KNX_2 HVAC PANEL SC-KS1-1
Citron · Order number SC-KS1-1 · HVAC PANEL
Download .knxprod APSCKS1_1 0.1 · 116 KB
Product
| Manufacturer | Citron |
|---|---|
| Product name | KNX_2 HVAC PANEL |
| Order number | SC-KS1-1 |
| Product text | SC-KS1-1 |
| Hardware | KNX_2 HVAC PANEL |
| Medium | Twisted Pair |
| Bus current (mA) | 15 |
| Rail mounted | No |
| Registration | Certified · 2024-08-19 |
| Languages | en-US |
| Catalog entry | M-0186_H-01D40001020A-0_HP-08A2-01-3381_CI-SC.2DKS1.2D1-16 |
| Fingerprint | 3381 |
| SHA-256 | e440c017a16b8ee7f2ad1e5e09f315d73bcba82c4fb075082b967a2cc5822cd8 |
| First seen | 2026-11-25 |
| Markets | China |
Application program: APSCKS1_1 0.1
| Application number | $08A2 |
|---|---|
| Version | 0.1 |
| Mask version | MV-0025 (2.5) |
| KNX Data Secure | No |
| Minimum ETS version | 5.0 |
| Parameters | 73 |
| Group objects | 26 |
Group objects (26)
| No | Name | Function | Size | DPT | Flags |
|---|---|---|---|---|---|
| 0 | HVAC Power On/Off | HVAC | 1 Bit | 1.1 switch | CRWTU |
| 1 | HVAC Power On/Off Status | HVAC | 1 Bit | 1.1 switch | CRWTU |
| 2 | HVAC control mode | 1 Byte | 20.105 HVAC control mode | CRWTU | |
| 3 | HVAC control mode status | 1 Byte | 20.105 HVAC control mode | CRWTU | |
| 4 | HVAC operation mode | 1 Byte | 20.102 HVAC mode | CRWTU | |
| 5 | HVAC operation mode status | 1 Byte | 20.102 HVAC mode | CRWU | |
| 6 | Setpoint temperature | 2 Bytes | 9.1 temperature (°C) | CRWTU | |
| 7 | Room temperature | 2 Bytes | 9.1 temperature (°C) | CRWTU | |
| 8 | External acutual temperatur | External KNX sensor | 2 Bytes | 9.1 temperature (°C) | CRWTU |
| 9 | Low speed | 1 Bit | 1.1 switch | CRWTU | |
| 10 | Middle speed | 1 Bit | 1.1 switch | CRWTU | |
| 11 | Hight speed | 1 Bit | 1.1 switch | CRWTU | |
| 12 | Fan speed | 1 Byte | 5.100 fan stage (0..255) | CRWTU | |
| 13 | Fan speed status | 1 Byte | 5.100 fan stage (0..255) | CRWTU | |
| 14 | Auto fan speed | 0:Auto; 1:Manual | 1 Bit | 1.3 enable | CRWTU |
| 15 | Continuous fan speed | 1 Byte | 5.1 percentage (0..100%) | CRWTU | |
| 16 | Continuous fan speed status | 1 Byte | 5.1 percentage (0..100%) | CRWTU | |
| 17 | Over-heating protection alarm | 1 Bit | 1.5 alarm | CRWTU | |
| 18 | Switchover value | 1 Byte | 5.4 percentage (0..255%) | CRWTU | |
| 19 | Valve Control | 1 Bit | 1.1 switch | CRWTU | |
| 19 | Cooling valve control | 1 Bit | 1.1 switch | CRWTU | |
| 20 | Heating valve control | 1 Bit | 1.1 switch | CRWTU | |
| 21 | Heating-floor Power On/Off | 1 Bit | 1.1 switch | CRWTU | |
| 22 | Heating-floor Power On/Off Status | 1 Bit | 1.1 switch | CRWTU | |
| 23 | Heating-floor actuator | 1 Bit | 1.1 switch | CRWTU | |
| 24 | HVAC Scene | 1 Byte | 18.1 scene control | CRWU |
Parameters (55)
| Parameter | Type | Default |
|---|---|---|
| @Copyright Citron 2022 Version 2.00 HVAC Control Panel Series www.citron-iot.com [email protected] | text | |
| Time to return inactive state from active state | list | 15 S |
| Time to exit setting with saving | list | 15 S |
| External KNX temperature sensor | list | Disable |
| Weight of inter/exter Temp. sensor | list | 100% internal sensor |
| Minimum backlight intensity during inactive state | list | Level 3 |
| the mode of the fan-coil system | list | 2 Pipes |
| the type of the control mode datapoint | list | User-defined |
| the data for the heat-mode | unsignedInt 0…255 | 1 |
| the data for the cool-mode | unsignedInt 0…255 | 3 |
| the data for the only ventilation-mode | unsignedInt 0…255 | 9 |
| the data for the dehumidify-mode | unsignedInt 0…255 | 14 |
| the data for the power off mode | unsignedInt 0…255 | 6 |
| Ventilation control type | list | 3 speeds |
| data for low-speed | unsignedInt 0…255 | 0 |
| data for mid-speed | unsignedInt 0…255 | 0 |
| data for hi-speed | unsignedInt 0…255 | 0 |
| Fan speed proportional[0.1K] | unsignedInt 5…100 | 20 |
| Min. change of value to send[%] | unsignedInt 2…40 | 15 |
| Need to stop the fancoil or not when the S.T. = R.T. | list | No |
| the type of datapoint for operation mode | list | User-defined |
| Comfort temp. setpoint [℃] | unsignedInt 10…30 | 23 |
| Standby temp. setpoint [℃] | unsignedInt 10…30 | 29 |
| Economy temp. setpoint [℃] | unsignedInt 10…30 | 26 |
| the data for the comfort mode | unsignedInt 0…255 | 1 |
| the data for the standby mode | unsignedInt 0…255 | 2 |
| the data for the economy mode | unsignedInt 0…255 | 3 |
| Comfort temp. setpoint [℃] | unsignedInt 2…26 | 25 |
| Standby temp. setpoint [℃] | unsignedInt 2…26 | 10 |
| Economy temp. setpoint [℃] | unsignedInt 2…26 | 16 |
| Over-heating protection for electronic heating floor | list | Disable |
| Over-heating protection temp. [℃] | unsignedInt 32…36 | 35 |
| Command switching to Airconditioner mode from bus | unsignedInt 0…255 | 0 |
| Command switching to heating-floor mode from bus | unsignedInt 0…255 | 0 |
| Command switching to both cool and heating mode from bus | unsignedInt 0…255 | 0 |
| data for stop fancoil | unsignedInt 0…255 | 0 |
| Send temperature data to bus | list | Disable |
| Whether send data to bus periodically | list | No |
| Time to send temperature to bus in cycles(Seconds) | unsignedInt 10…1800 | 60 |
| Scene 1 | list | Disable |
| Scene 2 | list | Disable |
| Scene 3 | list | Disable |
| Scene 4 | list | Disable |
| Scene 5 | list | Disable |
| Scene 6 | list | Disable |
| Scene 7 | list | Disable |
| Scene 8 | list | Disable |
| Scene number | unsignedInt 1…64 | 1 |
| HVAC Mode | list | Comfort |
| Operation mode | list | not depending on the temperature |
| data for fanspeed 1 | unsignedInt 0…100 | 20 |
| data for fanspeed 2 | unsignedInt 0…100 | 40 |
| data for fanspeed 3 | unsignedInt 0…100 | 60 |
| data for fanspeed 4 | unsignedInt 0…100 | 80 |
| data for fanspeed 5 | unsignedInt 0…100 | 100 |
Version history
| Application | App no | Fingerprint | First seen | Size | File |
|---|---|---|---|---|---|
| APSCKS1_1 0.1 latest | $08A2 | 3381 | 2026-11-25 | 116 KB | Download |
About this file
This is the official ETS product database for the Citron KNX_2 HVAC PANEL (SC-KS1-1), published by the manufacturer in the KNX online catalog. To use it, open ETS, go to Catalogs → Import and choose the downloaded .knxprod file. The device then appears in your catalog and can be added to a project. Older versions are kept so existing projects can be matched to the application program they were commissioned with.