KNX Database

2-fold input, battery, embedded 85876210

Berker · Order number 85876210 · RF devices › Inputs

8587 62 10 Quicklink

Download .knxprod 85876210 1.0 · 479 KB

Product

ManufacturerBerker
Product name2-fold input, battery, embedded
Order number85876210
Hardware85876210
MediumTwisted Pair
Bus current (mA)1
Rail mountedNo
RegistrationRegistered · 2016-11-28
Languagesfr-FR, de-DE, it-IT, nl-NL, pt-PT, nb-NO, sv-SE
Catalog entryM-0006_H-6.20.2F.2F.2085876210-1-O0009_HP-D03E-10-C917-O0009_CI-85876210-1
FingerprintC917
SHA-256a050705057eefbb4968e61ae04ddd519a0faa2a7a40285810ca67f90a8aaa054
First seen2026-11-25
Markets69 markets

Application program: 85876210 1.0

Application number$D03E
Version1.0
Mask versionMV-0701 (7.1)
KNX Data SecureNo
Minimum ETS version4.0
Parameters483
Group objects47
Group objects (47)
NoNameFunctionSizeDPTFlags
0Input 1Status indication ON/OFF1 Bit1.1 switchCRW
1Input 1Automatic control deactivation1 Bit1.3 enableCRT
1Input 1Load shedding1 Bit1.2 booleanCRT
1Input 1Alarm 31 Bit1.5 alarmCRT
1Input 1Heating/Cooling - changeover1 Bit1.100 heating/coolingCRT
1Input 1ON/OFF1 Bit1.1 switchCRT
1Input 1Alarm 21 Bit1.5 alarmCRT
1Input 1Timer1 Bit1.10 start/stopCRT
1Input 1Up/down1 Bit1.8 up/downCRT
1Input 1Alarm 11 Bit1.5 alarmCRT
1Input 1Windows contact status1 Bit1.19 window/doorCRT
2Input 1Step/stop (short press)1 Bit1.7 stepCRT
2Input 1Stop (short press)1 Bit1.17 triggerCRT
3Input 1Priority2 Bit2.2 boolean controlCRT
4Input 1Dimming4 Bit3.7 dimming controlCRT
5Input 1Brightness value1 Byte5.1 percentage (0..100%)CRT
5Input 1Setpoint selection1 Byte20.102 HVAC modeCRT
5Input 1Position in %1 Byte5.1 percentage (0..100%)CRT
5Input 1Scene1 Byte18.1 scene controlCRT
5Input 1Current tariff1 Byte5.6 tariff (0..255)CRT
6Input 1Slat angle in %1 Byte5.1 percentage (0..100%)CRT
8Input 1Upper position reached1 Bit1.2 booleanCRW
9Input 1Lower position reached1 Bit1.2 booleanCRW
10Input 2Status indication ON/OFF1 Bit1.1 switchCRW
11Input 2Automatic control deactivation1 Bit1.3 enableCRT
11Input 2Load shedding1 Bit1.2 booleanCRT
11Input 2Alarm 31 Bit1.5 alarmCRT
11Input 2Heating/Cooling - changeover1 Bit1.100 heating/coolingCRT
11Input 2ON/OFF1 Bit1.1 switchCRT
11Input 2Alarm 21 Bit1.5 alarmCRT
11Input 2Timer1 Bit1.10 start/stopCRT
11Input 2Up/down1 Bit1.8 up/downCRT
11Input 2Alarm 11 Bit1.5 alarmCRT
11Input 2Windows contact status1 Bit1.19 window/doorCRT
12Input 2Step/stop (short press)1 Bit1.7 stepCRT
12Input 2Stop (short press)1 Bit1.17 triggerCRT
13Input 2Priority2 Bit2.2 boolean controlCRT
14Input 2Dimming4 Bit3.7 dimming controlCRT
15Input 2Brightness value1 Byte5.1 percentage (0..100%)CRT
15Input 2Setpoint selection1 Byte20.102 HVAC modeCRT
15Input 2Position in %1 Byte5.1 percentage (0..100%)CRT
15Input 2Scene1 Byte18.1 scene controlCRT
15Input 2Current tariff1 Byte5.6 tariff (0..255)CRT
16Input 2Slat angle in %1 Byte5.1 percentage (0..100%)CRT
18Input 2Upper position reached1 Bit1.2 booleanCRW
19Input 2Lower position reached1 Bit1.2 booleanCRW
20Status indicationBattery status1 Bit1.11 stateCRT
Parameters (172)
ParameterTypeDefault
newstyle|inputtextBidir Config ConfProp
Application software versiontext1.0.4
Descriptionlist
85876210_ETS_1033.pdflist
img\85876210.jpglist
Channel functionlistNot active
dummylistTECH_Toggle
FONCTION_E1_AJS TogglelistTECH_No function
dummylistTECH_No function
FONCTION_E1_AJS_SWITCHINGlistTECH_Switch
Fonction_E1 switchinglistTECH_Switch
FONCTION_E1_P1_SWITCHING_FUNCTION_2_ONlistON
FONCTION_E1_P2_SWITCHING_FUNCTION_2_ONlistON
Using modelistON/OFF
FONCTION_E1_P1_SWITCHING_FUNCTION_2_OFFlistOFF
FONCTION_E1_P2_SWITCHING_FUNCTION_2_OFFlistOFF
InvertedunsignedInt 0…10
FONCTION_E1_P5_SWITCHING_E1_E2_INVunsignedInt 0…2552
FONCTION_E1_P5_SWITCHING_E1_E2_INVunsignedInt 0…2556
FONCTION_E1_P5_SWITCHING_E1_E2_INVunsignedInt 0…2551
FONCTION_E1_P5_SWITCHING_E1_E2_INVunsignedInt 0…2555
FONCTION_E1_P5_SWITCHING_E1_E2_INVunsignedInt 0…2553
FONCTION_E1_P5_SWITCHING_E1_E2_INVunsignedInt 0…2557
FONCTION_E1_P1_SWITCHING_FUNCTION_1_PADDINGunsignedInt 0…2550
FONCTION_E1_P3_SWITCHING_FUNCTION_2_PADDINGunsignedInt 0…2550
dummylistTECH_Timer
dummylistTECH_Dimming Toggle
dummylistTECH_Dimmer
dummylistTECH_Dim Value Switch
dummylistTECH_Sunblind
dummylistTECH_Shutter
dummylistTECH_Shutter Position Switch
dummylistTECH_Slat Position Switch
dummylistTECH_Shutter and Slat Position Switch
dummylistTECH_HVAC Mode Switch
dummylistTECH_Heating Cooling Switch
dummylistTECH_Forced
dummylistTECH_Scene Switch
dummylistTECH_Automatism deactivation switch
dummylistTECH_Shutter Switch
dummylistTECH_Alarm1
dummylistTECH_Alarm2
dummylistTECH_Alarm3
dummylistTECH_Energy alarm
dummylistTECH_Window
dummylistTECH_Tariff
dummylistTECH_Scene
FONCTION_E1_P5_TARIFF_INV_0unsignedInt 0…2550
FONCTION_E1_P5_TARIFF_INV_1unsignedInt 0…2554
Closing typelistShutter
Shutter functionlist2-button shutter
Function by presslistUp
Using modelistUp/down
Using modelistFunction by press/release
Position (0-100%) by pressunsignedInt 0…100100
Position (0-100%) on releaseunsignedInt 0…1000
position 0-100 by pressunsignedInt 0…255255
position 0-100 on releaseunsignedInt 0…2550
dummyunsignedInt 0…2557
dummyunsignedInt 0…2553
dummyunsignedInt 0…2555
dummyunsignedInt 0…2551
dummyunsignedInt 0…2556
dummyunsignedInt 0…2552
FONCTION_E1_P1_SHUTTER_UPlistUp
FONCTION_E1_P1_SHUTTER_DOWNlistDown
FONCTION_E1_P5_SHUTTER_POS_E1_E2_INVunsignedInt 0…2552
FONCTION_E1_P5_SHUTTER_POS_E1_E2_INVunsignedInt 0…2556
FONCTION_E1_P5_SHUTTER_POS_E1_E2_INVunsignedInt 0…2551
FONCTION_E1_P5_SHUTTER_POS_E1_E2_INVunsignedInt 0…2555
FONCTION_E1_P5_SHUTTER_POS_E1_E2_INVunsignedInt 0…2553
FONCTION_E1_P5_SHUTTER_POS_E1_E2_INVunsignedInt 0…2557
FONCTION_E1_P1_SHUTTER_STOPlistStop
Alarm typelistAlarm 1
Scene functionlistScene 1-64
Scene number (1-64) by pressunsignedInt 1…641
Scene number (1-64) on releaseunsignedInt 1…642
Scene numberunsignedInt 0…630
Scene numberunsignedInt 0…631
FONCTION_E1_P5_SCENE_SW_E1_E2_INVunsignedInt 0…2557
FONCTION_E1_P5_SCENE_SW_E1_E2_INVunsignedInt 0…2553
FONCTION_E1_P5_SCENE_SW_E1_E2_INVunsignedInt 0…2555
FONCTION_E1_P5_SCENE_SW_E1_E2_INVunsignedInt 0…2551
FONCTION_E1_P5_SCENE_SW_E1_E2_INVunsignedInt 0…2556
FONCTION_E1_P5_SCENE_SW_E1_E2_INVunsignedInt 0…2552
Using modelistPriority ON/down/comfort
DummylistPriority ON/down/comfort
DummylistPriority OFF/up/frost protection
FONCTION_E1_P5_FORCED_INV_0unsignedInt 0…2550
FONCTION_E1_P5_FORCED_INV_1unsignedInt 0…2554
Heating functionlistSetpoint selection
FONCTION_E1_P5_HEATING_INV_0unsignedInt 0…2550
FONCTION_E1_P5_HEATING_INV_1unsignedInt 0…2554
Override setpointfloat -5…50
FONCTION_E1_P1_SETPOINT_MSBunsignedInt 0…2550
FONCTION_E1_P1_SETPOINT_LSBunsignedInt 0…2550
Set point signunsignedInt 0…2550
Set point signunsignedInt 0…655350
Setpoint by presslistComfort
Setpoint on releaselistNight setpoint
FONCTION_E1_P5_HVAC_E1_E2_INVunsignedInt 0…2552
FONCTION_E1_P5_HVAC_E1_E2_INVunsignedInt 0…2556
FONCTION_E1_P5_HVAC_E1_E2_INVunsignedInt 0…2551
FONCTION_E1_P5_HVAC_E1_E2_INVunsignedInt 0…2555
FONCTION_E1_P5_HVAC_E1_E2_INVunsignedInt 0…2553
FONCTION_E1_P5_HVAC_E1_E2_INVunsignedInt 0…2557
Dimming functionlistIncrease/decrease
Function by presslistDecrease
Brightness value on releaseunsignedInt 0…2550
Brightness value by pressunsignedInt 0…255255
Brightness value by pressunsignedInt 0…100100
Brightness value on releaseunsignedInt 0…1000
Blind functionlistUp/down/step/stop
dummylistUp
dummylistDown
dummyunsignedInt 0…2550
Slat angle (0-100%) by pressunsignedInt 0…100100
Slat angle (0-100%) on releaseunsignedInt 0…1000
dummyunsignedInt 0…255255
dummyunsignedInt 0…655350
Fonction_E2 TogglelistTECH_No function
Fonction_E2 TogglelistTECH_Toggle
FONCTION_E2_AJS TogglelistTECH_No function
Fonction_E2 switchinglistTECH_Switch
FONCTION_E2_AJS_SWITCHINGlistTECH_Switch
FONCTION_E2_P1_SWITCHING_FUNCTION_2_ONlistON
FONCTION_E2_P1_SWITCHING_FUNCTION_1_PADDINGunsignedInt 0…2550
FONCTION_E2_P2_SWITCHING_FUNCTION_2_OFFlistOFF
FONCTION_E2_P3_SWITCHING_FUNCTION_2_PADDINGunsignedInt 0…2550
FONCTION_E2_P5_SWITCHING_E2_E2_INVunsignedInt 0…2553
FONCTION_E2_P5_SWITCHING_E2_E2_INVunsignedInt 0…2557
FONCTION_E2_P5_SWITCHING_E2_E2_INVunsignedInt 0…2551
FONCTION_E2_P5_SWITCHING_E2_E2_INVunsignedInt 0…2555
FONCTION_E2_P1_SWITCHING_FUNCTION_2_OFFlistOFF
FONCTION_E2_P2_SWITCHING_FUNCTION_2_ONlistON
FONCTION_E2_P5_SWITCHING_E2_E2_INVunsignedInt 0…2552
FONCTION_E2_P5_SWITCHING_E2_E2_INVunsignedInt 0…2556
FONCTION_E2_P1_SHUTTER_UPlistUp
FONCTION_E2_P1_SHUTTER_DOWNlistDown
FONCTION_E2_P5_SHUTTER_POS_E2_E2_INVunsignedInt 0…2551
FONCTION_E2_P5_SHUTTER_POS_E2_E2_INVunsignedInt 0…2555
FONCTION_E2_P5_SHUTTER_POS_E2_E2_INVunsignedInt 0…2552
FONCTION_E2_P5_SHUTTER_POS_E2_E2_INVunsignedInt 0…2556
FONCTION_E2_P5_SHUTTER_POS_E2_E2_INVunsignedInt 0…2553
FONCTION_E2_P5_SHUTTER_POS_E2_E2_INVunsignedInt 0…2557
FONCTION_E2_P1_SHUTTER_STOPlistStop
FONCTION_E2_P5_HVAC_E2_E2_INVunsignedInt 0…2551
FONCTION_E2_P5_HVAC_E2_E2_INVunsignedInt 0…2555
FONCTION_E2_P5_HVAC_E2_E2_INVunsignedInt 0…2552
FONCTION_E2_P5_HVAC_E2_E2_INVunsignedInt 0…2556
FONCTION_E2_P5_HVAC_E2_E2_INVunsignedInt 0…2553
FONCTION_E2_P5_HVAC_E2_E2_INVunsignedInt 0…2557
FONCTION_E2_P5_HEATING_INV_0unsignedInt 0…2550
FONCTION_E2_P5_HEATING_INV_1unsignedInt 0…2554
FONCTION_E2_P1_SETPOINT_MSBunsignedInt 0…2550
FONCTION_E2_P1_SETPOINT_LSBunsignedInt 0…2550
dummylistPriority ON/down/comfort
FONCTION_E2_P5_FORCED_INV_0unsignedInt 0…2550
FONCTION_E2_P5_FORCED_INV_1unsignedInt 0…2554
dummylistPriority OFF/up/frost protection
FONCTION_E2_P5_SCENE_SW_E2_E2_INVunsignedInt 0…2551
FONCTION_E2_P5_SCENE_SW_E2_E2_INVunsignedInt 0…2555
FONCTION_E2_P5_SCENE_SW_E2_E2_INVunsignedInt 0…2552
FONCTION_E2_P5_SCENE_SW_E2_E2_INVunsignedInt 0…2556
FONCTION_E2_P5_SCENE_SW_E2_E2_INVunsignedInt 0…2553
FONCTION_E2_P5_SCENE_SW_E2_E2_INVunsignedInt 0…2557
FONCTION_E2_P5_TARIFF_INV_0unsignedInt 0…2550
FONCTION_E2_P5_TARIFF_INV_1unsignedInt 0…2554
Version of translation filelist2
dummylistTECH_SunBlind Toggle
EmissionlistOn status change
Polaritylist0 if low setpoint reached

Version history

ApplicationApp noFingerprintFirst seenSizeFile
85876210 1.0 latest$D03EC9172026-11-25479 KBDownload

About this file

This is the official ETS product database for the Berker 2-fold input, battery, embedded (85876210), published by the manufacturer in the KNX online catalog. To use it, open ETS, go to Catalogs → Import and choose the downloaded .knxprod file. The device then appears in your catalog and can be added to a project. Older versions are kept so existing projects can be matched to the application program they were commissioned with.

More from Berker

All Berker products