KNX Database
CONTROLtronic ST3134 ST3134 KNX Blind Actuator SC 4-fold

ST3134 KNX Blind Actuator SC 4-fold ST3134

CONTROLtronic · Order number ST3134 · Blind › Blind Actuators

ScreenTronic

Download .knxprod ST3134 KNX Blind Actuator SC 4-fold 1.0 · 143 KB

Product

ManufacturerCONTROLtronic
Product nameST3134 KNX Blind Actuator SC 4-fold
Order numberST3134
HardwareHW_BA_25_4_3
MediumTwisted Pair
Bus current (mA)10
Rail mountedYes
Width (mm)70
RegistrationRegistered · 2025-07-23
Languagesde-DE, en-US
Catalog entryM-0087_H-ST3134-259_HP-6131-10-61CC_CI-ST3134-1
Fingerprint61CC
SHA-256eeaaed5026cda0cf9fa805bc23d9c5153d2684a0ad8e910437556d541911ef28
First seen2026-11-25
Markets57 markets

Application program: ST3134 KNX Blind Actuator SC 4-fold 1.0

Application number$6131
Version1.0
Mask versionMV-07B0 (System B)
KNX Data SecureNo
Minimum ETS version5.0
Parameters51
Group objects89
Group objects (89)
NoNameFunctionSizeDPTFlags
1SecurityAlarm1 BitDPT.1CW
10Blind 1Up/Down1 BitDPT.1CW
11Blind 1Stop/Step1 BitDPT.1CW
12Blind 1Slat tilting4 BitDPT.3CW
13Blind 1Height1 ByteDPT.5CW
14Blind 1Slat angle1 ByteDPT.5CW
15Blind 1Position combined3 BytesDPT.240CW
16Blind 1Scene activate1 ByteDPT.17CW
17Blind 1Disable manual control commands1 BitDPT.1CW
18Blind 1Up/Down (automatic)1 BitDPT.1CW
19Blind 1Height (automatic)1 ByteDPT.5CW
20Blind 1Slat angle (automatic)1 ByteDPT.5CW
21Blind 1Position combined (automatic)3 BytesDPT.240CW
22Blind 1Automatic1 BitDPT.1CW
23Blind 1Status Automatic1 BitDPT.1CRT
24Blind 1Reference movement1 BitDPT.1CW
25Blind 1Disable blind1 BitDPT.1CW
26Blind 1Status Height1 ByteDPT.5CRT
27Blind 1Status Slat angle1 ByteDPT.5CRT
28Blind 1Status Position combined3 BytesDPT.240CRT
29Blind 1Status Blind1 ByteDPT.21CRT
30Blind 1Status Communication error blind1 BitDPT.1CRT
31Blind 1Status Blind error1 ByteDPT.21CRT
40Blind 2Up/Down1 BitDPT.1CW
41Blind 2Stop/Step1 BitDPT.1CW
42Blind 2Slat tilting4 BitDPT.3CW
43Blind 2Height1 ByteDPT.5CW
44Blind 2Slat angle1 ByteDPT.5CW
45Blind 2Position combined3 BytesDPT.240CW
46Blind 2Scene activate1 ByteDPT.17CW
47Blind 2Disable manual control commands1 BitDPT.1CW
48Blind 2Up/Down (automatic)1 BitDPT.1CW
49Blind 2Height (automatic)1 ByteDPT.5CW
50Blind 2Slat angle (automatic)1 ByteDPT.5CW
51Blind 2Position combined (automatic)3 BytesDPT.240CW
52Blind 2Automatic1 BitDPT.1CW
53Blind 2Status Automatic1 BitDPT.1CRT
54Blind 2Reference movement1 BitDPT.1CW
55Blind 2Disable blind1 BitDPT.1CW
56Blind 2Status Height1 ByteDPT.5CRT
57Blind 2Status Slat angle1 ByteDPT.5CRT
58Blind 2Status Position combined3 BytesDPT.240CRT
59Blind 2Status Blind1 ByteDPT.21CRT
60Blind 2Status Communication error blind1 BitDPT.1CRT
61Blind 2Status Blind error1 ByteDPT.21CRT
70Blind 3Up/Down1 BitDPT.1CW
71Blind 3Stop/Step1 BitDPT.1CW
72Blind 3Slat tilting4 BitDPT.3CW
73Blind 3Height1 ByteDPT.5CW
74Blind 3Slat angle1 ByteDPT.5CW
75Blind 3Position combined3 BytesDPT.240CW
76Blind 3Scene activate1 ByteDPT.17CW
77Blind 3Disable manual control commands1 BitDPT.1CW
78Blind 3Up/Down (automatic)1 BitDPT.1CW
79Blind 3Height (automatic)1 ByteDPT.5CW
80Blind 3Slat angle (automatic)1 ByteDPT.5CW
81Blind 3Position combined (automatic)3 BytesDPT.240CW
82Blind 3Automatic1 BitDPT.1CW
83Blind 3Status Automatic1 BitDPT.1CRT
84Blind 3Reference movement1 BitDPT.1CW
85Blind 3Disable blind1 BitDPT.1CW
86Blind 3Status Height1 ByteDPT.5CRT
87Blind 3Status Slat angle1 ByteDPT.5CRT
88Blind 3Status Position combined3 BytesDPT.240CRT
89Blind 3Status Blind1 ByteDPT.21CRT
90Blind 3Status Communication error blind1 BitDPT.1CRT
91Blind 3Status Blind error1 ByteDPT.21CRT
100Blind 4Up/Down1 BitDPT.1CW
101Blind 4Stop/Step1 BitDPT.1CW
102Blind 4Slat tilting4 BitDPT.3CW
103Blind 4Height1 ByteDPT.5CW
104Blind 4Slat angle1 ByteDPT.5CW
105Blind 4Position combined3 BytesDPT.240CW
106Blind 4Scene activate1 ByteDPT.17CW
107Blind 4Disable manual control commands1 BitDPT.1CW
108Blind 4Up/Down (automatic)1 BitDPT.1CW
109Blind 4Height (automatic)1 ByteDPT.5CW
110Blind 4Slat angle (automatic)1 ByteDPT.5CW
111Blind 4Position combined (automatic)3 BytesDPT.240CW
112Blind 4Automatic1 BitDPT.1CW
113Blind 4Status Automatic1 BitDPT.1CRT
114Blind 4Reference movement1 BitDPT.1CW
115Blind 4Disable blind1 BitDPT.1CW
116Blind 4Status Height1 ByteDPT.5CRT
117Blind 4Status Slat angle1 ByteDPT.5CRT
118Blind 4Status Position combined3 BytesDPT.240CRT
119Blind 4Status Blind1 ByteDPT.21CRT
120Blind 4Status Communication error blind1 BitDPT.1CRT
121Blind 4Status Blind error1 ByteDPT.21CRT
Parameters (44)
ParameterTypeDefault
ST3134 KNX Blind Actuator SC 4-foldpicture
PID_HARDWARE_TYPE_PARAMETERlist
Addressing of blindslistAutomatic blind addressing
Number of connected blindslist4 (Blinds 1 - 4)
Transmission of status positionliston change (only target positions) and cyclic
Transmission of status blindliston change and cyclic
Transmission interval for cyclic transmissionunsignedInt 1…25560
Transmission interval during changesunsignedInt 1…6010
Movement after full tiltinglistYes
Enable tilting during active disable manual control commands objectlistNo
Stop on activation of disable manual control commands objectlistNo
Enable tilting during active disable blind objectlistNo
Stop on activation of disable blind objectlistYes
Follow-up on deactivation of disable blind objectlistNo
Position definition for value control (height/slat angle)listH:0=Up 100=Down / A:0=turned 100=closed
Security positionlistDisabled
Follow-up on deactivation of securitylistNo
Monitoring time security objectunsignedInt 0…2550
Scene 1 HeightunsignedInt 0…100100
Scene 1 Slat angleunsignedInt 0…100100
Scene 2 HeightunsignedInt 0…100100
Scene 2 Slat angleunsignedInt 0…10075
Scene 3 HeightunsignedInt 0…100100
Scene 3 Slat angleunsignedInt 0…10050
Scene 4 HeightunsignedInt 0…100100
Scene 4 Slat angleunsignedInt 0…1000
Scene 5 HeightunsignedInt 0…10075
Scene 5 Slat angleunsignedInt 0…100100
Scene 6 HeightunsignedInt 0…10075
Scene 6 Slat angleunsignedInt 0…10075
Scene 7 HeightunsignedInt 0…10075
Scene 7 Slat angleunsignedInt 0…10050
Scene 8 HeightunsignedInt 0…1000
Scene 8 Slat angleunsignedInt 0…1000
Deactivation by manual operationlistYes
Time until reactivation of automatic after deactivation by manual operationunsignedInt 0…1440120
Time until reactivation of automatic after deactivation by automatic objectunsignedInt 0…1440120
Polarity of auto objectlist0=Manual / 1=Automatic
Blind 1 automatic enablelistNo
Blind 2 automatic enablelistNo
Blind 3 automatic enablelistNo
Blind 4 automatic enablelistNo
Blind connectionlistPermanent connection
Referencing methodlistStandard (UP/DOWN resp. DOWN for tilt only)

Version history

ApplicationApp noFingerprintFirst seenSizeFile
ST3134 KNX Blind Actuator SC 4-fold 1.0 latest$613161CC2026-11-25143 KBDownload

About this file

This is the official ETS product database for the CONTROLtronic ST3134 KNX Blind Actuator SC 4-fold (ST3134), published by the manufacturer in the KNX online catalog. To use it, open ETS, go to Catalogs → Import and choose the downloaded .knxprod file. The device then appears in your catalog and can be added to a project. Older versions are kept so existing projects can be matched to the application program they were commissioned with.

More from CONTROLtronic

All CONTROLtronic products