EUCHIPS · Order number EUKA6.1 · Actuator

DIN Rail Dimmer 10V10A 6 Channels - KNX

Download .knxprod 6-Channel 0-10V Dimming Actuator 1.1 · 191 KB

Product

ManufacturerEUCHIPS
Product nameEUKA6.1
Order numberEUKA6.1
HardwareEUKA6.1
MediumTwisted Pair
Bus current (mA)15
Rail mountedYes
RegistrationCertified · 2026-06-16
Languagesen-US, zh-CN
Catalog entryM-018D_H-M.2FDA.201110.20D005.20-10-O0073_HP-2091-11-F034-O0073_CI-EUKA6.2E1-0
FingerprintF034
SHA-25675dc91d506fc8d07decfe2e1793a232b62bfb4cb0f112336dc4aea9bc0e69746
First seen2026-11-25
Markets66 markets

Application program: 6-Channel 0-10V Dimming Actuator (V1.1) 1.1

Application number$2091
Version1.1
Mask versionMV-0701 (7.1)
KNX Data SecureNo
Parameters1124
Group objects136
Group objects (136)
NoNameFunctionSizeDPTFlags
0GeneralHeartbeat telegram1 Bit1.3 enableCT
1GeneralSequence 11 Bit1.10 start/stopCWU
2GeneralSequence 21 Bit1.10 start/stopCWU
3GeneralSequence 31 Bit1.10 start/stopCWU
4GeneralSequence 41 Bit1.10 start/stopCWU
5GeneralSequence 51 Bit1.10 start/stopCWU
6XX1 BitCRWTU
7XX1 BitCRWTU
8XX1 BitCRWTU
9XX1 BitCRWTU
10Output AChannel output1 Bit1.1 switchCWU
11Output ARelative dimming(4bit)4 Bit3.7 dimming controlCWU
12Output AAbsolute dimming(8bit)1 Byte5.1 percentage (0..100%)CWU
13Output Aresponse state(1bit)1 Bit1.1 switchCRT
14Output Aresponse state(1byte)1 Byte5.1 percentage (0..100%)CRT
15Output AR/W total ON time2 Bytes7.7 time (h)CRWTU
16Output AAlarm when total ON time out1 Bit1.5 alarmCRT
17Output AStaircase light1 Bit1.1 switchCWU
18Output AChange staircase light time2 Bytes7.5 time (s)CWU
19Output AAlarm staircase light1 Bit1.5 alarmCRT
20Output AFlashing1 Bit1.1 switchCWU
21Output AScene(8bit)1 Byte18.1 scene controlCWU
22Output AScene dimming(4bit)4 Bit3.7 dimming controlCWU
23Output AThreshold input2 Bytes8.10 percentage difference (%)CWU
24Output AChange threshold 12 Bytes8.10 percentage difference (%)CWU
25Output AChange threshold 22 Bytes8.10 percentage difference (%)CWU
26Output ALogic connection 11 Bit1.2 booleanCWU
27Output ALogic connection 21 Bit1.2 booleanCWU
28Output AHeat with 1bit control1 Bit1.1 switchCWU
28Output AHeat with 1byte control1 Byte5.4 percentage (0..255%)CWU
29Output AForced position1 Bit1.1 switchCWU
30Output BChannel output1 Bit1.1 switchCWU
31Output BRelative dimming(4bit)4 Bit3.7 dimming controlCWU
32Output BAbsolute dimming(8bit)1 Byte5.1 percentage (0..100%)CWU
33Output Bresponse state(1bit)1 Bit1.1 switchCRT
34Output Bresponse state(1byte)1 Byte5.1 percentage (0..100%)CRT
35Output BR/W total ON time2 Bytes7.7 time (h)CRWTU
36Output BAlarm when total ON time out1 Bit1.5 alarmCRT
37Output BStaircase light1 Bit1.1 switchCWU
38Output BChange staircase light time2 Bytes7.5 time (s)CWU
39Output BAlarm staircase light1 Bit1.5 alarmCRT
40Output BFlashing1 Bit1.1 switchCWU
41Output BScene(8bit)1 Byte18.1 scene controlCWU
42Output BScene dimming(4bit)4 Bit3.7 dimming controlCWU
43Output BThreshold input1 Byte5.4 percentage (0..255%)CWU
44Output BChange threshold 11 Byte5.4 percentage (0..255%)CWU
45Output BChange threshold 21 Byte5.4 percentage (0..255%)CWU
46Output BLogic connection 11 Bit1.2 booleanCWU
47Output BLogic connection 21 Bit1.2 booleanCWU
48Output BHeat with 1bit control1 Bit1.1 switchCWU
48Output BHeat with 1byte control1 Byte5.4 percentage (0..255%)CWU
49Output BForced position1 Bit1.1 switchCWU
50Output CChannel output1 Bit1.1 switchCWU
51Output CRelative dimming(4bit)4 Bit3.7 dimming controlCWU
52Output CAbsolute dimming(8bit)1 Byte5.1 percentage (0..100%)CWU
53Output Cresponse state(1bit)1 Bit1.1 switchCRT
54Output Cresponse state(1byte)1 Byte5.1 percentage (0..100%)CRT
55Output CR/W total ON time2 Bytes7.7 time (h)CRWTU
56Output CAlarm when total ON time out1 Bit1.5 alarmCRT
57Output CStaircase light1 Bit1.1 switchCWU
58Output CChange staircase light time2 Bytes7.5 time (s)CWU
59Output CAlarm staircase light1 Bit1.5 alarmCRT
60Output CFlashing1 Bit1.1 switchCWU
61Output CScene(8bit)1 Byte18.1 scene controlCWU
62Output CScene dimming(4bit)4 Bit3.7 dimming controlCWU
63Output CThreshold input1 Byte5.4 percentage (0..255%)CWU
64Output CChange threshold 11 Byte5.4 percentage (0..255%)CWU
65Output CChange threshold 21 Byte5.4 percentage (0..255%)CWU
66Output CLogic connection 11 Bit1.2 booleanCWU
67Output CLogic connection 21 Bit1.2 booleanCWU
68Output CHeat with 1bit control1 Bit1.1 switchCWU
68Output CHeat with 1byte control1 Byte5.4 percentage (0..255%)CWU
69Output CForced position1 Bit1.1 switchCWU
70Output DChannel output1 Bit1.1 switchCWU
71Output DRelative dimming(4bit)4 Bit3.7 dimming controlCWU
72Output DAbsolute dimming(8bit)1 Byte5.1 percentage (0..100%)CWU
73Output Dresponse state(1bit)1 Bit1.1 switchCRT
74Output Dresponse state(1byte)1 Byte5.1 percentage (0..100%)CRT
75Output DR/W total ON time2 Bytes7.7 time (h)CRWTU
76Output DAlarm when total ON time out1 Bit1.5 alarmCRT
77Output DStaircase light1 Bit1.1 switchCWU
78Output DChange staircase light time2 Bytes7.5 time (s)CWU
79Output DAlarm staircase light1 Bit1.5 alarmCRT
80Output DFlashing1 Bit1.1 switchCWU
81Output DScene(8bit)1 Byte18.1 scene controlCWU
82Output DScene dimming(4bit)4 Bit3.7 dimming controlCWU
83Output DThreshold input1 Byte5.4 percentage (0..255%)CWU
84Output DChange threshold 11 Byte5.4 percentage (0..255%)CWU
85Output DChange threshold 21 Byte5.4 percentage (0..255%)CWU
86Output DLogic connection 11 Bit1.2 booleanCWU
87Output DLogic connection 21 Bit1.2 booleanCWU
88Output DHeat with 1bit control1 Bit1.1 switchCWU
88Output DHeat with 1byte control1 Byte5.4 percentage (0..255%)CWU
89Output DForced position1 Bit1.1 switchCWU
90Output EChannel output1 Bit1.1 switchCWU
91Output ERelative dimming(4bit)4 Bit3.7 dimming controlCWU
92Output EAbsolute dimming(8bit)1 Byte5.1 percentage (0..100%)CWU
93Output Eresponse state(1bit)1 Bit1.1 switchCRT
94Output Eresponse state(1byte)1 Byte5.1 percentage (0..100%)CRT
95Output ER/W total ON time2 Bytes7.7 time (h)CRWTU
96Output EAlarm when total ON time out1 Bit1.5 alarmCRT
97Output EStaircase light1 Bit1.1 switchCWU
98Output EChange staircase light time2 Bytes7.5 time (s)CWU
99Output EAlarm staircase light1 Bit1.5 alarmCRT
100Output EFlashing1 Bit1.1 switchCWU
101Output EScene(8bit)1 Byte18.1 scene controlCWU
102Output EScene dimming(4bit)4 Bit3.7 dimming controlCWU
103Output EThreshold input1 Byte5.4 percentage (0..255%)CWU
104Output EChange threshold 11 Byte5.4 percentage (0..255%)CWU
105Output EChange threshold 21 Byte5.4 percentage (0..255%)CWU
106Output ELogic connection 11 Bit1.2 booleanCWU
107Output ELogic connection 21 Bit1.2 booleanCWU
108Output EHeat with 1bit control1 Bit1.1 switchCWU
108Output EHeat with 1byte control1 Byte5.4 percentage (0..255%)CWU
109Output EForced position1 Bit1.1 switchCWU
110Output FChannel output1 Bit1.1 switchCWU
111Output FRelative dimming(4bit)4 Bit3.7 dimming controlCWU
112Output FAbsolute dimming(8bit)1 Byte5.1 percentage (0..100%)CWU
113Output Fresponse state(1bit)1 Bit1.1 switchCRT
114Output Fresponse state(1byte)1 Byte5.1 percentage (0..100%)CRT
115Output FR/W total ON time2 Bytes7.7 time (h)CRWTU
116Output FAlarm when total ON time out1 Bit1.5 alarmCRT
117Output FStaircase light1 Bit1.1 switchCWU
118Output FChange staircase light time2 Bytes7.5 time (s)CWU
119Output FAlarm staircase light1 Bit1.5 alarmCRT
120Output FFlashing1 Bit1.1 switchCWU
121Output FScene(8bit)1 Byte18.1 scene controlCWU
122Output FScene dimming(4bit)4 Bit3.7 dimming controlCWU
123Output FThreshold input1 Byte5.4 percentage (0..255%)CWU
124Output FChange threshold 11 Byte5.4 percentage (0..255%)CWU
125Output FChange threshold 21 Byte5.4 percentage (0..255%)CWU
126Output FLogic connection 11 Bit1.2 booleanCWU
127Output FLogic connection 21 Bit1.2 booleanCWU
128Output FHeat with 1bit control1 Bit1.1 switchCWU
128Output FHeat with 1byte control1 Byte5.4 percentage (0..255%)CWU
129Output FForced position1 Bit1.1 switchCWU
Parameters (175)
ParameterTypeDefault
System delay operation after recovery(2..255s)unsignedInt 2…2552
Heartbeat telegramlistDisable
NULLlistNo
-Telegram is sent time interval(1..65535s)unsignedInt 1…655355
Enable sequence 1listDisable
Enable sequence 2listDisable
Enable sequence 3listDisable
Enable sequence 4listDisable
Enable sequence 5listDisable
Operaton mode of the sequence 1listStart with "1",Stop with "0"
Control mode of the sequence 1listFWD
Runing mode of the sequence 1listCycle
Runing time(0..255 hours,0h&0m-unlimited)unsignedInt 0…2550
Runing time(0..59 mins,0h&0m-unlimited)unsignedInt 0…590
Position after running time outlistInvalid
>>Step 1 configurationlistInvalid
Time for step 1 (0..65535s)unsignedInt 0…655355
Time for step 1 (0..999ms)unsignedInt 0…9990
>>Step 2 configurationlistInvalid
Time for step 2 (0..65535s)unsignedInt 0…655355
Time for step 2 (0..999ms)unsignedInt 0…9990
>>Step 3 configurationlistInvalid
Time for step 3 (0..65535s)unsignedInt 0…655355
Time for step 3 (0..999ms)unsignedInt 0…9990
>>Step 4 configurationlistInvalid
Time for step 4 (0..65535s)unsignedInt 0…655355
Time for step 4 (0..999ms)unsignedInt 0…9990
>>Step 5 configurationlistInvalid
Time for step 5 (0..65535s)unsignedInt 0…655355
Time for step 5 (0..999ms)unsignedInt 0…9990
>>Step 6 configurationlistInvalid
Time for step 6 (0..65535s)unsignedInt 0…655355
Time for step 6 (0..999ms)unsignedInt 0…9990
>>Step 7 configurationlistInvalid
Time for step 7 (0..65535s)unsignedInt 0…655355
Time for step 7 (0..999ms)unsignedInt 0…9990
>>Step 8 configurationlistInvalid
Time for step 8 (0..65535s)unsignedInt 0…655355
Time for step 8 (0..999ms)unsignedInt 0…9990
>>Step 9 configurationlistInvalid
Time for step 9 (0..65535s)unsignedInt 0…655355
Time for step 9 (0..999ms)unsignedInt 0…9990
>>Step 10 configurationlistInvalid
Time for step 10 (0..65535s)unsignedInt 0…655355
Time for step 10 (0..999ms)unsignedInt 0…9990
>>Step 11 configurationlistInvalid
Time for step 11 (0..65535s)unsignedInt 0…655355
Time for step 11 (0..999ms)unsignedInt 0…9990
>>Step 12 configurationlistInvalid
Time for step 12 (0..65535s)unsignedInt 0…655355
Time for step 12 (0..999ms)unsignedInt 0…9990
>>Step 13 configurationlistInvalid
Time for step 13 (0..65535s)unsignedInt 0…655355
Time for step 13 (0..999ms)unsignedInt 0…9990
>>Step 14 configurationlistInvalid
Time for step 14 (0..65535s)unsignedInt 0…655355
Time for step 14 (0..999ms)unsignedInt 0…9990
>>Step 15 configurationlistInvalid
Time for step 15 (0..65535s)unsignedInt 0…655355
Time for step 15 (0..999ms)unsignedInt 0…9990
>>Step 16 configurationlistInvalid
Time for step 16 (0..65535s)unsignedInt 0…655355
Time for step 16 (0..999ms)unsignedInt 0…9990
>>Step 17 configurationlistInvalid
Time for step 17 (0..65535s)unsignedInt 0…655355
Time for step 17 (0..999ms)unsignedInt 0…9990
>>Step 18 configurationlistInvalid
Time for step 18 (0..65535s)unsignedInt 0…655355
Time for step 18 (0..999ms)unsignedInt 0…9990
>>Step 19 configurationlistInvalid
Time for step 19 (0..65535s)unsignedInt 0…655355
Time for step 19 (0..999ms)unsignedInt 0…9990
>>Step 20 configurationlistInvalid
Time for step 20 (0..65535s)unsignedInt 0…655355
Time for step 20 (0..999ms)unsignedInt 0…9990
>>Step 21 configurationlistInvalid
Time for step 21 (0..65535s)unsignedInt 0…655355
Time for step 21 (0..999ms)unsignedInt 0…9990
>>Step 22 configurationlistInvalid
Time for step 22 (0..65535s)unsignedInt 0…655355
Time for step 22 (0..999ms)unsignedInt 0…9990
>>Step 23 configurationlistInvalid
Time for step 23 (0..65535s)unsignedInt 0…655355
Time for step 23 (0..999ms)unsignedInt 0…9990
>>Step 24 configurationlistInvalid
Time for step 24 (0..65535s)unsignedInt 0…655355
Time for step 24 (0..999ms)unsignedInt 0…9990
Operaton mode of the sequence 2listStart with "1",Stop with "0"
Control mode of the sequence 2listFWD
Runing mode of the sequence 2listCycle
Operaton mode of the sequence 3listStart with "1",Stop with "0"
Control mode of the sequence 3listFWD
Runing mode of the sequence 3listCycle
Operaton mode of the sequence 4listStart with "1",Stop with "0"
Control mode of the sequence 4listFWD
Runing mode of the sequence 4listCycle
Operaton mode of the sequence 5listStart with "1",Stop with "0"
Control mode of the sequence 5listFWD
Runing mode of the sequence 5listCycle
Dimming output rangelist0-10v
The response of channel state(1bit)listInvalid
The response of channel state(1byte)listInvalid
Statistics total ON time to allowed(0..65535h=7.4years)listDisable
Alarm when time out(1..65535h,0-invalid)unsignedInt 0…6553530000
Transmit telegram interval when alarm(1..255s)unsignedInt 1…25510
The status after bus voltage recoverylistOFF
Brightness valuelist0%(0)
Maximum levellist100%(255)
Upper threshold levellist100%(255)
Lower threshold levellist0%(0)
Dimming minimum levellist0%(0)
Show the function page ==>>listDisable
Enable switch ON/OFFlistEnable
-Switching ON fade time(0..255s)unsignedInt 0…2553
-Switching OFF fade time(0..255s)unsignedInt 0…2553
-Switching ON when light OFFlistNormal
-Switching OFF when light ONlistNormal
Enable relative dimminglistEnable
-Relative(4bits) dimming fade time(brightness0%..100%/2..255s)unsignedInt 2…2555
-Relative dimming is saved as the brightness of the switchlistNo
Enable absolute dimminglistEnable
-Absolute(1byte) dimming fade time(brightness0%..100%/0..255s)unsignedInt 0…2555
-Absolute dimming is saved as the brightness of the switchlistNo
Enable function "staircase light"listDisable
Enable function "flashing"listDisable
Enable function "scene"listDisable
Enable function "threshold"listDisable
Enable function "logic"listDisable
Enable function "heating"listDisable
Staircase light operationlistStart with "1",Stop with "0"
Brightness valuelist100%(255)
Fade time of brighter(0..255s)unsignedInt 0…2553
Fade time of darker(0..255s)unsignedInt 0…2553
Duration time for brightness(0..255min)unsignedInt 0…2550
Duration time for brightness(0..59sec)unsignedInt 0…595
Change staircase light time via buslistDisable
Alarm staircase light via buslistDisable
Flashing operationlistStart with "1",Stop with "0"
Duration time for darkness(0..255min)unsignedInt 0…2550
Duration time for darkness(0..59sec)unsignedInt 0…595
Flashing number(1..255,0-Unlimited)unsignedInt 0…2550
Brightness after achieves the flashing numberlistInvalid
Fade time of scene dimming(2..255s)unsignedInt 2…2555
>>Output assigned to(scene 1..64 )listNot allocate
Output brightness valuelist100%(255)
Fade time for brighter/darker(0..255s)unsignedInt 0…2553
Brightness value for switch ON of thresholdlist100%(255)
Fade time for switch ON of threshold(0..255s)unsignedInt 0…2553
Fade time for switch OFF of threshold(0..255s)unsignedInt 0…2553
Threshold 1 value is(0..255)unsignedInt 0…25580
Threshold 2 value is(0..255)unsignedInt 0…255180
Input value<Lower thresholdlistOFF
Lower threshold<=Input value<=Upper thresholdlistON
Input value>Upper thresholdlistOFF
Change threshold 1 via buslistDisable
Change threshold 2 via buslistDisable
Logic connection 1 enablelistDisable
Function of logic block1listAND
Object value of logic connection 1 after bus voltage recoverylist"0"
Result of logic block1 invertedlistNo
Logic connection 2 enablelistDisable
Function of logic block2listAND
Object value of logic connection 2 after bus voltage recoverylist"0"
Result of logic block2 invertedlistNo
Brightness value for switch ON of heatinglist100%(255)
Fade time for switch ON of heating(0..255s)unsignedInt 0…2551
Fade time for switch OFF of heating(0..255s)unsignedInt 0…2551
PWM cycle time set(1..65535min)unsignedInt 1…655351
PWM cycle time set(0..59sec)unsignedInt 0…590
Control telegram is received aslist1bit pwm("ON"-start,"OFF"-stop)
The scale of ONlist50%(128)
Running automatically after bus voltage recoverylistNO
-Position of the valvelist50%(128)
Forced position of PWMlistNo
-Valve of PWMlist50%(128)

Version history

ApplicationApp noFingerprintFirst seenSizeFile
6-Channel 0-10V Dimming Actuator 1.1 latest$2091F0342026-11-25191 KBDownload

About this file

This is the official ETS product database for the EUCHIPS EUKA6.1 (EUKA6.1), published by the manufacturer in the KNX online catalog. To use it, open ETS, go to Catalogs → Import and choose the downloaded .knxprod file. The device then appears in your catalog and can be added to a project. Older versions are kept so existing projects can be matched to the application program they were commissioned with.