KNX Database

Movement detector, 180° 80262xxx

Berker · Order number 80262xxx · Presence detectors › Presence detectors

80262xxx

Download .knxprod S80262xxx 1.0 · 246 KB

Product

ManufacturerBerker
Product nameMovement detector, 180°
Order number80262xxx
Hardware80262xxx
MediumTwisted Pair
Bus current (mA)20
Rail mountedNo
RegistrationRegistered · 2016-01-15
Languagesfr-FR, de-DE, it-IT, nl-NL, pt-PT, nb-NO, sv-SE
Catalog entryM-0006_H-6.20.2F.2F.2080262xxx-0_HP-E05A-10-924E_CI-80262xxx-1
Fingerprint924E
SHA-2561f4ee6f80e6c11d5d3de6ed48e8f05fc80f9fac7b84bb25f181416c4ad5b626b
First seen2026-11-25
Markets69 markets

Application program: S80262xxx 1.0

Application number$E05A
Version1.0
Mask versionMV-0701 (7.1)
KNX Data SecureNo
Minimum ETS version4.0
Parameters299
Group objects101
Group objects (101)
NoNameFunctionSizeDPTFlags
0General-presence detectionAutomatic control deactivation1 Bit1.3 enableCRW
1General-presence detectionAutomatic control deactivation status1 Bit1.3 enableCRT
2General-presence detectionLock-up1 Bit1.3 enableCRW
3General-presence detectionLock-up right sensor1 Bit1.3 enableCRW
4General-presence detectionLuminosity2 Bytes9.4 lux (Lux)CRW
5General-presence detectionSurveillance mode ON/OFF1 Bit1.1 switchCRW
6General-presence detectionMaster1 Bit1.1 switchCRW
7General-presence detectionSlave1 Bit1.1 switchCRT
8General-presence detectionMaster with luminosity info1 Bit1.1 switchCRW
9General-presence detectionSlave with luminosity info1 Bit1.1 switchCRT
10Lighting channel 1ON/OFF automatic control1 Bit1.1 switchCRT
10Lighting channel 1Timer1 Bit1.10 start/stopCRT
10Lighting channel 1Up/down1 Bit1.8 up/downCRT
11Lighting channel 1Value (0-255)1 Byte5.10 counter pulses (0..255)CRT
11Lighting channel 1Value in %1 Byte5.1 percentage (0..100%)CRT
11Lighting channel 1Setpoint selection automatic control1 Byte20.102 HVAC modeCRT
11Lighting channel 1Position in % automatic control1 Byte5.1 percentage (0..100%)CRT
11Lighting channel 1Scene1 Byte18.1 scene controlCRT
12Lighting channel 1Slat angle in % automatic control1 Byte5.1 percentage (0..100%)CRT
13Lighting channel 1Surveillance channel1 Bit1.2 booleanCRT
14Lighting channel 2ON/OFF automatic control1 Bit1.1 switchCRT
14Lighting channel 2Timer1 Bit1.10 start/stopCRT
14Lighting channel 2Up/down1 Bit1.8 up/downCRT
15Lighting channel 2Value (0-255)1 Byte5.10 counter pulses (0..255)CRT
15Lighting channel 2Value in %1 Byte5.1 percentage (0..100%)CRT
15Lighting channel 2Setpoint selection automatic control1 Byte20.102 HVAC modeCRT
15Lighting channel 2Position in % automatic control1 Byte5.1 percentage (0..100%)CRT
15Lighting channel 2Scene1 Byte18.1 scene controlCRT
16Lighting channel 2Slat angle in % automatic control1 Byte5.1 percentage (0..100%)CRT
17Lighting channel 2Surveillance channel1 Bit1.2 booleanCRT
18SurveillanceON/OFF automatic control1 Bit1.1 switchCRT
18SurveillanceTimer1 Bit1.10 start/stopCRT
18SurveillanceUp/down1 Bit1.8 up/downCRT
19SurveillanceValue (0-255)1 Byte5.10 counter pulses (0..255)CRT
19SurveillanceValue in %1 Byte5.1 percentage (0..100%)CRT
19SurveillanceSetpoint selection automatic control1 Byte20.102 HVAC modeCRT
19SurveillancePosition in % automatic control1 Byte5.1 percentage (0..100%)CRT
19SurveillanceScene1 Byte18.1 scene controlCRT
20SurveillanceSlat angle in % automatic control1 Byte5.1 percentage (0..100%)CRT
21SurveillanceSurveillance channel1 Bit1.2 booleanCRT
22General- push-buttonAntitheft alarm 1 bit1 Bit1.5 alarmCRT
23General- push-buttonAntitheft alarm 1 byte1 Byte5.10 counter pulses (0..255)CRT
24General- push-buttonConfiguration second level1 Bit1.11 stateCRW
25General- push-buttonAlarm1 Bit1.5 alarmCRW
26General- push-buttonLock-up1 Bit1.1 switchCRW
27Push-buttonSeparately LED object1 Bit1.1 switchCRW
28Push-buttonAutomatic control deactivation status1 Bit1.3 enableCRW
28Push-buttonHeating/Cooling - status indication1 Bit1.100 heating/coolingCRW
28Push-buttonStatus indication ON/OFF1 Bit1.1 switchCRW
28Push-buttonChannel A status1 Bit1.1 switchCRW
28Push-buttonStatus indication priority1 Bit1.11 stateCRW
28Push-buttonUpper position reached1 Bit1.2 booleanCRW
29Push-buttonLower position reached1 Bit1.2 booleanCRW
30Push-buttonStatus indication setpoint selection1 Byte20.102 HVAC modeCRW
31Push-buttonSlat angle in %1 Bit1.1 switchCRW
32Push-buttonOverride setpoint status2 Bytes9.2 temperature difference (K)CRW
33Push-buttonAutomatic control deactivation1 Bit1.3 enableCRT
33Push-buttonHeating/Cooling - changeover1 Bit1.100 heating/coolingCRT
33Push-buttonON/OFF1 Bit1.1 switchCRT
33Push-buttonTimer1 Bit1.10 start/stopCRT
33Push-buttonUp/down1 Bit1.8 up/downCRT
33Push-buttonON/OFF Channel A1 Bit1.1 switchCRT
33Push-buttonPresence1 Bit1.1 switchCRT
34Push-buttonStep/stop (short press)1 Bit1.7 stepCRT
34Push-buttonStop (short press)1 Bit1.17 triggerCRT
35Push-buttonPriority2 Bit2.2 boolean controlCRT
36Push-buttonDimming4 Bit3.7 dimming controlCRT
37Push-buttonBrightness value1 Byte5.1 percentage (0..100%)CRT
37Push-buttonSetpoint selection1 Byte20.102 HVAC modeCRT
37Push-buttonPosition in %1 Byte5.1 percentage (0..100%)CRT
37Push-buttonScene1 Byte18.1 scene controlCRT
37Push-buttonValue (0-255)1 Byte5.10 counter pulses (0..255)CRT
37Push-buttonChannel A value (0-255)1 Byte5.10 counter pulses (0..255)CRT
37Push-buttonValue in %1 Byte5.1 percentage (0..100%)CRT
37Push-buttonChannel A value (%)1 Byte5.1 percentage (0..100%)CRT
37Push-buttonStepping switch (%)1 Byte5.1 percentage (0..100%)CRT
37Push-buttonStepping switch (Scene)1 Byte18.1 scene controlCRT
37Push-buttonStepping switch (0-255)1 Byte5.10 counter pulses (0..255)CRT
38Push-buttonSlat angle in %1 Byte5.1 percentage (0..100%)CRT
39Push-buttonOverride setpoint2 Bytes9.2 temperature difference (K)CRT
39Push-buttonValue (0-65535)2 Bytes7.1 pulsesCRT
39Push-buttonChannel A value (0-65535)2 Bytes7.1 pulsesCRT
39Push-buttonLuminosity2 Bytes9.4 lux (Lux)CRT
39Push-buttonChannel A value (Luminosity)2 Bytes9.4 lux (Lux)CRT
39Push-buttonTemperature2 Bytes9.1 temperature (°C)CRT
39Push-buttonChannel A value (Temperature)2 Bytes9.1 temperature (°C)CRT
40Push-buttonChannel B status1 Bit1.1 switchCRW
41Push-buttonON/OFF Channel B1 Bit1.1 switchCRT
42Push-buttonChannel B value (0-255)1 Byte5.10 counter pulses (0..255)CRT
42Push-buttonChannel B value (%)1 Byte5.1 percentage (0..100%)CRT
43Push-buttonChannel B value (0-65535)2 Bytes7.1 pulsesCRT
43Push-buttonChannel B value (Luminosity)2 Bytes9.4 lux (Lux)CRT
43Push-buttonChannel B value (Temperature)2 Bytes9.1 temperature (°C)CRT
44Push-buttonOverride setpoint status1 Byte20.102 HVAC modeCRW
45Push-buttonStatus LED - 2 bytes signed2 Bytes8.1 pulses differenceCRW
45Push-buttonStatus LED - 2 bytes unsigned2 Bytes7.1 pulsesCRW
46Push-buttonStatus LED - 1 byte signed1 Byte6.10 counter pulses (-128..127)CRW
46Push-buttonStatus LED - 1 byte unsigned1 Byte5.10 counter pulses (0..255)CRW
47Internal temperature sensorRoom temperature2 Bytes9.1 temperature (°C)CRT
47Internal temperature sensorInternal temperature sensor2 Bytes9.1 temperature (°C)CRT
48Luminosity sensorLuminosity2 Bytes9.4 lux (Lux)CRT
Parameters (184)
ParameterTypeDefault
Detector typelistStandalone device
Channel 1 functionlistNot active
Channel 2 functionlistNot active
Function channel 3listSurveillance
Polarity of surveillance channellistON = 0
Test modeunsignedInt 0…11
Potentiometer settings- luminositylistAuthorization
Potentiometer settings-overrun timelistAuthorization
Potentiometer settings-sensitivitylistAuthorization
Luminosity informationunsignedInt 0…10
Behaviour device buttonlistFunction selection
DTP not usedunsignedInt 0…10
Function selectionlistON/OFF/Auto
Presence simulationunsignedInt 0…11
Luminosity memorisation by long key pressunsignedInt 0…11
Party modeunsignedInt 0…11
Lock-up device buttonunsignedInt 0…11
Lock-upunsignedInt 0…10
Polarity of lock-up objectlistON = 1
Polarity of lock-up objectlistON = 0
Operating mode after bus bus power return - presence detection 1listMaintain status
Operating mode after bus bus power return - presence detection 2listMaintain status
Behaviour during bus return - Slave modelistMaintain status
Left zoneunsignedInt 0…11
Right zoneunsignedInt 0…11
Telegram by start of presence detectionlistNot active
Luminosity threshold throughlistPotentiometer settings
Luminosity threshold throughlistFixed parameter
Luminosity thresholdfloat 0…10000
Periodical emissionunsignedInt 0…10
Periodical emission delaylist30 min
Emission by new detectionunsignedInt 0…10
Telegram by end of presence detectionlistNot active
Emission time delaylistNot active
Selection overrun timelistPotentiometer settings
Selection overrun timelistFixed parameter
Overrun timelist1 min
Lock-up duration after end of detectionlist1 s
Value 1 bytelistValue (0-255)
Telegram by start of presence detectionunsignedInt 0…11
Brightness value 1unsignedInt 0…255255
Value (0-255)unsignedInt 0…255255
Telegram by end of presence detectionunsignedInt 0…11
Brightness value 2unsignedInt 0…2550
Value (0-255)unsignedInt 0…2550
Scene numberunsignedInt 0…630
Scene numberunsignedInt 0…631
FunctionlistNot active
Position 1 (0-100%)unsignedInt 0…2550
Position 2 (0-100%)unsignedInt 0…2551
Slat angle (0-100%)unsignedInt 0…2550
Slat angle 2 (0-100%)unsignedInt 0…2551
Current modelistAuto
Current modelistComfort
TECH_AJS Generic MotionlistTECH_No function
Status at bus returnlistMaintain status
Lock-up duration after end of detectionlist5 s
Alarm monitoring periodlist1 min
Number of detectionsunsignedInt 1…2551
Duration of long key-press dimming, shutters/blindslist500 ms
Duration of long key-press 2-channel modelist5 s
Function of LED lock-uplistBlinking
LED colourlistGreen
Antitheft alarmlistNot active
Antitheft alarm valueunsignedInt 0…2551
Periodical emission of antitheft alarmlist5 min
Time limitedunsignedInt 0…10
TECH_AJS GPB_LedDisplaylistToggle switch
Function by presslistON
TECH_Enable 1unsignedInt 0…10
Function 1listON
Emission time delay by presslistImmediate emission
Function on releaselistOFF
TECH_Enable 2unsignedInt 0…10
Function 2listON
Emission time delay on releaselistImmediate emission
DimminglistIncrease (ON)
TECH_Toggle behaviorunsignedInt 0…10
DimmingDownlistON
DimmingUplistON
Value in %unsignedInt 0…2550
Using modelistHager/Berker behaviour
Duration between short and long key-pressunsignedInt 0…65535500
Duration for slat angle adjustmentunsignedInt 0…65535500
Closing typelistShutter
Shutter functionlistUp
Function by press ShutterlistUp
TECH_Toggle behaviorunsignedInt 0…11
Position (0-100%)unsignedInt 0…2550
SaftyunsignedInt 0…10
Shutter function 2listUp
Blind functionlistUp
Value 2 byteslistValue (0-65535)
Value (0-65535)unsignedInt 0…655350
Temperaturefloat 0…400
Luminosity levelfloat 0…400
Thermostat extensionlistSetpoint selection
Override setpointunsignedInt 0…655350
PresencelistPresence ON
PrioritylistON
Scenes memorisation by long key pressunsignedInt 0…11
Emission time delaylistImmediate emission
Using modelistChannel A or B
Channel A functionlistON/OFF
Function by presslistNot active
Value (%)unsignedInt 0…2550
Luminosity level by short pressfloat 0…400
Channel B functionlistON/OFF
Luminosity level by long pressfloat 0…400
Value type stepping switchlistValue (0-255)
BehaviourlistPass through
Stepping numberunsignedInt 1…71
Step 1 (0-255)unsignedInt 0…2550
Step 2 (0-255)unsignedInt 0…2551
Step 3 (0-255)unsignedInt 0…2552
Step 4 (0-255)unsignedInt 0…2553
Step 5 (0-255)unsignedInt 0…2554
Step 6 (0-255)unsignedInt 0…2555
Step 7 (0-255)unsignedInt 0…2556
Step 1 (0-100%)unsignedInt 0…2550
Step 2 (0-100%)unsignedInt 0…2551
Step 3 (0-100%)unsignedInt 0…2552
Step 4 (0-100%)unsignedInt 0…2553
Step 5 (0-100%)unsignedInt 0…2554
Step 6 (0-100%)unsignedInt 0…2555
Step 7 (0-100%)unsignedInt 0…2556
Step 1 (scene 1-64)unsignedInt 0…630
Step 2 (scene 1-64)unsignedInt 0…631
Step 3 (scene 1-64)unsignedInt 0…632
Step 4 (scene 1-64)unsignedInt 0…633
Step 5 (scene 1-64)unsignedInt 0…634
Step 6 (scene 1-64)unsignedInt 0…635
Step 7 (scene 1-64)unsignedInt 0…636
Function of LED statuslistAlways OFF
LED behaviourlistStatus indication (ON = 1)
LED colour for ONlistGreen
LED colour for OFFlistOFF
LED colour for comfortlistRed
LED colour for standbylistOFF
LED colour for night setpointlistGreen
LED colour for frost/heat protectionlistRed/green
LED colour (over setpoint)listRed
LED colour (equal setpoint)listGreen
LED colour (under setpoint)listRed/green
Compare function (unsigned)listCompare 1 byte unsigned
Compare function (signed)listCompare 1 byte signed
Compare setpoint value 1 byte unsignedunsignedInt 0…2550
Compare setpoint value 2 bytes unsignedunsignedInt 0…655350
Compare setpoint value 1 byte signedsignedInt -128…1270
Compare setpoint value 2 bytes signedsignedInt -32768…327670
Emission of temperature valuelistNot active
Temperature calibrationlist 0,0°C
Temperature emission by variation of (x0,1°C)unsignedInt 0…2555
Temperature periodical emissionlist10 min
Emission of luminosity valuelistNot active
Luminosity periodical emissionlist10 min
Luminosity emission by variation of (hysteresis)unsignedInt 0…1000
Application software versiontext0
Database versiontext1.0.69 d1
Version of translation filelist3
Brightness value 1unsignedInt 0…1000
Brightness value 2unsignedInt 0…1000
Scene numberunsignedInt 1…641
Step 1 (scene 1-64)unsignedInt 1…641
Step 2 (scene 1-64)unsignedInt 1…641
Step 3 (scene 1-64)unsignedInt 1…641
Step 4 (scene 1-64)unsignedInt 1…641
Step 5 (scene 1-64)unsignedInt 1…641
Step 6 (scene 1-64)unsignedInt 1…641
Step 7 (scene 1-64)unsignedInt 1…641
Position (0-100%)unsignedInt 0…1000
Slat angle (0-100%)unsignedInt 0…1000
Value (0-100%)unsignedInt 0…1000
Override setpointlist+1,0°C
Value (%)unsignedInt 0…1000
Step 1 (0-100%)unsignedInt 0…1000
Step 2 (0-100%)unsignedInt 0…1000
Step 3 (0-100%)unsignedInt 0…1000
Step 4 (0-100%)unsignedInt 0…1000
Step 5 (0-100%)unsignedInt 0…1000
Step 6 (0-100%)unsignedInt 0…1000
Step 7 (0-100%)unsignedInt 0…1000
Luminosity levelfloat 0…10000
Lock-up duration after end of detectionlist15 s

Version history

ApplicationApp noFingerprintFirst seenSizeFile
S80262xxx 1.0 latest$E05A924E2026-11-25246 KBDownload

About this file

This is the official ETS product database for the Berker Movement detector, 180° (80262xxx), published by the manufacturer in the KNX online catalog. To use it, open ETS, go to Catalogs → Import and choose the downloaded .knxprod file. The device then appears in your catalog and can be added to a project. Older versions are kept so existing projects can be matched to the application program they were commissioned with.

More from Berker

All Berker products