Schaltaktor 8fach 16A REG 75318004
Berker · Order number 75318004 · Outputs › 8-output modules
75318004
Download .knxprod Schalten RM, VK, ZF 208811 1.1 · 167 KB
Product
| Manufacturer | Berker |
|---|---|
| Product name | Schaltaktor 8fach 16A REG |
| Order number | 75318004 |
| Hardware | REG 2006 Schaltaktor 8fach |
| Medium | Twisted Pair |
| Bus current (mA) | 6 |
| Rail mounted | Yes |
| Width (mm) | 144 |
| Registration | Registered |
| Languages | de-DE |
| Catalog entry | M-0006_H-6.20.2F.2F.2075318004-1-O000A_HP-2088-11-F079-O000A_CI-75318004-1 |
| Fingerprint | F079 |
| SHA-256 | 8d58dfbebb8c73d1370e56fb7f774f160f22d58c3e4c9b0c6a412069f3a9083b |
| First seen | 2026-11-25 |
| Markets | 69 markets |
Application program: Schalten RM, VK, ZF 208811 1.1
| Application number | $2088 |
|---|---|
| Version | 1.1 |
| Mask version | MV-0705 (7.5) |
| KNX Data Secure | No |
| Minimum ETS version | 3.0d |
| Parameters | 1376 |
| Group objects | 352 |
Group objects (352)
| No | Name | Function | Size | DPT | Flags |
|---|---|---|---|---|---|
| 0 | Handbedienung | Sperren | 1 Bit | CW | |
| 0 | Object 1 | 1 Bit | CW | ||
| 1 | Handbedienung | Status | 1 Bit | CT | |
| 1 | Object 2 | 1 Bit | CT | ||
| 2 | Object 3 | 1 Bit | CW | ||
| 2 | Alle Jalousieausgänge | Zentral fahren | 1 Bit | CW | |
| 3 | Object 4 | 1 Bit | CW | ||
| 4 | Object 5 | 1 Bit | CW | ||
| 5 | Object 6 | 1 Bit | CW | ||
| 6 | Object 7 | 1 Bit | CW | ||
| 7 | Object 8 | 1 Bit | CW | ||
| 8 | Object 9 | 1 Bit | CW | ||
| 8 | Alle Schaltausgänge | Zentral schalten | 1 Bit | CW | |
| 9 | Object 10 | 4 Bytes | CT | ||
| 9 | Alle Schaltausgänge | Sammelrückmeldung | 4 Bytes | CT | |
| 9 | Alle Schaltausgänge | Sammelrückmeldung | 4 Bytes | CR | |
| 10 | Ausgang 1 | Schalten | 1 Bit | CW | |
| 10 | Object 11 | 1 Bit | CW | ||
| 11 | Ausgang 1 | Zwangsstellung | 2 Bit | CW | |
| 11 | Object 12 | 1 Bit | CW | ||
| 12 | Ausgang 1 | Sperren | 1 Bit | CW | |
| 12 | Object 13 | 1 Bit | CW | ||
| 13 | Object 14 | 1 Byte | CW | ||
| 13 | Ausgang 1 | Verknüpfung | 1 Bit | CW | |
| 14 | Ausgang 1 | Treppenhausfunktion Start/Stop | 1 Bit | CW | |
| 14 | Object 15 | 1 Bit | CT | ||
| 15 | Ausgang 1 | Treppenhauszeit Faktor | 1 Byte | CW | |
| 15 | Object 16 | 1 Bit | CW | ||
| 16 | Ausgang 1 | Szenennebenstelle | 1 Byte | CW | |
| 16 | Object 17 | 1 Bit | CW | ||
| 17 | Ausgang 1 | Szenenstatus | 1 Byte | CT | |
| 17 | Ausgang 1 | Szenenstatus | 1 Byte | CR | |
| 17 | Object 18 | 1 Bit | CW | ||
| 18 | Ausgang 1 | Rückmeldung schalten | 1 Bit | CT | |
| 18 | Object 19 | 1 Bit | CW | ||
| 18 | Ausgang 1 | Rückmeldung schalten | 1 Bit | CR | |
| 19 | Object 20 | 2 Bytes | CW | ||
| 19 | Ausgang 1 | Grenzwert Betriebsstundenzähl. | 2 Bytes | CW | |
| 19 | Ausgang 1 | Startwert Betriebsstundenzähl. | 2 Bytes | CW | |
| 20 | Object 21 | 1 Bit | CW | ||
| 20 | Ausgang 1 | Neustart Betriebsstundenzähler | 1 Bit | CW | |
| 21 | Object 22 | 2 Bytes | CT | ||
| 21 | Ausgang 1 | Wert Betriebsstundenzähler | 2 Bytes | CT | |
| 22 | Object 23 | 1 Bit | CT | ||
| 22 | Ausgang 1 | Ablauf Betriebsstundenzähler | 1 Bit | CT | |
| 23 | Object 24 | 1 Bit | CW | ||
| 24 | Object 25 | 1 Byte | CT | ||
| 25 | Object 26 | 1 Byte | CT | ||
| 26 | Object 27 | 1 Bit | CR | ||
| 27 | Object 28 | 1 Bit | CT | ||
| 28 | Object 29 | 1 Byte | CW | ||
| 29 | Object 30 | 1 Byte | CW | ||
| 30 | Object 31 | 1 Bit | CT | ||
| 31 | Object 32 | 1 Bit | CT | ||
| 32 | Object 33 | 2 Bytes | CW | ||
| 33 | Object 34 | 1 Bit | CW | ||
| 34 | Object 35 | 2 Bytes | CT | ||
| 35 | Object 36 | 1 Bit | CT | ||
| 36 | Object 37 | 1 Bit | CW | ||
| 36 | Ausgang 2 | Schalten | 1 Bit | CW | |
| 37 | Object 38 | 1 Bit | CW | ||
| 37 | Ausgang 2 | Zwangsstellung | 2 Bit | CW | |
| 38 | Object 39 | 1 Bit | CW | ||
| 38 | Ausgang 2 | Sperren | 1 Bit | CW | |
| 39 | Object 40 | 1 Bit | CW | ||
| 39 | Ausgang 2 | Verknüpfung | 1 Bit | CW | |
| 40 | Object 41 | 1 Bit | CW | ||
| 40 | Ausgang 2 | Treppenhausfunktion Start/Stop | 1 Bit | CW | |
| 41 | Object 42 | 1 Byte | CW | ||
| 41 | Ausgang 2 | Treppenhauszeit Faktor | 1 Byte | CW | |
| 42 | Object 43 | 1 Byte | CW | ||
| 42 | Ausgang 2 | Szenennebenstelle | 1 Byte | CW | |
| 43 | Object 44 | 1 Byte | CT | ||
| 43 | Ausgang 2 | Szenenstatus | 1 Byte | CT | |
| 43 | Ausgang 2 | Szenenstatus | 1 Byte | CR | |
| 44 | Object 45 | 1 Bit | CT | ||
| 44 | Ausgang 2 | Rückmeldung schalten | 1 Bit | CT | |
| 44 | Ausgang 2 | Rückmeldung schalten | 1 Bit | CR | |
| 45 | Object 46 | 2 Bytes | CW | ||
| 45 | Ausgang 2 | Grenzwert Betriebsstundenzähl. | 2 Bytes | CW | |
| 45 | Ausgang 2 | Startwert Betriebsstundenzähl. | 2 Bytes | CW | |
| 46 | Object 47 | 1 Bit | CW | ||
| 46 | Ausgang 2 | Neustart Betriebsstundenzähler | 1 Bit | CW | |
| 47 | Object 48 | 2 Bytes | CT | ||
| 47 | Ausgang 2 | Wert Betriebsstundenzähler | 2 Bytes | CT | |
| 48 | Object 49 | 1 Bit | CT | ||
| 48 | Ausgang 2 | Ablauf Betriebsstundenzähler | 1 Bit | CT | |
| 49 | Object 50 | 1 Bit | CW | ||
| 50 | Object 51 | 1 Bit | CW | ||
| 51 | Object 52 | 1 Bit | CW | ||
| 52 | Object 53 | 1 Bit | CW | ||
| 53 | Object 54 | 1 Bit | CW | ||
| 54 | Object 55 | 1 Byte | CW | ||
| 55 | Object 56 | 1 Byte | CW | ||
| 56 | Object 57 | 1 Byte | CT | ||
| 57 | Object 58 | 1 Bit | CT | ||
| 58 | Object 59 | 2 Bytes | CW | ||
| 59 | Object 60 | 1 Bit | CW | ||
| 60 | Object 61 | 2 Bytes | CT | ||
| 61 | Object 62 | 1 Bit | CT | ||
| 62 | Object 63 | 1 Bit | CW | ||
| 62 | Ausgang 3 | Schalten | 1 Bit | CW | |
| 63 | Object 64 | 1 Bit | CW | ||
| 63 | Ausgang 3 | Zwangsstellung | 2 Bit | CW | |
| 64 | Object 65 | 1 Bit | CW | ||
| 64 | Ausgang 3 | Sperren | 1 Bit | CW | |
| 65 | Object 66 | 1 Bit | CW | ||
| 65 | Ausgang 3 | Verknüpfung | 1 Bit | CW | |
| 66 | Object 67 | 1 Bit | CW | ||
| 66 | Ausgang 3 | Treppenhausfunktion Start/Stop | 1 Bit | CW | |
| 67 | Object 68 | 1 Byte | CW | ||
| 67 | Ausgang 3 | Treppenhauszeit Faktor | 1 Byte | CW | |
| 68 | Object 69 | 1 Byte | CW | ||
| 68 | Ausgang 3 | Szenennebenstelle | 1 Byte | CW | |
| 69 | Object 70 | 1 Byte | CT | ||
| 69 | Ausgang 3 | Szenenstatus | 1 Byte | CT | |
| 69 | Ausgang 3 | Szenenstatus | 1 Byte | CR | |
| 70 | Object 71 | 1 Bit | CT | ||
| 70 | Ausgang 3 | Rückmeldung schalten | 1 Bit | CT | |
| 70 | Ausgang 3 | Rückmeldung schalten | 1 Bit | CR | |
| 71 | Object 72 | 2 Bytes | CW | ||
| 71 | Ausgang 3 | Grenzwert Betriebsstundenzähl. | 2 Bytes | CW | |
| 71 | Ausgang 3 | Startwert Betriebsstundenzähl. | 2 Bytes | CW | |
| 72 | Object 73 | 1 Bit | CW | ||
| 72 | Ausgang 3 | Neustart Betriebsstundenzähler | 1 Bit | CW | |
| 73 | Object 74 | 2 Bytes | CT | ||
| 73 | Ausgang 3 | Wert Betriebsstundenzähler | 2 Bytes | CT | |
| 74 | Object 75 | 1 Bit | CT | ||
| 74 | Ausgang 3 | Ablauf Betriebsstundenzähler | 1 Bit | CT | |
| 75 | Object 76 | 1 Bit | CW | ||
| 76 | Object 77 | 1 Bit | CW | ||
| 77 | Object 78 | 1 Bit | CW | ||
| 78 | Object 79 | 1 Bit | CW | ||
| 79 | Object 80 | 1 Bit | CW | ||
| 80 | Object 81 | 1 Byte | CW | ||
| 81 | Object 82 | 1 Byte | CW | ||
| 82 | Object 83 | 1 Byte | CT | ||
| 83 | Object 84 | 1 Bit | CT | ||
| 84 | Object 85 | 2 Bytes | CW | ||
| 85 | Object 86 | 1 Bit | CW | ||
| 86 | Object 87 | 2 Bytes | CT | ||
| 87 | Object 88 | 1 Bit | CT | ||
| 88 | Object 89 | 1 Bit | CW | ||
| 88 | Ausgang 4 | Schalten | 1 Bit | CW | |
| 89 | Object 90 | 1 Bit | CW | ||
| 89 | Ausgang 4 | Zwangsstellung | 2 Bit | CW | |
| 90 | Object 91 | 1 Bit | CW | ||
| 90 | Ausgang 4 | Sperren | 1 Bit | CW | |
| 91 | Object 92 | 1 Bit | CW | ||
| 91 | Ausgang 4 | Verknüpfung | 1 Bit | CW | |
| 92 | Object 93 | 1 Bit | CW | ||
| 92 | Ausgang 4 | Treppenhausfunktion Start/Stop | 1 Bit | CW | |
| 93 | Object 94 | 1 Byte | CW | ||
| 93 | Ausgang 4 | Treppenhauszeit Faktor | 1 Byte | CW | |
| 94 | Object 95 | 1 Byte | CW | ||
| 94 | Ausgang 4 | Szenennebenstelle | 1 Byte | CW | |
| 95 | Object 96 | 1 Byte | CT | ||
| 95 | Ausgang 4 | Szenenstatus | 1 Byte | CT | |
| 95 | Ausgang 4 | Szenenstatus | 1 Byte | CR | |
| 96 | Object 97 | 1 Bit | CT | ||
| 96 | Ausgang 4 | Rückmeldung schalten | 1 Bit | CT | |
| 96 | Ausgang 4 | Rückmeldung schalten | 1 Bit | CR | |
| 97 | Object 98 | 2 Bytes | CW | ||
| 97 | Ausgang 4 | Grenzwert Betriebsstundenzähl. | 2 Bytes | CW | |
| 97 | Ausgang 4 | Startwert Betriebsstundenzähl. | 2 Bytes | CW | |
| 98 | Object 99 | 1 Bit | CW | ||
| 98 | Ausgang 4 | Neustart Betriebsstundenzähler | 1 Bit | CW | |
| 99 | Object 100 | 2 Bytes | CT | ||
| 99 | Ausgang 4 | Wert Betriebsstundenzähler | 2 Bytes | CT | |
| 100 | Object 101 | 1 Bit | CT | ||
| 100 | Ausgang 4 | Ablauf Betriebsstundenzähler | 1 Bit | CT | |
| 101 | Object 102 | 1 Bit | CW | ||
| 102 | Object 103 | 1 Bit | CW | ||
| 103 | Object 104 | 1 Bit | CW | ||
| 104 | Object 105 | 1 Bit | CW | ||
| 105 | Object 106 | 1 Bit | CW | ||
| 106 | Object 107 | 1 Byte | CW | ||
| 107 | Object 108 | 1 Byte | CW | ||
| 108 | Object 109 | 1 Byte | CT | ||
| 109 | Object 110 | 1 Bit | CT | ||
| 110 | Object 111 | 2 Bytes | CW | ||
| 111 | Object 112 | 1 Bit | CW | ||
| 112 | Object 113 | 2 Bytes | CT | ||
| 113 | Object 114 | 1 Bit | CT | ||
| 114 | Object 115 | 1 Bit | CW | ||
| 114 | Ausgang 5 | Schalten | 1 Bit | CW | |
| 115 | Object 116 | 1 Bit | CW | ||
| 115 | Ausgang 5 | Zwangsstellung | 2 Bit | CW | |
| 116 | Object 117 | 1 Bit | CW | ||
| 116 | Ausgang 5 | Sperren | 1 Bit | CW | |
| 117 | Object 118 | 1 Bit | CW | ||
| 117 | Ausgang 5 | Verknüpfung | 1 Bit | CW | |
| 118 | Object 119 | 1 Bit | CW | ||
| 118 | Ausgang 5 | Treppenhausfunktion Start/Stop | 1 Bit | CW | |
| 119 | Object 120 | 1 Byte | CW | ||
| 119 | Ausgang 5 | Treppenhauszeit Faktor | 1 Byte | CW | |
| 120 | Object 121 | 1 Byte | CW | ||
| 120 | Ausgang 5 | Szenennebenstelle | 1 Byte | CW | |
| 121 | Object 122 | 1 Byte | CT | ||
| 121 | Ausgang 5 | Szenenstatus | 1 Byte | CT | |
| 121 | Ausgang 5 | Szenenstatus | 1 Byte | CR | |
| 122 | Object 123 | 1 Bit | CT | ||
| 122 | Ausgang 5 | Rückmeldung schalten | 1 Bit | CT | |
| 122 | Ausgang 5 | Rückmeldung schalten | 1 Bit | CR | |
| 123 | Object 124 | 2 Bytes | CW | ||
| 123 | Ausgang 5 | Grenzwert Betriebsstundenzähl. | 2 Bytes | CW | |
| 123 | Ausgang 5 | Startwert Betriebsstundenzähl. | 2 Bytes | CW | |
| 124 | Object 125 | 1 Bit | CW | ||
| 124 | Ausgang 5 | Neustart Betriebsstundenzähler | 1 Bit | CW | |
| 125 | Object 126 | 2 Bytes | CT | ||
| 125 | Ausgang 5 | Wert Betriebsstundenzähler | 2 Bytes | CT | |
| 126 | Object 127 | 1 Bit | CT | ||
| 126 | Ausgang 5 | Ablauf Betriebsstundenzähler | 1 Bit | CT | |
| 127 | Object 128 | 1 Bit | CW | ||
| 128 | Object 129 | 1 Bit | CW | ||
| 129 | Object 130 | 1 Bit | CW | ||
| 130 | Object 131 | 1 Bit | CW | ||
| 131 | Object 132 | 1 Bit | CW | ||
| 132 | Object 133 | 1 Byte | CW | ||
| 133 | Object 134 | 1 Byte | CW | ||
| 134 | Object 135 | 1 Byte | CT | ||
| 135 | Object 136 | 1 Bit | CT | ||
| 136 | Object 137 | 2 Bytes | CW | ||
| 137 | Object 138 | 1 Bit | CW | ||
| 138 | Object 139 | 2 Bytes | CT | ||
| 139 | Object 140 | 1 Bit | CT | ||
| 140 | Object 141 | 1 Bit | CW | ||
| 140 | Ausgang 6 | Schalten | 1 Bit | CW | |
| 141 | Object 142 | 1 Bit | CW | ||
| 141 | Ausgang 6 | Zwangsstellung | 2 Bit | CW | |
| 142 | Object 143 | 1 Bit | CW | ||
| 142 | Ausgang 6 | Sperren | 1 Bit | CW | |
| 143 | Object 144 | 1 Bit | CW | ||
| 143 | Ausgang 6 | Verknüpfung | 1 Bit | CW | |
| 144 | Object 145 | 1 Bit | CW | ||
| 144 | Ausgang 6 | Treppenhausfunktion Start/Stop | 1 Bit | CW | |
| 145 | Object 146 | 1 Byte | CW | ||
| 145 | Ausgang 6 | Treppenhauszeit Faktor | 1 Byte | CW | |
| 146 | Object 147 | 1 Byte | CW | ||
| 146 | Ausgang 6 | Szenennebenstelle | 1 Byte | CW | |
| 147 | Object 148 | 1 Byte | CT | ||
| 147 | Ausgang 6 | Szenenstatus | 1 Byte | CT | |
| 147 | Ausgang 6 | Szenenstatus | 1 Byte | CR | |
| 148 | Object 149 | 1 Bit | CT | ||
| 148 | Ausgang 6 | Rückmeldung schalten | 1 Bit | CT | |
| 148 | Ausgang 6 | Rückmeldung schalten | 1 Bit | CR | |
| 149 | Object 150 | 2 Bytes | CW | ||
| 149 | Ausgang 6 | Grenzwert Betriebsstundenzähl. | 2 Bytes | CW | |
| 149 | Ausgang 6 | Startwert Betriebsstundenzähl. | 2 Bytes | CW | |
| 150 | Object 151 | 1 Bit | CW | ||
| 150 | Ausgang 6 | Neustart Betriebsstundenzähler | 1 Bit | CW | |
| 151 | Object 152 | 2 Bytes | CT | ||
| 151 | Ausgang 6 | Wert Betriebsstundenzähler | 2 Bytes | CT | |
| 152 | Object 153 | 1 Bit | CT | ||
| 152 | Ausgang 6 | Ablauf Betriebsstundenzähler | 1 Bit | CT | |
| 153 | Object 154 | 1 Bit | CW | ||
| 154 | Object 155 | 1 Bit | CW | ||
| 155 | Object 156 | 1 Bit | CW | ||
| 156 | Object 157 | 1 Bit | CW | ||
| 157 | Object 158 | 1 Bit | CW | ||
| 158 | Object 159 | 1 Byte | CW | ||
| 159 | Object 160 | 1 Byte | CW | ||
| 160 | Object 161 | 1 Byte | CT | ||
| 161 | Object 162 | 1 Bit | CT | ||
| 162 | Object 163 | 2 Bytes | CW | ||
| 163 | Object 164 | 1 Bit | CW | ||
| 164 | Object 165 | 2 Bytes | CT | ||
| 165 | Object 166 | 1 Bit | CT | ||
| 166 | Object 167 | 1 Bit | CW | ||
| 166 | Ausgang 7 | Schalten | 1 Bit | CW | |
| 167 | Object 168 | 1 Bit | CW | ||
| 167 | Ausgang 7 | Zwangsstellung | 2 Bit | CW | |
| 168 | Object 169 | 1 Bit | CW | ||
| 168 | Ausgang 7 | Sperren | 1 Bit | CW | |
| 169 | Object 170 | 1 Bit | CW | ||
| 169 | Ausgang 7 | Verknüpfung | 1 Bit | CW | |
| 170 | Object 171 | 1 Bit | CW | ||
| 170 | Ausgang 7 | Treppenhausfunktion Start/Stop | 1 Bit | CW | |
| 171 | Object 172 | 1 Byte | CW | ||
| 171 | Ausgang 7 | Treppenhauszeit Faktor | 1 Byte | CW | |
| 172 | Object 173 | 1 Byte | CW | ||
| 172 | Ausgang 7 | Szenennebenstelle | 1 Byte | CW | |
| 173 | Object 174 | 1 Byte | CT | ||
| 173 | Ausgang 7 | Szenenstatus | 1 Byte | CT | |
| 173 | Ausgang 7 | Szenenstatus | 1 Byte | CR | |
| 174 | Object 175 | 1 Bit | CT | ||
| 174 | Ausgang 7 | Rückmeldung schalten | 1 Bit | CT | |
| 174 | Ausgang 7 | Rückmeldung schalten | 1 Bit | CR | |
| 175 | Object 176 | 2 Bytes | CW | ||
| 175 | Ausgang 7 | Grenzwert Betriebsstundenzähl. | 2 Bytes | CW | |
| 175 | Ausgang 7 | Startwert Betriebsstundenzähl. | 2 Bytes | CW | |
| 176 | Object 177 | 1 Bit | CW | ||
| 176 | Ausgang 7 | Neustart Betriebsstundenzähler | 1 Bit | CW | |
| 177 | Object 178 | 2 Bytes | CT | ||
| 177 | Ausgang 7 | Wert Betriebsstundenzähler | 2 Bytes | CT | |
| 178 | Object 179 | 1 Bit | CT | ||
| 178 | Ausgang 7 | Ablauf Betriebsstundenzähler | 1 Bit | CT | |
| 179 | Object 180 | 1 Bit | CW | ||
| 180 | Object 181 | 1 Bit | CW | ||
| 181 | Object 182 | 1 Bit | CW | ||
| 182 | Object 183 | 1 Bit | CW | ||
| 183 | Object 184 | 1 Bit | CW | ||
| 184 | Object 185 | 1 Byte | CW | ||
| 185 | Object 186 | 1 Byte | CW | ||
| 186 | Object 187 | 1 Byte | CT | ||
| 187 | Object 188 | 1 Bit | CT | ||
| 188 | Object 189 | 2 Bytes | CW | ||
| 189 | Object 190 | 1 Bit | CW | ||
| 190 | Object 191 | 2 Bytes | CT | ||
| 191 | Object 192 | 1 Bit | CT | ||
| 192 | Object 193 | 1 Bit | CW | ||
| 192 | Ausgang 8 | Schalten | 1 Bit | CW | |
| 193 | Object 194 | 1 Bit | CW | ||
| 193 | Ausgang 8 | Zwangsstellung | 2 Bit | CW | |
| 194 | Object 195 | 1 Bit | CW | ||
| 194 | Ausgang 8 | Sperren | 1 Bit | CW | |
| 195 | Object 196 | 1 Bit | CW | ||
| 195 | Ausgang 8 | Verknüpfung | 1 Bit | CW | |
| 196 | Object 197 | 1 Bit | CW | ||
| 196 | Ausgang 8 | Treppenhausfunktion Start/Stop | 1 Bit | CW | |
| 197 | Object 198 | 1 Byte | CW | ||
| 197 | Ausgang 8 | Treppenhauszeit Faktor | 1 Byte | CW | |
| 198 | Object 199 | 1 Byte | CW | ||
| 198 | Ausgang 8 | Szenennebenstelle | 1 Byte | CW | |
| 199 | Object 200 | 1 Byte | CT | ||
| 199 | Ausgang 8 | Szenenstatus | 1 Byte | CT | |
| 199 | Ausgang 8 | Szenenstatus | 1 Byte | CR | |
| 200 | Object 201 | 1 Bit | CT | ||
| 200 | Ausgang 8 | Rückmeldung schalten | 1 Bit | CT | |
| 200 | Ausgang 8 | Rückmeldung schalten | 1 Bit | CR | |
| 201 | Object 202 | 2 Bytes | CW | ||
| 201 | Ausgang 8 | Grenzwert Betriebsstundenzähl. | 2 Bytes | CW | |
| 201 | Ausgang 8 | Startwert Betriebsstundenzähl. | 2 Bytes | CW | |
| 202 | Object 203 | 1 Bit | CW | ||
| 202 | Ausgang 8 | Neustart Betriebsstundenzähler | 1 Bit | CW | |
| 203 | Object 204 | 2 Bytes | CT | ||
| 203 | Ausgang 8 | Wert Betriebsstundenzähler | 2 Bytes | CT | |
| 204 | Object 205 | 1 Bit | CT | ||
| 204 | Ausgang 8 | Ablauf Betriebsstundenzähler | 1 Bit | CT | |
| 205 | Object 206 | 1 Bit | CW | ||
| 206 | Object 207 | 1 Bit | CW | ||
| 207 | Object 208 | 1 Bit | CW | ||
| 208 | Object 209 | 1 Bit | CW | ||
| 209 | Object 210 | 1 Bit | CW | ||
| 210 | Object 211 | 1 Byte | CW | ||
| 211 | Object 212 | 1 Byte | CW | ||
| 212 | Object 213 | 1 Byte | CT | ||
| 213 | Object 214 | 1 Bit | CT | ||
| 214 | Object 215 | 2 Bytes | CW | ||
| 215 | Object 216 | 1 Bit | CW | ||
| 216 | Object 217 | 2 Bytes | CT | ||
| 217 | Object 218 | 1 Bit | CT |
Parameters (175)
| Parameter | Type | Default |
|---|---|---|
| Objekte | list | freigegeben |
| Müll | list | gesperrt |
| Müll | list | Aus |
| ETS_Download_I | unsignedInt 0…255 | 1 |
| ETS_Download_II | unsignedInt 0…255 | 1 |
| Maximal zulässige Fahrzeitänderung | list | 25 % |
| Verzögerung nach Busspannungswiederkehr Tage (0...7) | unsignedInt 0…7 | 0 |
| Verzögerung nach Busspannungswiederkehr Stunden (0...23) | unsignedInt 0…23 | 0 |
| Verzögerung nach Busspannungswiederkehr Minuten (0...59) | unsignedInt 0…59 | 0 |
| Sekunden (0...59) | unsignedInt 0…59 | 17 |
| Millisekunden (0...99) | unsignedInt 0…99 | 0 |
| Zentralfunktion ? | list | Nein |
| Polarität Zentralobjekt | list | 0 = ausschalten; 1 = einschalten |
| Zentralfunktion für Jalousieausgänge ? | list | Nein |
| Polarität Zentralobjekt | list | 0 = AUF; 1 = AB |
| Sammelrückmeldung nutzen ? | list | Nein |
| Zeitverzögerung für Rückmeldung nach Busspannungswiederkehr ? | list | Ja |
| Zyklisches Senden der Sammelrückmeldung ? | list | Nein (Senden nur bei Änderung) |
| Zeit für Blinken | list | 1 s |
| Zeit für zyklische Überwachung Tage (0...7) | unsignedInt 0…7 | 0 |
| Zeit für zyklische Überwachung Stunden (0...23) | unsignedInt 0…23 | 0 |
| Minuten (0...59) | unsignedInt 0…59 | 2 |
| Sekunden (10...59) | unsignedInt 10…59 | 10 |
| Zeit für zykl. Senden der Rückmeldung Tage (0...7) | unsignedInt 0…7 | 0 |
| Zeit für zykl. Senden der Rückmeldung Stunden (0...23) | unsignedInt 0…23 | 0 |
| Zeit für zykl. Senden Betriebsstunden Tage (0...7) | unsignedInt 0…7 | 0 |
| Zeit für zykl. Senden Betriebsstunden Stunden (0...23) | unsignedInt 0…23 | 23 |
| Minuten (0...59) | unsignedInt 0…59 | 0 |
| Sicherheitsfunktionen | list | gesperrt |
| Freigabe_Nein | list | Nein |
| Windalarm 1 | list | gesperrt |
| Windalarm 2 | list | gesperrt |
| Windalarm 3 | list | gesperrt |
| Regenalarm | list | gesperrt |
| Frostalarm | list | gesperrt |
| Priorität der Sicherheits-Alarme (hoch --> mittel --> niedrig) | list | Wind --> Regen --> Frost |
| Zeit für Überwachung Windalarm Tage (0...7) | unsignedInt 0…7 | 7 |
| Zeit für Überwachung Windalarm Stunden (0...23) | unsignedInt 0…23 | 23 |
| Minuten (1...59) | unsignedInt 1…59 | 59 |
| Sekunden (0...59) | unsignedInt 0…59 | 59 |
| Millisekunden (0...99) | unsignedInt 0…99 | 99 |
| Zeit für Überwachung Regenalarm Tage (0...7) | unsignedInt 0…7 | 7 |
| Zeit für Überwachung Regenalarm Stunden (0...23) | unsignedInt 0…23 | 23 |
| Zeit für Überwachung Frostalarm Tage (0...7) | unsignedInt 0…7 | 7 |
| Zeit für Überwachung Frostalarm Stunden (0...23) | unsignedInt 0…23 | 23 |
| Handbedienung bei Busspannungsausfall | list | freigegeben |
| Handbedienung bei Busbetrieb | list | freigegeben |
| Sperrfunktion ? | list | Nein |
| Polarität des Sperrobjektes | list | 0 = freigegeben; 1 = gesperrt |
| Status senden ? | list | Nein |
| Funktion und Polarität Statusobjekt | list | 0 = inaktiv; 1 = Handb. aktiv |
| Verhalten am Ende der permanenten Handbedienung bei Busbetrieb | list | keine Änderung |
| Bussteuerung von einzelnen Ausgängen bei Busbetrieb sperrbar ? | list | Nein |
| Ausgang 1 und Ausgang 2 | list | 2 x Schaltausgang |
| Ausgang 3 und Ausgang 4 | list | 2 x Schaltausgang |
| Ausgang 5 und Ausgang 6 | list | 2 x Schaltausgang |
| Ausgang 7 und Ausgang 8 | list | 2 x Schaltausgang |
| Ausgang 9 und Ausgang 10 | list | 2 x Schaltausgang |
| Ausgang 11 und Ausgang 12 | list | 2 x Schaltausgang |
| Ausgang 13 und Ausgang 14 | list | 2 x Schaltausgang |
| Ausgang 15 und Ausgang 16 | list | 2 x Schaltausgang |
| Betriebsart | list | Schließer |
| Verhalten nach ETS-Programmiervorgang | list | keine Reaktion |
| Verhalten bei Busspannungsausfall | list | keine Reaktion |
| Verhalten nach Bus- oder Netzspannungswiederkehr | list | Kontakt schließen |
| Treppenhausfunktion aktivieren nach Busspannungswiederkehr ? | list | Nein |
| Verhalten nach Busspannungswiederkehr | list | Zustand wie vor Busspannungsausfall |
| Zuordnung zur Zentralfunktion ? | list | Nein |
| Freigabe_zyklÜberwachung | list | Aus |
| Sicherheitszustand | list | Ein |
| Rückmeldung ? | list | keine |
| Rückmeldung_Pol | list | nicht invertieren |
| Zeitverzögerung für Rückmeldung nach Busspannungswiederkehr ? | list | Nein |
| Zyklisches Senden der Rückmeldung ? | list | Nein (Senden nur bei Änderung) |
| Zuordnung zur zyklischen Überwachung ? | list | Nein |
| Zeitverzögerungen ? | list | Nein |
| Zeitverzögerungen | list | gesperrt |
| Treppenhausfunktion ? | list | Nein |
| Treppenhausfunktion | list | gesperrt |
| Szenenfunktion ? | list | Nein |
| Szenenfunktion | list | gesperrt |
| Betriebsstundenzähler | list | gesperrt |
| Freigabe | list | nicht freigegeben |
| Auswahl der Zeitverzögerung | list | keine Zeitverzögerung |
| AUS_Freigabe | list | Ein |
| EIN_Freigabe | list | Aus |
| Einschaltverzögerung Tage (0...7) | unsignedInt 0…7 | 0 |
| Ausschaltverzögerung Tage (0...7) | unsignedInt 0…7 | 0 |
| Ausschaltverzögerung Stunden (0...23) | unsignedInt 0…23 | 0 |
| Einschaltverzögerung Stunden (0...23) | unsignedInt 0…23 | 0 |
| Sekunden (0...59) | unsignedInt 0…59 | 30 |
| Einschaltverzögerung nachtriggerbar ? | list | Nein |
| Ausschaltverzögerung nachtriggerbar ? | list | Nein |
| Treppenhauszeit Tage (0...7) | unsignedInt 0…7 | 0 |
| Treppenhauszeit Stunden (0...23) | unsignedInt 0…23 | 0 |
| Minuten (0...59) | unsignedInt 0…59 | 3 |
| Sekunden (0...59) | unsignedInt 0…59 | 0 |
| Treppenhauszeit nachtriggerbar ? | list | Ja |
| Reaktion auf AUS-Telegramm | list | ausschalten |
| Freigabe_Zeitverlängerung | list | Aus |
| Freigabe_Zeitvorgabe | list | Aus |
| Zusatzfunktion für Treppenhausfunktion | list | keine Zusatzfunktion |
| Treppenhauszeit über Bus einstellbar ? | list | Ja |
| Verlängerung der Treppenhauszeit zulassen ? | list | Ja |
| Treppenhausfunktion über Objekt "Treppenhauszeit" aktivierbar ? | list | Nein |
| Maximale Zeitverlängerung | list | 1fache Zeit |
| Einschaltverzögerung für die Treppenhausfunktion aktivieren ? | list | Nein |
| Einschaltverzögerung Tage | unsignedInt 0…7 | 0 |
| Einschaltverzögerung Tage (0...7) | unsignedInt 0…7 | 0 |
| Einschaltverzögerung Stunden | unsignedInt 0…23 | 0 |
| Einschaltverzögerung Stunden (0...23) | unsignedInt 0…23 | 0 |
| Minuten | unsignedInt 0…59 | 0 |
| Sekunden | unsignedInt 0…59 | 30 |
| Millisekunden | unsignedInt 0…99 | 0 |
| Vorwarnzeit aktivieren ? | list | Nein |
| Vorwarnzeit Tage (0...7) | unsignedInt 0…7 | 0 |
| Vorwarnzeit Stunden (0...23) | unsignedInt 0…23 | 0 |
| Vorwarnzeit Minuten (0...59) | unsignedInt 0…59 | 0 |
| Anzahl der Vorwarnungen (1...10) | unsignedInt 1…10 | 3 |
| Zeit für Vorwarnunterbrechungen Tage (0...7) | unsignedInt 0…7 | 0 |
| Zeit für Vorwarnunterbrechungen Stunden (0...23) | unsignedInt 0…23 | 0 |
| Zeit für Vorwarnunterbrechungen Minuten (0...59) | unsignedInt 0…59 | 0 |
| Zeit für Vorwarnunterbrechungen Sekunden (0...59) | unsignedInt 0…59 | 0 |
| Millisekunden (0...9 x 100) | unsignedInt 0…9 | 5 |
| Szenenabruf verzögern ? | list | Nein |
| Verzögerungszeit Tage (0...7) | unsignedInt 0…7 | 0 |
| Verzögerungszeit Stunden (0...23) | unsignedInt 0…23 | 0 |
| Verzögerungszeit Minuten (0...59) | unsignedInt 0…59 | 0 |
| Sekunden (0...59) | unsignedInt 0…59 | 10 |
| Szenenstatus (Wird später ausgeblendet!) | list | kein Szenenstatus |
| Im Gerät gespeicherte Werte beim ETS-Download überschreiben ? | list | Ja |
| Szene 1 aktivierbar durch Szenennummer (Szenennummer "0" = Szene deaktiviert) | unsignedInt 0…64 | 1 |
| Schaltzustand bei Szene 1 | list | ausschalten |
| Speicherfunktion für Szene 1 | list | Nein |
| Szene 2 aktivierbar durch Szenennummer (Szenennummer "0" = Szene deaktiviert) | unsignedInt 0…64 | 2 |
| Schaltzustand bei Szene 2 | list | ausschalten |
| Speicherfunktion für Szene 2 | list | Nein |
| Szene 3 aktivierbar durch Szenennummer (Szenennummer "0" = Szene deaktiviert) | unsignedInt 0…64 | 3 |
| Schaltzustand bei Szene 3 | list | ausschalten |
| Speicherfunktion für Szene 3 | list | Nein |
| Szene 4 aktivierbar durch Szenennummer (Szenennummer "0" = Szene deaktiviert) | unsignedInt 0…64 | 4 |
| Schaltzustand bei Szene 4 | list | ausschalten |
| Speicherfunktion für Szene 4 | list | Nein |
| Szene 5 aktivierbar durch Szenennummer (Szenennummer "0" = Szene deaktiviert) | unsignedInt 0…64 | 5 |
| Schaltzustand bei Szene 5 | list | ausschalten |
| Speicherfunktion für Szene 5 | list | Nein |
| Szene 6 aktivierbar durch Szenennummer (Szenennummer "0" = Szene deaktiviert) | unsignedInt 0…64 | 6 |
| Schaltzustand bei Szene 6 | list | ausschalten |
| Speicherfunktion für Szene 6 | list | Nein |
| Szene 7 aktivierbar durch Szenennummer (Szenennummer "0" = Szene deaktiviert) | unsignedInt 0…64 | 7 |
| Schaltzustand bei Szene 7 | list | ausschalten |
| Speicherfunktion für Szene 7 | list | Nein |
| Szene 8 aktivierbar durch Szenennummer (Szenennummer "0" = Szene deaktiviert) | unsignedInt 0…64 | 8 |
| Schaltzustand bei Szene 8 | list | ausschalten |
| Speicherfunktion für Szene 8 | list | Nein |
| Zählerart | list | Vorwärtszähler |
| Grenzwertvorgabe ? | list | nein |
| Startwertvorgabe ? | list | nein |
| Grenzwert (0...65535 h) | unsignedInt 0…65535 | 65535 |
| Startwert (0...65535 h) | unsignedInt 0…65535 | 65535 |
| Automatisches Senden des Zählwertes | list | bei Änderung um Intervallwert |
| Zählwertintervall (1...65535 h) | unsignedInt 1…65535 | 1 |
| Auswahl der Zusatzfunktion | list | keine Zusatzfunktion |
| Sperr_Freigabe | list | Aus |
| Zwang_Freigabe | list | Aus |
| Polarität Sperrobjekt | list | 0 = freigegeben; 1 = gesperrt |
| Verhalten am Ende der Zwangsstellung | list | keine Änderung des Schaltzustandes |
| Verhalten nach Busspannungswiederkehr | list | Zwangsstellung Ein, ausschalten |
| Verhalten zu Beginn der Sperrfunktion | list | einschalten |
| Verhalten am Ende der Sperrfunktion | list | nachgeführten Zustand einstellen |
| Verknüpfungsfunktion ? | list | Nein |
| Art der Verknüpfungsfunktion | list | ODER |
| Objektwert des Verknüpfungsobjekts nach Busspannungswiederkehr | list | 0 (AUS) |
| Objektwert des Verknüpfungsobjekts nach ETS-Download | list | 0 (AUS) |
| AUS_Freigabe | list | Aus |
Version history
| Application | App no | Fingerprint | First seen | Size | File |
|---|---|---|---|---|---|
| Schalten RM, VK, ZF 208811 1.1 latest | $2088 | F079 | 2026-11-25 | 167 KB | Download |
About this file
This is the official ETS product database for the Berker Schaltaktor 8fach 16A REG (75318004), published by the manufacturer in the KNX online catalog. To use it, open ETS, go to Catalogs → Import and choose the downloaded .knxprod file. The device then appears in your catalog and can be added to a project. Older versions are kept so existing projects can be matched to the application program they were commissioned with.
More from Berker
- Switch/shutter actuator 16/8gang 16A RMD 75310002
- Schaltaktor 2fach 16A REG 75312008
- Schaltaktor 4fach 16A REG 75314015
- Schaltaktor 4fach 16A C-Last REG 75314016
- Raumaktor 4/2fach 230 V REG 75314019
- 4-fold switch actuator 4A 230V AC 75314113
- 4-fold switch actuator 10A 230V AC 75314114
- 4-fold switch actuator 16A 230V AC 75314115
- 4-fold switch actuator 16A C-load 230V AC 75314116
- Schaltaktor 6fach 6A REG 75316002
- 6-fold switch actuator 16A 230V current monitoring 75316017
- 6-fold switch actuator 4A 230V AC 75316102