| Start delay
in seconds | unsignedInt 0…120 | 5 |
| Start-up telegram (heartbeat) | list | deactivated |
| Cycle time in minutes | unsignedInt 1…120 | 60 |
| Central switching | list | deactivated |
| Collective feedback | list | deactivated |
| Reset actuator to original download parameters | list | deactivated |
| First repeat block | list | activated |
| Distance to previous transmission requests | time | 1000 |
| Distance in block | time | 500 |
| Switching channel uses repeat block | list | activated |
| Switching cycle counter uses repeat block | list | deactivated |
| Operating hours counter uses repeat block | list | deactivated |
| Second repeat block | list | activated |
| Distance to previous transmission requests | time | 5000 |
| Result of basic function after bus voltage return | list | "0" |
| Operating hours counter | list | deactivated |
| Switching cycle counter | list | deactivated |
| Relay status at which counting is to take place | list | closed |
| Operating hours limit value in hours | unsignedInt 1…65535 | 8760 |
| Overwrite operating hours limit value | list | deactivated |
| Changed operating hours limit value by ETS download or object Reset | list | overwriteable |
| Reset current operating counter value by ETS download or object Reset | list | deactivated |
| Send operating hours | list | upon modification |
| Modification in hours | unsignedInt 1…24 | 1 |
| Send message Operating hours reached | list | upon modification |
| Cycle time | time | 86400 |
| Value of feedback object | list | "0" = not reached / "1" = reached |
| Counted | list | Switch-on and switch-off operations |
| Switching cycle counter limit value | unsignedInt 1…100000 | 10000 |
| Overwrite switching cycle counter limit value | list | deactivated |
| Changed switching cycle counter limit value by ETS download or object Reset | list | overwriteable |
| Current switching cycle counter value can be reset by ETS download or object Reset | list | deactivated |
| Send counter reading | list | upon modification |
| Cycle time
in hours | unsignedInt 1…24 | 24 |
| Modification in steps | unsignedInt 10…10000 | 1000 |
| Send message Switching cycles reached | list | upon modification |
| Value of input event
when switching object = "1" | list | "1" |
| Value of input event
when Switching object = "0" | list | "0" |
| Scene function | list | deactivated |
| Value of input event
when central object = "1" | list | "1" |
| Value of input event
when Central object = "0" | list | "0" |
| Scene A | list | deactivated |
| Scene number for scene A | unsignedInt 1…64 | 1 |
| Value of input event for scene A | list | "1" |
| Scene B | list | deactivated |
| Scene number for scene B | unsignedInt 1…64 | 2 |
| Value of input event for scene B | list | "1" |
| Scene C | list | deactivated |
| Scene number for scene C | unsignedInt 1…64 | 3 |
| Value of input event for scene C | list | "1" |
| Scene D | list | deactivated |
| Scene number for scene D | unsignedInt 1…64 | 4 |
| Value of input event for scene D | list | "1" |
| Scene E | list | deactivated |
| Scene number for scene E | unsignedInt 1…64 | 5 |
| Value of input event for scene E | list | "1" |
| Scene F | list | deactivated |
| Scene number for scene F | unsignedInt 1…64 | 6 |
| Value of input event for scene F | list | "1" |
| Scene G | list | deactivated |
| Scene number for scene G | unsignedInt 1…64 | 7 |
| Value of input event for scene G | list | "1" |
| Scene H | list | deactivated |
| Scene number for scene H | unsignedInt 1…64 | 8 |
| Value of input event for scene H | list | "1" |
| Stored scenes by ETS download or object Reset | list | overwriteable |
| The end of the learning process is signalled by a switching cycle | list | activated |
| Basic function | list | Switching |
| Switch-on delay
(switching, scene, central function) | list | deactivated |
| Switch-off delay
(switching, scene, central function) | list | deactivated |
| Delay time | time | 60 |
| Switch-on delay | list | not retriggerable |
| Switching object takes effect on | list | delayed |
| Central object takes effect on | list | instantaneous |
| Scene object takes effect on | list | instantaneous |
| Overwrite delay time | list | deactivated |
| Delay time by ETS download or object Reset | list | overwriteable |
| Switch-off delay | list | not retriggerable |
| Follow-up time | time | 300 |
| Staircase timer | list | without manual off |
| Follow-up time | list | not retriggerable |
| Maximum additions | unsignedInt 2…5 | 3 |
| Number of prewarnings | unsignedInt 0…3 | 0 |
| Prewarning time
in seconds | unsignedInt 5…255 | 30 |
| Overwrite Follow-up time | list | deactivated |
| Follow-up time
by ETS download or object Reset | list | overwriteable |
| Switch-on time
in seconds | unsignedInt 1…60 | 1 |
| Switch-off time
in seconds | unsignedInt 1…60 | 1 |
| Logic operation 1 | list | deactivated |
| Logic operation 2 | list | deactivated |
| Locking | list | deactivated |
| Forced operation | list | deactivated |
| Safety | list | deactivated |
| Logic gate | list | OR |
| Object type | list | 1 bit (DPT 1 001) |
| at | list | less than or equal to |
| Value | float 0…1 | 0 |
| Value | float 0…100 | 40 |
| Value | float 0…255 | 0 |
| Value | float -128…127 | -50 |
| Value | float -671088.64…670433.28 | 400 |
| Value | float 0…65535 | 400 |
| Value | float -32768…32767 | 400 |
| Value | signedInt -2147483648…2147483647 | 400 |
| Value | float -9223372036854776000…9223372036854776000 | 400 |
| Value | unsignedInt 0…4294967295 | 400 |
| at | list | greater than or equal to |
| Value | float 0…1 | 1 |
| Value | float 0…100 | 60 |
| Value | float 0…255 | 50 |
| Value | float -128…127 | 50 |
| Value | float -671088.64…670433.28 | 500 |
| Value | float 0…65535 | 500 |
| Value | float -32768…32767 | 500 |
| Value | signedInt -2147483648…2147483647 | 500 |
| Value | float -9223372036854776000…9223372036854776000 | 500 |
| Value | unsignedInt 0…4294967295 | 500 |
| Logic input after bus voltage return | unsignedInt 0…1 | 0 |
| Action at start of lock | list | "1" |
| Value of basic function when unlocking (no priority active) | list | follows subordinate status |
| Locking function time-limited | list | deactivated |
| Locking time | time | 600 |
| On bus voltage return | list | deactivated |
| Value of basic function on removal of forced operation (no priority active) | list | follows subordinate status |
| On bus voltage return | list | not forced |
| At | list | less than or equal to |
| Action at
Start of safety function | list | "1" |
| Value of basic function when the safety function is deactivated (no priority active) | list | follows subordinate status |
| Cyclical monitoring | list | deactivated |
| Monitoring time in minutes | unsignedInt 1…255 | 10 |
| Contact delay | list | deactivated |
| Contact delay when switching on | time | 100 |
| Contact delay when switching off | time | 100 |
| Contact type | list | normally open contact (NO) |
| Feedback signals | list | deactivated |
| Feedback 1Bit | list | Active feedback object |
| Channel for collective feedback | list | activated |
| Feedback with open relay | list | "0" |
| Feedback for closed relays | list | "1" |