KNX Database
B.E.G. 93806 WS-VOC-HVAC-KNX

WS-VOC-HVAC-KNX 93806

B.E.G. · Order number 93806 · Sensors › HVAC

Download .knxprod VOC 1.0 · 250 KB

Product

ManufacturerB.E.G.
Product nameWS-VOC-HVAC-KNX
Order number93806
HardwareVOC
MediumTwisted Pair
Bus current (mA)12
Rail mountedNo
RegistrationCertified · 2020-04-30
Languagesfr-FR, en-US, de-DE, en-GB
Catalog entryM-00C8_H-20200420-1_HP-2A01-10-2FC4-O00C8_CI-93806-1
Fingerprint2FC4
SHA-2560ca49441d80629a9bb02a41c0ec0b180eb88ab3798379964cb255db54cb8b7b4
First seen2026-11-25
Markets43 markets

Application program: VOC 1.0

Application number$2A01
Version1.0
Mask versionMV-0705 (7.5)
KNX Data SecureNo
Parameters1527
Group objects345
Group objects (345)
NoNameFunctionSizeDPTFlags
0Object 11 BitCW
1Object 21 BitCW
2Object 31 BitCW
3Object 41 BitCW
4Object 51 BitCW
5Object 61 BitCW
6Object 71 BitCW
7Object 81 BitCW
8Object 91 BitCW
9Object 101 BitCW
10Object 111 BitCW
11Object 121 BitCW
12Object 131 BitCW
13Object 141 BitCW
14Object 151 BitCW
15Object 161 BitCW
16Object 171 BitCW
17Object 181 BitCW
18Object 191 BitCW
19Object 201 BitCW
20Object 212 BytesCW
20AS: Input (DPT 9.008)Air quality2 Bytes9.8 parts/million (ppm)CWTU
21Object 222 BytesCT
21AS: Output (DPT 9.008)Air quality2 Bytes9.8 parts/million (ppm)CT
22Object 232 BytesCW
22AL1: Input (DPT 9.008)Limit value2 Bytes9.8 parts/million (ppm)CW
23Object 241 BitCW
23AL1: Input (DPT 1.001)Lock1 Bit1.1 switchCW
24Object 254 BytesCT
24AL1: Output (DPT 1.001)Output1 Bit1.1 switchCT
24AL1: Output (DPT 5.001)Output1 Byte5.1 percentage (0..100%)CT
24AL1: Output (DPT 5.010)Output1 Byte5.10 counter pulses (0..255)CT
24AL1: Output (DPT 6.010)Output1 Byte6.10 counter pulses (-128..127)CT
24AL1: Output (DPT 9.x)Output2 BytesDPT.9CT
24AL1: Output (DPT 7.x)Output2 BytesDPT.7CT
24AL1: Output (DPT 8.x)Output2 BytesDPT.8CT
24AL1: Output (DPT 14.x)Output4 BytesDPT.14CT
24AL1: Output (DPT 12.x)Output4 BytesDPT.12CT
24AL1: Output (DPT 13.x)Output4 BytesDPT.13CT
25Object 262 BytesCW
25AL2: Input (DPT 9.008)Limit value2 Bytes9.8 parts/million (ppm)CW
26Object 271 BitCW
26AL2: Input (DPT 1.001)Lock1 Bit1.1 switchCW
27Object 284 BytesCT
27AL2: Output (DPT 1.001)Output1 Bit1.1 switchCT
27AL2: Output (DPT 5.001)Output1 Byte5.1 percentage (0..100%)CT
27AL2: Output (DPT 5.010)Output1 Byte5.10 counter pulses (0..255)CT
27AL2: Output (DPT 6.010)Output1 Byte6.10 counter pulses (-128..127)CT
27AL2: Output (DPT 9.x)Output2 BytesDPT.9CT
27AL2: Output (DPT 7.x)Output2 BytesDPT.7CT
27AL2: Output (DPT 8.x)Output2 BytesDPT.8CT
27AL2: Output (DPT 14.x)Output4 BytesDPT.14CT
27AL2: Output (DPT 12.x)Output4 BytesDPT.12CT
27AL2: Output (DPT 13.x)Output4 BytesDPT.13CT
28Object 292 BytesCW
28AL3: Input (DPT 9.008)Limit value2 Bytes9.8 parts/million (ppm)CW
29Object 301 BitCW
29AL3: Input (DPT 1.001)Lock1 Bit1.1 switchCW
30Object 314 BytesCT
30AL3: Output (DPT 1.001)Output1 Bit1.1 switchCT
30AL3: Output (DPT 5.001)Output1 Byte5.1 percentage (0..100%)CT
30AL3: Output (DPT 5.010)Output1 Byte5.10 counter pulses (0..255)CT
30AL3: Output (DPT 6.010)Output1 Byte6.10 counter pulses (-128..127)CT
30AL3: Output (DPT 9.x)Output2 BytesDPT.9CT
30AL3: Output (DPT 7.x)Output2 BytesDPT.7CT
30AL3: Output (DPT 8.x)Output2 BytesDPT.8CT
30AL3: Output (DPT 14.x)Output4 BytesDPT.14CT
30AL3: Output (DPT 12.x)Output4 BytesDPT.12CT
30AL3: Output (DPT 13.x)Output4 BytesDPT.13CT
31Object 322 BytesCW
31AL4: Input (DPT 9.008)Limit value2 Bytes9.8 parts/million (ppm)CW
32Object 331 BitCW
32AL4: Input (DPT 1.001)Lock1 Bit1.1 switchCW
33Object 344 BytesCT
33AL4: Output (DPT 1.001)Output1 Bit1.1 switchCT
33AL4: Output (DPT 5.001)Output1 Byte5.1 percentage (0..100%)CT
33AL4: Output (DPT 5.010)Output1 Byte5.10 counter pulses (0..255)CT
33AL4: Output (DPT 6.010)Output1 Byte6.10 counter pulses (-128..127)CT
33AL4: Output (DPT 9.x)Output2 BytesDPT.9CT
33AL4: Output (DPT 7.x)Output2 BytesDPT.7CT
33AL4: Output (DPT 8.x)Output2 BytesDPT.8CT
33AL4: Output (DPT 14.x)Output4 BytesDPT.14CT
33AL4: Output (DPT 12.x)Output4 BytesDPT.12CT
33AL4: Output (DPT 13.x)Output4 BytesDPT.13CT
34Object 351 BitCW
35Object 361 BitCW
36Object 371 BitCW
37Object 381 BitCW
38Object 391 BitCW
39Object 401 BitCW
39AR: Input (DPT 1.007)Set value Step (plus/minus)1 Bit1.7 stepCW
40Object 412 BytesCW
40AR: Input (DPT 9.008)Set value absolute2 Bytes9.8 parts/million (ppm)CW
41Object 421 BitCW
41AR: Input (DPT 1.015)Set value reset1 Bit1.15 resetCW
42Object 431 BitCW
42AR: Input (DPT 1.001)Lock (priority 1)1 Bit1.1 switchCW
43Object 441 BitCW
43AR: Input (DPT 1.001)Day/Night (priority 2)1 Bit1.1 switchCW
44Object 452 BytesCT
44AR: Output (DPT 9.008)Set value2 Bytes9.8 parts/million (ppm)CT
45Object 461 ByteCT
45AR: Output (DPT 5.001)Ventilation1 Byte5.1 percentage (0..100%)CT
45AR: Output (DPT 1.001)Ventilation1 Bit1.1 switchCT
45AR: Output (DPT 1.001)Ventilation Stage 11 Bit1.1 switchCT
46Object 471 BitCT
46AR: Output (DPT 1.001)Ventilation Stage 21 Bit1.1 switchCT
47Object 481 BitCT
47AR: Output (DPT 1.001)Ventilation Stage 31 Bit1.1 switchCT
48Object 491 BitCT
48AR: Output (DPT 1.001)Ventilation Stage 41 Bit1.1 switchCT
49Object 501 BitCW
50Object 511 BitCW
51Object 521 BitCW
52Object 531 BitCW
53Object 541 BitCW
54Object 552 BytesCW
54TS: Input (DPT 9.001)Temperature2 Bytes9.1 temperature (°C)CWTU
55Object 562 BytesCT
55TS: Output (DPT 9.001)Temperature2 Bytes9.1 temperature (°C)CT
56Object 572 BytesCW
56TL1: Input (DPT 9.001)Limit value2 Bytes9.1 temperature (°C)CW
57Object 581 BitCW
57TL1: Input (DPT 1.001)Lock1 Bit1.1 switchCW
58Object 594 BytesCT
58TL1: Output (DPT 1.001)Output1 Bit1.1 switchCT
58TL1: Output (DPT 5.001)Output1 Byte5.1 percentage (0..100%)CT
58TL1: Output (DPT 5.010)Output1 Byte5.10 counter pulses (0..255)CT
58TL1: Output (DPT 6.010)Output1 Byte6.10 counter pulses (-128..127)CT
58TL1: Output (DPT 9.x)Output2 BytesDPT.9CT
58TL1: Output (DPT 7.x)Output2 BytesDPT.7CT
58TL1: Output (DPT 8.x)Output2 BytesDPT.8CT
58TL1: Output (DPT 14.x)Output4 BytesDPT.14CT
58TL1: Output (DPT 12.x)Output4 BytesDPT.12CT
58TL1: Output (DPT 13.x)Output4 BytesDPT.13CT
59Object 602 BytesCW
59TL2: Input (DPT 9.001)Limit value2 Bytes9.1 temperature (°C)CW
60Object 611 BitCW
60TL2: Input (DPT 1.001)Lock1 Bit1.1 switchCW
61Object 624 BytesCT
61TL2: Output (DPT 1.001)Output1 Bit1.1 switchCT
61TL2: Output (DPT 5.001)Output1 Byte5.1 percentage (0..100%)CT
61TL2: Output (DPT 5.010)Output1 Byte5.10 counter pulses (0..255)CT
61TL2: Output (DPT 6.010)Output1 Byte6.10 counter pulses (-128..127)CT
61TL2: Output (DPT 9.x)Output2 BytesDPT.9CT
61TL2: Output (DPT 7.x)Output2 BytesDPT.7CT
61TL2: Output (DPT 8.x)Output2 BytesDPT.8CT
61TL2: Output (DPT 14.x)Output4 BytesDPT.14CT
61TL2: Output (DPT 12.x)Output4 BytesDPT.12CT
61TL2: Output (DPT 13.x)Output4 BytesDPT.13CT
62Object 632 BytesCW
62TL3: Input (DPT 9.001)Limit value2 Bytes9.1 temperature (°C)CW
63Object 641 BitCW
63TL3: Input (DPT 1.001)Lock1 Bit1.1 switchCW
64Object 654 BytesCT
64TL3: Output (DPT 1.001)Output1 Bit1.1 switchCT
64TL3: Output (DPT 5.001)Output1 Byte5.1 percentage (0..100%)CT
64TL3: Output (DPT 5.010)Output1 Byte5.10 counter pulses (0..255)CT
64TL3: Output (DPT 6.010)Output1 Byte6.10 counter pulses (-128..127)CT
64TL3: Output (DPT 9.x)Output2 BytesDPT.9CT
64TL3: Output (DPT 7.x)Output2 BytesDPT.7CT
64TL3: Output (DPT 8.x)Output2 BytesDPT.8CT
64TL3: Output (DPT 14.x)Output4 BytesDPT.14CT
64TL3: Output (DPT 12.x)Output4 BytesDPT.12CT
64TL3: Output (DPT 13.x)Output4 BytesDPT.13CT
65Object 662 BytesCW
65TL4: Input (DPT 9.001)Limit value2 Bytes9.1 temperature (°C)CW
66Object 671 BitCW
66TL4: Input (DPT 1.001)Lock1 Bit1.1 switchCW
67Object 684 BytesCT
67TL4: Output (DPT 1.001)Output1 Bit1.1 switchCT
67TL4: Output (DPT 5.001)Output1 Byte5.1 percentage (0..100%)CT
67TL4: Output (DPT 5.010)Output1 Byte5.10 counter pulses (0..255)CT
67TL4: Output (DPT 6.010)Output1 Byte6.10 counter pulses (-128..127)CT
67TL4: Output (DPT 9.x)Output2 BytesDPT.9CT
67TL4: Output (DPT 7.x)Output2 BytesDPT.7CT
67TL4: Output (DPT 8.x)Output2 BytesDPT.8CT
67TL4: Output (DPT 14.x)Output4 BytesDPT.14CT
67TL4: Output (DPT 12.x)Output4 BytesDPT.12CT
67TL4: Output (DPT 13.x)Output4 BytesDPT.13CT
68Object 691 BitCW
69Object 701 BitCW
70Object 711 BitCW
71Object 721 BitCW
72Object 731 BitCW
73Object 741 BitCW
73TC: Input (DPT 1.007)Set value step (plus/minus)1 Bit1.7 stepCW
74Object 752 BytesCW
74TC: Input (DPT 9.001)Set value relative2 Bytes9.1 temperature (°C)CW
75Object 762 BytesCW
75TC: Input (DPT 9.001)Set value absolute2 Bytes9.1 temperature (°C)CW
76Object 771 BitCW
76TC: Input (DPT 1.015)Set value reset1 Bit1.15 resetCW
77Object 782 BytesCW
77TC: Input (DPT 9.001)Outdoor temperature2 Bytes9.1 temperature (°C)CW
78Object 792 BytesCW
78TC: Input (DPT 9.001)Temp. Condensate prevention2 Bytes9.1 temperature (°C)CW
79Object 801 BitCW
79TC: Input (DPT 1.001)Dewpoint/Lock (priority 1)1 Bit1.1 switchCW
80Object 811 ByteCW
80TC: Input (DPT 1.001)Absence (priority 2)1 Bit1.1 switchCW
80TC: Input (DPT 20.102)HVAC (priority 2)1 Byte20.102 HVAC modeCW
81Object 821 ByteCW
81TC: Input (DPT 1.001)Building protection (priority 3)1 Bit1.1 switchCW
81TC: Input (DPT 20.102)HVAC delayed (priority 3)1 Byte20.102 HVAC modeCW
82Object 831 ByteCW
82TC: Input (DPT 1.001)Comfort extension (priority 4)1 Bit1.1 switchCW
82TC: Input (DPT 20.102)HVAC für Duration (priority 4)1 Byte20.102 HVAC modeCW
83Object 841 ByteCW
83TC: Input (DPT 1.001)Comfort (priority 5)1 Bit1.1 switchCW
83TC: Input (DPT 20.102)HVAC (priority 5)1 Byte20.102 HVAC modeCW
84Object 851 ByteCW
84TC: Input (DPT 1.001)Night (priority 6)1 Bit1.1 switchCW
84TC: Input (DPT 20.102)HVAC (priority 6)1 Byte20.102 HVAC modeCW
85Object 861 BitCW
85TC: Input (DPT 1.100)Switchover Heating/Cooling1 Bit1.100 heating/coolingCW
86Object 872 BytesCT
86TC: Output (DPT 9.001)Set value2 Bytes9.1 temperature (°C)CT
87Object 881 BitCT
87TC: Output (DPT 1.001)Feedback Bit1 Bit1.1 switchCT
88Object 892 BytesCT
88TC: Output (DPT 22.101)Feedback RHCC2 Bytes22.101 RHCC statusCT
89Object 901 ByteCT
89TC: Output Feedback Byte1 ByteCT
90Object 912 BytesCT
90TC: Output (DPT 9.001)Dewpoint2 Bytes9.1 temperature (°C)CT
91Object 921 ByteCT
91TC: Output (DPT 5.001)Heating Stage 11 Byte5.1 percentage (0..100%)CT
91TC: Output (DPT 1.001)Heating Stage 11 Bit1.1 switchCT
92Object 931 ByteCT
92TC: Output (DPT 5.001)Heating Stage 21 Byte5.1 percentage (0..100%)CT
92TC: Output (DPT 1.001)Heating Stage 21 Bit1.1 switchCT
93Object 941 ByteCT
93TC: Output (DPT 5.001)Cooling Stage 11 Byte5.1 percentage (0..100%)CT
93TC: Output (DPT 1.001)Cooling Stage 11 Bit1.1 switchCT
94Object 951 ByteCT
94TC: Output (DPT 5.001)Cooling Stage 21 Byte5.1 percentage (0..100%)CT
94TC: Output (DPT 1.001)Cooling Stage 21 Bit1.1 switchCT
95Object 961 BitCW
96Object 971 BitCW
97Object 981 BitCW
98Object 991 ByteCW
98HS: Input (DPT 5.001)Humidity1 Byte5.1 percentage (0..100%)CWTU
98HS: Input (DPT 9.007)Humidity2 Bytes9.7 humidity (%)CWTU
99Object 1001 ByteCT
99HS: Output (DPT 5.001)Humidity1 Byte5.1 percentage (0..100%)CT
99HS: Output (DPT 9.007)Humidity2 Bytes9.7 humidity (%)CT
100Object 1011 ByteCW
100HL1: Input (DPT 5.001)Limit value1 Byte5.1 percentage (0..100%)CW
100HL1: Input (DPT 9.007)Limit value2 Bytes9.7 humidity (%)CW
101Object 1021 BitCW
101HL1: Input (DPT 1.001)Lock1 Bit1.1 switchCW
102Object 1034 BytesCT
102HL1: Output (DPT 1.001)Output1 Bit1.1 switchCT
102HL1: Output (DPT 5.001)Output1 Byte5.1 percentage (0..100%)CT
102HL1: Output (DPT 5.010)Output1 Byte5.10 counter pulses (0..255)CT
102HL1: Output (DPT 6.010)Output1 Byte6.10 counter pulses (-128..127)CT
102HL1: Output (DPT 9.x)Output2 BytesDPT.9CT
102HL1: Output (DPT 7.x)Output2 BytesDPT.7CT
102HL1: Output (DPT 8.x)Output2 BytesDPT.8CT
102HL1: Output (DPT 14.x)Output4 BytesDPT.14CT
102HL1: Output (DPT 12.x)Output4 BytesDPT.12CT
102HL1: Output (DPT 13.x)Output4 BytesDPT.13CT
103Object 1041 ByteCW
103HL2: Input (DPT 5.001)Limit value1 Byte5.1 percentage (0..100%)CW
103HL2: Input (DPT 9.007)Limit value2 Bytes9.7 humidity (%)CW
104Object 1051 BitCW
104HL2: Input (DPT 1.001)Lock1 Bit1.1 switchCW
105Object 1064 BytesCT
105HL2: Output (DPT 1.001)Output1 Bit1.1 switchCT
105HL2: Output (DPT 5.001)Output1 Byte5.1 percentage (0..100%)CT
105HL2: Output (DPT 5.010)Output1 Byte5.10 counter pulses (0..255)CT
105HL2: Output (DPT 6.010)Output1 Byte6.10 counter pulses (-128..127)CT
105HL2: Output (DPT 9.x)Output2 BytesDPT.9CT
105HL2: Output (DPT 7.x)Output2 BytesDPT.7CT
105HL2: Output (DPT 8.x)Output2 BytesDPT.8CT
105HL2: Output (DPT 14.x)Output4 BytesDPT.14CT
105HL2: Output (DPT 12.x)Output4 BytesDPT.12CT
105HL2: Output (DPT 13.x)Output4 BytesDPT.13CT
106Object 1071 ByteCW
106HL3: Input (DPT 5.001)Limit value1 Byte5.1 percentage (0..100%)CW
106HL3: Input (DPT 9.007)Limit value2 Bytes9.7 humidity (%)CW
107Object 1081 BitCW
107HL3: Input (DPT 1.001)Lock1 Bit1.1 switchCW
108Object 1094 BytesCT
108HL3: Output (DPT 1.001)Output1 Bit1.1 switchCT
108HL3: Output (DPT 5.001)Output1 Byte5.1 percentage (0..100%)CT
108HL3: Output (DPT 5.010)Output1 Byte5.10 counter pulses (0..255)CT
108HL3: Output (DPT 6.010)Output1 Byte6.10 counter pulses (-128..127)CT
108HL3: Output (DPT 9.x)Output2 BytesDPT.9CT
108HL3: Output (DPT 7.x)Output2 BytesDPT.7CT
108HL3: Output (DPT 8.x)Output2 BytesDPT.8CT
108HL3: Output (DPT 14.x)Output4 BytesDPT.14CT
108HL3: Output (DPT 12.x)Output4 BytesDPT.12CT
108HL3: Output (DPT 13.x)Output4 BytesDPT.13CT
109Object 1101 ByteCW
109HL4: Input (DPT 5.001)Limit value1 Byte5.1 percentage (0..100%)CW
109HL4: Input (DPT 9.007)Limit value2 Bytes9.7 humidity (%)CW
110Object 1111 BitCW
110HL4: Input (DPT 1.001)Lock1 Bit1.1 switchCW
111Object 1124 BytesCT
111HL4: Output (DPT 1.001)Output1 Bit1.1 switchCT
111HL4: Output (DPT 5.001)Output1 Byte5.1 percentage (0..100%)CT
111HL4: Output (DPT 5.010)Output1 Byte5.10 counter pulses (0..255)CT
111HL4: Output (DPT 6.010)Output1 Byte6.10 counter pulses (-128..127)CT
111HL4: Output (DPT 9.x)Output2 BytesDPT.9CT
111HL4: Output (DPT 7.x)Output2 BytesDPT.7CT
111HL4: Output (DPT 8.x)Output2 BytesDPT.8CT
111HL4: Output (DPT 14.x)Output4 BytesDPT.14CT
111HL4: Output (DPT 12.x)Output4 BytesDPT.12CT
111HL4: Output (DPT 13.x)Output4 BytesDPT.13CT
112Object 1131 BitCW
113Object 1141 BitCW
114Object 1151 BitCW
115Object 1161 BitCW
116Object 1171 BitCW
117Object 1181 BitCW
117HC: Input (DPT 1.007)Set value Step (plus/minus)1 Bit1.7 stepCW
118Object 1191 ByteCW
118HC: Input (DPT 6.001)Set value relative1 Byte6.1 percentage (-128..127%)CW
119Object 1201 ByteCW
119HC: Input (DPT 5.001)Set value absolute1 Byte5.1 percentage (0..100%)CW
119HC: Input (DPT 9.007)Set value absolute2 Bytes9.7 humidity (%)CW
120Object 1211 BitCW
120HC: Input (DPT 1.015)Set value reset1 Bit1.15 resetCW
121Object 1221 BitCW
121HC: Input (DPT 1.001)Lock (priority 1)1 Bit1.1 switchCW
122Object 1231 BitCW
122HC: Input (DPT 1.001)Day/Night (priority 2)1 Bit1.1 switchCW
123Object 1241 BitCW
123HC: Input (DPT 1.001)Switchover Humidify(0)/Dehumidify(1)1 Bit1.1 switchCW
124Object 1251 ByteCT
124HC: Output (DPT 5.001)Set value1 Byte5.1 percentage (0..100%)CT
124HC: Output (DPT 9.007)Set value2 Bytes9.7 humidity (%)CT
125Object 1261 ByteCT
125HC: Output (DPT 5.001)Dehumidify1 Byte5.1 percentage (0..100%)CT
125HC: Output (DPT 1.001)Dehumidify1 Bit1.1 switchCT
126Object 1271 ByteCT
126HC: Output (DPT 5.001)Humidify1 Byte5.1 percentage (0..100%)CT
126HC: Output (DPT 1.001)Humidify1 Bit1.1 switchCT
127Object 1281 BitCW
128Object 1291 BitCW
129Object 1301 BitCW
130Object 1311 BitCW
131Object 1321 BitCW
Parameters (282)
ParameterTypeDefault
Basic settingslistDummy
Start delay in secondsunsignedInt 0…2550
Air qualitylistDummy
Measurement procedurelistCO2 equivalent
Traffic lightlistactivated
Limit value 1listdeactivated
Limit value 2listdeactivated
Limit value 3listdeactivated
Limit value 4listdeactivated
Controllerlistdeactivated
TemperaturelistDummy
Additional stagelistdeactivated
HumiditylistDummy
Format of Humidity communication objectlist1Byte (DPT 5.001)
------------------------------listDummy
AS: Air quality sensorlistDummy
Correction in ppmsignedInt -500…5000
Weighting internal sensor (0 = not used)unsignedInt 0…101
Weighting communication object (0 = not used)unsignedInt 0…100
Read out communication objectlistactivated
Monitoring of the communication objectlistactivated
Monitoring time in minutesunsignedInt 1…25510
send valueliston change
Changelistabsolute
Change in ppmunsignedInt 5…100010
Change in %unsignedInt 1…5010
Cycle time in minutesunsignedInt 0…25510
Cycle time in secondsunsignedInt 0…2550
Restrict sending rangelistdeactivated
Minimum value in ppmunsignedInt 0…50000
Maximum value in ppmunsignedInt 0…50005000
AS: Traffic lightlistDummy
Use range red, yellow, greenlistactivated
Red >= value in ppmunsignedInt 0…50001200
Red >= value in %unsignedInt 0…10070
Red >= value in 0,1°CsignedInt -500…500260
Yellow >= value in ppmunsignedInt 0…5000800
Yellow >= value in %unsignedInt 0…10060
Yellow >= value in 0,1°CsignedInt -500…500220
Use range green, yellow, redlistdeactivated
Yellow <= value in %unsignedInt 0…10040
Yellow <= value in 0,1°CsignedInt -500…500200
Red <= value in %unsignedInt 0…10030
Red <= value in 0,1°CsignedInt -500…500160
Hysteresis in ppmunsignedInt 1…1000100
Hysteresis in %unsignedInt 1…502
Hysteresis in 0,1 KunsignedInt 1…502
AL: Air quality Limit value 1listDummy
Limit value in ppmunsignedInt 0…5000600
Limit valuelistdetermined by parameter
Value by ETS downloadlistoverwritable
Hysteresislistabsolute
Hysteresis in %unsignedInt 1…5010
Activation / deactivationlistActive >= value + hysteresis Deactive <= value - hysteresis
Delay before activation in minunsignedInt 0…2555
Delay before deactivation in minunsignedInt 0…2555
Sending behaviourliston change
Output formatlist1 bit (DPT 1.001)
Send value on activationlistactivated
valuesignedInt 0…11
value in %signedInt 0…100100
valuesignedInt 0…255255
valuesignedInt -128…127127
valuesignedInt -671088…6707601000
valuesignedInt 0…655351000
valuesignedInt -32768…327671000
valuesignedInt -2147483647…21474836461000
valuesignedInt 0…21474836461000
Send value on deactivationlistactivated
valuesignedInt 0…10
value in %signedInt 0…1000
valuesignedInt 0…2550
valuesignedInt -128…127-128
valuesignedInt -671088…6707600
valuesignedInt 0…655350
valuesignedInt -32768…32767-1000
valuesignedInt -2147483647…21474836460
valuesignedInt 0…21474836460
valuesignedInt -2147483647…2147483646-1000
Locklistdeactivated
Lock withlistOn telegram
Behaviour when the lock is activatedlistsend value
Behaviour when the lock is deactivatedlistunlock and send current status
During bus voltage recoverylistnot locked
AL: Air quality Limit value 2listDummy
Limit value in ppmunsignedInt 0…5000800
AL: Air quality Limit value 3listDummy
Limit value in ppmunsignedInt 0…50001000
AL: Air quality Limit value 4listDummy
Limit value in ppmunsignedInt 0…50001200
AR: Air quality regulatorlistDummy
Modelistregulation
Initialisation behaviourlistuse initialisation values
- Operating mode switchoverlistDummy
Lock with (priority 1)listOn telegram
Initialisation value LocklistOff telegram
Day with (priority 2)listOn telegram
Initialisation value daylistOn telegram
- Set valueslistDummy
- StageslistDummy
Day in ppmunsignedInt 0…5000600
Stage 1 in ppmunsignedInt 0…5000600
Night in ppmunsignedInt 0…5000700
Stage 2 in ppmunsignedInt 0…5000800
Stage 3 in ppmunsignedInt 0…50001000
Stage 4 in ppmunsignedInt 0…50001200
Hysteresis in ppmunsignedInt 100…2000100
Switchover time in minunsignedInt 0…2551
Output in %listactivated
- Set value adjustmentlistDummy
- Control variableslistDummy
Maximum positive offset in ppmunsignedInt 0…1000200
Cyclical sending in minunsignedInt 0…600
ModelistAlternating operation
Maximum negative offset in ppmunsignedInt 0…1000200
Stage 1 in %unsignedInt 0…10025
Adjustment via potentiometerlistdeactivated
Stage 2 in %unsignedInt 0…10050
Day Minimum StageunsignedInt 0…41
Offset via step objectunsignedInt 10…10050
Stage 3 in %unsignedInt 0…10075
Day Maximum StageunsignedInt 0…44
Stage 4 in %unsignedInt 0…100100
Night Minimum StageunsignedInt 0…41
Night Maximum StageunsignedInt 0…42
Send value when lockedlistactivated
Locking valueunsignedInt 0…40
- FeedbacklistDummy
Send set valuelistdeactivated
Change in ppmunsignedInt 10…10010
Cycle time in minutesunsignedInt 1…2555
- ControllerlistDummy
Operating senselistnormal
Controller typelistPI continuous
P-component in 0.1 KunsignedInt 100…2000800
I-component in minunsignedInt 0…25515
Change for sending in %unsignedInt 1…103
Day Switch-off value in %unsignedInt 0…10010
Day Minimum in %unsignedInt 0…10010
Day Switch-on value in %unsignedInt 0…100100
Day Maximum in %unsignedInt 0…100100
Night Switch-off value in %unsignedInt 0…10010
Night Minimum in %unsignedInt 0…10010
Night Switch-on value in %unsignedInt 0…10030
Night Maximum in %unsignedInt 0…10030
Locking value in %unsignedInt 0…1000
Locking valuelistSwitch off
TS: Temperature sensorlistDummy
Correction in 0,1 KsignedInt -128…1270
Send valueliston change
Change in 0.1 KunsignedInt 1…25510
Minimum value in °CunsignedInt 0…500
Maximum value in °CunsignedInt 0…5040
TL: Temperature Limit value 1listDummy
Limit value in 0,1 KsignedInt -500…500210
Hysteresis in 0,1 KunsignedInt 1…25510
Activation / deactivationlistActive <= value - hysteresis Deactive >= value + hysteresis
Delay before activation in minutesunsignedInt 0…2555
Delay before deactivation in minutesunsignedInt 0…2555
Cycle time in minutesunsignedInt 0…25510
Cycle time in secondsunsignedInt 0…2550
TL: Temperature Limit value 2listDummy
Limit value in 0,1 KsignedInt -500…500190
TL: Temperature Limit value 3listDummy
Limit value in 0,1 KsignedInt -500…500170
TL: Temperature Limit value 4listDummy
Limit value in 0,1 KsignedInt -500…50070
TC: Temperature controllerlistDummy
Controller typelistHeating
Switchover between heating and coolinglistautomatically
Hysteresis between heating and cooling in KunsignedInt 1…103
Switchover time in hoursunsignedInt 0…2550
Switchover time in minutesunsignedInt 0…25530
-Dew pointlistDummy
Dew point calculationlistdeactivated
Lead in KunsignedInt 0…50
Hysteresis for deactivation in KunsignedInt 1…51
Locking after comparison with CO 78 "Temperature condensate prevention".listdeactivated
Send dew pointlistdeactivated
Change in 0.1 KunsignedInt 1…1005
Operating mode 1 Initialisation value (Priority 1 "Dew point/Lockout")listdeactivated
Control operating mode 2 (Priority 2 "Absence")listvia binary format
Initialisation valuelistdeactivated
Initialisation valuelistAutomatic
Status on activationlistEconomy
Control operating mode 3 (Priority 3 "Building protection")listvia binary format
Delay before activation in minutesunsignedInt 0…2550
Control operating mode 4 (Priority 4 "Comfort extension")listvia binary format
Duration in hoursunsignedInt 0…2554
Duration in minutesunsignedInt 0…2550
Control operating mode 5 (Priority 5 "Comfort")listvia binary format
Control operating mode 6 (Priority 6 "Night")listvia binary format
Cooling Heat protection in 0,1°CunsignedInt 0…500350
Cooling Economy in 0,1°CunsignedInt 0…500250
Cooling Standby in 0,1°CunsignedInt 0…500230
Cooling Comfort in 0,1°CunsignedInt 0…500210
Heating Comfort in 0,1°CunsignedInt 0…500210
Heating Standby in 0,1°CunsignedInt 0…500190
Heating Economy in 0,1°CunsignedInt 0…500170
Heating Frost protection in 0,1°CunsignedInt 0…50070
Maximum positive offset in KunsignedInt 0…103
Maximum negative offset in KunsignedInt 0…103
Offset via step objectlist1 K
Set value limitation by means of outdoor temperaturelistdeactivated
Difference to outdoor temperature in KunsignedInt 1…103
Bit Feedbacklistdeactivated
InformationlistComfort
RHCC feedbacklistdeactivated
Byte feedbacklistdeactivated
- Heating controllistDummy
Heating systemlistfloor heating (5K / 240 min)
P-component in 0.1 KunsignedInt 1…25550
Hysteresis in 0,1 KunsignedInt 5…305
I-component in minunsignedInt 0…255150
Valve protection every x daysunsignedInt 0…300
Valve protection End position for x minutesunsignedInt 1…304
Controller typelist2-step switching
Stage distance in 0.1 KunsignedInt 10…10020
- Heating control variableslistDummy
Cycle time PWM in minunsignedInt 1…6015
Cycle time in minutesunsignedInt 0…600
Switch-off value in %unsignedInt 0…1000
Min range 0 to x in %unsignedInt 0…1000
Switch-on value in %unsignedInt 0…100100
Minimum value in %unsignedInt 0…1000
Send value upon lockinglistactivated
Max range from x to 100 in %unsignedInt 0…100100
Maximum value in %unsignedInt 0…100100
Locking valueunsignedInt 0…1000
- Heating control variables - additional stagelistDummy
Switch-on value in %unsignedInt 0…100100
- Cooling controllistDummy
Cooling systemlistcooling ceiling (5 K / 240 min)
P-component in 0.1 KunsignedInt 1…25540
I-component in minunsignedInt 0…25590
- Cooling control variableslistDummy
Use output also for heatinglistdeactivated
- Cooling control variables - additional stagelistDummy
HS: Humidity sensorlistDummy
Correction in %signedInt -50…500
Change in %unsignedInt 1…502
cycle time in minunsignedInt 0…25510
Minimum value in ppmunsignedInt 0…1000
Maximum value in ppmunsignedInt 0…100100
HS: Traffic lightlistDummy
HL: Humidity Limit value 1listDummy
Limit value in %unsignedInt 0…10060
Hysteresis in %unsignedInt 1…505
Activation / deactivationlistActive >= value Deactive <= value - hysteresis
HL: Humidity Limit value 2listDummy
Limit value in %unsignedInt 0…10065
HL: Humidity Limit value 3listDummy
Limit value in %unsignedInt 0…10070
HL: Humidity Limit value 4listDummy
Limit value in %unsignedInt 0…10075
HC: Humidity controllerlistDummy
Control modelistdehumidify
Switchover between dehumidify and humidifylistautomatically
Hysteresis for switchover in %unsignedInt 1…203
Humidify night in %unsignedInt 0…10040
Humidify day in %unsignedInt 0…10050
Dehumidify day in %unsignedInt 0…10050
Dehumidify night in %unsignedInt 0…10060
Maximum positive offset in %unsignedInt 0…505
Maximum negative offset in %unsignedInt 0…505
Offset via step objectunsignedInt 1…201
change in %unsignedInt 1…205
cycle time in minunsignedInt 1…2555
- Dehumidifying controllistDummy
P-component in %unsignedInt 1…10020
Hysteresis in %unsignedInt 1…205
- Control variables DehumidifylistDummy
Day Switch-off value in %unsignedInt 0…1000
Day Minimum in %unsignedInt 0…1000
Day Switch-on value in %unsignedInt 0…100100
Night Switch-off value in %unsignedInt 0…1000
Night Minimum in %unsignedInt 0…1000
Night Switch-on value in %unsignedInt 0…100100
Night Maximum in %unsignedInt 0…100100
- Humidification controllistDummy
- Control variables HumidifylistDummy
Use output also for dehumidifylistdeactivated

Version history

ApplicationApp noFingerprintFirst seenSizeFile
VOC 1.0 latest$2A012FC42026-11-25250 KBDownload

About this file

This is the official ETS product database for the B.E.G. WS-VOC-HVAC-KNX (93806), published by the manufacturer in the KNX online catalog. To use it, open ETS, go to Catalogs → Import and choose the downloaded .knxprod file. The device then appears in your catalog and can be added to a project. Older versions are kept so existing projects can be matched to the application program they were commissioned with.