ESYLUX PD-FLAT 360i/8 KNX EP10451768

ESYLUX · Order number EP10451768 · Präsenzmelder › Deckenpräsenzmelder 8m

Download .knxprod ESYLUX_PD_FLAT 1.0 · 138 KB

Product

ManufacturerESYLUX
Product nameESYLUX PD-FLAT 360i/8 KNX
Order numberEP10451768
HardwareESYLUX PD-FLAT 360i/8 KNX
MediumTwisted Pair
Bus current (mA)6
Rail mountedNo
RegistrationRegistered · 2016-11-15
Languagesde-DE, en-US, fr-FR
Catalog entryM-0080_H-2015.5F08.5F06-1_HP-7090-10-740E-O00C5_CI-EP10451768-1
Fingerprint740E
SHA-256c21d4029698ece16ff4f00460128d27ac096ae31a03452b0f0f5cf23322ca728
First seen2026-11-25
MarketsAustria, Belgium, Germany, Netherlands, United Kingdom

Application program: ESYLUX_PD_FLAT 1.0

Application number$7090
Version1.0
Mask versionMV-0705 (7.5)
KNX Data SecureNo
Parameters148
Group objects57
Group objects (57)
NoNameFunctionSizeDPTFlags
0Input: Lock light-channel1 Bit1.1 switchCW
1Input: Light-Channel 1 manual ON/OFF1 Bit1.1 switchCW
2Input: Light-Channel 2 manual ON/OFF1 Bit1.1 switchCW
3Input: Light-Channel 1 manual dimming4 Bit3.7 dimming controlCW
4Input: Light-Channel 2 manual dimming4 Bit3.7 dimming controlCW
5Input: Light-Channel 1 manual dim value1 Byte5.1 percentage (0..100%)CW
6Input: Light-Channel 2 manual dim value1 Byte5.1 percentage (0..100%)CW
7Input: Light-Channel controlling w/o presence1 Bit1.1 switchCW
7Input: Light-Channel control without presence1 Bit1.1 switchCW
8Output: Light-Channel 1 ON/OFF1 Bit1.1 switchCRT
9Output: Light-Channel 2 ON/OFF1 Bit1.1 switchCRT
10Output: Light-Channel 1 dimming4 Bit3.7 dimming controlCRT
10Output: Light-Channel 1 scene1 Byte5.1 percentage (0..100%)CRT
11Output: Light-Channel 2 dimming1 Byte17.1 scene numberCRT
11Output: Light-Channel 2 dimming4 Bit3.7 dimming controlCRT
12Output: Light-Channel 1 dim value1 Byte5.1 percentage (0..100%)CRT
13Output: Light-Channel 2 dim value1 Byte5.1 percentage (0..100%)CRT
14Input: Light-Channel Regulating lower light value2 Bytes7.13 brightness (lux)CW
14Input: Light-Channel 1 Threshold2 Bytes7.13 brightness (lux)CW
14Input: Light-Channel setpoint controlling2 Bytes7.13 brightness (lux)CW
15Input: Light-Channel 2 Threshold2 Bytes7.13 brightness (lux)CW
15Input: Light-Channel regulating lower light value2 Bytes7.13 brightness (lux)CW
16Input: Light-Channel feedback actuator1 Bit1.1 switchCW
16Input: Light-Channel 1 feedback actuator1 Bit1.1 switchCW
17Input: Light-Channel 2 feedback actuator1 Bit1.1 switchCW
18Input: Light-Channel select Orientation light1 Bit1.1 switchCW
19Input: Light-Channel Orientation light ON/OFF1 Bit1.1 switchCW
20Input: Light-Channel Slumber funktion ON/OFF1 Bit1.1 switchCW
22Input: lock sending light value1 Bit1.1 switchCW
22Input: Light-Channel Half-/Full automatic1 Bit1.1 switchCW
23Input: external light value2 Bytes9.4 lux (Lux)CW
24Output: internal light value 12 Bytes9.4 lux (Lux)CRT
25Output: internal light value 22 Bytes9.4 lux (Lux)CRT
26Output: Current light value2 Bytes9.4 lux (Lux)CRT
27Input: HVAC-channel lock1 Bit1.1 switchCW
28Input: HVAC-channel On/Off1 Bit1.1 switchCW
29Output: HVAC-channel On/Off1 Bit1.1 switchCRT
30Output: HVAC-channel dim value1 Byte5.1 percentage (0..100%)CRT
31Output: HVAC-channel scene1 Byte5.1 percentage (0..100%)CRT
32Input: Slave/Master motion1 Bit1.1 switchCW
33Input: lock motion detection1 Bit1.1 switchCW
34Output: motion detection1 Bit1.1 switchCRT
34Output: motion detection Sensor pane 11 Bit1.1 switchCRT
35Output: motion detection sensor pane 21 Bit1.1 switchCRT
36Output: motion detection sensor pane 31 Bit1.1 switchCRT
37Output: motion detection sensor pane 41 Bit1.1 switchCRT
38Input: Twilight switch manual On/Off1 Bit1.1 switchCW
39Output: Twilight switch On/Off1 Bit1.1 switchCRT
40Output: Twilight switch dim value1 Byte5.1 percentage (0..100%)CRT
41Output: Twilight switch scene1 Byte17.1 scene numberCRT
42Input: Presence simulation On/Off1 Bit1.1 switchCW
43Input: night light On/Off1 Bit1.1 switchCW
44Input: Alarm lock1 Bit1.1 switchCW
45Input: Alarm manual On/Off1 Bit1.1 switchCW
46Output: Alarm On/Off1 Bit1.1 switchCRT
46Output: Sensor status1 Bit1.1 switchCRT
47Input: Reset1 Bit1.1 switchCW
Parameters (91)
ParameterTypeDefault
Configuration of devicelistMaster
Test mode (activated for 10min. After download by choosing „On“)listOff
Behavior after ETS download/resetlistno reaction
RemotelistOff
LED in sensorlistvery bright
MultiplicatorunsignedInt 1…601
Color when motion is detected“listgreen
Color when motion detection is lockedlistred
Color sensor in programming mode (blue, when application not programmed)listblue
Nightlight functionlistOff
Color when threshold is underrunlistOff
Threshold (Lux)unsignedInt 0…200050
Hysteresis (Lux)unsignedInt 0…10010
Interval between motion detction (1…240 seconds)unsignedInt 3…2403
Cyclic sending of On-telegramen at motion detectionlistNo
Sending Off-telegram after last motion detectionlistYes
Sensitivitysensorlist100,00%
Light dependend sending of motion detectionlistNot light dependend
Threshold (Lux)unsignedInt 0…2000500
Hysteresis (Lux)unsignedInt 0…10050
Motion sensors are locked bylistOn-telegram
Presence simulationlistNo
External Master/Slavelistdeactivated
Operating modelistFull automatic
Functionlistswitching
Switch off time light channel (0 = no switch off time )list5 minutes
Manual operation activelistaktiv while presence
manual operationlistactive while presence
Locktime after manual operation (minutes)unsignedInt 0…24030
Off-period after manual operation (Min., 0 = regulating starts immediately)unsignedInt 0…24030
Off-period after manual operation (Min., 0 = controlling starts immediately)unsignedInt 0…24030
telegram interval for cyclic sendinglistno cyclic sending
Processing actuator feedbacklistNo
MultiplicatorunsignedInt 1…241
cyclic sending oflistOn- and Off-telegrams
Behavior at switching on lock by communication objectlistno reaction
Behavior at switching off lock by communication objectlistno reaction
Telegramfilterlistdeactivated
Lighting controlled regardless of presencelistdeactivated
Lighting regulated regardless of presencelistdeactivated
threshold (Lux, 0 = deactivated)unsignedInt 0…2000500
Threshold 1 (Lux, 0 = deactivated)unsignedInt 0…2000500
Lower light value (Lux, dim value = 100%)unsignedInt 0…20000
Difference between threshold 1 and threshold 2 (-100% ... 100%)signedInt -100…1000
Upper light value (Lux, dim value = 0%)unsignedInt 0…2000500
Set value via telegramlistOff
dim value on switching on (0...100%)unsignedInt 0…10060
Preset limit values via telegramlistOff
Maximum dim value step (0...10%)unsignedInt 0…103
Minimal dim value step (0...10%)unsignedInt 0…100
Minimal dim value (0...100%)unsignedInt 0…1000
Maximum dim value (0...100%)unsignedInt 0…100100
Control timinglist2 seconds
Preset thresholds via telegramlistOff
Orientation lightlistOn
Output telegram binarylistOn
Orientation light value 1 (%)list10,00%
Output telegram dim valuelistOff
Orientation light value 2 (%)list25,00%
Sended value at On switching (%)unsignedInt 0…100100
Orientation light duration (minutes, 0 = always on)unsignedInt 0…2505
Sended value at Off switching (%)unsignedInt 0…1000
Offset between dimm value 1 and dimm value 2 (-100% ... 100%)signedInt -100…1000
Output telegrame scenelistOff
Sended scene at On switchingunsignedInt 1…641
Sended scene at Off switchingunsignedInt 1…642
Snooze funktionlistOff
dim value at snooze funktion (%)unsignedInt 0…10020
Operation modelistFull automatic
Delay presence output (0 = no delay)list0
Switch off time (0 = no switch off time )list60 minutes
sendet value at On switching (%)unsignedInt 0…100100
sendet value at Off switching (%)unsignedInt 0…1000
Output telegram scenelistOff
Threshold twilight switch(Lux)unsignedInt 0…200050
Timedelay of twilight switch (minutes)unsignedInt 1…601
Offperiod after manual operation (minutes)unsignedInt 1…6010
telegram interval light valuelistno cyclic sending
Offset light valuesignedInt -2000…20000
Sending light value above a difference of (Lux, 0 = deactivated)unsignedInt 0…200050
Internal light value Base (0...100)unsignedInt 0…1001
Multiplicatorlistx 1,0
Processing external light valuelistNo
External light value base (0...100)unsignedInt 0…1001
At activating lock sending light valuelistlocking deactivated
Sended light value at on switching lock (Lux)signedInt -2000…20000
Same behavior at switching On and Off switchinglistYes
Duration of one switch-on/off windowslist0,3 seconds
Number of switch On windows (0 = switching On immediately at motion)unsignedInt 0…10010
Alarm must be acknowledgedlistYes
Number of switch Off windows (0 = switching Off immediately at motion)unsignedInt 0…1000

Version history

ApplicationApp noFingerprintFirst seenSizeFile
ESYLUX_PD_FLAT 1.0 latest$7090740E2026-11-25138 KBDownload

About this file

This is the official ETS product database for the ESYLUX ESYLUX PD-FLAT 360i/8 KNX (EP10451768), published by the manufacturer in the KNX online catalog. To use it, open ETS, go to Catalogs → Import and choose the downloaded .knxprod file. The device then appears in your catalog and can be added to a project. Older versions are kept so existing projects can be matched to the application program they were commissioned with.