage (0..255) | CWU |
| 47 | AC | Setpoint temperature, Out | 2 Bytes | 9.1 temperature (°C) | CT |
| 48 | AC | Setpoint temperature, In | 2 Bytes | 9.1 temperature (°C) | CWU |
| 49 | AC | Vanes swing (1-swing,0-stop), Out | 1 Bit | 1.10 start/stop | CT |
| 50 | AC | Vanes swing (1-swing,0-stop), In | 1 Bit | 1.10 start/stop | CWU |
| 51 | AC | Vanes position 1..4, Out | 1 Byte | 5.10 counter pulses (0..255) | CT |
| 52 | AC | Vanes position 1..4 status, In | 1 Byte | 5.10 counter pulses (0..255) | CWU |
| 53 | AC | Scene, In | 1 Byte | 17.1 scene number | CW |
| 54 | Ventilation | External temperature, In | 2 Bytes | 9.1 temperature (°C) | CWTU |
| 55 | Ventilation | ON/OFF, Out | 1 Bit | 1.1 switch | CT |
| 56 | Ventilation | ON/OFF Status, In | 1 Bit | 1.1 switch | CW |
| 57 | Ventilation | Fan speed No.1 1Bit, Out | 1 Bit | 1.1 switch | CT |
| 58 | Ventilation | Fan speed No.2 1Bit, Out | 1 Bit | 1.1 switch | CT |
| 59 | Ventilation | Fan speed No.3 1Bit, Out | 1 Bit | 1.1 switch | CT |
| 60 | Ventilation | Fan speed, Out | 1 Byte | 5.1 percentage (0..100%) | CT |
| 60 | Ventilation | Fan speed, Out | 1 Byte | 5.100 fan stage (0..255) | CT |
| 61 | Ventilation | Fan speed status, In | 1 Byte | 5.1 percentage (0..100%) | CW |
| 61 | Ventilation | Fan speed status, In | 1 Byte | 5.100 fan stage (0..255) | CW |
| 62 | Ventilation | Preset 1Bit, In | 1 Bit | 1.22 scene | CW |
| 65 | Ventilation | Filter alarm, Out | 1 Bit | 1.5 alarm | CT |
| 66 | Ventilation | Filter timer counter change, In | 2 Bytes | 7.7 time (h) | CW |
| 67 | Ventilation | Filter timer reset, Out | 1 Bit | 1.15 reset | CT |
| 68 | Ventilation | Scene, In | 1 Byte | 17.1 scene number | CW |
| 69 | Floor Heating | External temperature, In | 2 Bytes | 9.1 temperature (°C) | CWTU |
| 70 | Floor Heating | ON/OFF, Out | 1 Bit | 1.1 switch | CRT |
| 70 | Floor Heating | ON/OFF, Out | 1 Bit | 1.1 switch | CT |
| 71 | Floor Heating | ON/OFF status, In | 1 Bit | 1.1 switch | CWU |
| 71 | Floor Heating | ON/OFF status, In | 1 Bit | 1.1 switch | CWTU |
| 72 | Floor Heating | Preset 1Bit, In | 1 Bit | 1.22 scene | CW |
| 73 | Floor Heating | Setpoint temperature, Out | 2 Bytes | 9.1 temperature (°C) | CRT |
| 73 | Floor Heating | Setpoint temperature, Out | 2 Bytes | 9.1 temperature (°C) | CT |
| 74 | Floor Heating | Setpoint temperature, In | 2 Bytes | 9.1 temperature (°C) | CWU |
| 74 | Floor Heating | Setpoint temperature, In | 2 Bytes | 9.1 temperature (°C) | CWTU |
| 75 | Floor Heating | Scene, In | 1 Byte | 17.1 scene number | CW |
| 76 | Floor Heating | Heating ON/OFF, Out | 1 Bit | 1.1 switch | CRT |
| 76 | Floor Heating | Heating ON/OFF, In | 1 Bit | 1.1 switch | CWTU |
| 78 | FCU | ON/OFF status, In | 1 Bit | 1.1 switch | CWU |
| 78 | FCU | ON/OFF status, In | 1 Bit | 1.1 switch | CWTU |
| 79 | FCU | External temperature, In | 2 Bytes | 9.1 temperature (°C) | CWTU |
| 80 | FCU | Current temperature setpoint, In | 2 Bytes | 9.1 temperature (°C) | CWU |
| 80 | FCU | Current temperature setpoint, In | 2 Bytes | 9.1 temperature (°C) | CWTU |
| 80 | FCU | Base temperature setpoint, In | 2 Bytes | 9.1 temperature (°C) | CWU |
| 81 | FCU | Heating/Cooling mode, In | 1 Bit | 1.100 cooling/heating | CWU |
| 81 | FCU | Heating/Cooling mode, In | 1 Bit | 1.100 cooling/heating | CWTU |
| 82 | FCU | Operation mode, In | 1 Byte | 20.102 HVAC mode | CWTU |
| 82 | FCU | Operation mode, In | 1 Byte | 20.102 HVAC mode | CWU |
| 83 | FCU | Fan speed, In | 1 Byte | 5.1 percentage (0..100%) | CWTU |
| 83 | FCU | Fan speed, In | 1 Byte | 5.100 fan stage (0..255) | CWTU |
| 84 | FCU | Fan automatic operation, In | 1 Bit | 1.3 enable | CWTU |
| 85 | FCU | Extended comfort mode, In | 1 Bit | 1.16 acknowledge | CW |
| 86 | FCU | Window contact, In | 1 Bit | 1.19 window/door | CWTU |
| 87 | FCU | Presence detector, In | 1 Bit | 1.18 occupancy | CWTU |
| 89 | FCU | Scene, In | 1 Byte | 18.1 scene control | CW |
| 90 | FCU | ON/OFF, Out | 1 Bit | 1.1 switch | CRT |
| 90 | FCU | ON/OFF, Out | 1 Bit | 1.1 switch | CT |
| 92 | FCU | Current base setpoint temperature, Out | 2 Bytes | 9.1 temperature (°C) | CT |
| 93 | FCU | Current setpoint adjustment, Out | 2 Bytes | 9.1 temperature (°C) | CRT |
| 93 | FCU | Current setpoint adjustment, Out | 2 Bytes | 9.1 temperature (°C) | CT |
| 94 | FCU | Heating/Cooling mode, Out | 1 Bit | 1.100 cooling/heating | CRT |
| 95 | FCU | Operation mode, Out | 1 Byte | 20.102 HVAC mode | CRT |
| 95 | FCU | Operation mode, Out | 1 Byte | 20.102 HVAC mode | CT |
| 96 | FCU | Heating control value, Out | 1 Bit | 1.1 switch | CRT |
| 96 | FCU | Heating control value, Out | 1 Byte | 5.1 percentage (0..100%) | CRT |
| 96 | FCU | Heating/cooling control value, Out | 1 Bit | 1.1 switch | CRT |
| 96 | FCU | Heating/cooling control value, Out | 1 Byte | 5.1 percentage (0..100%) | CRT |
| 97 | FCU | Cooling control value, Out | 1 Bit | 1.1 switch | CRT |
| 97 | FCU | Cooling control value, Out | 1 Byte | 5.1 percentage (0..100%) | CRT |
| 98 | FCU | Fan speed, Out | 1 Byte | 5.1 percentage (0..100%) | CRT |
| 98 | FCU | Fan speed, Out | 1 Byte | 5.1 percentage (0..100%) | CT |
| 98 | FCU | Fan speed, Out | 1 Byte | 5.100 fan stage (0..255) | CRT |
| 98 | FCU | Fan speed, Out | 1 Byte | 5.100 fan stage (0..255) | CT |
| 99 | FCU | Fan Automatic operation, Out | 1 Bit | 1.3 enable | CRT |
| 99 | FCU | Fan Automatic operation, Out | 1 Bit | 1.3 enable | CT |
| 100 | AC | Auto mode, Out | 1 Bit | 1.3 enable | CT |
| 101 | AC | Heat mode, Out | 1 Bit | 1.3 enable | CT |
| 102 | AC | Cool mode, Out | 1 Bit | 1.3 enable | CT |
| 103 | AC | Fan mode, Out | 1 Bit | 1.3 enable | CT |
| 104 | AC | Dry mode, Out | 1 Bit | 1.3 enable | CT |
| 105 | AC | Auto mode status, In | 1 Bit | 1.3 enable | CWU |
| 106 | AC | Heat mode status, In | 1 Bit | 1.3 enable | CWU |
| 107 | AC | Cool mode status, In | 1 Bit | 1.3 enable | CWU |
| 108 | AC | Fan mode status, In | 1 Bit | 1.3 enable | CWU |
| 109 | AC | Dry mode status, In | 1 Bit | 1.3 enable | CWU |
Parameters (260)
| Parameter | Type | Default |
|---|---|---|
| Normal day backlight [10..100] | unsignedInt 10…100 | 10 |
| Normal night backlight [10..100] | unsignedInt 10…100 | 50 |
| Standby backlight [0..10] | unsignedInt 0…10 | 10 |
| Normal to standby delay time [1..255] | unsignedInt 1…255 | 5 |
| Buzzer volume level [0..5, 0=inactive] | list | 0 |
| Touch button vibration feedback | unsignedInt 0…1 | 0 |
| Long operation for touch after | list | 1.0 |
| The Proximity function triggered via | list | Sensor |
| Object type of output value | list | 1bit[On/Off] |
| Output value | list | ON |
| Output value | list | Scene NO.1 |
| Delay time for sending [0..65535]s | unsignedInt 0…65535 | 0 |
| Hardware type | list | 8 buttons |
| Delay time for no operation [0..255, 0=inactive] | unsignedInt 0…255 | 5 |
| LED status object read request after restart | unsignedInt 0…1 | 0 |
| Initial LED status | list | No |
| Function of button | list | Disable |
| Distinction between short and long operation | list | No |
| Long operation after [3..25] | unsignedInt 3…25 | 3 |
| Reaction on short operation or closing the contact | list | TOGGLE |
| Reaction on long operation or opening the contact | list | No reaction |
| Reaction on short operation | list | TOGGLE |
| Reaction on long operation | list | Brighter/Darker |
| Dimming mode | list | Start-Stop dimming |
| Step size | list | 1/8 |
| Interval of tele. cyclic send [0..25,0=send once] | unsignedInt 0…25 | 0 |
| Reaction on short operation | list | Up/Down |
| Reaction on long operation | list | Stop(Adjust Up/Down) |
| Reaction on short operation or closing the contact | list | 1bit value[0..1] |
| Output value [0..1] | list | OFF |
| Output value [0..15] | unsignedInt 0…15 | 0 |
| Output value [0..255] | unsignedInt 0…255 | 0 |
| Output value [0..65535] | unsignedInt 0…65535 | 0 |
| Reaction on short operation or closing the contact | list | Recall scene |
| 8 bit scene number | list | Scene NO.1 |
| Reaction on long operation or opening the contact | list | Store scene |
| Disable function | list | Disable |
| Trigger value of disable object | list | Disable=0/Enable=1 |
| LED 1 function | list | Disable |
| External object datatype | list | 1Bit |
| When object value is "0",LED is | list | OFF |
| When object value is "1",LED is | list | Warm white |
| Threshold value is | unsignedInt 1…255 | 50 |
| If object value<threshold value,LED is | list | OFF |
| If object value=threshold value,LED is | list | Warm white |
| If object value>threshold value,LED is | list | OFF |
| Ventilation function | unsignedInt 0…1 | 0 |
| Floor heating function | unsignedInt 0…1 | 0 |
| Room temperature reference from | list | Internal sensor |
| Time period for request external sensor [0...255] | unsignedInt 0…255 | 10 |
| Object type of AC ON/OFF | list | 1Bit |
| Output value for AC ON | unsignedInt 0…255 | 1 |
| Status value for AC ON | unsignedInt 0…255 | 1 |
| Output value for AC OFF | unsignedInt 0…255 | 0 |
| Status value for AC OFF | unsignedInt 0…255 | 0 |
| When voltage recovery, AC status is | list | Last Status |
| ON/OFF status | list | ON |
| Mode | list | Cool |
| Fan speed | list | High |
| Temperature setpoint [16..30] | unsignedInt 16…30 | 26 |
| AC Setting for Preset value='0' | list | OFF |
| AC Setting for Preset value='1' | list | ON |
| Min. setpoint temperature [16..30] | unsignedInt 16…30 | 16 |
| Max. setpoint temperature [16..30] | unsignedInt 16…30 | 30 |
| Vanes swing | unsignedInt 0…1 | 0 |
| Timer | unsignedInt 0…1 | 0 |
| Scene | unsignedInt 0…1 | 0 |
| Object datatype of 1byte fan speed | list | Percentage (DPT_5.001) |
| Output value for fan speed auto | unsignedInt 0…100 | 0 |
| Output value for fan speed low | unsignedInt 0…100 | 33 |
| Output value for fan speed medium | unsignedInt 0…100 | 67 |
| Output value for fan speed high | unsignedInt 0…100 | 100 |
| Output value for fan speed auto | unsignedInt 0…255 | 0 |
| Output value for fan speed low | unsignedInt 0…255 | 1 |
| Output value for fan speed medium | unsignedInt 0…255 | 2 |
| Output value for fan speed high | unsignedInt 0…255 | 3 |
| Status value for fan speed auto | unsignedInt 0…100 | 0 |
| Status value for fan speed low | unsignedInt 0…100 | 33 |
| Status value for fan speed medium | unsignedInt 0…100 | 67 |
| Status value for fan speed high | unsignedInt 0…100 | 100 |
| Status value for fan speed auto | unsignedInt 0…255 | 0 |
| Status value for fan speed low | unsignedInt 0…255 | 1 |
| Status value for fan speed medium | unsignedInt 0…255 | 2 |
| Status value for fan speed high | unsignedInt 0…255 | 3 |
| Auto mode | unsignedInt 0…1 | 1 |
| Output value for Auto [0..255] | unsignedInt 0…255 | 0 |
| Status value for Auto [0..255] | unsignedInt 0…255 | 0 |
| Heat mode | unsignedInt 0…1 | 1 |
| Output value for Heat [0..255] | unsignedInt 0…255 | 1 |
| Status value for Heat [0..255] | unsignedInt 0…255 | 1 |
| Cool mode | unsignedInt 0…1 | 1 |
| Output value for Cool [0..255] | unsignedInt 0…255 | 3 |
| Status value for Cool [0..255] | unsignedInt 0…255 | 3 |
| Fan mode | unsignedInt 0…1 | 1 |
| Output value for Fan [0..255] | unsignedInt 0…255 | 9 |
| Status value for fan [0..255] | unsignedInt 0…255 | 9 |
| Dehumidification mode | unsignedInt 0…1 | 1 |
| Output value for Dehumidification [0..255] | unsignedInt 0…255 | 14 |
| Status value for Dehumidification [0..255] | unsignedInt 0…255 | 14 |
| 1->Assign scene NO.[1..64,0=inactive] | unsignedInt 0…64 | 0 |
| 2->Assign scene NO.[1..64,0=inactive] | unsignedInt 0…64 | 0 |
| 3->Assign scene NO.[1..64,0=inactive] | unsignedInt 0…64 | 0 |
| 4->Assign scene NO.[1..64,0=inactive] | unsignedInt 0…64 | 0 |
| Command value for position 1 | unsignedInt 0…255 | 1 |
| Command value for position 2 | unsignedInt 0…255 | 2 |
| Command value for position 3 | unsignedInt 0…255 | 3 |
| Command value for position 4 | unsignedInt 0…255 | 4 |
| Status value for position 1 | unsignedInt 0…255 | 1 |
| Status value for position 2 | unsignedInt 0…255 | 2 |
| Status value for position 3 | unsignedInt 0…255 | 3 |
| Status value for position 4 | unsignedInt 0…255 | 4 |
| When voltage recovery, Ventilation status is | list | Last Status |
| 1Bit Preset Speed for value='0' | list | OFF |
| 1Bit Preset Speed for value='1' | list | Medium |
| Mode | unsignedInt 0…1 | 0 |
| Filter timer counter | unsignedInt 0…1 | 0 |
| Evaluation time [100..10000] | unsignedInt 100…10000 | 1000 |
| Object value for fan speed off | list | No.1=0, No.2=0, No.3=0 |
| Object value for fan speed low | list | No.1=1, No.2=0, No.3=0 |
| Object value for fan speed medium | list | No.1=1, No.2=1, No.3=0 |
| Object value for fan speed high | list | No.1=1, No.2=1, No.3=1 |
| Output value for fan speed off | unsignedInt 0…100 | 0 |
| Output value for fan speed off | unsignedInt 0…255 | 0 |
| Status value for fan speed off | unsignedInt 0…100 | 0 |
| Status value for fan speed high | unsignedInt 0…100 | 100 |
| Status value for fan speed off | unsignedInt 0…255 | 0 |
| Output value for internal circulation | unsignedInt 0…255 | 1 |
| Output value for air supply | unsignedInt 0…255 | 2 |
| Output value for ventilation | unsignedInt 0…255 | 3 |
| Status value for internal circulation | unsignedInt 0…255 | 1 |
| Status value for air supply | unsignedInt 0…255 | 2 |
| Status value for ventilation | unsignedInt 0…255 | 3 |
| Fan Status | list | OFF |
| Fan Status | list | Low |
| Fan Status | list | Medium |
| Fan Status | list | High |
| When voltage recovery, Floor heating status is | list | Last status |
| Temperature setpoint [10..30] | unsignedInt 10…30 | 26 |
| 1Bit Preset Speed for value='0' | list | ON |
| 1Bit Preset Speed for value='1' | list | ON |
| Temperature setpoint after download | unsignedInt 10…30 | 26 |
| Output value for Floor heating ON | unsignedInt 0…255 | 1 |
| Status value for Floor heating ON | unsignedInt 0…255 | 1 |
| Output value for Floor heating OFF | unsignedInt 0…255 | 0 |
| Status value for Floor heating OFF | unsignedInt 0…255 | 0 |
| Min. setpoint temperature [10..30] | unsignedInt 10…30 | 10 |
| Max. setpoint temperature [10..30] | unsignedInt 10…30 | 30 |
| Temperature calibration | list | 0.0 |
| Send temperature when the result change by [0..10] | list | 1.0 |
| Cyclically send temperature [0..255,0=inactive] | unsignedInt 0…255 | 10 |
| Mode | list | Ventilation |
| Object type of Floor heating ON/OFF | list | 1Bit |
| Temperature control method | list | 2 point control |
| Lower Hysteresis[0...200] | unsignedInt 0…200 | 10 |
| Upper Hysteresis[0...200] | unsignedInt 0…200 | 10 |
| LED 2 function | list | Disable |
| LED 3 function | list | Disable |
| LED 4 function | list | Disable |
| LED 5 function | list | Disable |
| LED 6 function | list | Disable |
| LED 7 function | list | Disable |
| LED 8 function | list | Disable |
| Brightness of cool white LED | list | 100 |
| Brightness of warm white LED | list | 100 |
| Room temperature control function as | list | Disable |
| Setpoint Temperature error | unsignedInt 0…1 | 0 |
| Work mode | list | Master |
| Period for request external sensor [0..255] | unsignedInt 0…255 | 5 |
| Interface display temperature | list | Actual temperature |
| Setpoint temperature adjustment step | list | 0.5K |
| Min. setpoint temperature [5..37] | list | 5 |
| Max. setpoint temperature [5..37] | list | 37 |
| Power on/off status after download | list | ON |
| Power on/off status after voltage recovery | list | As before voltage failure |
| Temperature | list | 10 |
| Room temperature control mode | list | Cooling |
| Room temperature operation mode | unsignedInt 0…1 | 1 |
| Initial setpoint temperature | list | 20.0 |
| Controller status after download | list | Standby mode |
| Controller status after voltage recovery | list | As before voltage failure |
| Extended comfort mode [0..255,0=inactive] | unsignedInt 0…255 | 0 |
| Setpoint method for operating mode | list | Absolute |
| Base setpoint temperature | list | 20.0 |
| Reduced heating in standby mode [0..10] | list | 2 |
| Reduced heating in economy mode [0..10] | list | 4 |
| Setpoint temperature in frost protection [5..10] | list | 7 |
| Setpoint temperature in comfort mode [5..37] | list | 21 |
| Setpoint temperature in standby mode [5..37] | list | 19 |
| Setpoint temperature in economy mode [5..37] | list | 17 |
| Type of heating control | list | Switching on/off(use 2-point control) |
| Invert control value | unsignedInt 0…1 | 0 |
| Lower Hysteresis [0..200] | unsignedInt 0…200 | 10 |
| Upper Hysteresis [0..200] | unsignedInt 0…200 | 10 |
| PWM cycle time [1..255] | unsignedInt 1…255 | 15 |
| Heating speed | list | Hot water heating(5K/150min) |
| Proportional range [10..100] | unsignedInt 10…100 | 40 |
| Reset time [0..255] | unsignedInt 0…255 | 150 |
| Send control value on change by [0..100,0=inactive] | unsignedInt 0…100 | 4 |
| Cyclically send control value[0..255] | unsignedInt 0…255 | 0 |
| Increased cooling in standby mode [0..10] | list | 2 |
| Increased cooling in economy mode[0..10] | list | 4 |
| Setpoint temperature in heat protection[30..37] | list | 35 |
| Setpoint temperature in comfort mode [5..37] | list | 23 |
| Setpoint temperature in standby mode [5..37] | list | 25 |
| Setpoint temperature in economy mode[5..37] | list | 27 |
| Setpoint temperature in heat protection [30..37] | list | 35 |
| Type of cooling control | list | Switching on/off(use 2-point control) |
| Cooling speed | list | Cooling ceiling(5K/240min) |
| Heating/Cooling switchover | list | Via both button and object |
| Heating/Cooling switchover | list | Automatic changeover |
| Heating/Cooling status after download | list | Cooling |
| Heating/Cooling status after voltage recovery | list | As before voltage failure |
| Room temperature control system | list | 4 pipes system |
| Upper dead zone | list | 2.0 |
| Lower dead zone | list | 2.0 |
| Minimum zone between heating and cooling setpoint | list | 2.0 |
| Type of heating/cooling control | list | Switching on/off(use 2-point control) |
| Window contact input function | unsignedInt 0…1 | 0 |
| Delay for window contact [0..65535] | unsignedInt 0…65535 | 15 |
| Operation mode for open window | list | Frost/heat protection |
| Bus presence detector function | unsignedInt 0…1 | 0 |
| Fan | unsignedInt 0…1 | 0 |
| Output value for Fan speed low | unsignedInt 1…100 | 33 |
| Output value for Fan speed medium | unsignedInt 1…100 | 67 |
| Output value for Fan speed high | unsignedInt 1…100 | 100 |
| Status value for Fan speed low | unsignedInt 1…100 | 33 |
| Status value for Fan speed medium | unsignedInt 1…100 | 67 |
| Status value for Fan speed high | unsignedInt 1…100 | 100 |
| Output value for Fan speed low | unsignedInt 1…255 | 1 |
| Output value for Fan speed medium | unsignedInt 1…255 | 2 |
| Output value for Fan speed high | unsignedInt 1…255 | 3 |
| Status value for Fan speed low | unsignedInt 1…255 | 1 |
| Status value for Fan speed medium | unsignedInt 1…255 | 2 |
| Status value for Fan speed high | unsignedInt 1…255 | 3 |
| Automatic operation function | list | Disable |
| Threshold value speed OFF<->low [0..255] | unsignedInt 0…255 | 80 |
| Threshold value speed low<->medium [1..255] | unsignedInt 1…255 | 150 |
| Threshold value speed medium<->high [1..255] | unsignedInt 1…255 | 200 |
| Hysteresis threshold value in +/-[0..50] | unsignedInt 0…50 | 10 |
| Temperature difference speed OFF<->low [0..200] | unsignedInt 0…200 | 20 |
| Temperature difference speed low<->medium [1..200] | unsignedInt 1…200 | 30 |
| Temperature difference speed medium<->high [1..200] | unsignedInt 1…200 | 40 |
| Hysteresis temperature difference in [0..50] | unsignedInt 0…50 | 10 |
| Minimum time in fan speed [0..65535] | unsignedInt 0…65535 | 60 |
| ON/OFF status | list | Unchange |
| Temperature | list | Unchange |
| Operation mode | list | Unchange |
| 5->Assign scene NO.[1..64,0=inactive] | unsignedInt 0…64 | 0 |
| Control value after temp. error [0..100] (if 2-point control, set value '0'=0, set value '>0'=1) | unsignedInt 0…100 | 0 |
| Low temperature protection when power off | unsignedInt 0…1 | 1 |
| Fan speed auto function | unsignedInt 0…1 | 0 |
| Object type of mode | list | 1Byte |
| Output/Status value for Auto | list | 1 |
| Output/Status value for Heat | list | 1 |
| Output/Status value for Cool | list | 0 |
| Output/Status value for Fan | list | 1 |
| Output/Status value for Dehumidification | list | 1 |
| Low temperature protection when power off | list | Frost protection mode |
| Cyclically send value [0...255] (on/off, fan speed, setpoint temperature, mode) | unsignedInt 0…255 | 10 |
| Cyclically send heating on/off value [0...255] | unsignedInt 0…255 | 10 |
Version history
| Application | App no | Fingerprint | First seen | Size | File |
|---|---|---|---|---|---|
| KNX-Mallia Senses command 6 push with thermostat 1.4 latest | $0AAF | B470 | 2026-11-25 | 168 KB | Download |
| KNX-Mallia Senses command 6 push with thermostat 1.2 | $0AAF | C104 | 2026-11-25 | 167 KB | Download |
About this file
This is the official ETS product database for the LEGRAND Appareillage électrique KNX-Mallia Senses command 6 push with thermostat brushed black (281028BB/F0306TKNX), published by the manufacturer in the KNX online catalog. To use it, open ETS, go to Catalogs → Import and choose the downloaded .knxprod file. The device then appears in your catalog and can be added to a project. Older versions are kept so existing projects can be matched to the application program they were commissioned with.
More from LEGRAND Appareillage électrique
- KNX-Mallia Senses command 4 push brushed black 281024BB/F0204KNX
- KNX-Mallia Senses command 4 push silver 281024DS/F0204KNX
- KNX-Mallia Senses command 4 push white 281024MW/F0204KNX
- KNX-Mallia Senses command 6 push brushed black 281025BB/F0306KNX
- KNX-Mallia Senses command 6 push silver 281025DS/F0306KNX
- KNX-Mallia Senses command 6 push white 281025MW/F0306KNX
- KNX-Mallia Senses command 8 push brushed black 281026BB/F0408KNX
- KNX-Mallia Senses command 8 push silver 281026DS/F0408KNX
- KNX-Mallia Senses command 8 push white 281026MW/F0408KNX
- KNX-Mallia Senses command 4 push with thermostat brushed black 281027BB/F0204TKNX
- KNX-Mallia Senses command 4 push with thermostat silver 281027DS/F0204TKNX
- KNX-Mallia Senses command 4 push with thermostat white 281027MW/F0204TKNX