V600 Room Thermostat V600

CARRIER SAS · Order number V600 · Heating, Ventilation, Air Conditioning › Room Thermostats

Room Thermostat Controller

Download .knxprod V600 1.0 · 213 KB

Product

ManufacturerCARRIER SAS
Product nameV600 Room Thermostat
Order numberV600
HardwareHardwareEntry.0.0003
MediumTwisted Pair
Bus current (mA)5
Rail mountedYes
RegistrationRegistered · 2025-05-19
Languagesen-US, fr-FR, de-DE
Catalog entryM-007E_H-V600-1-O00FD_HP-0003-10-92D2-O00FD_CI-V600-1
Fingerprint92D2
SHA-256282a06819c52ebc0b1855da1d2317f8ef428a3c3cda10ccd4ed29c692199073a
First seen2026-11-25
MarketsFrance

Application program: V600 1.0

Application number$0003
Version1.0
Mask versionMV-07B0 (System B)
KNX Data SecureNo
Minimum ETS version5.0
Parameters149
Group objects109
Group objects (109)
NoNameFunctionSizeDPTFlags
1System timeReceive8 Bytes19.1 date timeCWU
2DateReceive3 Bytes11.1 dateCWU
3Time of dayReceive3 Bytes10.1 time of dayCWU
4Fault informationSend6 Bytes219.1 alarm infoCRT
5Fault state (0=Normal/1=Fault)Send1 Bit1.5 alarmCRT
6Fault transmission (0=Disable/1=Enable)Receive1 Bit1.3 enableCWU
7Room operating mode: PreselectionReceive1 Byte20.102 HVAC modeCWU
8Room operating mode: PreselectionSend1 Byte20.102 HVAC modeCRT
9Room operating mode: Preselection AutoReceive1 Bit1.17 triggerCW
10Room operating mode: Preselection ComfortReceive1 Bit1.17 triggerCW
11Room operating mode: Preselection EconomyReceive1 Bit1.17 triggerCW
12Room operating mode: Preselection ProtectionReceive1 Bit1.17 triggerCW
13Room operating mode: SchedulerReceive1 Byte20.102 HVAC modeCWU
14Room operating mode: Scheduler ComfortReceive1 Bit1.17 triggerCW
15Room operating mode: Scheduler EconomyReceive1 Bit1.17 triggerCW
16Room operating mode: Scheduler ProtectionReceive1 Bit1.17 triggerCW
17Room operating mode stateSend1 Byte20.102 HVAC modeCRT
18Room operating mode state: ComfortSend1 Bit1.11 stateCRT
19Room operating mode state: EconomySend1 Bit1.11 stateCRT
20Room operating mode state: ProtectionSend1 Bit1.11 stateCRT
21Room temp: [P19] Heating setpoint EconomyReceive2 Bytes9.1 temperature (°C)CW
22Room temp: [P20] Cooling setpoint EconomyReceive2 Bytes9.1 temperature (°C)CW
23Room operating mode: Window contact (0=Close/1=Open)Receive1 Bit1.19 window/doorCWU
24Room operating mode: Presence detector (0=Unoccupied/1=Occupied)Receive1 Bit1.18 occupancyCWU
25Room temp: Basic setpoint ComfortReceive2 Bytes9.1 temperature (°C)CWU
26Room temp: Abs. setpoint ComfortReceive2 Bytes9.1 temperature (°C)CWU
27Room temp: Abs. setpoint ComfortSend2 Bytes9.1 temperature (°C)CRT
28Room temp: Current setpointSend2 Bytes9.1 temperature (°C)CRT
29Setpoint heating setReceive8 Bytes275.100 Temperature setpoint setting for 4 HVAC ModesCW
30Setpoint cooling setReceive8 Bytes275.100 Temperature setpoint setting for 4 HVAC ModesCW
31Setpoint heating setSend8 Bytes275.100 Temperature setpoint setting for 4 HVAC ModesCRT
32Setpoint cooling setSend8 Bytes275.100 Temperature setpoint setting for 4 HVAC ModesCRT
33Room temperature: Rel. setpoint ComfortReceive2 Bytes9.2 temperature difference (K)CWU
34Room temperature: Rel. setpoint ComfortSend2 Bytes9.2 temperature difference (K)CRT
35Extended comfort mode stateSend1 Bit1.11 stateCRT
36External room temperature valueReceive2 Bytes9.1 temperature (°C)CWU
37Built-in room temperature valueSend2 Bytes9.1 temperature (°C)CRT
38Frost alarm (0=Normal/1=Alarm)Send1 Bit1.5 alarmCRT
39Heat alarm (0=Normal/1=Alarm)Send1 Bit1.5 alarmCRT
40X1: Temperature [°C]Send2 Bytes9.1 temperature (°C)CRT
41X1: Digital [0/1]Send1 Bit1.1 switchCRT
42X2: Temperature [°C]Send2 Bytes9.1 temperature (°C)CRT
43X2: Digital [0/1]Send1 Bit1.1 switchCRT
44U1: Temperature [°C]Send2 Bytes9.1 temperature (°C)CRT
45U1: Digital [0/1]Send1 Bit1.1 switchCRT
46Heating/Cooling changeover (1=Heating/0=Cooling)Receive1 Bit1.100 cooling/heatingCWU
47Heating/Cooling mode state (1=Heating/0=Cooling)Send1 Bit1.100 cooling/heatingCRT
48Application modeReceive1 Byte20.105 HVAC control modeCWU
49Dew point alarm (0=Normal/1=Alarm)Receive1 Bit1.5 alarmCWU
50Enable fan command (0=Disable/1=Enable)Receive1 Bit1.3 enableCWU
51Fan operation (0=Auto/1=Manual)Send1 Bit1.1 switchCRT
52Fan speedReceive1 Byte5.1 percentage (0..100%)CWU
53Fan outputSend1 Byte5.1 percentage (0..100%)CRT
54Fan speed 1 (0=Off/1=On)Receive1 Bit1.1 switchCWU
55Fan speed 2 (0=Off/1=On)Receive1 Bit1.1 switchCWU
56Fan speed 3 (0=Off/1=On)Receive1 Bit1.1 switchCWU
57Fan speed 1 (0=Off/1=On)Send1 Bit1.1 switchCRT
58Fan speed 2 (0=Off/1=On)Send1 Bit1.1 switchCRT
59Fan speed 3 (0=Off/1=On)Send1 Bit1.1 switchCRT
60Outside temperatureReceive2 Bytes9.1 temperature (°C)CWU
61Heating, control value continuousSend1 Byte5.1 percentage (0..100%)CRT
62Heating, control value continuous, seq 2Send1 Byte5.1 percentage (0..100%)CRT
63Cooling, control value continuousSend1 Byte5.1 percentage (0..100%)CRT
64Cooling, control value continuous, seq 2Send1 Byte5.1 percentage (0..100%)CRT
65Heating, control value state (0=Off/1=On)Send1 Bit1.11 stateCRT
66Heating, control value state seq 2 (0=Off/1=On)Send1 Bit1.11 stateCRT
67Cooling, control value state (0=Off/1=On)Send1 Bit1.11 stateCRT
68Cooling, control value state seq 2 (0=Off/1=On)Send1 Bit1.11 stateCRT
69Heating and cooling, control value state (0=Off/1=On)Send1 Bit1.11 stateCRT
70Heating and cooling, control value state seq2 (0=Off/1=On)Send1 Bit1.11 stateCRT
71Heating and cooling, control value continuousSend1 Byte5.1 percentage (0..100%)CRT
72Heating and cooling, control value continuous seq 2Send1 Byte5.1 percentage (0..100%)CRT
73Control dehumidification (1=On/0=Off)Send1 Bit1.11 stateCRT
74Control humidification (1=On/0=Off)Send1 Bit1.11 stateCRT
75Hum. Control mode (inactive/hum/dehum)Send1 Byte20.115 hum dehum modeCRT
76Enable electric heater (0=Disable/1=Enable)Receive1 Bit1.3 enableCWU
77Built-in room relative humidity value [%r.H.]Send2 Bytes9.7 humidity (%)CRT
78External room relative humidity value [%r.H.]Receive2 Bytes9.7 humidity (%)CWU
79Room rel. humidity: Setpoint highReceive2 Bytes9.7 humidity (%)CWU
80Room rel. humidity: Setpoint lowReceive2 Bytes9.7 humidity (%)CWU
81Reset energy efficiency state (Green leaf)Receive1 Bit1.17 triggerCWU
82Energy efficiency state / Green Leaf (0=Green/1=Red)Send1 Bit1.6 binary valueCRT
83Enable/disable Leaf indication (0=Disable/1=Enable)Receive1 Bit1.3 enableCWU
84Keypad: Lock fan speedReceive1 Bit1.2 booleanCWU
85Keypad: Lock fan speed in “auto” modeReceive1 Bit1.2 booleanCWU
86Keypad: Lock the setpoint shiftReceive1 Bit1.2 booleanCWU
87Keypad: Lock the operating modeReceive1 Bit1.2 booleanCWU
88Room operating mode: Presence detector (0=Unoccupied/1=Occupied)Send1 Bit1.18 occupancyCRT
89Room operating mode: Window contact (0=Close/1=Open)Send1 Bit1.19 window/doorCRT
90Room temp: Current cooling setpointSend2 Bytes9.1 temperature (°C)CRT
91Room temp: Current heating setpointSend2 Bytes9.1 temperature (°C)CRT
92Room temp: Current heating setpointReceive2 Bytes9.1 temperature (°C)CWU
93Room temp: Current cooling setpointReceive2 Bytes9.1 temperature (°C)CWU
94Room operating mode: StateReceive1 Byte20.102 HVAC modeCWU
95Changeover water state (1=Heating/0=Cooling)Send1 Bit1.100 cooling/heatingCRT
96Changeover water state (1=Heating/0=Cooling)Receive1 Bit1.100 cooling/heatingCWU
97Manual fan commandSend1 Byte5.1 percentage (0..100%)CRT
98DC fan speed: [P359] Maximum speed heatingReceive1 Byte5.1 percentage (0..100%)CWU
99DC fan speed: [P360] Maximum speed coolingReceive1 Byte5.1 percentage (0..100%)CWU
100Built-in room air quality valueSend2 Bytes9.8 parts/million (ppm)CRT
101External room air quality valueReceive2 Bytes9.8 parts/million (ppm)CWU
102Damper demand [%]Send1 Byte5.1 percentage (0..100%)CRT
103Damper demand (0=Off/1=On)Send1 Bit1.1 switchCRT
104PICV: [P260] Heating maximum positionReceive1 Byte5.1 percentage (0..100%)CWU
105PICV: [P261] Cooling maximum positionReceive1 Byte5.1 percentage (0..100%)CWU
106Room rel. humidity: [P025] Setpoint high EcoReceive2 Bytes9.7 humidity (%)CWU
107[P023] Room air quality: Setpoint [ppm]Receive2 Bytes9.8 parts/million (ppm)CWU
108[P455] Minimum damper position [%]Receive1 Byte5.1 percentage (0..100%)CWU
109[P457] Maximum damper position [%]Receive1 Byte5.1 percentage (0..100%)CWU
Parameters (139)
ParameterTypeDefault
[DIP] Plant typelist---
[P350] Fan controllistEnabled
[P001] Control sequencelistCooling only
[P001] Control sequencelistHeating and cooling
[P201] Output Y1 (and Y3 for 3-pos.)listOn/off
[P203] Output Y2 (and Y4 for 3-pos.)listOn/off
[P204] Output Y3listOn/off
[P205] Output Y4listOn/off
[P150] Input X1listRoom / Return temperature
[P153] Input X2list---
[P155] Input U1listWindow contact (DI)
[P450] Control strategylistTemperature (T)
[P450] Control strategylistTemperature (T)
[P258] Manager / SubordinatelistManager
Preselection reception: Com. Objlist---
Scheduler reception: Com. Objlist---
State transmission: Com. Objlist---
Room temperature: Economy SetpointlistAs parameters only
Window state inputlistLocal
Presence detector inputlistLocal
Room temperature: Comfort Basic SetpointlistDisabled
Room temperature: Comfort SetpointlistDisabled
Room temperature: Current SetpointlistDisabled
Room temperature: Setpoint sets, receivelistDisabled
Room temperature: Setpoint sets, sendlistDisabled
State Object for extended comfort modelistYes
Frost AlarmlistDisabled
Overheating alarmlistDisabled
Application mode inputlistDisabled
Dewpoint alarmlistDisabled
Humidity setpointslistAs parameters only
[P259] Subordinate identificationlist1
[P005] SchedulerlistDisabled
[P002] Operation via room operating mode selectorlistAuto - Comfort - Protection
[P002] Operation via room operating mode selectorlistAuto - Protection
[P003] Operation via fan operating selectorlistAuto - Manual
[P004] UnitlistDegrees Celsius
[P008] Standard displaylistRoom temperature
[P009] Additional display informationlist---
[P017] Summer timelistEurope
[P028] KeypadlistUnlocked
[P030] Buzzer functionlistEnabled
[P031] LanguagelistEnglish
[P032] Room operating mode holidayslistEconomy
[P500] NFClistEnabled
[P502] PasswordlistDisabled
[P503] PasswordunsignedInt 0…9990
[P910] Transformation PrecomfortlistEconomy
Presence detector functionlistStandard
[P102] Temporary Comfort mode [min]list------
[P010] Setpoint conceptlistComfort concept
[P011] Comfort basic setpoint [°C]list21.0°C
[P104] Setpoint displaylistAbsolute setpoints
[P019] Economy heating setpoint [°C]list15.0°C
[P020] Economy cooling setpoint [°C]list30.0°C
[P100] Protection heating setpoint [°C]list8.0°C
[P101] Protection cooling setpoint [°C]list-------
[P013] Comfort setpoint minimum [°C]list5.0°C
[P016] Comfort setpoint maximum [°C]list35.0°C
[P014] Comfort setpoint maximum Heating [°C]list21.0°C
[P015] Comfort setpoint minimum Cooling [°C]list25.0°C
[P103] Temporary Comfort setpointlistDisabled
[P451] Humidity control strategylistWith setpoint shift + external equipment (humid / dehum)
[P461] Temp setpoint shift (humidity) [K]list3.0 K
[P024] Humidity setpoint high [%]list50%
[P025] Humidity setpoint high Eco [%]list---
[P026] Humidity setpoint low [%]list---
[P109] Outside damper frost protectionlist---
[P455] Minimum damper position [%]unsignedInt 0…1000
[P457] Maximum damper position [%]unsignedInt 0…100100
[P458] Fan during damper controllistEnabled
[P027] Electric heater when coolinglistEnabled
[P200] Number of heating / cooling sequenceslist2 sequence heating, 2 sequence cooling
[P050] Heating P-band Xp [K]list2.0 K
[P057] Integral action time Tn heating [minutes]unsignedInt 0…12045
[P052] Cooling P-band Xp [K]list1.0 K
[P058] Integral action time Tn cooling [minutes]unsignedInt 0…12045
[P051] Switching differential heating [K]list1.0 K
[P053] Switching differential cooling [K]list1.0 K
[P055] Dead zone Comfort mode [K]list2.0 K
[P056] Setpoint differential [K]list2.0 K
[P054] Radiator P-band Xp/switching differential [K]list2.0 K
[P059] H/C changeover switching point cooling [°C]list16.0°C
[P060] H/C changeover switching point heating [°C]list28.0°C
[P061] Return temp limit delta coollist-------
[P062] Return temp limit delta heatlist-------
[P063] Minimum supply air temperature [°C]list---
[P064] Maximum supply air temperature [°C]list---
[P110] Energy indicatorlistGreen and Red dimmed out
[P111] Energy indicator range [K]list2.0 K
[P250] Valve kicklistDisabled
[P251] Purge time (every 2 hours) [minutes]list-------
[P252] Flow temp limit floor heating [°C]list28.0°C
[P254] Swap sequence H and C (2-pipe/2-stage)listDisabled
[P255] Track cooling setpoint on outside temperaturelistDisabled
Threshold for frost alarm [°C]list5.0°C
Threshold value overheating [°C]list40.0°C
[P006] Measured value correction [K]list0.0 K
[P007] Humidity value correction [%]list0%
[P151] Sensor input X1listNTC 3K
[P151] Normal position X1listOpen
[P151] Normal position or sensor input X1listNTC 3K
[P154] Sensor input X2listNTC 3K
[P154] Normal position X2listOpen
[P154] Normal position or sensor input X2listOpen
[P156] Sensor input U1listNTC 3K
[P156] Normal position U1listOpen
[P156] Normal position or sensor input U1listOpen
[P206] PWM algorithm cycle Y1 [seconds]unsignedInt 20…36001200
[P207] PWM algorithm cycle Y2 [seconds]unsignedInt 20…36001200
[P208] PWM algorithm cycle Y3 [seconds]unsignedInt 20…36001200
[P209] PWM algorithm cycle Y4 [seconds]unsignedInt 20…36001200
[P210] On time minimum PWM output [%]unsignedInt 1…205
[P211] Off time minimum PWM output [%]unsignedInt 1…205
[P212] On time minimum 2-pos output [minutes]unsignedInt 1…201
[P213] Off time minimum 2-pos output [minutes]unsignedInt 1…201
[P214] Actuator run time Y1 and Y3 for 3-pos [seconds]unsignedInt 20…300150
[P215] Actuator run time Y2 and Y4 for 3-pos [seconds]unsignedInt 20…300150
[P400] Output Q1 functionlist---
[P401] Output Q2 functionlist---
[P402] Output Q3 functionlist---
[P351] Fan speedslistDC 0...10 V (DC fan)
[P352] Fan overrun time [seconds]unsignedInt 0…60060
[P029] Fan: Dead zone Comfort modelistOff
[P353] Fan speed switching point low (value in %)unsignedInt 1…10010
[P361] Fan start kicklistEnabled
[P354] Fan speed switching point med (value in %)unsignedInt 1…10065
[P355] Fan speed switching point high (value in %)unsignedInt 1…100100
[P356] DC fan switching point [%]unsignedInt 1…10010
[P357] DC fan speed low min. output [%]unsignedInt 1…10030
[P358] DC fan speed med. output [%]unsignedInt 1…10060
[P359] DC fan speed high max. out. heat [%]unsignedInt 1…10080
[P360] DC fan speed high max. out. cool [%]unsignedInt 1…10080
[P362] On time minimum fan [minutes]unsignedInt 1…62
[P363] Periodic fan kick Comfort [minutes]list-------
[P364] Periodic fan kick Economy [minutes]list-------
[P365] Fan start delay [seconds]unsignedInt 0…3600
[P366] Fan start, minimum hot water temperature [°C]list30.0°C
[P501] Service filter [hour]list-------

Version history

ApplicationApp noFingerprintFirst seenSizeFile
V600 1.0 latest$000392D22026-11-25213 KBDownload

About this file

This is the official ETS product database for the CARRIER SAS V600 Room Thermostat (V600), published by the manufacturer in the KNX online catalog. To use it, open ETS, go to Catalogs → Import and choose the downloaded .knxprod file. The device then appears in your catalog and can be added to a project. Older versions are kept so existing projects can be matched to the application program they were commissioned with.