Eelectron MC06A01KNX MC06A01KNX CO2 / Humidity / Temperature Controller - A01

MC06A01KNX CO2 / Humidity / Temperature Controller - A01 MC06A01KNX

Eelectron · Order number MC06A01KNX · 9025 › Sensors

Download .knxprod MC06A01KNX CO2 / Humidity / Temperature Controller 1.0 · 602 KB

Product

ManufacturerEelectron
Product nameMC06A01KNX CO2 / Humidity / Temperature Controller - A01
Order numberMC06A01KNX
Product textCO2 / Humidity / Temperature Controller - A01
HardwareMC06A01KNX
MediumTwisted Pair
Bus current (mA)30
Rail mountedNo
RegistrationCertified · 2020-07-27
Languagesfr-FR, it-IT, en-US, de-DE, es-ES, ru-RU
Catalog entryM-006C_H-MC06A01KNX-0_HP-0677-10-EF34_CI-MC06A01KNX-1
FingerprintEF34
SHA-2560e5790745fe7bd78a0e0cfa7ebe749ebe304a34a4871c45052fad1facd34c638
First seen2026-11-25
Markets59 markets

Application program: MC06A01KNX CO2 / Humidity / Temperature Controller 1.0

Application number$0677
Version1.0
Mask versionMV-0021 (2.1)
KNX Data SecureNo
Minimum ETS version4.0
Parameters2679
Group objects1199
Group objects (1199)
NoNameFunctionSizeDPTFlags
0<General> Panel AlarmOff-On1 Bit1.1 switchCRT
1<General> CleaningOff/On1 Bit1.1 switchCW
2<General> Brightness in OFF mode0-100%1 Byte5.1 percentage (0..100%)CW
3<General> Brightness in ON mode0-100%1 Byte5.1 percentage (0..100%)CW
4<General> Standby Brightness in OFF mode0-100%1 Byte5.1 percentage (0..100%)CW
5<General> Standby Brightness in ON mode0-100%1 Byte5.1 percentage (0..100%)CW
6<Proximity> Send CommandOff/On1 Bit1.1 switchCRT
7<Button {{61:1}}> RGB3 Bytes3 Bytes232.600 RGB value 3x(0..255)CRT
7<Button {{61:1}}> Red0-2551 Byte5.10 counter pulses (0..255)CRT
7<Button {{61:1}}> Press Action0-2551 Byte5.10 counter pulses (0..255)CRT
7<Button {{61:1}}> Press Action0-100%1 Byte5.1 percentage (0..100%)CRT
7<Button {{61:1}}> Press ActionHVAC Mode1 Byte20.102 HVAC modeCRT
7<Button {{61:1}}> Press - Release Action0-2551 Byte5.10 counter pulses (0..255)CRT
7<Button {{61:1}}> Press - Release Action0-100%1 Byte5.1 percentage (0..100%)CRT
7<Button {{61:1}}> Press - Release ActionHVAC Mode1 Byte20.102 HVAC modeCRT
7<Button {{61:1}}> Short Press0-2551 Byte5.10 counter pulses (0..255)CRT
7<Button {{61:1}}> Short Press0-100%1 Byte5.1 percentage (0..100%)CRT
7<Button {{61:1}}> Short PressHVAC Mode1 Byte20.102 HVAC modeCRT
7<Button {{61:1}}> Short - Long Press0-2551 Byte5.10 counter pulses (0..255)CRT
7<Button {{61:1}}> Short - Long Press0-100%1 Byte5.1 percentage (0..100%)CRT
7<Button {{61:1}}> Short - Long PressHVAC Mode1 Byte20.102 HVAC modeCRT
7<Button {{61:1}}> Recall/Learn SceneScene1 Byte18.1 scene controlCRT
7<Button {{61:1}}> Sequence Command A 0-2550-2551 Byte5.10 counter pulses (0..255)CRT
7<Button {{61:1}}> Sequence Command A 0-100%0-100%1 Byte5.1 percentage (0..100%)CRT
7<Button {{61:1}}> Sequence Command A HVAC ModeHVAC Mode1 Byte20.102 HVAC modeCRT
7<Button {{61:1}}> Sequence Command A 0-255-Toggle0-2551 Byte5.10 counter pulses (0..255)CRT
7<Button {{61:1}}> Sequence Command A 0-100%-Toggle0-100%1 Byte5.1 percentage (0..100%)CRT
7<Button {{61:1}}> Sequence Command A HVAC Mode-ToggleHVAC Mode1 Byte20.102 HVAC modeCRT
7<Button {{61:1}}> Press ActionOff/On1 Bit1.1 switchCRWT
7<Button {{61:1}}> Press - Release ActionOff/On1 Bit1.1 switchCRWT
7<Button {{61:1}}> Short PressOff/On1 Bit1.1 switchCRWT
7<Button {{61:1}}> Short - Long PressOff/On1 Bit1.1 switchCRWT
7<Button {{61:1}}> Dimming On/OffOff/On1 Bit1.1 switchCRWT
7<Button {{61:1}}> Object AOff/On1 Bit1.1 switchCRT
7<Button {{61:1}}> Shutter - Up/DownUp/Down1 Bit1.8 up/downCRWT
7<Button {{61:1}}> Sequence Command A Off/OnOff/On1 Bit1.1 switchCRT
7<Button {{61:1}}> Sequence Command A Off/On-ToggleOff/On1 Bit1.1 switchCRT
7<Button {{61:1}}> Make Up RoomOff/On1 Bit1.1 switchCRWT
7<Special Button {{1050:1}}> Enable ObjectDisable/Enable1 Bit1.3 enableCW
8<Button {{61:1}}> Green0-2551 Byte5.10 counter pulses (0..255)CRT
8<Button {{61:1}}> Long Press0-2551 Byte5.10 counter pulses (0..255)CRT
8<Button {{61:1}}> Long Press0-100%1 Byte5.1 percentage (0..100%)CRT
8<Button {{61:1}}> Long PressHVAC Mode1 Byte20.102 HVAC modeCRT
8<Button {{61:1}}> Release Action0-2551 Byte5.10 counter pulses (0..255)CRT
8<Button {{61:1}}> Release Action0-100%1 Byte5.1 percentage (0..100%)CRT
8<Button {{61:1}}> Release ActionHVAC Mode1 Byte20.102 HVAC modeCRT
8<Button {{61:1}}> Sequence Command B 0-2550-2551 Byte5.10 counter pulses (0..255)CRT
8<Button {{61:1}}> Sequence Command B 0-100%0-100%1 Byte5.1 percentage (0..100%)CRT
8<Button {{61:1}}> Sequence Command B HVAC ModeHVAC Mode1 Byte20.102 HVAC modeCRT
8<Button {{61:1}}> Sequence Command B 0-255-Toggle0-2551 Byte5.10 counter pulses (0..255)CRT
8<Button {{61:1}}> Sequence Command B 0-100%-Toggle0-100%1 Byte5.1 percentage (0..100%)CRT
8<Button {{61:1}}> Sequence Command B HVAC Mode-ToggleHVAC Mode1 Byte20.102 HVAC modeCRT
8<Button {{61:1}}> Loop Value OutputLoop Value Output1 Byte5.10 counter pulses (0..255)CRT
8<Button {{61:1}}> Dimming ControlBrighter/Darker4 Bit3.7 dimming controlCRT
8<Button {{61:1}}> Long PressOff/On1 Bit1.1 switchCRWT
8<Button {{61:1}}> Release ActionOff/On1 Bit1.1 switchCRWT
8<Button {{61:1}}> Object BOff/On1 Bit1.1 switchCRT
8<Button {{61:1}}> Shutter - Step/StopStep/Stop1 Bit1.7 stepCRT
8<Button {{61:1}}> Sequence Command B Off/OnOff/On1 Bit1.1 switchCRT
8<Button {{61:1}}> Sequence Command B Off/On-ToggleOff/On1 Bit1.1 switchCRT
8<Button {{61:1}}> Send Learn Scene TriggerDisable/Enable1 Bit1.3 enableCW
8<Button {{61:1}}> Do Not DisturbOff/On1 Bit1.1 switchCRWT
9<Button {{61:1}}> Additional Object RGB3 Bytes3 Bytes232.600 RGB value 3x(0..255)CRT
9<Button {{61:1}}> Blue0-2551 Byte5.10 counter pulses (0..255)CRT
9<Button {{61:1}}> Sequence Command C 0-2550-2551 Byte5.10 counter pulses (0..255)CRT
9<Button {{61:1}}> Sequence Command C 0-100%0-100%1 Byte5.1 percentage (0..100%)CRT
9<Button {{61:1}}> Sequence Command C HVAC ModeHVAC Mode1 Byte20.102 HVAC modeCRT
9<Button {{61:1}}> Sequence Command C 0-255-Toggle0-2551 Byte5.10 counter pulses (0..255)CRT
9<Button {{61:1}}> Sequence Command C 0-100%-Toggle0-100%1 Byte5.1 percentage (0..100%)CRT
9<Button {{61:1}}> Sequence Command C HVAC Mode-ToggleHVAC Mode1 Byte20.102 HVAC modeCRT
9<Button {{61:1}}> Loop Value FeedbackLoop Value Feedback1 Byte5.10 counter pulses (0..255)CW
9<Button {{61:1}}> Sequence Command C Off/OnOff/On1 Bit1.1 switchCRT
9<Button {{61:1}}> Sequence Command C Off/On-ToggleOff/On1 Bit1.1 switchCRT
9<Button {{61:1}}> FeedbackOff/On1 Bit1.1 switchCW
9<Button {{61:1}}> FeedbackUp/Down1 Bit1.8 up/downCW
9<Button {{61:1}}> Object COff/On1 Bit1.1 switchCRT
10<Button {{61:1}}> Enable InputDisable/Enable1 Bit1.3 enableCW
11<Button {{226:2}}> RGB3 Bytes3 Bytes232.600 RGB value 3x(0..255)CRT
11<Button {{226:2}}> Red0-2551 Byte5.10 counter pulses (0..255)CRT
11<Button {{226:2}}> Press Action0-2551 Byte5.10 counter pulses (0..255)CRT
11<Button {{226:2}}> Press Action0-100%1 Byte5.1 percentage (0..100%)CRT
11<Button {{226:2}}> Press ActionHVAC Mode1 Byte20.102 HVAC modeCRT
11<Button {{226:2}}> Press - Release Action0-2551 Byte5.10 counter pulses (0..255)CRT
11<Button {{226:2}}> Press - Release Action0-100%1 Byte5.1 percentage (0..100%)CRT
11<Button {{226:2}}> Press - Release ActionHVAC Mode1 Byte20.102 HVAC modeCRT
11<Button {{226:2}}> Short Press0-2551 Byte5.10 counter pulses (0..255)CRT
11<Button {{226:2}}> Short Press0-100%1 Byte5.1 percentage (0..100%)CRT
11<Button {{226:2}}> Short PressHVAC Mode1 Byte20.102 HVAC modeCRT
11<Button {{226:2}}> Short - Long Press0-2551 Byte5.10 counter pulses (0..255)CRT
11<Button {{226:2}}> Short - Long Press0-100%1 Byte5.1 percentage (0..100%)CRT
11<Button {{226:2}}> Short - Long PressHVAC Mode1 Byte20.102 HVAC modeCRT
11<Button {{226:2}}> Recall/Learn SceneScene1 Byte18.1 scene controlCRT
11<Button {{226:2}}> Sequence Command A 0-2550-2551 Byte5.10 counter pulses (0..255)CRT
11<Button {{226:2}}> Sequence Command A 0-100%0-100%1 Byte5.1 percentage (0..100%)CRT
11<Button {{226:2}}> Sequence Command A HVAC ModeHVAC Mode1 Byte20.102 HVAC modeCRT
11<Button {{226:2}}> Sequence Command A 0-255-Toggle0-2551 Byte5.10 counter pulses (0..255)CRT
11<Button {{226:2}}> Sequence Command A 0-100%-Toggle0-100%1 Byte5.1 percentage (0..100%)CRT
11<Button {{226:2}}> Sequence Command A HVAC Mode-ToggleHVAC Mode1 Byte20.102 HVAC modeCRT
11<Button {{226:2}}> Press ActionOff/On1 Bit1.1 switchCRWT
11<Button {{226:2}}> Press - Release ActionOff/On1 Bit1.1 switchCRWT
11<Button {{226:2}}> Short PressOff/On1 Bit1.1 switchCRWT
11<Button {{226:2}}> Short - Long PressOff/On1 Bit1.1 switchCRWT
11<Button {{226:2}}> Dimming On/OffOff/On1 Bit1.1 switchCRWT
11<Button {{226:2}}> Object AOff/On1 Bit1.1 switchCRT
11<Button {{226:2}}> Shutter - Up/DownUp/Down1 Bit1.8 up/downCRWT
11<Button {{226:2}}> Sequence Command A Off/OnOff/On1 Bit1.1 switchCRT
11<Button {{226:2}}> Sequence Command A Off/On-ToggleOff/On1 Bit1.1 switchCRT
11<Button {{226:2}}> Make Up RoomOff/On1 Bit1.1 switchCRWT
11<Special Button {{1092:2}}> Enable ObjectDisable/Enable1 Bit1.3 enableCW
12<Button {{226:2}}> Green0-2551 Byte5.10 counter pulses (0..255)CRT
12<Button {{226:2}}> Long Press0-2551 Byte5.10 counter pulses (0..255)CRT
12<Button {{226:2}}> Long Press0-100%1 Byte5.1 percentage (0..100%)CRT
12<Button {{226:2}}> Long PressHVAC Mode1 Byte20.102 HVAC modeCRT
12<Button {{226:2}}> Release Action0-2551 Byte5.10 counter pulses (0..255)CRT
12<Button {{226:2}}> Release Action0-100%1 Byte5.1 percentage (0..100%)CRT
12<Button {{226:2}}> Release ActionHVAC Mode1 Byte20.102 HVAC modeCRT
12<Button {{226:2}}> Sequence Command B 0-2550-2551 Byte5.10 counter pulses (0..255)CRT
12<Button {{226:2}}> Sequence Command B 0-100%0-100%1 Byte5.1 percentage (0..100%)CRT
12<Button {{226:2}}> Sequence Command B HVAC ModeHVAC Mode1 Byte20.102 HVAC modeCRT
12<Button {{226:2}}> Sequence Command B 0-255-Toggle0-2551 Byte5.10 counter pulses (0..255)CRT
12<Button {{226:2}}> Sequence Command B 0-100%-Toggle0-100%1 Byte5.1 percentage (0..100%)CRT
12<Button {{226:2}}> Sequence Command B HVAC Mode-ToggleHVAC Mode1 Byte20.102 HVAC modeCRT
12<Button {{226:2}}> Loop Value OutputLoop Value Output1 Byte5.10 counter pulses (0..255)CRT
12<Button {{226:2}}> Dimming ControlBrighter/Darker4 Bit3.7 dimming controlCRT
12<Button {{226:2}}> Long PressOff/On1 Bit1.1 switchCRWT
12<Button {{226:2}}> Release ActionOff/On1 Bit1.1 switchCRWT
12<Button {{226:2}}> Object BOff/On1 Bit1.1 switchCRT
12<Button {{226:2}}> Shutter - Step/StopStep/Stop1 Bit1.7 stepCRT
12<Button {{226:2}}> Sequence Command B Off/OnOff/On1 Bit1.1 switchCRT
12<Button {{226:2}}> Sequence Command B Off/On-ToggleOff/On1 Bit1.1 switchCRT
12<Button {{226:2}}> Send Learn Scene TriggerDisable/Enable1 Bit1.3 enableCW
12<Button {{226:2}}> Do Not DisturbOff/On1 Bit1.1 switchCRWT
13<Button {{226:2}}> Additional Object RGB3 Bytes3 Bytes232.600 RGB value 3x(0..255)CRT
13<Button {{226:2}}> Blue0-2551 Byte5.10 counter pulses (0..255)CRT
13<Button {{226:2}}> Sequence Command C 0-2550-2551 Byte5.10 counter pulses (0..255)CRT
13<Button {{226:2}}> Sequence Command C 0-100%0-100%1 Byte5.1 percentage (0..100%)CRT
13<Button {{226:2}}> Sequence Command C HVAC ModeHVAC Mode1 Byte20.102 HVAC modeCRT
13<Button {{226:2}}> Sequence Command C 0-255-Toggle0-2551 Byte5.10 counter pulses (0..255)CRT
13<Button {{226:2}}> Sequence Command C 0-100%-Toggle0-100%1 Byte5.1 percentage (0..100%)CRT
13<Button {{226:2}}> Sequence Command C HVAC Mode-ToggleHVAC Mode1 Byte20.102 HVAC modeCRT
13<Button {{226:2}}> Loop Value FeedbackLoop Value Feedback1 Byte5.10 counter pulses (0..255)CW
13<Button {{226:2}}> Sequence Command C Off/OnOff/On1 Bit1.1 switchCRT
13<Button {{226:2}}> Sequence Command C Off/On-ToggleOff/On1 Bit1.1 switchCRT
13<Button {{226:2}}> FeedbackOff/On1 Bit1.1 switchCW
13<Button {{226:2}}> FeedbackUp/Down1 Bit1.8 up/downCW
13<Button {{226:2}}> Object COff/On1 Bit1.1 switchCRT
14<Button {{226:2}}> Enable InputDisable/Enable1 Bit1.3 enableCW
15<Button {{391:3}}> RGB3 Bytes3 Bytes232.600 RGB value 3x(0..255)CRT
15<Button {{391:3}}> Red0-2551 Byte5.10 counter pulses (0..255)CRT
15<Button {{391:3}}> Press Action0-2551 Byte5.10 counter pulses (0..255)CRT
15<Button {{391:3}}> Press Action0-100%1 Byte5.1 percentage (0..100%)CRT
15<Button {{391:3}}> Press ActionHVAC Mode1 Byte20.102 HVAC modeCRT
15<Button {{391:3}}> Press - Release Action0-2551 Byte5.10 counter pulses (0..255)CRT
15<Button {{391:3}}> Press - Release Action0-100%1 Byte5.1 percentage (0..100%)CRT
15<Button {{391:3}}> Press - Release ActionHVAC Mode1 Byte20.102 HVAC modeCRT
15<Button {{391:3}}> Short Press0-2551 Byte5.10 counter pulses (0..255)CRT
15<Button {{391:3}}> Short Press0-100%1 Byte5.1 percentage (0..100%)CRT
15<Button {{391:3}}> Short PressHVAC Mode1 Byte20.102 HVAC modeCRT
15<Button {{391:3}}> Short - Long Press0-2551 Byte5.10 counter pulses (0..255)CRT
15<Button {{391:3}}> Short - Long Press0-100%1 Byte5.1 percentage (0..100%)CRT
15<Button {{391:3}}> Short - Long PressHVAC Mode1 Byte20.102 HVAC modeCRT
15<Button {{391:3}}> Recall/Learn SceneScene1 Byte18.1 scene controlCRT
15<Button {{391:3}}> Sequence Command A 0-2550-2551 Byte5.10 counter pulses (0..255)CRT
15<Button {{391:3}}> Sequence Command A 0-100%0-100%1 Byte5.1 percentage (0..100%)CRT
15<Button {{391:3}}> Sequence Command A HVAC ModeHVAC Mode1 Byte20.102 HVAC modeCRT
15<Button {{391:3}}> Sequence Command A 0-255-Toggle0-2551 Byte5.10 counter pulses (0..255)CRT
15<Button {{391:3}}> Sequence Command A 0-100%-Toggle0-100%1 Byte5.1 percentage (0..100%)CRT
15<Button {{391:3}}> Sequence Command A HVAC Mode-ToggleHVAC Mode1 Byte20.102 HVAC modeCRT
15<Button {{391:3}}> Press ActionOff/On1 Bit1.1 switchCRWT
15<Button {{391:3}}> Press - Release ActionOff/On1 Bit1.1 switchCRWT
15<Button {{391:3}}> Short PressOff/On1 Bit1.1 switchCRWT
15<Button {{391:3}}> Short - Long PressOff/On1 Bit1.1 switchCRWT
15<Button {{391:3}}> Dimming On/OffOff/On1 Bit1.1 switchCRWT
15<Button {{391:3}}> Object AOff/On1 Bit1.1 switchCRT
15<Button {{391:3}}> Shutter - Up/DownUp/Down1 Bit1.8 up/downCRWT
15<Button {{391:3}}> Sequence Command A Off/OnOff/On1 Bit1.1 switchCRT
15<Button {{391:3}}> Sequence Command A Off/On-ToggleOff/On1 Bit1.1 switchCRT
15<Button {{391:3}}> Make Up RoomOff/On1 Bit1.1 switchCRWT
15<Special Button {{1134:3}}> Enable ObjectDisable/Enable1 Bit1.3 enableCW
16<Button {{391:3}}> Green0-2551 Byte5.10 counter pulses (0..255)CRT
16<Button {{391:3}}> Long Press0-2551 Byte5.10 counter pulses (0..255)CRT
16<Button {{391:3}}> Long Press0-100%1 Byte5.1 percentage (0..100%)CRT
16<Button {{391:3}}> Long PressHVAC Mode1 Byte20.102 HVAC modeCRT
16<Button {{391:3}}> Release Action0-2551 Byte5.10 counter pulses (0..255)CRT
16<Button {{391:3}}> Release Action0-100%1 Byte5.1 percentage (0..100%)CRT
16<Button {{391:3}}> Release ActionHVAC Mode1 Byte20.102 HVAC modeCRT
16<Button {{391:3}}> Sequence Command B 0-2550-2551 Byte5.10 counter pulses (0..255)CRT
16<Button {{391:3}}> Sequence Command B 0-100%0-100%1 Byte5.1 percentage (0..100%)CRT
16<Button {{391:3}}> Sequence Command B HVAC ModeHVAC Mode1 Byte20.102 HVAC modeCRT
16<Button {{391:3}}> Sequence Command B 0-255-Toggle0-2551 Byte5.10 counter pulses (0..255)CRT
16<Button {{391:3}}> Sequence Command B 0-100%-Toggle0-100%1 Byte5.1 percentage (0..100%)CRT
16<Button {{391:3}}> Sequence Command B HVAC Mode-ToggleHVAC Mode1 Byte20.102 HVAC modeCRT
16<Button {{391:3}}> Loop Value OutputLoop Value Output1 Byte5.10 counter pulses (0..255)CRT
16<Button {{391:3}}> Dimming ControlBrighter/Darker4 Bit3.7 dimming controlCRT
16<Button {{391:3}}> Long PressOff/On1 Bit1.1 switchCRWT
16<Button {{391:3}}> Release ActionOff/On1 Bit1.1 switchCRWT
16<Button {{391:3}}> Object BOff/On1 Bit1.1 switchCRT
16<Button {{391:3}}> Shutter - Step/StopStep/Stop1 Bit1.7 stepCRT
16<Button {{391:3}}> Sequence Command B Off/OnOff/On1 Bit1.1 switchCRT
16<Button {{391:3}}> Sequence Command B Off/On-ToggleOff/On1 Bit1.1 switchCRT
16<Button {{391:3}}> Send Learn Scene TriggerDisable/Enable1 Bit1.3 enableCW
16<Button {{391:3}}> Do Not DisturbOff/On1 Bit1.1 switchCRWT
17<Button {{391:3}}> Additional Object RGB3 Bytes3 Bytes232.600 RGB value 3x(0..255)CRT
17<Button {{391:3}}> Blue0-2551 Byte5.10 counter pulses (0..255)CRT
17<Button {{391:3}}> Sequence Command C 0-2550-2551 Byte5.10 counter pulses (0..255)CRT
17<Button {{391:3}}> Sequence Command C 0-100%0-100%1 Byte5.1 percentage (0..100%)CRT
17<Button {{391:3}}> Sequence Command C HVAC ModeHVAC Mode1 Byte20.102 HVAC modeCRT
17<Button {{391:3}}> Sequence Command C 0-255-Toggle0-2551 Byte5.10 counter pulses (0..255)CRT
17<Button {{391:3}}> Sequence Command C 0-100%-Toggle0-100%1 Byte5.1 percentage (0..100%)CRT
17<Button {{391:3}}> Sequence Command C HVAC Mode-ToggleHVAC Mode1 Byte20.102 HVAC modeCRT
17<Button {{391:3}}> Loop Value FeedbackLoop Value Feedback1 Byte5.10 counter pulses (0..255)CW
17<Button {{391:3}}> Sequence Command C Off/OnOff/On1 Bit1.1 switchCRT
17<Button {{391:3}}> Sequence Command C Off/On-ToggleOff/On1 Bit1.1 switchCRT
17<Button {{391:3}}> FeedbackOff/On1 Bit1.1 switchCW
17<Button {{391:3}}> FeedbackUp/Down1 Bit1.8 up/downCW
17<Button {{391:3}}> Object COff/On1 Bit1.1 switchCRT
18<Button {{391:3}}> Enable InputDisable/Enable1 Bit1.3 enableCW
19<Button {{556:4}}> RGB3 Bytes3 Bytes232.600 RGB value 3x(0..255)CRT
19<Button {{556:4}}> Red0-2551 Byte5.10 counter pulses (0..255)CRT
19<Button {{556:4}}> Press Action0-2551 Byte5.10 counter pulses (0..255)CRT
19<Button {{556:4}}> Press Action0-100%1 Byte5.1 percentage (0..100%)CRT
19<Button {{556:4}}> Press ActionHVAC Mode1 Byte20.102 HVAC modeCRT
19<Button {{556:4}}> Press - Release Action0-2551 Byte5.10 counter pulses (0..255)CRT
19<Button {{556:4}}> Press - Release Action0-100%1 Byte5.1 percentage (0..100%)CRT
19<Button {{556:4}}> Press - Release ActionHVAC Mode1 Byte20.102 HVAC modeCRT
19<Button {{556:4}}> Short Press0-2551 Byte5.10 counter pulses (0..255)CRT
19<Button {{556:4}}> Short Press0-100%1 Byte5.1 percentage (0..100%)CRT
19<Button {{556:4}}> Short PressHVAC Mode1 Byte20.102 HVAC modeCRT
19<Button {{556:4}}> Short - Long Press0-2551 Byte5.10 counter pulses (0..255)CRT
19<Button {{556:4}}> Short - Long Press0-100%1 Byte5.1 percentage (0..100%)CRT
19<Button {{556:4}}> Short - Long PressHVAC Mode1 Byte20.102 HVAC modeCRT
19<Button {{556:4}}> Recall/Learn SceneScene1 Byte18.1 scene controlCRT
19<Button {{556:4}}> Sequence Command A 0-2550-2551 Byte5.10 counter pulses (0..255)CRT
19<Button {{556:4}}> Sequence Command A 0-100%0-100%1 Byte5.1 percentage (0..100%)CRT
19<Button {{556:4}}> Sequence Command A HVAC ModeHVAC Mode1 Byte20.102 HVAC modeCRT
19<Button {{556:4}}> Sequence Command A 0-255-Toggle0-2551 Byte5.10 counter pulses (0..255)CRT
19<Button {{556:4}}> Sequence Command A 0-100%-Toggle0-100%1 Byte5.1 percentage (0..100%)CRT
19<Button {{556:4}}> Sequence Command A HVAC Mode-ToggleHVAC Mode1 Byte20.102 HVAC modeCRT
19<Button {{556:4}}> Press ActionOff/On1 Bit1.1 switchCRWT
19<Button {{556:4}}> Press - Release ActionOff/On1 Bit1.1 switchCRWT
19<Button {{556:4}}> Short PressOff/On1 Bit1.1 switchCRWT
19<Button {{556:4}}> Short - Long PressOff/On1 Bit1.1 switchCRWT
19<Button {{556:4}}> Dimming On/OffOff/On1 Bit1.1 switchCRWT
19<Button {{556:4}}> Object AOff/On1 Bit1.1 switchCRT
19<Button {{556:4}}> Shutter - Up/DownUp/Down1 Bit1.8 up/downCRWT
19<Button {{556:4}}> Sequence Command A Off/OnOff/On1 Bit1.1 switchCRT
19<Button {{556:4}}> Sequence Command A Off/On-ToggleOff/On1 Bit1.1 switchCRT
19<Button {{556:4}}> Make Up RoomOff/On1 Bit1.1 switchCRWT
19<Special Button {{1176:4}}> Enable ObjectDisable/Enable1 Bit1.3 enableCW
20<Button {{556:4}}> Green0-2551 Byte5.10 counter pulses (0..255)CRT
20<Button {{556:4}}> Long Press0-2551 Byte5.10 counter pulses (0..255)CRT
20<Button {{556:4}}> Long Press0-100%1 Byte5.1 percentage (0..100%)CRT
20<Button {{556:4}}> Long PressHVAC Mode1 Byte20.102 HVAC modeCRT
20<Button {{556:4}}> Release Action0-2551 Byte5.10 counter pulses (0..255)CRT
20<Button {{556:4}}> Release Action0-100%1 Byte5.1 percentage (0..100%)CRT
20<Button {{556:4}}> Release ActionHVAC Mode1 Byte20.102 HVAC modeCRT
20<Button {{556:4}}> Sequence Command B 0-2550-2551 Byte5.10 counter pulses (0..255)CRT
20<Button {{556:4}}> Sequence Command B 0-100%0-100%1 Byte5.1 percentage (0..100%)CRT
20<Button {{556:4}}> Sequence Command B HVAC ModeHVAC Mode1 Byte20.102 HVAC modeCRT
20<Button {{556:4}}> Sequence Command B 0-255-Toggle0-2551 Byte5.10 counter pulses (0..255)CRT
20<Button {{556:4}}> Sequence Command B 0-100%-Toggle0-100%1 Byte5.1 percentage (0..100%)CRT
20<Button {{556:4}}> Sequence Command B HVAC Mode-ToggleHVAC Mode1 Byte20.102 HVAC modeCRT
20<Button {{556:4}}> Loop Value OutputLoop Value Output1 Byte5.10 counter pulses (0..255)CRT
20<Button {{556:4}}> Dimming ControlBrighter/Darker4 Bit3.7 dimming controlCRT
20<Button {{556:4}}> Long PressOff/On1 Bit1.1 switchCRWT
20<Button {{556:4}}> Release ActionOff/On1 Bit1.1 switchCRWT
20<Button {{556:4}}> Object BOff/On1 Bit1.1 switchCRT
20<Button {{556:4}}> Shutter - Step/StopStep/Stop1 Bit1.7 stepCRT
20<Button {{556:4}}> Sequence Command B Off/OnOff/On1 Bit1.1 switchCRT
20<Button {{556:4}}> Sequence Command B Off/On-ToggleOff/On1 Bit1.1 switchCRT
20<Button {{556:4}}> Send Learn Scene TriggerDisable/Enable1 Bit1.3 enableCW
20<Button {{556:4}}> Do Not DisturbOff/On1 Bit1.1 switchCRWT
21<Button {{556:4}}> Additional Object RGB3 Bytes3 Bytes232.600 RGB value 3x(0..255)CRT
21<Button {{556:4}}> Blue0-2551 Byte5.10 counter pulses (0..255)CRT
21<Button {{556:4}}> Sequence Command C 0-2550-2551 Byte5.10 counter pulses (0..255)CRT
21<Button {{556:4}}> Sequence Command C 0-100%0-100%1 Byte5.1 percentage (0..100%)CRT
21<Button {{556:4}}> Sequence Command C HVAC ModeHVAC Mode1 Byte20.102 HVAC modeCRT
21<Button {{556:4}}> Sequence Command C 0-255-Toggle0-2551 Byte5.10 counter pulses (0..255)CRT
21<Button {{556:4}}> Sequence Command C 0-100%-Toggle0-100%1 Byte5.1 percentage (0..100%)CRT
21<Button {{556:4}}> Sequence Command C HVAC Mode-ToggleHVAC Mode1 Byte20.102 HVAC modeCRT
21<Button {{556:4}}> Loop Value FeedbackLoop Value Feedback1 Byte5.10 counter pulses (0..255)CW
21<Button {{556:4}}> Sequence Command C Off/OnOff/On1 Bit1.1 switchCRT
21<Button {{556:4}}> Sequence Command C Off/On-ToggleOff/On1 Bit1.1 switchCRT
21<Button {{556:4}}> FeedbackOff/On1 Bit1.1 switchCW
21<Button {{556:4}}> FeedbackUp/Down1 Bit1.8 up/downCW
21<Button {{556:4}}> Object COff/On1 Bit1.1 switchCRT
22<Button {{556:4}}> Enable InputDisable/Enable1 Bit1.3 enableCW
23<Button {{721:5}}> RGB3 Bytes3 Bytes232.600 RGB value 3x(0..255)CRT
23<Button {{721:5}}> Red0-2551 Byte5.10 counter pulses (0..255)CRT
23<Button {{721:5}}> Press Action0-2551 Byte5.10 counter pulses (0..255)CRT
23<Button {{721:5}}> Press Action0-100%1 Byte5.1 percentage (0..100%)CRT
23<Button {{721:5}}> Press ActionHVAC Mode1 Byte20.102 HVAC modeCRT
23<Button {{721:5}}> Press - Release Action0-2551 Byte5.10 counter pulses (0..255)CRT
23<Button {{721:5}}> Press - Release Action0-100%1 Byte5.1 percentage (0..100%)CRT
23<Button {{721:5}}> Press - Release ActionHVAC Mode1 Byte20.102 HVAC modeCRT
23<Button {{721:5}}> Short Press0-2551 Byte5.10 counter pulses (0..255)CRT
23<Button {{721:5}}> Short Press0-100%1 Byte5.1 percentage (0..100%)CRT
23<Button {{721:5}}> Short PressHVAC Mode1 Byte20.102 HVAC modeCRT
23<Button {{721:5}}> Short - Long Press0-2551 Byte5.10 counter pulses (0..255)CRT
23<Button {{721:5}}> Short - Long Press0-100%1 Byte5.1 percentage (0..100%)CRT
23<Button {{721:5}}> Short - Long PressHVAC Mode1 Byte20.102 HVAC modeCRT
23<Button {{721:5}}> Recall/Learn SceneScene1 Byte18.1 scene controlCRT
23<Button {{721:5}}> Sequence Command A 0-2550-2551 Byte5.10 counter pulses (0..255)CRT
23<Button {{721:5}}> Sequence Command A 0-100%0-100%1 Byte5.1 percentage (0..100%)CRT
23<Button {{721:5}}> Sequence Command A HVAC ModeHVAC Mode1 Byte20.102 HVAC modeCRT
23<Button {{721:5}}> Sequence Command A 0-255-Toggle0-2551 Byte5.10 counter pulses (0..255)CRT
23<Button {{721:5}}> Sequence Command A 0-100%-Toggle0-100%1 Byte5.1 percentage (0..100%)CRT
23<Button {{721:5}}> Sequence Command A HVAC Mode-ToggleHVAC Mode1 Byte20.102 HVAC modeCRT
23<Button {{721:5}}> Press ActionOff/On1 Bit1.1 switchCRWT
23<Button {{721:5}}> Press - Release ActionOff/On1 Bit1.1 switchCRWT
23<Button {{721:5}}> Short PressOff/On1 Bit1.1 switchCRWT
23<Button {{721:5}}> Short - Long PressOff/On1 Bit1.1 switchCRWT
23<Button {{721:5}}> Dimming On/OffOff/On1 Bit1.1 switchCRWT
23<Button {{721:5}}> Object AOff/On1 Bit1.1 switchCRT
23<Button {{721:5}}> Shutter - Up/DownUp/Down1 Bit1.8 up/downCRWT
23<Button {{721:5}}> Sequence Command A Off/OnOff/On1 Bit1.1 switchCRT
23<Button {{721:5}}> Sequence Command A Off/On-ToggleOff/On1 Bit1.1 switchCRT
23<Button {{721:5}}> Make Up RoomOff/On1 Bit1.1 switchCRWT
23<Special Button {{1218:5}}> Enable ObjectDisable/Enable1 Bit1.3 enableCW
24<Button {{721:5}}> Green0-2551 Byte5.10 counter pulses (0..255)CRT
24<Button {{721:5}}> Long Press0-2551 Byte5.10 counter pulses (0..255)CRT
24<Button {{721:5}}> Long Press0-100%1 Byte5.1 percentage (0..100%)CRT
24<Button {{721:5}}> Long PressHVAC Mode1 Byte20.102 HVAC modeCRT
24<Button {{721:5}}> Release Action0-2551 Byte5.10 counter pulses (0..255)CRT
24<Button {{721:5}}> Release Action0-100%1 Byte5.1 percentage (0..100%)CRT
24<Button {{721:5}}> Release ActionHVAC Mode1 Byte20.102 HVAC modeCRT
24<Button {{721:5}}> Sequence Command B 0-2550-2551 Byte5.10 counter pulses (0..255)CRT
24<Button {{721:5}}> Sequence Command B 0-100%0-100%1 Byte5.1 percentage (0..100%)CRT
24<Button {{721:5}}> Sequence Command B HVAC ModeHVAC Mode1 Byte20.102 HVAC modeCRT
24<Button {{721:5}}> Sequence Command B 0-255-Toggle0-2551 Byte5.10 counter pulses (0..255)CRT
24<Button {{721:5}}> Sequence Command B 0-100%-Toggle0-100%1 Byte5.1 percentage (0..100%)CRT
24<Button {{721:5}}> Sequence Command B HVAC Mode-ToggleHVAC Mode1 Byte20.102 HVAC modeCRT
24<Button {{721:5}}> Loop Value OutputLoop Value Output1 Byte5.10 counter pulses (0..255)CRT
24<Button {{721:5}}> Dimming ControlBrighter/Darker4 Bit3.7 dimming controlCRT
24<Button {{721:5}}> Long PressOff/On1 Bit1.1 switchCRWT
24<Button {{721:5}}> Release ActionOff/On1 Bit1.1 switchCRWT
24<Button {{721:5}}> Object BOff/On1 Bit1.1 switchCRT
24<Button {{721:5}}> Shutter - Step/StopStep/Stop1 Bit1.7 stepCRT
24<Button {{721:5}}> Sequence Command B Off/OnOff/On1 Bit1.1 switchCRT
24<Button {{721:5}}> Sequence Command B Off/On-ToggleOff/On1 Bit1.1 switchCRT
24<Button {{721:5}}> Send Learn Scene TriggerDisable/Enable1 Bit1.3 enableCW
24<Button {{721:5}}> Do Not DisturbOff/On1 Bit1.1 switchCRWT
25<Button {{721:5}}> Additional Object RGB3 Bytes3 Bytes232.600 RGB value 3x(0..255)CRT
25<Button {{721:5}}> Blue0-2551 Byte5.10 counter pulses (0..255)CRT
25<Button {{721:5}}> Sequence Command C 0-2550-2551 Byte5.10 counter pulses (0..255)CRT
25<Button {{721:5}}> Sequence Command C 0-100%0-100%1 Byte5.1 percentage (0..100%)CRT
25<Button {{721:5}}> Sequence Command C HVAC ModeHVAC Mode1 Byte20.102 HVAC modeCRT
25<Button {{721:5}}> Sequence Command C 0-255-Toggle0-2551 Byte5.10 counter pulses (0..255)CRT
25<Button {{721:5}}> Sequence Command C 0-100%-Toggle0-100%1 Byte5.1 percentage (0..100%)CRT
25<Button {{721:5}}> Sequence Command C HVAC Mode-ToggleHVAC Mode1 Byte20.102 HVAC modeCRT
25<Button {{721:5}}> Loop Value FeedbackLoop Value Feedback1 Byte5.10 counter pulses (0..255)CW
25<Button {{721:5}}> Sequence Command C Off/OnOff/On1 Bit1.1 switchCRT
25<Button {{721:5}}> Sequence Command C Off/On-ToggleOff/On1 Bit1.1 switchCRT
25<Button {{721:5}}> FeedbackOff/On1 Bit1.1 switchCW
25<Button {{721:5}}> FeedbackUp/Down1 Bit1.8 up/downCW
25<Button {{721:5}}> Object COff/On1 Bit1.1 switchCRT
26<Button {{721:5}}> Enable InputDisable/Enable1 Bit1.3 enableCW
27<Button {{886:6}}> RGB3 Bytes3 Bytes232.600 RGB value 3x(0..255)CRT
27<Button {{886:6}}> Red0-2551 Byte5.10 counter pulses (0..255)CRT
27<Button {{886:6}}> Press Action0-2551 Byte5.10 counter pulses (0..255)CRT
27<Button {{886:6}}> Press Action0-100%1 Byte5.1 percentage (0..100%)CRT
27<Button {{886:6}}> Press ActionHVAC Mode1 Byte20.102 HVAC modeCRT
27<Button {{886:6}}> Press - Release Action0-2551 Byte5.10 counter pulses (0..255)CRT
27<Button {{886:6}}> Press - Release Action0-100%1 Byte5.1 percentage (0..100%)CRT
27<Button {{886:6}}> Press - Release ActionHVAC Mode1 Byte20.102 HVAC modeCRT
27<Button {{886:6}}> Short Press0-2551 Byte5.10 counter pulses (0..255)CRT
27<Button {{886:6}}> Short Press0-100%1 Byte5.1 percentage (0..100%)CRT
27<Button {{886:6}}> Short PressHVAC Mode1 Byte20.102 HVAC modeCRT
27<Button {{886:6}}> Short - Long Press0-2551 Byte5.10 counter pulses (0..255)CRT
27<Button {{886:6}}> Short - Long Press0-100%1 Byte5.1 percentage (0..100%)CRT
27<Button {{886:6}}> Short - Long PressHVAC Mode1 Byte20.102 HVAC modeCRT
27<Button {{886:6}}> Recall/Learn SceneScene1 Byte18.1 scene controlCRT
27<Button {{886:6}}> Sequence Command A 0-2550-2551 Byte5.10 counter pulses (0..255)CRT
27<Button {{886:6}}> Sequence Command A 0-100%0-100%1 Byte5.1 percentage (0..100%)CRT
27<Button {{886:6}}> Sequence Command A HVAC ModeHVAC Mode1 Byte20.102 HVAC modeCRT
27<Button {{886:6}}> Sequence Command A 0-255-Toggle0-2551 Byte5.10 counter pulses (0..255)CRT
27<Button {{886:6}}> Sequence Command A 0-100%-Toggle0-100%1 Byte5.1 percentage (0..100%)CRT
27<Button {{886:6}}> Sequence Command A HVAC Mode-ToggleHVAC Mode1 Byte20.102 HVAC modeCRT
27<Button {{886:6}}> Press ActionOff/On1 Bit1.1 switchCRWT
27<Button {{886:6}}> Press - Release ActionOff/On1 Bit1.1 switchCRWT
27<Button {{886:6}}> Short PressOff/On1 Bit1.1 switchCRWT
27<Button {{886:6}}> Short - Long PressOff/On1 Bit1.1 switchCRWT
27<Button {{886:6}}> Dimming On/OffOff/On1 Bit1.1 switchCRWT
27<Button {{886:6}}> Object AOff/On1 Bit1.1 switchCRT
27<Button {{886:6}}> Shutter - Up/DownUp/Down1 Bit1.8 up/downCRWT
27<Button {{886:6}}> Sequence Command A Off/OnOff/On1 Bit1.1 switchCRT
27<Button {{886:6}}> Sequence Command A Off/On-ToggleOff/On1 Bit1.1 switchCRT
27<Button {{886:6}}> Make Up RoomOff/On1 Bit1.1 switchCRWT
27<Special Button {{1260:6}}> Enable ObjectDisable/Enable1 Bit1.3 enableCW
28<Button {{886:6}}> Green0-2551 Byte5.10 counter pulses (0..255)CRT
28<Button {{886:6}}> Long Press0-2551 Byte5.10 counter pulses (0..255)CRT
28<Button {{886:6}}> Long Press0-100%1 Byte5.1 percentage (0..100%)CRT
28<Button {{886:6}}> Long PressHVAC Mode1 Byte20.102 HVAC modeCRT
28<Button {{886:6}}> Release Action0-2551 Byte5.10 counter pulses (0..255)CRT
28<Button {{886:6}}> Release Action0-100%1 Byte5.1 percentage (0..100%)CRT
28<Button {{886:6}}> Release ActionHVAC Mode1 Byte20.102 HVAC modeCRT
28<Button {{886:6}}> Sequence Command B 0-2550-2551 Byte5.10 counter pulses (0..255)CRT
28<Button {{886:6}}> Sequence Command B 0-100%0-100%1 Byte5.1 percentage (0..100%)CRT
28<Button {{886:6}}> Sequence Command B HVAC ModeHVAC Mode1 Byte20.102 HVAC modeCRT
28<Button {{886:6}}> Sequence Command B 0-255-Toggle0-2551 Byte5.10 counter pulses (0..255)CRT
28<Button {{886:6}}> Sequence Command B 0-100%-Toggle0-100%1 Byte5.1 percentage (0..100%)CRT
28<Button {{886:6}}> Sequence Command B HVAC Mode-ToggleHVAC Mode1 Byte20.102 HVAC modeCRT
28<Button {{886:6}}> Loop Value OutputLoop Value Output1 Byte5.10 counter pulses (0..255)CRT
28<Button {{886:6}}> Dimming ControlBrighter/Darker4 Bit3.7 dimming controlCRT
28<Button {{886:6}}> Long PressOff/On1 Bit1.1 switchCRWT
28<Button {{886:6}}> Release ActionOff/On1 Bit1.1 switchCRWT
28<Button {{886:6}}> Object BOff/On1 Bit1.1 switchCRT
28<Button {{886:6}}> Shutter - Step/StopStep/Stop1 Bit1.7 stepCRT
28<Button {{886:6}}> Sequence Command B Off/OnOff/On1 Bit1.1 switchCRT
28<Button {{886:6}}> Sequence Command B Off/On-ToggleOff/On1 Bit1.1 switchCRT
28<Button {{886:6}}> Send Learn Scene TriggerDisable/Enable1 Bit1.3 enableCW
28<Button {{886:6}}> Do Not DisturbOff/On1 Bit1.1 switchCRWT
29<Button {{886:6}}> Additional Object RGB3 Bytes3 Bytes232.600 RGB value 3x(0..255)CRT
29<Button {{886:6}}> Blue0-2551 Byte5.10 counter pulses (0..255)CRT
29<Button {{886:6}}> Sequence Command C 0-2550-2551 Byte5.10 counter pulses (0..255)CRT
29<Button {{886:6}}> Sequence Command C 0-100%0-100%1 Byte5.1 percentage (0..100%)CRT
29<Button {{886:6}}> Sequence Command C HVAC ModeHVAC Mode1 Byte20.102 HVAC modeCRT
29<Button {{886:6}}> Sequence Command C 0-255-Toggle0-2551 Byte5.10 counter pulses (0..255)CRT
29<Button {{886:6}}> Sequence Command C 0-100%-Toggle0-100%1 Byte5.1 percentage (0..100%)CRT
29<Button {{886:6}}> Sequence Command C HVAC Mode-ToggleHVAC Mode1 Byte20.102 HVAC modeCRT
29<Button {{886:6}}> Loop Value FeedbackLoop Value Feedback1 Byte5.10 counter pulses (0..255)CW
29<Button {{886:6}}> Sequence Command C Off/OnOff/On1 Bit1.1 switchCRT
29<Button {{886:6}}> Sequence Command C Off/On-ToggleOff/On1 Bit1.1 switchCRT
29<Button {{886:6}}> FeedbackOff/On1 Bit1.1 switchCW
29<Button {{886:6}}> FeedbackUp/Down1 Bit1.8 up/downCW
29<Button {{886:6}}> Object COff/On1 Bit1.1 switchCRT
30<Button {{886:6}}> Enable InputDisable/Enable1 Bit1.3 enableCW
31<Rear Input> RGB3 Bytes3 Bytes232.600 RGB value 3x(0..255)CRT
31<Rear Input> Red0-2551 Byte5.10 counter pulses (0..255)CRT
31<Rear Input> Closure Action0-2551 Byte5.10 counter pulses (0..255)CRT
31<Rear Input> Opening Action0-2551 Byte5.10 counter pulses (0..255)CRT
31<Rear Input> Closure Action0-100%1 Byte5.1 percentage (0..100%)CRT
31<Rear Input> Opening Action0-100%1 Byte5.1 percentage (0..100%)CRT
31<Rear Input> Closure ActionHVAC Mode1 Byte20.102 HVAC modeCRT
31<Rear Input> Opening ActionHVAC Mode1 Byte20.102 HVAC modeCRT
31<Rear Input> Closure - Opening Action0-2551 Byte5.10 counter pulses (0..255)CRT
31<Rear Input> Closure - Opening Action0-100%1 Byte5.1 percentage (0..100%)CRT
31<Rear Input> Closure - Opening ActionHVAC Mode1 Byte20.102 HVAC modeCRT
31<Rear Input> Short Closure0-2551 Byte5.10 counter pulses (0..255)CRT
31<Rear Input> Short Closure0-100%1 Byte5.1 percentage (0..100%)CRT
31<Rear Input> Short ClosureHVAC Mode1 Byte20.102 HVAC modeCRT
31<Rear Input> Short - Long Closure0-2551 Byte5.10 counter pulses (0..255)CRT
31<Rear Input> Short - Long Closure0-100%1 Byte5.1 percentage (0..100%)CRT
31<Rear Input> Short - Long ClosureHVAC Mode1 Byte20.102 HVAC modeCRT
31<Rear Input> Recall/Learn SceneScene1 Byte18.1 scene controlCRT
31<Rear Input> Sequence Command A 0-2550-2551 Byte5.10 counter pulses (0..255)CRT
31<Rear Input> Sequence Command A 0-100%0-100%1 Byte5.1 percentage (0..100%)CRT
31<Rear Input> Sequence Command A HVAC ModeHVAC Mode1 Byte20.102 HVAC modeCRT
31<Rear Input> Sequence Command A 0-255-Toggle0-2551 Byte5.10 counter pulses (0..255)CRT
31<Rear Input> Sequence Command A 0-100%-Toggle0-100%1 Byte5.1 percentage (0..100%)CRT
31<Rear Input> Sequence Command A HVAC Mode-ToggleHVAC Mode1 Byte20.102 HVAC modeCRT
31<Rear Input> Closure ActionOff/On1 Bit1.1 switchCRWT
31<Rear Input> Opening ActionOff/On1 Bit1.1 switchCRWT
31<Rear Input> Closure - Opening ActionOff/On1 Bit1.1 switchCRWT
31<Rear Input> Short ClosureOff/On1 Bit1.1 switchCRWT
31<Rear Input> Short - Long ClosureOff/On1 Bit1.1 switchCRWT
31<Rear Input> Dimming On/OffOff/On1 Bit1.1 switchCRWT
31<Rear Input> Object AOff/On1 Bit1.1 switchCRT
31<Rear Input> Shutter - Up/DownUp/Down1 Bit1.8 up/downCRWT
31<Rear Input> Sequence Command A Off/OnOff/On1 Bit1.1 switchCRT
31<Rear Input> Sequence Command A Off/On-ToggleOff/On1 Bit1.1 switchCRT
31<Rear Input> Make Up RoomOff/On1 Bit1.1 switchCRWT
32<Rear Input> Green0-2551 Byte5.10 counter pulses (0..255)CRT
32<Rear Input> Long Closure0-2551 Byte5.10 counter pulses (0..255)CRT
32<Rear Input> Long Closure0-100%1 Byte5.1 percentage (0..100%)CRT
32<Rear Input> Long ClosureHVAC Mode1 Byte20.102 HVAC modeCRT
32<Rear Input> Opening Action0-2551 Byte5.10 counter pulses (0..255)CRT
32<Rear Input> Opening Action0-100%1 Byte5.1 percentage (0..100%)CRT
32<Rear Input> Opening ActionHVAC Mode1 Byte20.102 HVAC modeCRT
32<Rear Input> Sequence Command B 0-2550-2551 Byte5.10 counter pulses (0..255)CRT
32<Rear Input> Sequence Command B 0-100%0-100%1 Byte5.1 percentage (0..100%)CRT
32<Rear Input> Sequence Command B HVAC ModeHVAC Mode1 Byte20.102 HVAC modeCRT
32<Rear Input> Sequence Command B 0-255-Toggle0-2551 Byte5.10 counter pulses (0..255)CRT
32<Rear Input> Sequence Command B 0-100%-Toggle0-100%1 Byte5.1 percentage (0..100%)CRT
32<Rear Input> Sequence Command B HVAC Mode-ToggleHVAC Mode1 Byte20.102 HVAC modeCRT
32<Rear Input> Loop Value OutputLoop Value Output1 Byte5.10 counter pulses (0..255)CRT
32<Rear Input> Dimming ControlBrighter/Darker4 Bit3.7 dimming controlCRT
32<Rear Input> Long ClosureOff/On1 Bit1.1 switchCRWT
32<Rear Input> Opening ActionOff/On1 Bit1.1 switchCRWT
32<Rear Input> Object BOff/On1 Bit1.1 switchCRT
32<Rear Input> Shutter - Step/StopStep/Stop1 Bit1.7 stepCRT
32<Rear Input> Sequence Command B Off/OnOff/On1 Bit1.1 switchCRT
32<Rear Input> Sequence Command B Off/On-ToggleOff/On1 Bit1.1 switchCRT
32<Rear Input> Send Learn Scene TriggerDisable/Enable1 Bit1.3 enableCW
32<Rear Input> Do Not DisturbOff/On1 Bit1.1 switchCRWT
33<Rear Input> Additional Object RGB3 Bytes3 Bytes232.600 RGB value 3x(0..255)CRT
33<Rear Input> Blue0-2551 Byte5.10 counter pulses (0..255)CRT
33<Rear Input> Sequence Command C 0-2550-2551 Byte5.10 counter pulses (0..255)CRT
33<Rear Input> Sequence Command C 0-100%0-100%1 Byte5.1 percentage (0..100%)CRT
33<Rear Input> Sequence Command C HVAC ModeHVAC Mode1 Byte20.102 HVAC modeCRT
33<Rear Input> Sequence Command C 0-255-Toggle0-2551 Byte5.10 counter pulses (0..255)CRT
33<Rear Input> Sequence Command C 0-100%-Toggle0-100%1 Byte5.1 percentage (0..100%)CRT
33<Rear Input> Sequence Command C HVAC Mode-ToggleHVAC Mode1 Byte20.102 HVAC modeCRT
33<Rear Input> Loop Value FeedbackLoop Value Feedback1 Byte5.10 counter pulses (0..255)CW
33<Rear Input> Sequence Command C Off/OnOff/On1 Bit1.1 switchCRT
33<Rear Input> Sequence Command C Off/On-ToggleOff/On1 Bit1.1 switchCRT
33<Rear Input> FeedbackOff/On1 Bit1.1 switchCW
33<Rear Input> FeedbackUp/Down1 Bit1.8 up/downCW
33<Rear Input> Object COff/On1 Bit1.1 switchCRT
34<Rear Input> Enable InputDisable/Enable1 Bit1.3 enableCW
35<LED 1> CommandOff/On1 Bit1.1 switchCW
36<LED 2> CommandOff/On1 Bit1.1 switchCW
37<LED 3> CommandOff/On1 Bit1.1 switchCW
38<LED 4> CommandOff/On1 Bit1.1 switchCW
39<LED 5> CommandOff/On1 Bit1.1 switchCW
40<LED 6> CommandOff/On1 Bit1.1 switchCW
43<RGB> Physical Dimension4 Bytes Signed4 Bytes13.1 counter pulses (signed)CW
43<RGB> Physical Dimension4 Bytes Unsigned4 Bytes12.1 counter pulses (unsigned)CW
43<RGB> Physical Dimension4 Bytes Float4 BytesDPT.14CW
43<RGB> Physical DimensionPower4 Bytes14.56 power (W)CW
43<RGB> Physical DimensionEnergy4 Bytes13.13 active energy (kWh)CW
43<RGB> Physical Dimension2 Bytes Signed2 Bytes8.1 pulses differenceCW
43<RGB> Physical Dimension2 Bytes Unsigned2 Bytes7.1 pulsesCW
43<RGB> Physical Dimension2 Bytes Float2 BytesDPT.9CW
43<RGB> Physical DimensionTemperature2 Bytes9.1 temperature (°C)CW
43<RGB> Physical DimensionHumidity %2 Bytes9.7 humidity (%)CW
43<RGB> Physical DimensionValue ppm2 Bytes9.8 parts/million (ppm)CW
43<RGB> Physical Dimension1 Byte Signed1 Byte6.10 counter pulses (-128..127)CW
43<RGB> Physical Dimension1 Byte Unsigned1 Byte5.10 counter pulses (0..255)CW
43<RGB> Physical Dimension0-100%1 Byte5.1 percentage (0..100%)CW
43<RGB> Off/OnOff/On1 Bit1.1 switchCW
43<RGB> Feedback KNX 1Off/On1 Bit1.1 switchCW
43<RGB> Stop Color LoopStop-Start1 Bit1.1 switchCW
44<RGB> Red Component0-2551 Byte5.10 counter pulses (0..255)CW
44<RGB> Feedback KNX 2Off/On1 Bit1.1 switchCW
45<RGB> Green Component0-2551 Byte5.10 counter pulses (0..255)CW
45<RGB> Feedback KNX 3Off/On1 Bit1.1 switchCW
46<RGB> Blue Component0-2551 Byte5.10 counter pulses (0..255)CW
46<RGB> Feedback KNX 4Off/On1 Bit1.1 switchCW
47<RGB> RGB Component3 Bytes3 Bytes232.600 RGB value 3x(0..255)CW
47<RGB> Feedback KNX 5Off/On1 Bit1.1 switchCW
48<RGB> Brightness0-100%1 Byte5.1 percentage (0..100%)CW
48<RGB> Night ModeOff/On1 Bit1.1 switchCW
49<RGB> Step Light ModeOff/On1 Bit1.1 switchCW
50<Temperature 1> AlarmOff-On1 Bit1.1 switchCRT
51<Temperature 1> Actual TemperatureValue °C2 Bytes9.1 temperature (°C)CRT
52<Temperature 1> KNX Probe TemperatureValue °C2 Bytes9.1 temperature (°C)CW
53<T.Sensor 1> Enable InputDisable/Enable1 Bit1.3 enableCW
53<Thermostat 1> Heat/Cool ModeHeat/Cool1 Bit1.100 heating/coolingCW
53<Thermostat 1> Heat/Cool ModeHeat/Cool1 Bit1.100 heating/coolingCRT
54<T.Sensor 1> Setpoint UpperValue °C2 Bytes9.1 temperature (°C)CW
54<Thermostat 1> Window ContactClose/Open1 Bit1.19 window/doorCW
55<T.Sensor 1> Telegram UpperOff/On1 Bit1.1 switchCRT
55<Thermostat 1> Comfort ModeOff/On1 Bit1.1 switchCW
55<Thermostat 1> Enable CoolingOff/On1 Bit1.1 switchCW
55<Thermostat 1> Enable HeatingOff/On1 Bit1.1 switchCW
55<Thermostat 1> Lock Heat/CoolLock1 Bit1.1 switchCW
56<T.Sensor 1> Setpoint LowerValue °C2 Bytes9.1 temperature (°C)CW
56<Thermostat 1> HVAC ModeComf/Standby/Eco/B.protection1 Byte20.102 HVAC modeCRW
57<Thermostat 1> Actual SetpointValue °C2 Bytes9.1 temperature (°C)CRT
57<T.Sensor 1> Telegram LowerOff/On1 Bit1.1 switchCRT
58<Thermostat 1> Setpoint AdjustmentValue °C2 Bytes9.1 temperature (°C)CW
58<Thermostat 1> Setpoint AdjustmentValue °C1 Bit1.7 stepCW
59<Thermostat 1> Base SetpointValue °C2 Bytes9.1 temperature (°C)CW
59<Thermostat 1> SP Economy HeatingValue °C2 Bytes9.1 temperature (°C)CW
59<Thermostat 1> SP EconomyValue °C2 Bytes9.1 temperature (°C)CW
60<Thermostat 1> SP Standby HeatingValue °C2 Bytes9.1 temperature (°C)CW
60<Thermostat 1> SP StandbyValue °C2 Bytes9.1 temperature (°C)CW
61<Thermostat 1> SP Comfort HeatingValue °C2 Bytes9.1 temperature (°C)CW
61<Thermostat 1> SP ComfortValue °C2 Bytes9.1 temperature (°C)CW
62<Thermostat 1> SP Economy CoolingValue °C2 Bytes9.1 temperature (°C)CW
63<Thermostat 1> SP Standby CoolingValue °C2 Bytes9.1 temperature (°C)CW
64<Thermostat 1> SP Comfort CoolingValue °C2 Bytes9.1 temperature (°C)CW
65<Thermostat 1> Heating0-100%1 Byte5.1 percentage (0..100%)CRT
65<Fan Coil 1> Heating/Cooling Valve0-100%1 Byte5.1 percentage (0..100%)CRT
65<Fan Coil 1> Heating Valve0-100%1 Byte5.1 percentage (0..100%)CRT
65<Thermostat 1> HeatingOff/On1 Bit1.1 switchCRT
65<Fan Coil 1> Heating/Cooling ValveOff/On1 Bit1.1 switchCRT
65<Fan Coil 1> Heating ValveOff/On1 Bit1.1 switchCRT
66<Thermostat 1> Cooling0-100%1 Byte5.1 percentage (0..100%)CRT
66<Fan Coil 1> Cooling Valve0-100%1 Byte5.1 percentage (0..100%)CRT
66<Thermostat 1> CoolingOff/On1 Bit1.1 switchCRT
66<Fan Coil 1> Cooling ValveOff/On1 Bit1.1 switchCRT
67<Thermostat 1> 0-100% 2nd Stage Heating0-100%1 Byte5.1 percentage (0..100%)CRT
67<Thermostat 1> Off/On 2nd Stage HeatingOff/On1 Bit1.1 switchCRT
68<Thermostat 1> 0-100% 2nd Stage Cooling0-100%1 Byte5.1 percentage (0..100%)CRT
68<Thermostat 1> Off/On 2nd Stage CoolingOff/On1 Bit1.1 switchCRT
69<Fan Coil 1> Continuous Control %0-100%1 Byte5.1 percentage (0..100%)CRT
69<Fan Coil 1> Speed 1Off/On1 Bit1.1 switchCRT
70<Fan Coil 1> Speed 2Off/On1 Bit1.1 switchCRT
71<Fan Coil 1> Speed 3Off/On1 Bit1.1 switchCRT
72<Fan Coil 1> Set Man/Auto ModeManual (0) / Auto (1)1 Bit1.1 switchCW
73<Fan Coil 1> Force Speed Control in Man Mode0-100%1 Byte5.1 percentage (0..100%)CW
73<Fan Coil 1> Force Value in Man Mode Speed 1Off/On1 Bit1.1 switchCW
74<Fan Coil 1> Force Value in Man Mode Speed 2Off/On1 Bit1.1 switchCW
75<Fan Coil 1> Force Value in Man Mode Speed 3Off/On1 Bit1.1 switchCW
76<Thermostat 1> OFF ThermostatOff/On1 Bit1.1 switchCRWT
77<Fan Coil 1> Ventilation Off/OnOff/On1 Bit1.1 switchCW
78<Additional Valve 1> Percentage0-100%1 Byte5.1 percentage (0..100%)CRT
78<Additional Valve 1> Valve 6 Ways0-100%1 Byte5.1 percentage (0..100%)CRT
78<Additional Valve 1> PWMOff/On1 Bit1.1 switchCRT
79<Temperature 2> AlarmOff-On1 Bit1.1 switchCRT
80<Temperature 2> Actual TemperatureValue °C2 Bytes9.1 temperature (°C)CRT
81<Temperature 2> KNX Probe TemperatureValue °C2 Bytes9.1 temperature (°C)CW
82<T.Sensor 2> Enable InputDisable/Enable1 Bit1.3 enableCW
82<Thermostat 2> Heat/Cool ModeHeat/Cool1 Bit1.100 heating/coolingCW
82<Thermostat 2> Heat/Cool ModeHeat/Cool1 Bit1.100 heating/coolingCRT
83<T.Sensor 2> Setpoint UpperValue °C2 Bytes9.1 temperature (°C)CW
83<Thermostat 2> Window ContactClose/Open1 Bit1.19 window/doorCW
84<T.Sensor 2> Telegram UpperOff/On1 Bit1.1 switchCRT
84<Thermostat 2> Comfort ModeOff/On1 Bit1.1 switchCW
84<Thermostat 2> Enable CoolingOff/On1 Bit1.1 switchCW
84<Thermostat 2> Enable HeatingOff/On1 Bit1.1 switchCW
84<Thermostat 2> Lock Heat/CoolLock1 Bit1.1 switchCW
85<T.Sensor 2> Setpoint LowerValue °C2 Bytes9.1 temperature (°C)CW
85<Thermostat 2> HVAC ModeComf/Standby/Eco/B.protection1 Byte20.102 HVAC modeCRW
86<Thermostat 2> Actual SetpointValue °C2 Bytes9.1 temperature (°C)CRT
86<T.Sensor 2> Telegram LowerOff/On1 Bit1.1 switchCRT
87<Thermostat 2> Setpoint AdjustmentValue °C2 Bytes9.1 temperature (°C)CW
87<Thermostat 2> Setpoint AdjustmentValue °C1 Bit1.7 stepCW
88<Thermostat 2> Base SetpointValue °C2 Bytes9.1 temperature (°C)CW
88<Thermostat 2> SP Economy HeatingValue °C2 Bytes9.1 temperature (°C)CW
88<Thermostat 2> SP EconomyValue °C2 Bytes9.1 temperature (°C)CW
89<Thermostat 2> SP Standby HeatingValue °C2 Bytes9.1 temperature (°C)CW
89<Thermostat 2> SP StandbyValue °C2 Bytes9.1 temperature (°C)CW
90<Thermostat 2> SP Comfort HeatingValue °C2 Bytes9.1 temperature (°C)CW
90<Thermostat 2> SP ComfortValue °C2 Bytes9.1 temperature (°C)CW
91<Thermostat 2> SP Economy CoolingValue °C2 Bytes9.1 temperature (°C)CW
92<Thermostat 2> SP Standby CoolingValue °C2 Bytes9.1 temperature (°C)CW
93<Thermostat 2> SP Comfort CoolingValue °C2 Bytes9.1 temperature (°C)CW
94<Thermostat 2> Heating0-100%1 Byte5.1 percentage (0..100%)CRT
94<Fan Coil 2> Heating/Cooling Valve0-100%1 Byte5.1 percentage (0..100%)CRT
94<Fan Coil 2> Heating Valve0-100%1 Byte5.1 percentage (0..100%)CRT
94<Thermostat 2> HeatingOff/On1 Bit1.1 switchCRT
94<Fan Coil 2> Heating/Cooling ValveOff/On1 Bit1.1 switchCRT
94<Fan Coil 2> Heating ValveOff/On1 Bit1.1 switchCRT
95<Thermostat 2> Cooling0-100%1 Byte5.1 percentage (0..100%)CRT
95<Fan Coil 2> Cooling Valve0-100%1 Byte5.1 percentage (0..100%)CRT
95<Thermostat 2> CoolingOff/On1 Bit1.1 switchCRT
95<Fan Coil 2> Cooling ValveOff/On1 Bit1.1 switchCRT
96<Thermostat 2> 0-100% 2nd Stage Heating0-100%1 Byte5.1 percentage (0..100%)CRT
96<Thermostat 2> Off/On 2nd Stage HeatingOff/On1 Bit1.1 switchCRT
97<Thermostat 2> 0-100% 2nd Stage Cooling0-100%1 Byte5.1 percentage (0..100%)CRT
97<Thermostat 2> Off/On 2nd Stage CoolingOff/On1 Bit1.1 switchCRT
98<Fan Coil 2> Continuous Control %0-100%1 Byte5.1 percentage (0..100%)CRT
98<Fan Coil 2> Speed 1Off/On1 Bit1.1 switchCRT
99<Fan Coil 2> Speed 2Off/On1 Bit1.1 switchCRT
100<Fan Coil 2> Speed 3Off/On1 Bit1.1 switchCRT
101<Fan Coil 2> Set Man/Auto ModeManual (0) / Auto (1)1 Bit1.1 switchCW
102<Fan Coil 2> Force Speed Control in Man Mode0-100%1 Byte5.1 percentage (0..100%)CW
102<Fan Coil 2> Force Value in Man Mode Speed 1Off/On1 Bit1.1 switchCW
103<Fan Coil 2> Force Value in Man Mode Speed 2Off/On1 Bit1.1 switchCW
104<Fan Coil 2> Force Value in Man Mode Speed 3Off/On1 Bit1.1 switchCW
105<Thermostat 2> OFF ThermostatOff/On1 Bit1.1 switchCRWT
106<Fan Coil 2> Ventilation Off/OnOff/On1 Bit1.1 switchCW
107<Additional Valve 2> Percentage0-100%1 Byte5.1 percentage (0..100%)CRT
107<Additional Valve 2> Valve 6 Ways0-100%1 Byte5.1 percentage (0..100%)CRT
107<Additional Valve 2> PWMOff/On1 Bit1.1 switchCRT
108<Humidistat> EnableDisable/Enable1 Bit1.3 enableCW
109<Humidistat> HumidityHumidity %2 Bytes9.7 humidity (%)CRT
110<Humidistat> Upper threshold OutputOff/On1 Bit1.1 switchCRT
111<Humidistat> Lower threshold OutputOff/On1 Bit1.1 switchCRT
112<Humidistat> Regulation TemperatureValue °C2 Bytes9.1 temperature (°C)CW
113<Humidistat> Dew Point TemperatureValue °C2 Bytes9.1 temperature (°C)CRT
114<Humidistat> Dew Point Value %Value %1 Byte5.1 percentage (0..100%)CRT
114<Humidistat> Dew Point CommandOff/On1 Bit1.1 switchCRT
115<CO2 Sensor> Actual MeasureValue ppm2 Bytes9.8 parts/million (ppm)CRT
116<CO2 Sensor> KNX MeasureValue ppm2 Bytes9.8 parts/million (ppm)CW
117<CO2 Sensor> AlarmNo alarm/Alarm1 Bit1.5 alarmCRT
118<CO2 Sensor> EnableEnable/Disable1 Bit1.3 enableCW
119<CO2 Sensor> Threshold 1Value ppm2 Bytes9.8 parts/million (ppm)CW
120<CO2 Sensor> Threshold 1 ValueOff/On1 Bit1.1 switchCRT
121<CO2 Sensor> Threshold 2Value ppm2 Bytes9.8 parts/million (ppm)CW
122<CO2 Sensor> Threshold 2 ValueOff/On1 Bit1.1 switchCRT
123<CO2 Sensor> Threshold 3Value ppm2 Bytes9.8 parts/million (ppm)CW
124<CO2 Sensor> Threshold 3 Value0-100%1 Byte5.1 percentage (0..100%)CRT
135<Logic {{2114:1}}> Output 4Byte CountOutput 4Byte Count4 Bytes13.1 counter pulses (signed)CRT
135<Logic {{2114:1}}> Output 4Byte UCountOutput 4Byte UCount4 Bytes12.1 counter pulses (unsigned)CRT
135<Logic {{2114:1}}> Output 4Byte FloatOutput 4Byte Float4 Bytes14.56 power (W)CRT
135<Logic {{2114:1}}> Input SurveillanceInput 4Byte Count4 Bytes13.1 counter pulses (signed)CW
135<Logic {{2114:1}}> Input SurveillanceInput 4Byte UCount4 Bytes12.1 counter pulses (unsigned)CW
135<Logic {{2114:1}}> Input SurveillanceInput 4Byte Float4 Bytes14.56 power (W)CW
135<Logic {{2114:1}}> Output 2Byte CountOutput 2Byte Count2 Bytes8.1 pulses differenceCRT
135<Logic {{2114:1}}> Output 2Byte UCountOutput 2Byte UCount2 Bytes7.1 pulsesCRT
135<Logic {{2114:1}}> Output 2Byte FloatOutput 2Byte Float2 Bytes9.1 temperature (°C)CRT
135<Logic {{2114:1}}> Input TemperatureValue °C2 Bytes9.1 temperature (°C)CW
135<Logic {{2114:1}}> Input SurveillanceInput 2Byte Count2 Bytes8.1 pulses differenceCW
135<Logic {{2114:1}}> Input SurveillanceInput 2Byte UCount2 Bytes7.1 pulsesCW
135<Logic {{2114:1}}> Input SurveillanceInput 2Byte Float2 Bytes9.1 temperature (°C)CW
135<Logic {{2114:1}}> Output1 Byte1 Byte5.10 counter pulses (0..255)CRT
135<Logic {{2114:1}}> Output CountOutput Count1 Byte6.10 counter pulses (-128..127)CRT
135<Logic {{2114:1}}> Output UCountOutput UCount1 Byte5.10 counter pulses (0..255)CRT
135<Logic {{2114:1}}> Output Value %Value %1 Byte5.1 percentage (0..100%)CRT
135<Logic {{2114:1}}> Input Value %Value %1 Byte5.1 percentage (0..100%)CW
135<Logic {{2114:1}}> Input SurveillanceInput Count1 Byte6.10 counter pulses (-128..127)CW
135<Logic {{2114:1}}> Input SurveillanceInput UCount1 Byte5.10 counter pulses (0..255)CW
135<Logic {{2114:1}}> Output1 Bit1 Bit1.2 booleanCRT
135<Logic {{2114:1}}> OutputLogic1 Bit1.2 booleanCRT
135<Logic {{2114:1}}> Output BitOutput Bit1 Bit1.2 booleanCRT
135<Logic {{2114:1}}> Input SurveillanceInput Bit1 Bit1.1 switchCW
135<Logic {{2114:1}}> Command for SemiautomaticOff/On1 Bit1.1 switchCW
135<VH> Room BookedRoom Booked1 Bit1.2 booleanCW
136<Logic {{2114:1}}> Input4 Bytes4 Bytes14.56 power (W)CW
136<Logic {{2114:1}}> Input A 4Byte CountInput A 4Byte Count4 Bytes13.1 counter pulses (signed)CW
136<Logic {{2114:1}}> Input A 4Byte UCountInput A 4Byte UCount4 Bytes12.1 counter pulses (unsigned)CW
136<Logic {{2114:1}}> Input A 4Byte FloatInput A 4Byte Float4 Bytes14.56 power (W)CW
136<Logic {{2114:1}}> Input StatusInput 4Byte Count4 Bytes13.1 counter pulses (signed)CW
136<Logic {{2114:1}}> Input StatusInput 4Byte UCount4 Bytes12.1 counter pulses (unsigned)CW
136<Logic {{2114:1}}> Input StatusInput 4Byte Float4 Bytes14.56 power (W)CW
136<Logic {{2114:1}}> Input2 Bytes2 Bytes9.1 temperature (°C)CW
136<Logic {{2114:1}}> Input A 2Byte CountInput A 2Byte Count2 Bytes8.1 pulses differenceCW
136<Logic {{2114:1}}> Input A 2Byte UCountInput A 2Byte UCount2 Bytes7.1 pulsesCW
136<Logic {{2114:1}}> Input A 2Byte FloatInput A 2Byte Float2 Bytes9.1 temperature (°C)CW
136<Logic {{2114:1}}> Input SetpointValue °C2 Bytes9.1 temperature (°C)CW
136<Logic {{2114:1}}> Input Relative HumidityHumidity %2 Bytes9.7 humidity (%)CW
136<Logic {{2114:1}}> Input StatusInput 2Byte Count2 Bytes8.1 pulses differenceCW
136<Logic {{2114:1}}> Input StatusInput 2Byte UCount2 Bytes7.1 pulsesCW
136<Logic {{2114:1}}> Input StatusInput 2Byte Float2 Bytes9.1 temperature (°C)CW
136<Logic {{2114:1}}> Input1 Byte1 Byte5.10 counter pulses (0..255)CW
136<Logic {{2114:1}}> Input A CountInput A Count1 Byte6.10 counter pulses (-128..127)CW
136<Logic {{2114:1}}> Input A UCountInput A UCount1 Byte5.10 counter pulses (0..255)CW
136<Logic {{2114:1}}> Input HVACComf/Standby/Eco/B.protection1 Byte20.102 HVAC modeCW
136<Logic {{2114:1}}> Input StatusInput Count1 Byte6.10 counter pulses (-128..127)CW
136<Logic {{2114:1}}> Input StatusInput UCount1 Byte5.10 counter pulses (0..255)CW
136<Logic {{2114:1}}> Input1 Bit1 Bit1.2 booleanCW
136<Logic {{2114:1}}> InputLogic1 Bit1.2 booleanCW
136<Logic {{2114:1}}> Input ALogic1 Bit1.2 booleanCW
136<Logic {{2114:1}}> Input A BitInput A Bit1 Bit1.2 booleanCW
136<Logic {{2114:1}}> Input Speed 1Off/On1 Bit1.1 switchCW
136<Logic {{2114:1}}> Output Speed 1Off/On1 Bit1.1 switchCRT
136<Logic {{2114:1}}> Input StatusInput Bit1 Bit1.1 switchCW
136<Logic {{2114:1}}> Command for PresenceOff/On1 Bit1.1 switchCW
136<VH> Remote Inputs Enable (Global Enable)Remote Inputs Enable (Global Enable)1 Bit1.2 booleanCW
137<Logic {{2114:1}}> Input B 4Byte CountInput B 4Byte Count4 Bytes13.1 counter pulses (signed)CW
137<Logic {{2114:1}}> Input B 4Byte UCountInput B 4Byte UCount4 Bytes12.1 counter pulses (unsigned)CW
137<Logic {{2114:1}}> Input B 4Byte FloatInput B 4Byte Float4 Bytes14.56 power (W)CW
137<Logic {{2114:1}}> Input B 2Byte CountInput B 2Byte Count2 Bytes8.1 pulses differenceCW
137<Logic {{2114:1}}> Input B 2Byte UCountInput B 2Byte UCount2 Bytes7.1 pulsesCW
137<Logic {{2114:1}}> Input B 2Byte FloatInput B 2Byte Float2 Bytes9.1 temperature (°C)CW
137<Logic {{2114:1}}> Input Regulation TemperatureValue °C2 Bytes9.1 temperature (°C)CW
137<Logic {{2114:1}}> Illuminance MeasuredLux2 Bytes9.4 lux (Lux)CW
137<Logic {{2114:1}}> Input B CountInput B Count1 Byte6.10 counter pulses (-128..127)CW
137<Logic {{2114:1}}> Input B UCountInput B UCount1 Byte5.10 counter pulses (0..255)CW
137<Logic {{2114:1}}> Input BLogic1 Bit1.2 booleanCW
137<Logic {{2114:1}}> Input B BitInput B Bit1 Bit1.2 booleanCW
137<Logic {{2114:1}}> Input Heat/CoolHeat/Cool1 Bit1.100 heating/coolingCW
137<Logic {{2114:1}}> Input Speed 2Off/On1 Bit1.1 switchCW
137<Logic {{2114:1}}> Output Speed 2Off/On1 Bit1.1 switchCRT
137<Logic {{2114:1}}> Input ResetOff/On1 Bit1.1 switchCW
137<VH> Presence OutputPresence Output1 Bit1.2 booleanCRT
138<Logic {{2114:1}}> Input C 4Byte CountInput C 4Byte Count4 Bytes13.1 counter pulses (signed)CW
138<Logic {{2114:1}}> Input C 4Byte UCountInput C 4Byte UCount4 Bytes12.1 counter pulses (unsigned)CW
138<Logic {{2114:1}}> Input C 4Byte FloatInput C 4Byte Float4 Bytes14.56 power (W)CW
138<Logic {{2114:1}}> Input C 2Byte CountInput C 2Byte Count2 Bytes8.1 pulses differenceCW
138<Logic {{2114:1}}> Input C 2Byte UCountInput C 2Byte UCount2 Bytes7.1 pulsesCW
138<Logic {{2114:1}}> Input C 2Byte FloatInput C 2Byte Float2 Bytes9.1 temperature (°C)CW
138<Logic {{2114:1}}> Output Dew Point TemperatureValue °C2 Bytes9.1 temperature (°C)CRT
138<Logic {{2114:1}}> Illuminance SetpointLux2 Bytes9.4 lux (Lux)CW
138<Logic {{2114:1}}> Input C CountInput C Count1 Byte6.10 counter pulses (-128..127)CW
138<Logic {{2114:1}}> Input C UCountInput C UCount1 Byte5.10 counter pulses (0..255)CW
138<Logic {{2114:1}}> Output Valve %Value %1 Byte5.1 percentage (0..100%)CRT
138<Logic {{2114:1}}> Output Heat Valve %Value %1 Byte5.1 percentage (0..100%)CRT
138<VH> HVAC OutputHVAC Output1 Byte20.102 HVAC modeCRT
138<Logic {{2114:1}}> Input C BitInput C Bit1 Bit1.2 booleanCW
138<Logic {{2114:1}}> Input Speed 3Off/On1 Bit1.1 switchCW
138<Logic {{2114:1}}> Output Speed 3Off/On1 Bit1.1 switchCRT
138<Logic {{2114:1}}> Output AlarmOff/On1 Bit1.1 switchCRT
139<Logic {{2114:1}}> Input D 4Byte CountInput D 4Byte Count4 Bytes13.1 counter pulses (signed)CW
139<Logic {{2114:1}}> Input D 4Byte UCountInput D 4Byte UCount4 Bytes12.1 counter pulses (unsigned)CW
139<Logic {{2114:1}}> Input D 4Byte FloatInput D 4Byte Float4 Bytes14.56 power (W)CW
139<Logic {{2114:1}}> Input D 2Byte CountInput D 2Byte Count2 Bytes8.1 pulses differenceCW
139<Logic {{2114:1}}> Input D 2Byte UCountInput D 2Byte UCount2 Bytes7.1 pulsesCW
139<Logic {{2114:1}}> Input D 2Byte FloatInput D 2Byte Float2 Bytes9.1 temperature (°C)CW
139<Logic {{2114:1}}> Input D CountInput D Count1 Byte6.10 counter pulses (-128..127)CW
139<Logic {{2114:1}}> Input D UCountInput D UCount1 Byte5.10 counter pulses (0..255)CW
139<Logic {{2114:1}}> Output Cool Valve %Value %1 Byte5.1 percentage (0..100%)CRT
139<Logic {{2114:1}}> Output Value %Value %1 Byte5.1 percentage (0..100%)CRT
139<Logic {{2114:1}}> Output BrightnessValue 0-100%1 Byte5.1 percentage (0..100%)CRT
139<VH> Additional OutputAdditional Output1 Byte5.10 counter pulses (0..255)CRT
139<VH> Additional OutputAdditional Output1 Byte5.1 percentage (0..100%)CRT
139<VH> Additional OutputAdditional Output1 Byte17.1 scene numberCRT
139<Logic {{2114:1}}> Input D BitInput D Bit1 Bit1.2 booleanCW
139<Logic {{2114:1}}> Input Enable/DisableDisable/Enable1 Bit1.3 enableCW
139<Logic {{2114:1}}> Output CommandOff/On1 Bit1.1 switchCRT
140<Logic {{2211:2}}> Output 4Byte CountOutput 4Byte Count4 Bytes13.1 counter pulses (signed)CRT
140<Logic {{2211:2}}> Output 4Byte UCountOutput 4Byte UCount4 Bytes12.1 counter pulses (unsigned)CRT
140<Logic {{2211:2}}> Output 4Byte FloatOutput 4Byte Float4 Bytes14.56 power (W)CRT
140<Logic {{2211:2}}> Input SurveillanceInput 4Byte Count4 Bytes13.1 counter pulses (signed)CW
140<Logic {{2211:2}}> Input SurveillanceInput 4Byte UCount4 Bytes12.1 counter pulses (unsigned)CW
140<Logic {{2211:2}}> Input SurveillanceInput 4Byte Float4 Bytes14.56 power (W)CW
140<Logic {{2211:2}}> Output 2Byte CountOutput 2Byte Count2 Bytes8.1 pulses differenceCRT
140<Logic {{2211:2}}> Output 2Byte UCountOutput 2Byte UCount2 Bytes7.1 pulsesCRT
140<Logic {{2211:2}}> Output 2Byte FloatOutput 2Byte Float2 Bytes9.1 temperature (°C)CRT
140<Logic {{2211:2}}> Input TemperatureValue °C2 Bytes9.1 temperature (°C)CW
140<Logic {{2211:2}}> Input SurveillanceInput 2Byte Count2 Bytes8.1 pulses differenceCW
140<Logic {{2211:2}}> Input SurveillanceInput 2Byte UCount2 Bytes7.1 pulsesCW
140<Logic {{2211:2}}> Input SurveillanceInput 2Byte Float2 Bytes9.1 temperature (°C)CW
140<Logic {{2211:2}}> Output1 Byte1 Byte5.10 counter pulses (0..255)CRT
140<Logic {{2211:2}}> Output CountOutput Count1 Byte6.10 counter pulses (-128..127)CRT
140<Logic {{2211:2}}> Output UCountOutput UCount1 Byte5.10 counter pulses (0..255)CRT
140<Logic {{2211:2}}> Output Value %Value %1 Byte5.1 percentage (0..100%)CRT
140<Logic {{2211:2}}> Input Value %Value %1 Byte5.1 percentage (0..100%)CW
140<Logic {{2211:2}}> Input SurveillanceInput Count1 Byte6.10 counter pulses (-128..127)CW
140<Logic {{2211:2}}> Input SurveillanceInput UCount1 Byte5.10 counter pulses (0..255)CW
140<Logic {{2211:2}}> Output1 Bit1 Bit1.2 booleanCRT
140<Logic {{2211:2}}> OutputLogic1 Bit1.2 booleanCRT
140<Logic {{2211:2}}> Output BitOutput Bit1 Bit1.2 booleanCRT
140<Logic {{2211:2}}> Input SurveillanceInput Bit1 Bit1.1 switchCW
140<Logic {{2211:2}}> Command for SemiautomaticOff/On1 Bit1.1 switchCW
141<Logic {{2211:2}}> Input4 Bytes4 Bytes14.56 power (W)CW
141<Logic {{2211:2}}> Input A 4Byte CountInput A 4Byte Count4 Bytes13.1 counter pulses (signed)CW
141<Logic {{2211:2}}> Input A 4Byte UCountInput A 4Byte UCount4 Bytes12.1 counter pulses (unsigned)CW
141<Logic {{2211:2}}> Input A 4Byte FloatInput A 4Byte Float4 Bytes14.56 power (W)CW
141<Logic {{2211:2}}> Input StatusInput 4Byte Count4 Bytes13.1 counter pulses (signed)CW
141<Logic {{2211:2}}> Input StatusInput 4Byte UCount4 Bytes12.1 counter pulses (unsigned)CW
141<Logic {{2211:2}}> Input StatusInput 4Byte Float4 Bytes14.56 power (W)CW
141<Logic {{2211:2}}> Input2 Bytes2 Bytes9.1 temperature (°C)CW
141<Logic {{2211:2}}> Input A 2Byte CountInput A 2Byte Count2 Bytes8.1 pulses differenceCW
141<Logic {{2211:2}}> Input A 2Byte UCountInput A 2Byte UCount2 Bytes7.1 pulsesCW
141<Logic {{2211:2}}> Input A 2Byte FloatInput A 2Byte Float2 Bytes9.1 temperature (°C)CW
141<Logic {{2211:2}}> Input SetpointValue °C2 Bytes9.1 temperature (°C)CW
141<Logic {{2211:2}}> Input Relative HumidityHumidity %2 Bytes9.7 humidity (%)CW
141<Logic {{2211:2}}> Input StatusInput 2Byte Count2 Bytes8.1 pulses differenceCW
141<Logic {{2211:2}}> Input StatusInput 2Byte UCount2 Bytes7.1 pulsesCW
141<Logic {{2211:2}}> Input StatusInput 2Byte Float2 Bytes9.1 temperature (°C)CW
141<Logic {{2211:2}}> Input1 Byte1 Byte5.10 counter pulses (0..255)CW
141<Logic {{2211:2}}> Input A CountInput A Count1 Byte6.10 counter pulses (-128..127)CW
141<Logic {{2211:2}}> Input A UCountInput A UCount1 Byte5.10 counter pulses (0..255)CW
141<Logic {{2211:2}}> Input HVACComf/Standby/Eco/B.protection1 Byte20.102 HVAC modeCW
141<Logic {{2211:2}}> Input StatusInput Count1 Byte6.10 counter pulses (-128..127)CW
141<Logic {{2211:2}}> Input StatusInput UCount1 Byte5.10 counter pulses (0..255)CW
141<Logic {{2211:2}}> Input1 Bit1 Bit1.2 booleanCW
141<Logic {{2211:2}}> InputLogic1 Bit1.2 booleanCW
141<Logic {{2211:2}}> Input ALogic1 Bit1.2 booleanCW
141<Logic {{2211:2}}> Input A BitInput A Bit1 Bit1.2 booleanCW
141<Logic {{2211:2}}> Input Speed 1Off/On1 Bit1.1 switchCW
141<Logic {{2211:2}}> Output Speed 1Off/On1 Bit1.1 switchCRT
141<Logic {{2211:2}}> Input StatusInput Bit1 Bit1.1 switchCW
141<Logic {{2211:2}}> Command for PresenceOff/On1 Bit1.1 switchCW
141<VH> Presence for Guest (Type1)Presence for Guest (Type1)1 Bit1.2 booleanCRT
142<Logic {{2211:2}}> Input B 4Byte CountInput B 4Byte Count4 Bytes13.1 counter pulses (signed)CW
142<Logic {{2211:2}}> Input B 4Byte UCountInput B 4Byte UCount4 Bytes12.1 counter pulses (unsigned)CW
142<Logic {{2211:2}}> Input B 4Byte FloatInput B 4Byte Float4 Bytes14.56 power (W)CW
142<Logic {{2211:2}}> Input B 2Byte CountInput B 2Byte Count2 Bytes8.1 pulses differenceCW
142<Logic {{2211:2}}> Input B 2Byte UCountInput B 2Byte UCount2 Bytes7.1 pulsesCW
142<Logic {{2211:2}}> Input B 2Byte FloatInput B 2Byte Float2 Bytes9.1 temperature (°C)CW
142<Logic {{2211:2}}> Input Regulation TemperatureValue °C2 Bytes9.1 temperature (°C)CW
142<Logic {{2211:2}}> Illuminance MeasuredLux2 Bytes9.4 lux (Lux)CW
142<Logic {{2211:2}}> Input B CountInput B Count1 Byte6.10 counter pulses (-128..127)CW
142<Logic {{2211:2}}> Input B UCountInput B UCount1 Byte5.10 counter pulses (0..255)CW
142<Logic {{2211:2}}> Input BLogic1 Bit1.2 booleanCW
142<Logic {{2211:2}}> Input B BitInput B Bit1 Bit1.2 booleanCW
142<Logic {{2211:2}}> Input Heat/CoolHeat/Cool1 Bit1.100 heating/coolingCW
142<Logic {{2211:2}}> Input Speed 2Off/On1 Bit1.1 switchCW
142<Logic {{2211:2}}> Output Speed 2Off/On1 Bit1.1 switchCRT
142<Logic {{2211:2}}> Input ResetOff/On1 Bit1.1 switchCW
142<VH> Signal Guest (Type1)Signal Guest (Type1)1 Bit1.2 booleanCW
143<Logic {{2211:2}}> Input C 4Byte CountInput C 4Byte Count4 Bytes13.1 counter pulses (signed)CW
143<Logic {{2211:2}}> Input C 4Byte UCountInput C 4Byte UCount4 Bytes12.1 counter pulses (unsigned)CW
143<Logic {{2211:2}}> Input C 4Byte FloatInput C 4Byte Float4 Bytes14.56 power (W)CW
143<Logic {{2211:2}}> Input C 2Byte CountInput C 2Byte Count2 Bytes8.1 pulses differenceCW
143<Logic {{2211:2}}> Input C 2Byte UCountInput C 2Byte UCount2 Bytes7.1 pulsesCW
143<Logic {{2211:2}}> Input C 2Byte FloatInput C 2Byte Float2 Bytes9.1 temperature (°C)CW
143<Logic {{2211:2}}> Output Dew Point TemperatureValue °C2 Bytes9.1 temperature (°C)CRT
143<Logic {{2211:2}}> Illuminance SetpointLux2 Bytes9.4 lux (Lux)CW
143<Logic {{2211:2}}> Input C CountInput C Count1 Byte6.10 counter pulses (-128..127)CW
143<Logic {{2211:2}}> Input C UCountInput C UCount1 Byte5.10 counter pulses (0..255)CW
143<Logic {{2211:2}}> Output Valve %Value %1 Byte5.1 percentage (0..100%)CRT
143<Logic {{2211:2}}> Output Heat Valve %Value %1 Byte5.1 percentage (0..100%)CRT
143<Logic {{2211:2}}> Input C BitInput C Bit1 Bit1.2 booleanCW
143<Logic {{2211:2}}> Input Speed 3Off/On1 Bit1.1 switchCW
143<Logic {{2211:2}}> Output Speed 3Off/On1 Bit1.1 switchCRT
143<Logic {{2211:2}}> Output AlarmOff/On1 Bit1.1 switchCRT
143<VH> Presence for Service (Type2)Presence for Service (Type2)1 Bit1.2 booleanCRT
144<Logic {{2211:2}}> Input D 4Byte CountInput D 4Byte Count4 Bytes13.1 counter pulses (signed)CW
144<Logic {{2211:2}}> Input D 4Byte UCountInput D 4Byte UCount4 Bytes12.1 counter pulses (unsigned)CW
144<Logic {{2211:2}}> Input D 4Byte FloatInput D 4Byte Float4 Bytes14.56 power (W)CW
144<Logic {{2211:2}}> Input D 2Byte CountInput D 2Byte Count2 Bytes8.1 pulses differenceCW
144<Logic {{2211:2}}> Input D 2Byte UCountInput D 2Byte UCount2 Bytes7.1 pulsesCW
144<Logic {{2211:2}}> Input D 2Byte FloatInput D 2Byte Float2 Bytes9.1 temperature (°C)CW
144<Logic {{2211:2}}> Input D CountInput D Count1 Byte6.10 counter pulses (-128..127)CW
144<Logic {{2211:2}}> Input D UCountInput D UCount1 Byte5.10 counter pulses (0..255)CW
144<Logic {{2211:2}}> Output Cool Valve %Value %1 Byte5.1 percentage (0..100%)CRT
144<Logic {{2211:2}}> Output Value %Value %1 Byte5.1 percentage (0..100%)CRT
144<Logic {{2211:2}}> Output BrightnessValue 0-100%1 Byte5.1 percentage (0..100%)CRT
144<Logic {{2211:2}}> Input D BitInput D Bit1 Bit1.2 booleanCW
144<Logic {{2211:2}}> Input Enable/DisableDisable/Enable1 Bit1.3 enableCW
144<Logic {{2211:2}}> Output CommandOff/On1 Bit1.1 switchCRT
144<VH> Signal Service (Type2)Signal Service (Type2)1 Bit1.2 booleanCW
145<Logic {{2308:3}}> Output 4Byte CountOutput 4Byte Count4 Bytes13.1 counter pulses (signed)CRT
145<Logic {{2308:3}}> Output 4Byte UCountOutput 4Byte UCount4 Bytes12.1 counter pulses (unsigned)CRT
145<Logic {{2308:3}}> Output 4Byte FloatOutput 4Byte Float4 Bytes14.56 power (W)CRT
145<Logic {{2308:3}}> Input SurveillanceInput 4Byte Count4 Bytes13.1 counter pulses (signed)CW
145<Logic {{2308:3}}> Input SurveillanceInput 4Byte UCount4 Bytes12.1 counter pulses (unsigned)CW
145<Logic {{2308:3}}> Input SurveillanceInput 4Byte Float4 Bytes14.56 power (W)CW
145<Logic {{2308:3}}> Output 2Byte CountOutput 2Byte Count2 Bytes8.1 pulses differenceCRT
145<Logic {{2308:3}}> Output 2Byte UCountOutput 2Byte UCount2 Bytes7.1 pulsesCRT
145<Logic {{2308:3}}> Output 2Byte FloatOutput 2Byte Float2 Bytes9.1 temperature (°C)CRT
145<Logic {{2308:3}}> Input TemperatureValue °C2 Bytes9.1 temperature (°C)CW
145<Logic {{2308:3}}> Input SurveillanceInput 2Byte Count2 Bytes8.1 pulses differenceCW
145<Logic {{2308:3}}> Input SurveillanceInput 2Byte UCount2 Bytes7.1 pulsesCW
145<Logic {{2308:3}}> Input SurveillanceInput 2Byte Float2 Bytes9.1 temperature (°C)CW
145<Logic {{2308:3}}> Output1 Byte1 Byte5.10 counter pulses (0..255)CRT
145<Logic {{2308:3}}> Output CountOutput Count1 Byte6.10 counter pulses (-128..127)CRT
145<Logic {{2308:3}}> Output UCountOutput UCount1 Byte5.10 counter pulses (0..255)CRT
145<Logic {{2308:3}}> Output Value %Value %1 Byte5.1 percentage (0..100%)CRT
145<Logic {{2308:3}}> Input Value %Value %1 Byte5.1 percentage (0..100%)CW
145<Logic {{2308:3}}> Input SurveillanceInput Count1 Byte6.10 counter pulses (-128..127)CW
145<Logic {{2308:3}}> Input SurveillanceInput UCount1 Byte5.10 counter pulses (0..255)CW
145<Logic {{2308:3}}> Output1 Bit1 Bit1.2 booleanCRT
145<Logic {{2308:3}}> OutputLogic1 Bit1.2 booleanCRT
145<Logic {{2308:3}}> Output BitOutput Bit1 Bit1.2 booleanCRT
145<Logic {{2308:3}}> Input SurveillanceInput Bit1 Bit1.1 switchCW
145<Logic {{2308:3}}> Command for SemiautomaticOff/On1 Bit1.1 switchCW
145<VH> Presence for Maintenance (Type3)Presence for Maintenance (Type3)1 Bit1.2 booleanCRT
146<Logic {{2308:3}}> Input4 Bytes4 Bytes14.56 power (W)CW
146<Logic {{2308:3}}> Input A 4Byte CountInput A 4Byte Count4 Bytes13.1 counter pulses (signed)CW
146<Logic {{2308:3}}> Input A 4Byte UCountInput A 4Byte UCount4 Bytes12.1 counter pulses (unsigned)CW
146<Logic {{2308:3}}> Input A 4Byte FloatInput A 4Byte Float4 Bytes14.56 power (W)CW
146<Logic {{2308:3}}> Input StatusInput 4Byte Count4 Bytes13.1 counter pulses (signed)CW
146<Logic {{2308:3}}> Input StatusInput 4Byte UCount4 Bytes12.1 counter pulses (unsigned)CW
146<Logic {{2308:3}}> Input StatusInput 4Byte Float4 Bytes14.56 power (W)CW
146<Logic {{2308:3}}> Input2 Bytes2 Bytes9.1 temperature (°C)CW
146<Logic {{2308:3}}> Input A 2Byte CountInput A 2Byte Count2 Bytes8.1 pulses differenceCW
146<Logic {{2308:3}}> Input A 2Byte UCountInput A 2Byte UCount2 Bytes7.1 pulsesCW
146<Logic {{2308:3}}> Input A 2Byte FloatInput A 2Byte Float2 Bytes9.1 temperature (°C)CW
146<Logic {{2308:3}}> Input SetpointValue °C2 Bytes9.1 temperature (°C)CW
146<Logic {{2308:3}}> Input Relative HumidityHumidity %2 Bytes9.7 humidity (%)CW
146<Logic {{2308:3}}> Input StatusInput 2Byte Count2 Bytes8.1 pulses differenceCW
146<Logic {{2308:3}}> Input StatusInput 2Byte UCount2 Bytes7.1 pulsesCW
146<Logic {{2308:3}}> Input StatusInput 2Byte Float2 Bytes9.1 temperature (°C)CW
146<Logic {{2308:3}}> Input1 Byte1 Byte5.10 counter pulses (0..255)CW
146<Logic {{2308:3}}> Input A CountInput A Count1 Byte6.10 counter pulses (-128..127)CW
146<Logic {{2308:3}}> Input A UCountInput A UCount1 Byte5.10 counter pulses (0..255)CW
146<Logic {{2308:3}}> Input HVACComf/Standby/Eco/B.protection1 Byte20.102 HVAC modeCW
146<Logic {{2308:3}}> Input StatusInput Count1 Byte6.10 counter pulses (-128..127)CW
146<Logic {{2308:3}}> Input StatusInput UCount1 Byte5.10 counter pulses (0..255)CW
146<Logic {{2308:3}}> Input1 Bit1 Bit1.2 booleanCW
146<Logic {{2308:3}}> InputLogic1 Bit1.2 booleanCW
146<Logic {{2308:3}}> Input ALogic1 Bit1.2 booleanCW
146<Logic {{2308:3}}> Input A BitInput A Bit1 Bit1.2 booleanCW
146<Logic {{2308:3}}> Input Speed 1Off/On1 Bit1.1 switchCW
146<Logic {{2308:3}}> Output Speed 1Off/On1 Bit1.1 switchCRT
146<Logic {{2308:3}}> Input StatusInput Bit1 Bit1.1 switchCW
146<Logic {{2308:3}}> Command for PresenceOff/On1 Bit1.1 switchCW
146<VH> Signal Maintenance (Type3)Signal Maintenance (Type3)1 Bit1.2 booleanCW
147<Logic {{2308:3}}> Input B 4Byte CountInput B 4Byte Count4 Bytes13.1 counter pulses (signed)CW
147<Logic {{2308:3}}> Input B 4Byte UCountInput B 4Byte UCount4 Bytes12.1 counter pulses (unsigned)CW
147<Logic {{2308:3}}> Input B 4Byte FloatInput B 4Byte Float4 Bytes14.56 power (W)CW
147<Logic {{2308:3}}> Input B 2Byte CountInput B 2Byte Count2 Bytes8.1 pulses differenceCW
147<Logic {{2308:3}}> Input B 2Byte UCountInput B 2Byte UCount2 Bytes7.1 pulsesCW
147<Logic {{2308:3}}> Input B 2Byte FloatInput B 2Byte Float2 Bytes9.1 temperature (°C)CW
147<Logic {{2308:3}}> Input Regulation TemperatureValue °C2 Bytes9.1 temperature (°C)CW
147<Logic {{2308:3}}> Illuminance MeasuredLux2 Bytes9.4 lux (Lux)CW
147<Logic {{2308:3}}> Input B CountInput B Count1 Byte6.10 counter pulses (-128..127)CW
147<Logic {{2308:3}}> Input B UCountInput B UCount1 Byte5.10 counter pulses (0..255)CW
147<Logic {{2308:3}}> Input BLogic1 Bit1.2 booleanCW
147<Logic {{2308:3}}> Input B BitInput B Bit1 Bit1.2 booleanCW
147<Logic {{2308:3}}> Input Heat/CoolHeat/Cool1 Bit1.100 heating/coolingCW
147<Logic {{2308:3}}> Input Speed 2Off/On1 Bit1.1 switchCW
147<Logic {{2308:3}}> Output Speed 2Off/On1 Bit1.1 switchCRT
147<Logic {{2308:3}}> Input ResetOff/On1 Bit1.1 switchCW
147<VH> Remote Input 1 DoorRemote Input 1 Door1 Bit1.2 booleanCW
147<VH> Remote Input 1 PresenceRemote Input 1 Presence1 Bit1.2 booleanCW
147<VH> Remote Input 1 SnifferRemote Input 1 Sniffer1 Bit1.2 booleanCW
148<Logic {{2308:3}}> Input C 4Byte CountInput C 4Byte Count4 Bytes13.1 counter pulses (signed)CW
148<Logic {{2308:3}}> Input C 4Byte UCountInput C 4Byte UCount4 Bytes12.1 counter pulses (unsigned)CW
148<Logic {{2308:3}}> Input C 4Byte FloatInput C 4Byte Float4 Bytes14.56 power (W)CW
148<Logic {{2308:3}}> Input C 2Byte CountInput C 2Byte Count2 Bytes8.1 pulses differenceCW
148<Logic {{2308:3}}> Input C 2Byte UCountInput C 2Byte UCount2 Bytes7.1 pulsesCW
148<Logic {{2308:3}}> Input C 2Byte FloatInput C 2Byte Float2 Bytes9.1 temperature (°C)CW
148<Logic {{2308:3}}> Output Dew Point TemperatureValue °C2 Bytes9.1 temperature (°C)CRT
148<Logic {{2308:3}}> Illuminance SetpointLux2 Bytes9.4 lux (Lux)CW
148<Logic {{2308:3}}> Input C CountInput C Count1 Byte6.10 counter pulses (-128..127)CW
148<Logic {{2308:3}}> Input C UCountInput C UCount1 Byte5.10 counter pulses (0..255)CW
148<Logic {{2308:3}}> Output Valve %Value %1 Byte5.1 percentage (0..100%)CRT
148<Logic {{2308:3}}> Output Heat Valve %Value %1 Byte5.1 percentage (0..100%)CRT
148<Logic {{2308:3}}> Input C BitInput C Bit1 Bit1.2 booleanCW
148<Logic {{2308:3}}> Input Speed 3Off/On1 Bit1.1 switchCW
148<Logic {{2308:3}}> Output Speed 3Off/On1 Bit1.1 switchCRT
148<Logic {{2308:3}}> Output AlarmOff/On1 Bit1.1 switchCRT
148<VH> Remote Input 2 DoorRemote Input 2 Door1 Bit1.2 booleanCW
148<VH> Remote Input 2 PresenceRemote Input 2 Presence1 Bit1.2 booleanCW
148<VH> Remote Input 2 SnifferRemote Input 2 Sniffer1 Bit1.2 booleanCW
149<Logic {{2308:3}}> Input D 4Byte CountInput D 4Byte Count4 Bytes13.1 counter pulses (signed)CW
149<Logic {{2308:3}}> Input D 4Byte UCountInput D 4Byte UCount4 Bytes12.1 counter pulses (unsigned)CW
149<Logic {{2308:3}}> Input D 4Byte FloatInput D 4Byte Float4 Bytes14.56 power (W)CW
149<Logic {{2308:3}}> Input D 2Byte CountInput D 2Byte Count2 Bytes8.1 pulses differenceCW
149<Logic {{2308:3}}> Input D 2Byte UCountInput D 2Byte UCount2 Bytes7.1 pulsesCW
149<Logic {{2308:3}}> Input D 2Byte FloatInput D 2Byte Float2 Bytes9.1 temperature (°C)CW
149<Logic {{2308:3}}> Input D CountInput D Count1 Byte6.10 counter pulses (-128..127)CW
149<Logic {{2308:3}}> Input D UCountInput D UCount1 Byte5.10 counter pulses (0..255)CW
149<Logic {{2308:3}}> Output Cool Valve %Value %1 Byte5.1 percentage (0..100%)CRT
149<Logic {{2308:3}}> Output Value %Value %1 Byte5.1 percentage (0..100%)CRT
149<Logic {{2308:3}}> Output BrightnessValue 0-100%1 Byte5.1 percentage (0..100%)CRT
149<Logic {{2308:3}}> Input D BitInput D Bit1 Bit1.2 booleanCW
149<Logic {{2308:3}}> Input Enable/DisableDisable/Enable1 Bit1.3 enableCW
149<Logic {{2308:3}}> Output CommandOff/On1 Bit1.1 switchCRT
149<VH> Remote Input 3 DoorRemote Input 3 Door1 Bit1.2 booleanCW
149<VH> Remote Input 3 PresenceRemote Input 3 Presence1 Bit1.2 booleanCW
149<VH> Remote Input 3 SnifferRemote Input 3 Sniffer1 Bit1.2 booleanCW
150<Logic {{2405:4}}> Output 4Byte CountOutput 4Byte Count4 Bytes13.1 counter pulses (signed)CRT
150<Logic {{2405:4}}> Output 4Byte UCountOutput 4Byte UCount4 Bytes12.1 counter pulses (unsigned)CRT
150<Logic {{2405:4}}> Output 4Byte FloatOutput 4Byte Float4 Bytes14.56 power (W)CRT
150<Logic {{2405:4}}> Input SurveillanceInput 4Byte Count4 Bytes13.1 counter pulses (signed)CW
150<Logic {{2405:4}}> Input SurveillanceInput 4Byte UCount4 Bytes12.1 counter pulses (unsigned)CW
150<Logic {{2405:4}}> Input SurveillanceInput 4Byte Float4 Bytes14.56 power (W)CW
150<Logic {{2405:4}}> Output 2Byte CountOutput 2Byte Count2 Bytes8.1 pulses differenceCRT
150<Logic {{2405:4}}> Output 2Byte UCountOutput 2Byte UCount2 Bytes7.1 pulsesCRT
150<Logic {{2405:4}}> Output 2Byte FloatOutput 2Byte Float2 Bytes9.1 temperature (°C)CRT

First 1000 of 1199 group objects shown. Download the .knxprod for the full list.

Parameters (600)
ParameterTypeDefault
Delay to send telegrams on power up [s]unsignedInt 5…155
Buttonslistdisabled
Use buttonslistdo not use
Ledslistdisabled
Rear input analog digitallistdigital
Temperature function 1listtemperature function disabled
Temperature alarm object 1listdisabled
Temperature function 2listtemperature function disabled
Temperature alarm object 2listdisabled
Dew point controllistdisabled
Reference temperaturelistnone
Reference thermostatlistnone
Humidity sensorlistdisabled
CO2 sensorlistenabled
Has internal CO2 sourcelistyes
Has external CO2 sourcelistno
VOC sensorlistdisabled
Virtual holderlistdisabled
Enable cleaning objectlistdisabled
Timing cleaning modelist30 min
Telegram to activate cleaning modelisttelegram "1"
Enable brightness objectslistdisabled
Enable panel alarmlistdisabled
Panel alarm telegramlisttelegram "1"
Front Panelpicture
Enable special button 1listdisabled
Enable special button 2listdisabled
Enable special button 3listdisabled
Enable special button 4listdisabled
Enable special button 5listdisabled
Enable special button 6listdisabled
Brightness when LED is OFFlist0%
Brightness when LED is ONlist100%
Sleep mode (proximity)listdisabled
Standby time [s]unsignedInt 10…25530
Standby time [s]unsignedInt 0…2550
Brightness when LED is OFF - standbylist0%
Brightness when LED is ON - standbylist100%
Enable standby brightness objectslistdisabled
Led 1 ON behavior in sleep modelistgo off
Led 2 ON behavior in sleep modelistgo off
Led 3 ON behavior in sleep modelistgo off
Led 4 ON behavior in sleep modelistgo off
Led 5 ON behavior in sleep modelistgo off
Led 6 ON behavior in sleep modelistgo off
RGB behavior in sleep modelistgo off
Button press-release sensitivitylist70%
Beep durationlistnormal
Beep tonelistnormal
Button 1 beep on presslistdisabled
Button 2 beep on presslistdisabled
Button 3 beep on presslistdisabled
Button 4 beep on presslistdisabled
Button 5 beep on presslistdisabled
Button 6 beep on presslistdisabled
Proximity sensitivitylistmedium sensitive
Enable proximity objectlistdisabled
Value to send on proximityliston
Value to send on standbylistoff
Functionlistnothing
Button nametext
Object enablelistdisabled
Initial enable statelistenabled
Enable activation telegramlisttelegram "1"
Telegram associatedlist1 bit
Command associated with pressliston
Command associated with presslistvalue 0-100%
Value associated with pressunsignedInt 0…2550
Value associated with presslist0%
Value associated with presslistauto
Cyclic sending when button pressedlistnever
Feedback objectlistdisabled
Command associated with presslistnothing
Command associated with releaselistnothing
Command typelistvalue 0-100%
Value associated with releaseunsignedInt 0…2550
Value associated with releaselist0%
Value associated with releaselistauto
Communication object on releaselistdisabled
Minimum time long press buttonlist0.5 s
Command associated with short presslistnothing
Command associated with long presslistnothing
Value associated with short pressunsignedInt 0…2550
Value associated with short presslist0%
Value associated with short presslistauto
Value associated with long pressunsignedInt 0…2550
Value associated with long presslist0%
Value associated with long presslistauto
Communication object on long presslistdisabled
Dimming modelistbrighter/darker
Dimming steplistmaximum brightness
Dimming steplistminimum brightness
Dimming steplistmaximum/minimum brightness
Command drive shutterlistmove up/move down
Scene number (1-64)list1
Store scene on long presslistdisabled
Object enable scene learning from buslistdisabled
Delay between commandsunsignedInt 0…2550
Telegram associated with command Alist1 bit
Command typelistnothing
Telegram associated with command Blist1 bit
Telegram associated with command Clist1 bit
Command associated with operation 1listnothing
Command associated with operation 2listnothing
Value associated with operation 1unsignedInt 0…2550
Value associated with operation 1list0%
Value associated with operation 1listauto
Value associated with operation 2unsignedInt 0…2550
Value associated with operation 2list0%
Value associated with operation 2listauto
Number of objectslist2 objects
Number of steps in the sequencelist2
Long press to restart sequencelistdisabled
Min. time long press to restart sequencelist0.5 s
Restart functionlistrestart and send first
Value step longlista=off b=off c=off
Value step longlista=off b=off
Send only changed objectslistdisabled
Value step 1lista=off b=off
Value step 2lista=off b=off
Value step 3lista=off b=off
Value step 4lista=off b=off
Value step 1lista=off b=off c=off
Value step 2lista=off b=off c=off
Value step 3lista=off b=off c=off
Value step 4lista=off b=off c=off
Value step 5lista=off b=off c=off
Value step 6lista=off b=off c=off
Value step 7lista=off b=off c=off
Value step 8lista=off b=off c=off
Set valuelistred
Long press to change colorlistlong press disabled
Enable sending colors during transitionslistdisabled
RGB objects typelist3 objects of 1 byte
Command associatedlistreset all
Action associated with presslistenable
Color associated to "reset all"text#FFFFFF
Color associated to "make up room"text#00FF00
Color associated to "do not disturb"text#FF0000
Additional objectlistnone
Active edgelistsend on press
Number of valueslist3 values
Value AunsignedInt 0…2550
Value BunsignedInt 0…2551
Value CunsignedInt 0…2552
Value DunsignedInt 0…2553
Value EunsignedInt 0…2554
Value FunsignedInt 0…2555
Value GunsignedInt 0…2556
Value HunsignedInt 0…2557
Value IunsignedInt 0…2558
Special button nametext
Functionlistfancoil speed
Work overlistthermostat 1
Work overlistthermostat 2
Work overlistthermostat 3
Behaviour on presslistincrease
AutounsignedInt 0…11
Speed 0unsignedInt 0…11
Speed 1unsignedInt 0…11
Speed 2unsignedInt 0…11
Speed 3unsignedInt 0…11
CoolunsignedInt 0…11
HeatunsignedInt 0…11
Cycling for the following the HVAC valuelistfrom 'Building protection' to going up
ComfortunsignedInt 0…11
StandbyunsignedInt 0…11
EconomyunsignedInt 0…11
Building protectionunsignedInt 0…11
Behaviour on presslistdecrease
Range of Increaselist-/+ 3°C
Step of increase [°C]list0,1
Command sending interval on long press [ms]listnothing
ONunsignedInt 0…11
OFFunsignedInt 0…11
Thermostat OFFunsignedInt 0…11
Contact typelistnormally open
Long or short cyclic timeslistshort
Command associated with closureliston
Command associated with openingliston
Cyclic sending when contact closedlistnever
Cyclic sending when contact openedlistnever
Command associated with closurelistvalue 0-100%
Command associated with openinglistvalue 0-100%
Value associated with closureunsignedInt 0…2550
Value associated with openingunsignedInt 0…2550
Value associated with closurelist0%
Value associated with openinglist0%
Value associated with closurelistauto
Value associated with openinglistauto
Command associated with closurelistnothing
Command associated with openinglistnothing
Communication object on openinglistdisabled
Minimum time long closurelist0.5 s
Command associated with short closurelistnothing
Command associated with long closurelistnothing
Value associated with short closureunsignedInt 0…2550
Value associated with short closurelist0%
Value associated with short closurelistauto
Value associated with long closureunsignedInt 0…2550
Value associated with long closurelist0%
Value associated with long closurelistauto
Communication object on long closurelistdisabled
Minimum time long closurelist2.0 s
Store scene on long closurelistdisabled
Long closure to restart sequencelistdisabled
Min. time long closure to restart sequencelist1.0 s
Long closure to change colorlistlong closure disabled
Action associated with closurelistenable
Active edgelistsend on closing
LED configurationlistalways off
LED activation telegramlisttelegram "1"
LED initial Statelistoff
LED blink periodlistfixed
Brightness limitlistnone
Brightness limit daylist100%
Brightness limit nightlist50%
Telegram activation for night modelisttelegram "1"
Initial brightnesslist100%
RGB main functionlistnothing
RGB main function valuelistnothing
Activation telegramlisttelegram "1"
Initial color settinglistcolor list
Initial colorlistwhite
Initial colortext#FFFFFF
Led ON behaviourlistfixed
Initial state led RGBlistoff
Object ON/OFFlistenabled
Communication object typelistboth
Number of KNX feedbacklist2
Activation telegram KNX feedback 1listtelegram "0"
Color KNX feedback 1listwhite
Activation telegram KNX feedback 2listtelegram "0"
Color KNX feedback 2listwhite
Activation telegram KNX feedback 3listtelegram "0"
Color KNX feedback 3listwhite
Activation telegram KNX feedback 4listtelegram "0"
Color KNX feedback 4listwhite
Activation telegram KNX feedback 5listtelegram "0"
Color KNX feedback 5listwhite
Physical dimensionliststandard physical dimension
RGB wheelpicture
Physical dimension sizelist4 bytes float
Min physical valuesignedInt -128…127-128
Max physical valuesignedInt -128…127127
Min physical valueunsignedInt 0…2550
Max physical valueunsignedInt 0…255255
Min physical valuesignedInt -32768…32767-32768
Max physical valuesignedInt -32768…3276732767
Min physical valueunsignedInt 0…655350
Max physical valueunsignedInt 0…6553565535
Min physical valuefloat -671088…670760-671088
Max physical valuefloat -671088…670760670760
Min physical valuesignedInt -2147483648…2147483647-2147483648
Max physical valuesignedInt -2147483648…21474836472147483647
Min physical valueunsignedInt 0…42949672950
Max physical valueunsignedInt 0…42949672954294967295
Min physical valuefloat -9223372036854776000…87622034350120370000
Max physical valuefloat -9223372036854776000…87622034350120370000
Standard physical dimensionlist0-100%
Min physical valuelist0%
Max physical valuelist100%
Min physical valuefloat -671088…67076010
Min physical valuefloat -671088…67076030
Min physical valuefloat -671088…670760300
Max physical valuefloat -671088…67076040
Max physical valuefloat -671088…67076070
Max physical valuefloat -671088…6707603000
Max physical valuefloat -9223372036854776000…87622034350120370003300
Min physical valuesignedInt -2147483648…21474836470
Max physical valuesignedInt -2147483648…2147483647500
Default colorlistred [0]
Color at minimum valuelistred [0]
Color at maximum valuelistred-magenta [11]
Color directionlistCW
Out scale min behaviourlistblink 1 s
Out scale max behaviourlistblink 1 s
Physical dimension size privatolist1 byte unsigned
Colors LEDlistall colors of wheel
Time of color changeunsignedInt 3…2553
Stop actionlistswitch off led
Stop telegramlisttelegram "1"
Color stoplistred
RGB temporary functionlistnothing
Color RGB Ledlistwhite
LED ON time [0=while pressed / 1..20=1..20 s]unsignedInt 0…2020
RGB step light modelistdisabled
Step light colorlistred
Blinklistblink 1 s
Internal Sensor feedbacklistthermostat
Internal Sensor feedbacklisthumidistat
Internal Sensor feedbacklistCO2 sensor
Thermostat sourcelistthermostat 1
Thermostat sourcelistthermostat 2
Thermostat sourcelistthermostat 3
Thermostat data to showlistHVAC
Use same colors between heat and coolunsignedInt 0…10
Min. temperature heat [°C]unsignedInt 0…6318
Max. temperature heat [°C]unsignedInt 0…6324
Min. temperature cool [°C]unsignedInt 0…6322
Max. temperature cool [°C]unsignedInt 0…6326
Humidity sourcelisthumidistat 1
Min. humiditylist40%
Ideal humiditylist50%
Max. humiditylist60%
Min. Colorlistblue
Ideal humidity colorlistgreen
Max. Colorlistred
CO2 sourcelistCO2 sensor 1
Min. value [ppm]unsignedInt 0…5000500
Max. value [ppm]unsignedInt 0…50001000
Min. Colorlistgreen
VOC sourcelistVOC sensor 1
Min. value [ppb]unsignedInt 0…5000500
Max. value [ppb]unsignedInt 0…50001000
Temperature sourcelistfrontal probe
Temperature objectlistdisabled
Sensor codelistTS01A01ACC
Weight external probelist50%
Weight internal probelist50%
External sensor calibration [0.1°C]signedInt -100…1000
Internal sensor calibration [0.1°C]signedInt -100…1000
KNX sensor calibration [0.1°C]signedInt -100…1000
Sending intervallistnever
Sending on variationlistnever
Surveillance time for KNX probe (0=disabled) [min]unsignedInt 0…25515
State after downloadlistenabled
Hysteresislist0.5°C
Upper setpoint valuelist+25°C
Telegram when value is above setpointliston
Telegram when value is below setpointlistoff
Telegram when probe is disabledlistoff
Cyclic sending time of telegramlistno cyclic send
Lower setpoint valuelist+20°C
Telegram when value is above setpointlistoff
Telegram when value is below setpointliston
Use thermostat to control fan coilslistyes
Fan coil typelistfan coil control on / off
Enable 2nd stage controllistdisabled
Thermostat control modelistHVAC mode (switched heat/cool)
Value of heat/cool object after downloadlist1 = heating
Value of HVAC mode object after downloadlistcomfort
Enable 1bit comfort objectlistdisabled
Additional functionlistno function
Version (HVAC auto)listold version
Control type when comfort endsliststandby
Comfort object prioritylistno
Comfort object timinglisttime unlimited
Comfort overwrite time [min]unsignedInt 1…2551
EnableHeatOrCool or LockHClistenable heat or cool
Enable objectlistcooling
Enable telegramlisttelegram "1"
Lock telegramlisttelegram "1"
Enable setpoint adjustment objectlistenabled
Window contactlistdisabled
Window contact activation telegramlisttelegram "1"
Thermostat OFF objectlistdisabled
Thermostat OFF activation telegramlisttelegram "1"
Fancoil valvelistbit
Setpoint frost protectionlist7°C
Setpoint economy heating (Teh)list16°C
Setpoint standby heating (Tsh)list18°C
Setpoint comfort heating (Tch)list20°C
Setpoint high temperature protectionlist35°C
Setpoint economy cooling (Tec)list28°C
Setpoint standby cooling (Tsc)list26°C
Setpoint comfort cooling (Tcc)list24°C
Action to execute for setpointlistmodify absolute
Value of base setpoint object after downloadlist20°C
Dead bandlist2°C
Comfort setpointlistsetpoint H/C
Control algorithmlist2 points on/off control
Time period for on/off cyclic sendinglistno cyclic sending
Regulation differential value - heatinglist0.4°C
Heating systemlistwarm water (3 °C / 150 min)
Proportional band [Bp]list1°C
Cycle timelist10 min
Integration time [min] [Ti]unsignedInt 5…250200
Regulation differential value - coolinglist0.4°C
Cooling systemlistceiling cooling (5 °C / 240 min)
Reset SP adjustment on HEAT/COOL changelistno reset
Reset SP adjustment on HVAC economylistno reset
Adjustment allowedlist-/+ 3°C
Setpoint adjustment value formatlist2 bytes object - temperature value
Increase setpoint adjustment withlisttelegram "1"
Resolutionlist0.5°C
Keep SP adjustment on power uplistenabled
Enable fancoil speeds onlistheating / cooling
System typelist2 pipes
Enable additional valvelistdisabled
Speed numberlist3 speed
Regulation differential value S1-SP heatlist0°C
Regulation differential value SP-S1 coollist0°C
Regulation differential value S1-S2 heatlist0.8°C
Regulation differential value S2-S1 coollist0.8°C
Regulation differential value S2-S3 heatlist0.8°C
Regulation differential value S3-S2 coollist0.8°C
Manage valve independentlylistno
Regulation differential valve-cool-ONlist0.8°C
Regulation differential valve-heat-ONlist0.8°C
Regulation differential valve-cool-OFFlist0.8°C
Regulation differential valve-heat-OFFlist0.8°C
Cool valve bandgaplist0°C
Cool valve proportional band [Bp]list2.0°C
Heat valve bandgaplist0°C
Heat valve proportional band [Bp]list2.0°C
Initial value MAN (0) / AUTO (1) objectlist1
Enable ventilation object on/offlistdisabled
Ventilation after downloadlistoff
Integration time heat [min] [Ti]unsignedInt 5…250120
Proportional band heat [Bp]list1°C
Integration time cool [min] [Ti]unsignedInt 5…250120
Proportional band cool [Bp]list1°C
2nd stage heatinglistenabled
2nd stage heating telegramlist1 bit
Activation telegram 2nd stage heatinglisttelegram "1"
Bandgaplist0°C
Control typelistproportional
Proportional band [Bp]list2.0°C
Integration time [min] [Ti]unsignedInt 5…250120
Integration time [min] [Ti]unsignedInt 5…255120
Time period for cyclic sendinglistno cyclic sending
2nd stage coolinglistenabled
2nd stage cooling telegramlist1 bit
Activation telegram 2nd stage coolinglisttelegram "1"
Control algorithmlistintegral proportional control PWM
Control algorithm 6 wayslistnothing
Enable valve whenlistcooling
Percentage 100% coollist0%
Percentage 0% coollist33%
Value to send for valve fully closedlist50%
Percentage 0% heatlist67%
Percentage 100% heatlist100%
Set the differential values of the heat bandlistno
Set the differential values of the cool bandlistno
Proportional band heat [Bp]list2°C
Proportional band cool [Bp]list2°C
Regulation differential valve heat 0%list0°C
Regulation differential valve heat 100%list2.0°C
Regulation differential valve cool 0%list0°C
Regulation differential valve cool 100%list2.0°C
Humidistat Typelistdisabled
Enable state after downloadlistenabled
Humidity send on variationlist1%
Humidity periodic sendlistno periodic send
Hysteresislist0.5%
Sensor adjustmentlistnone
Upper thresholdunsignedInt 40…9060
Telegram when value is above thresholdlistnothing
Telegram when value is below thresholdlistnothing
Telegram when humidistat is disabledlistnothing
Lower thresholdunsignedInt 10…6040
Temperature sourcelisttemperature 1
Temperature sourcelisttemperature 2
Temperature sourcelisttemperature 3
Initial regulation temperaturelist15.0°C
Regulation temperature adjustmentlist0.0°C
Bandgap [0.1°C]signedInt -128…1270
Altitude (tens of meters above sea level)unsignedInt 0…25550
Output typelistoff/on
Sending intervallistno cyclic sending
Hysteresislist1.0°C
Sending on variationlist2 %
Proportional band [Bp] [0.1°C]unsignedInt 0…25530
Inverted controllistno
Sourcelistinternal sensor
Sourcelistexternal sensor
CO2 objectlistdisabled
Weight external sensorlist50%
Weight internal sensorlist50%
Internal sensor calibration [ppm]signedInt -1000…10000
External sensor calibration [ppm]signedInt -1000…10000
KNX sensor calibration [ppm]signedInt -1000…10000
Enable alarm objectlistdisabled
Sensor Typelistdisabled
Hysteresis [ppm]list40
Threshold value [ppm]unsignedInt 0…50003000
Telegram when sensor is disabledlistnothing
Threshold value [ppm]unsignedInt 0…50002000
Bandgap [ppm]signedInt -1000…10000
Proportional band [Bp] [ppm]unsignedInt 0…1000500
Cyclic sending time of telegramlistno cyclic sending
Send on variationlist2 %
Logic functionlistdisabled
Logic nametext
Logic delaylist0
Number of transmissions on outputlist1
Retransmission timelistshort
Retransmission delaylist2 s
Retransmission delaylist1 min
Value sent when 0 is receivedunsignedInt 0…2550
Value sent when 1 is receivedunsignedInt 0…255128
Byte valueunsignedInt 0…255128
Output bit when byte is receivedlist1
Output bit otherwiselist0
Threshold valueunsignedInt 0…255128
Output bit when input > thresholdlist1
Output bit when input <= thresholdlist0
Threshold valuefloat -671088…6707600
Threshold valuefloat -9223372036854776000…87622034350120370000

First 500 of 600 parameters shown. Download the .knxprod for the full list.

Version history

ApplicationApp noFingerprintFirst seenSizeFile
MC06A01KNX CO2 / Humidity / Temperature Controller 1.0 latest$0677EF342026-11-25602 KBDownload

About this file

This is the official ETS product database for the Eelectron MC06A01KNX CO2 / Humidity / Temperature Controller - A01 (MC06A01KNX), published by the manufacturer in the KNX online catalog. To use it, open ETS, go to Catalogs → Import and choose the downloaded .knxprod file. The device then appears in your catalog and can be added to a project. Older versions are kept so existing projects can be matched to the application program they were commissioned with.