FutureKNX Universal Interface 8 Fold [FTR-UN8.1.1] FTR-UN8.1.1

AYPRO Technology · Order number FTR-UN8.1.1 · INTERFACE

Download .knxprod FTR-UN8.1.1 1.1 · 460 KB

Product

ManufacturerAYPRO Technology
Product nameFutureKNX Universal Interface 8 Fold [FTR-UN8.1.1]
Order numberFTR-UN8.1.1
HardwareFutureKNXUniversalInterface8fold
MediumTwisted Pair
Bus current (mA)10
Rail mountedNo
RegistrationRegistered · 2022-08-30
Languagesde-DE, en-US, tr-TR
Catalog entryM-0164_H-00000003-0_HP-0002-11-E158_CI-FTR.2DUN8.2E1.2E1-1
FingerprintE158
SHA-2569955750997f14e7fa9dc3c96d7e4060944910594b8cfaa1faf9d95e679d149c8
First seen2026-11-25
Markets69 markets

Application program: FTR-UN8.1.1 1.1

Application number$0002
Version1.1
Mask versionMV-0705 (7.5)
KNX Data SecureNo
Minimum ETS version5.0
Parameters1099
Group objects565
Group objects (565)
NoNameFunctionSizeDPTFlags
0Input 1Step Count Percentage1 Byte5.1 percentage (0..100%)CT
0Input 1Step Count Temperature °C2 Bytes9.1 temperature (°C)CT
0Input 1Step Count Temperature °F2 Bytes9.27 temperature (°F)CT
0Input 1Step Count Luminosity2 Bytes9.4 lux (Lux)CT
0Input 1Step Count 1 Byte1 Byte5.10 counter pulses (0..255)CT
0Input 1Step Count 2 Byte2 Bytes7.1 pulsesCT
0Input 1Step Count Scene1 Byte18.1 scene controlCT
0Input 1Switching1 Bit1.1 switchCT
0Input 1Up Down1 Bit1.8 up/downCT
0Input 1Value 1 Byte1 Byte5.10 counter pulses (0..255)CT
0Input 1Value Percentage1 Byte5.1 percentage (0..100%)CT
0Input 1Value Temperature2 Bytes9.1 temperature (°C)CT
0Input 1Value Luminosity2 Bytes9.4 lux (Lux)CT
0Input 1Value 2 Byte2 Bytes7.1 pulsesCT
0Input 1Scene1 Byte18.1 scene controlCT
0Input 1Toggle1 Bit1.1 switchCT
0Input 1Short Press Switching1 Bit1.1 switchCT
0Input 1Short Press Toggle1 Bit1.1 switchCT
0Input 1Short Press Percentage1 Byte5.1 percentage (0..100%)CT
0Input 1Short Press Temperature2 Bytes9.1 temperature (°C)CT
0Input 1Short Press Luminosity2 Bytes9.4 lux (Lux)CT
0Input 1Short Press 1 Byte1 Byte5.10 counter pulses (0..255)CT
0Input 1Short Press 2 Byte2 Bytes7.1 pulsesCT
1Input 1Dimming4 Bit3.7 dimming controlCT
1Input 1Stop Slat Angle1 Bit1.1 switchCT
1Input 1Long Press 1 Byte1 Byte5.10 counter pulses (0..255)CT
1Input 1Long Press Switching1 Bit1.1 switchCT
1Input 1Long Press Luminosity2 Bytes9.4 lux (Lux)CT
1Input 1Long Press Percentage1 Byte5.1 percentage (0..100%)CT
1Input 1Long Press Temperature2 Bytes9.1 temperature (°C)CT
1Input 1Long Press 2 Byte2 Bytes7.1 pulsesCT
1Input 1Long Press Toggle1 Bit1.1 switchCT
2Input 1Status1 Bit1.1 switchCR
2Input 1Short Press Status1 Bit1.11 stateCR
3Input 1Long Press Status1 Bit1.1 switchCR
4Input 1Locking1 Bit1.3 enableCWU
5Input 2Step Count Percentage1 Byte5.1 percentage (0..100%)CT
5Input 2Step Count Temperature °C2 Bytes9.1 temperature (°C)CT
5Input 2Step Count Temperature °F2 Bytes9.27 temperature (°F)CT
5Input 2Step Count Luminosity2 Bytes9.4 lux (Lux)CT
5Input 2Step Count 1 Byte1 Byte5.10 counter pulses (0..255)CT
5Input 2Step Count 2 Byte2 Bytes7.1 pulsesCT
5Input 2Step Count Scene1 Byte18.1 scene controlCT
5Input 2Switching1 Bit1.1 switchCT
5Input 2Up Down1 Bit1.8 up/downCT
5Input 2Value 1 Byte1 Byte5.10 counter pulses (0..255)CT
5Input 2Value Percentage1 Byte5.1 percentage (0..100%)CT
5Input 2Value Temperature2 Bytes9.1 temperature (°C)CT
5Input 2Value Luminosity2 Bytes9.4 lux (Lux)CT
5Input 2Value 2 Byte2 Bytes7.1 pulsesCT
5Input 2Scene1 Byte18.1 scene controlCT
5Input 2Toggle1 Bit1.1 switchCT
5Input 2Short Press Switching1 Bit1.1 switchCT
5Input 2Short Press Toggle1 Bit1.1 switchCT
5Input 2Short Press Percentage1 Byte5.1 percentage (0..100%)CT
5Input 2Short Press Temperature2 Bytes9.1 temperature (°C)CT
5Input 2Short Press Luminosity2 Bytes9.4 lux (Lux)CT
5Input 2Short Press 1 Byte1 Byte5.10 counter pulses (0..255)CT
5Input 2Short Press 2 Byte2 Bytes7.1 pulsesCT
6Input 2Long Press Switching1 Bit1.1 switchCT
6Input 2Dimming4 Bit3.7 dimming controlCT
6Input 2Stop Slat Angle1 Bit1.1 switchCT
6Input 2Long Press 1 Byte1 Byte5.10 counter pulses (0..255)CT
6Input 2Long Press Luminosity2 Bytes9.4 lux (Lux)CT
6Input 2Long Press Percentage1 Byte5.1 percentage (0..100%)CT
6Input 2Long Press Temperature2 Bytes9.1 temperature (°C)CT
6Input 2Long Press 2 Byte2 Bytes7.1 pulsesCT
6Input 2Long Press Toggle1 Bit1.1 switchCT
7Input 2Status1 Bit1.1 switchCR
7Input 2Short Press Status1 Bit1.11 stateCR
8Input 2Long Press Status1 Bit1.1 switchCR
9Input 2Locking1 Bit1.3 enableCWU
10Input 3Step Count Percentage1 Byte5.1 percentage (0..100%)CT
10Input 3Step Count Temperature °C2 Bytes9.1 temperature (°C)CT
10Input 3Step Count Temperature °F2 Bytes9.27 temperature (°F)CT
10Input 3Step Count Luminosity2 Bytes9.4 lux (Lux)CT
10Input 3Step Count 1 Byte1 Byte5.10 counter pulses (0..255)CT
10Input 3Step Count 2 Byte2 Bytes7.1 pulsesCT
10Input 3Step Count Scene1 Byte18.1 scene controlCT
10Input 3Switching1 Bit1.1 switchCT
10Input 3Up Down1 Bit1.8 up/downCT
10Input 3Value 1 Byte1 Byte5.10 counter pulses (0..255)CT
10Input 3Value Percentage1 Byte5.1 percentage (0..100%)CT
10Input 3Value Temperature2 Bytes9.1 temperature (°C)CT
10Input 3Value Luminosity2 Bytes9.4 lux (Lux)CT
10Input 3Value 2 Byte2 Bytes7.1 pulsesCT
10Input 3Scene1 Byte18.1 scene controlCT
10Input 3Toggle1 Bit1.1 switchCT
10Input 3Short Press Switching1 Bit1.1 switchCT
10Input 3Short Press Toggle1 Bit1.1 switchCT
10Input 3Short Press Percentage1 Byte5.1 percentage (0..100%)CT
10Input 3Short Press Temperature2 Bytes9.1 temperature (°C)CT
10Input 3Short Press Luminosity2 Bytes9.4 lux (Lux)CT
10Input 3Short Press 1 Byte1 Byte5.10 counter pulses (0..255)CT
10Input 3Short Press 2 Byte2 Bytes7.1 pulsesCT
11Input 3Long Press Switching1 Bit1.1 switchCT
11Input 3Dimming4 Bit3.7 dimming controlCT
11Input 3Stop Slat Angle1 Bit1.1 switchCT
11Input 3Long Press 1 Byte1 Byte5.10 counter pulses (0..255)CT
11Input 3Long Press Luminosity2 Bytes9.4 lux (Lux)CT
11Input 2Long Press Percentage1 Byte5.1 percentage (0..100%)CT
11Input 3Long Press Temperature2 Bytes9.1 temperature (°C)CT
11Input 3Long Press 2 Byte2 Bytes7.1 pulsesCT
11Input 3Long Press Toggle1 Bit1.1 switchCT
12Input 3Status1 Bit1.1 switchCR
12Input 3Short Press Status1 Bit1.11 stateCR
13Input 3Long Press Status1 Bit1.1 switchCR
14Input 3Locking1 Bit1.3 enableCWU
15Input 4Switching1 Bit1.1 switchCT
15Input 4Up Down1 Bit1.8 up/downCT
15Input 4Value 1 Byte1 Byte5.10 counter pulses (0..255)CT
15Input 4Value Percentage1 Byte5.1 percentage (0..100%)CT
15Input 4Value Temperature2 Bytes9.1 temperature (°C)CT
15Input 4Value Luminosity2 Bytes9.4 lux (Lux)CT
15Input 4Value 2 Byte2 Bytes7.1 pulsesCT
15Input 4Scene1 Byte18.1 scene controlCT
15Input 4Step Count 1 Byte1 Byte5.10 counter pulses (0..255)CT
15Input 4Step Count 2 Byte2 Bytes7.1 pulsesCT
15Input 4Step Count Luminosity2 Bytes9.4 lux (Lux)CT
15Input 4Step Count Percentage1 Byte5.1 percentage (0..100%)CT
15Input 4Step Count Scene1 Byte18.1 scene controlCT
15Input 4Step Count Temperature °C2 Bytes9.1 temperature (°C)CT
15Input 4Step Count Temperature °F2 Bytes9.27 temperature (°F)CT
15Input 4Toggle1 Bit1.1 switchCT
15Input 4Short Press Switching1 Bit1.1 switchCT
15Input 4Short Press Toggle1 Bit1.1 switchCT
15Input 4Short Press Percentage1 Byte5.1 percentage (0..100%)CT
15Input 4Short Press Temperature2 Bytes9.1 temperature (°C)CT
15Input 4Short Press 1 Byte1 Byte5.10 counter pulses (0..255)CT
15Input 4Short Press 2 Byte2 Bytes7.1 pulsesCT
15Input 4Short Press Luminosity2 Bytes9.4 lux (Lux)CT
16Input 4Long Press Switching1 Bit1.1 switchCT
16Input 4Dimming4 Bit3.7 dimming controlCT
16Input 4Stop Slat Angle1 Bit1.1 switchCT
16Input 4Long Press 1 Byte1 Byte5.10 counter pulses (0..255)CT
16Input 4Long Press Luminosity2 Bytes9.4 lux (Lux)CT
16Input 4Long Press Percentage1 Byte5.1 percentage (0..100%)CT
16Input 4Long Press Temperature2 Bytes9.1 temperature (°C)CT
16Input 4Long Press 2 Byte2 Bytes7.1 pulsesCT
16Input 4Long Press Toggle1 Bit1.1 switchCT
17Input 4Status1 Bit1.1 switchCR
17Input 4Short Press Status1 Bit1.11 stateCR
18Input 4Long Press Status1 Bit1.1 switchCR
19Input 4Locking1 Bit1.3 enableCWU
20Input 5Switching1 Bit1.1 switchCT
20Input 5Up Down1 Bit1.8 up/downCT
20Input 5Value 1 Byte1 Byte5.10 counter pulses (0..255)CT
20Input 5Value Percentage1 Byte5.1 percentage (0..100%)CT
20Input 5Value Temperature2 Bytes9.1 temperature (°C)CT
20Input 5Value Luminosity2 Bytes9.4 lux (Lux)CT
20Input 5Value 2 Byte2 Bytes7.1 pulsesCT
20Input 5Scene1 Byte18.1 scene controlCT
20OUT 5On Off1 Bit1.1 switchCT
20Input 5Step Count 1 Byte1 Byte5.10 counter pulses (0..255)CT
20Input 5Step Count 2 Byte2 Bytes7.1 pulsesCT
20Input 5Step Count Luminosity2 Bytes9.4 lux (Lux)CT
20Input 5Step Count Percentage1 Byte5.1 percentage (0..100%)CT
20Input 5Step Count Scene1 Byte18.1 scene controlCT
20Input 5Step Count Temperature °C2 Bytes9.1 temperature (°C)CT
20Input 5Step Count Temperature °F2 Bytes9.27 temperature (°F)CT
20Input 5Toggle1 Bit1.1 switchCT
20Input 5Short Press Switching1 Bit1.1 switchCT
20Input 5Short Press Toggle1 Bit1.1 switchCT
20Input 5Short Press Percentage1 Byte5.1 percentage (0..100%)CT
20Input 5Short Press Luminosity2 Bytes9.4 lux (Lux)CT
20Input 5Short Press 1 Byte1 Byte5.10 counter pulses (0..255)CT
20Input 5Short Press 2 Byte2 Bytes7.1 pulsesCT
20Input 5Short Press Temperature2 Bytes9.1 temperature (°C)CT
21Input 5Long Press Switching1 Bit1.1 switchCT
21Input 5Dimming4 Bit3.7 dimming controlCT
21Input 5Stop Slat Angle1 Bit1.1 switchCT
21Input 5Long Press 1 Byte1 Byte5.10 counter pulses (0..255)CT
21Input 5Long Press Luminosity2 Bytes9.4 lux (Lux)CT
21Input 5Long Press Percentage1 Byte5.1 percentage (0..100%)CT
21Input 5Long Press Temperature2 Bytes9.1 temperature (°C)CT
21Input 5Long Press 2 Byte2 Bytes7.1 pulsesCT
21OUT 5Blink1 Bit1.1 switchCT
21Input 5Long Press Toggle1 Bit1.1 switchCT
22Input 5Status1 Bit1.1 switchCR
22Input 5Short Press Status1 Bit1.11 stateCR
23Input 5Long Press Status1 Bit1.1 switchCR
24Input 5Locking1 Bit1.3 enableCWU
25Input 6Switching1 Bit1.1 switchCT
25Input 6Up Down1 Bit1.8 up/downCT
25Input 6Value 1 Byte1 Byte5.10 counter pulses (0..255)CT
25Input 6Value Percentage1 Byte5.1 percentage (0..100%)CT
25Input 6Value Temperature2 Bytes9.1 temperature (°C)CT
25Input 6Value Luminosity2 Bytes9.4 lux (Lux)CT
25Input 6Value 2 Byte2 Bytes7.1 pulsesCT
25Input 6Scene1 Byte18.1 scene controlCT
25OUT 6On Off1 Bit1.1 switchCT
25Input 6Step Count 1 Byte1 Byte5.10 counter pulses (0..255)CT
25Input 6Step Count 2 Byte2 Bytes7.1 pulsesCT
25Input 6Step Count Luminosity2 Bytes9.4 lux (Lux)CT
25Input 6Step Count Percentage1 Byte5.1 percentage (0..100%)CT
25Input 6Step Count Scene1 Byte18.1 scene controlCT
25Input 6Step Count Temperature °C2 Bytes9.1 temperature (°C)CT
25Input 6Step Count Temperature °F2 Bytes9.27 temperature (°F)CT
25Input 6Toggle1 Bit1.1 switchCT
25Input 6Short Press Switching1 Bit1.1 switchCT
25Input 6Short Press Toggle1 Bit1.1 switchCT
25Input 6Short Press Percentage1 Byte5.1 percentage (0..100%)CT
25Input 6Short Press Temperature2 Bytes9.1 temperature (°C)CT
25Input 6Short Press Luminosity2 Bytes9.4 lux (Lux)CT
25Input 6Short Press 1 Byte1 Byte5.10 counter pulses (0..255)CT
25Input 6Short Press 2 Byte2 Bytes7.1 pulsesCT
26Input 6Long Press Switching1 Bit1.1 switchCT
26Input 6Dimming4 Bit3.7 dimming controlCT
26Input 6Stop Slat Angle1 Bit1.1 switchCT
26Input 6Long Press 1 Byte1 Byte5.10 counter pulses (0..255)CT
26Input 6Long Press Luminosity2 Bytes9.4 lux (Lux)CT
26Input 6Long Press Percentage1 Byte5.1 percentage (0..100%)CT
26Input 6Long Press Temperature2 Bytes9.1 temperature (°C)CT
26Input 6Long Press 2 Byte2 Bytes7.1 pulsesCT
26OUT 6Blink1 Bit1.1 switchCT
26Input 6Long Press Toggle1 Bit1.1 switchCT
27Input 6Status1 Bit1.1 switchCR
27Input 6Short Press Status1 Bit1.11 stateCR
28Input 6Long Press Status1 Bit1.1 switchCR
29Input 6Locking1 Bit1.3 enableCWU
30Input 7Switching1 Bit1.1 switchCT
30Input 7Up Down1 Bit1.8 up/downCT
30Input 7Value 1 Byte1 Byte5.10 counter pulses (0..255)CT
30Input 7Value Percentage1 Byte5.1 percentage (0..100%)CT
30Input 7Value Temperature2 Bytes9.1 temperature (°C)CT
30Input 7Value Luminosity2 Bytes9.4 lux (Lux)CT
30Input 7Value 2 Byte2 Bytes7.1 pulsesCT
30Input 7Scene1 Byte18.1 scene controlCT
30OUT 7On Off1 Bit1.1 switchCT
30Input 7Step Count 1 Byte1 Byte5.10 counter pulses (0..255)CT
30Input 7Step Count 2 Byte2 Bytes7.1 pulsesCT
30Input 7Step Count Luminosity2 Bytes9.4 lux (Lux)CT
30Input 7Step Count Percentage1 Byte5.1 percentage (0..100%)CT
30Input 7Step Count Scene1 Byte18.1 scene controlCT
30Input 7Step Count Temperature °C2 Bytes9.1 temperature (°C)CT
30Input 7Step Count Temperature °F2 Bytes9.27 temperature (°F)CT
30Input 7Toggle1 Bit1.1 switchCT
30Input 7Short Press Switching1 Bit1.1 switchCT
30Input 7Short Press Toggle1 Bit1.1 switchCT
30Input 7Short Press Percentage1 Byte5.1 percentage (0..100%)CT
30Input 7Short Press Temperature2 Bytes9.1 temperature (°C)CT
30Input 7Short Press Luminosity2 Bytes9.4 lux (Lux)CT
30Input 7Short Press 1 Byte1 Byte5.10 counter pulses (0..255)CT
30Input 7Short Press 2 Byte2 Bytes7.1 pulsesCT
31Input 7Dimming4 Bit3.7 dimming controlCT
31Input 7Stop Slat Angle1 Bit1.1 switchCT
31Input 7Long Press 1 Byte1 Byte5.10 counter pulses (0..255)CT
31Input 7Long Press Switching1 Bit1.1 switchCT
31Input 7Long Press Luminosity2 Bytes9.4 lux (Lux)CT
31Input 7Long Press Percentage1 Byte5.1 percentage (0..100%)CT
31Input 7Long Press Temperature2 Bytes9.1 temperature (°C)CT
31Input 7Long Press 2 Byte2 Bytes7.1 pulsesCT
31OUT 7Blink1 Bit1.1 switchCT
31Input 7Long Press Toggle1 Bit1.1 switchCT
32Input 7Status1 Bit1.1 switchCR
32Input 7Short Press Status1 Bit1.11 stateCR
33Input 7Long Press Status1 Bit1.1 switchCR
34Input 7Locking1 Bit1.3 enableCWU
35Input 8Switching1 Bit1.1 switchCT
35Input 8Up Down1 Bit1.8 up/downCT
35Input 8Value 1 Byte1 Byte5.10 counter pulses (0..255)CT
35Input 8Value Percentage1 Byte5.1 percentage (0..100%)CT
35Input 8Value Temperature2 Bytes9.1 temperature (°C)CT
35Input 8Value Luminosity2 Bytes9.4 lux (Lux)CT
35Input 8Value 2 Byte2 Bytes7.1 pulsesCT
35Input 8Scene1 Byte18.1 scene controlCT
35OUT 8On Off1 Bit1.1 switchCT
35Input 8Step Count 1 Byte1 Byte5.10 counter pulses (0..255)CT
35Input 8Step Count 2 Byte2 Bytes7.1 pulsesCT
35Input 8Step Count Luminosity2 Bytes9.4 lux (Lux)CT
35Input 8Step Count Percentage1 Byte5.1 percentage (0..100%)CT
35Input 8Step Count Scene1 Byte18.1 scene controlCT
35Input 8Step Count Temperature °C2 Bytes9.1 temperature (°C)CT
35Input 8Step Count Temperature °F2 Bytes9.27 temperature (°F)CT
35Input 8Toggle1 Bit1.1 switchCT
35Input 8Short Press Switching1 Bit1.1 switchCT
35Input 8Short Press Toggle1 Bit1.1 switchCT
35Input 8Short Press Percentage1 Byte5.1 percentage (0..100%)CT
35Input 8Short Press Temperature2 Bytes9.1 temperature (°C)CT
35Input 8Short Press Luminosity2 Bytes9.4 lux (Lux)CT
35Input 8Short Press 1 Byte1 Byte5.10 counter pulses (0..255)CT
35Input 8Short Press 2 Byte2 Bytes7.1 pulsesCT
36Input 8Long Press Switching1 Bit1.1 switchCT
36Input 8Dimming4 Bit3.7 dimming controlCT
36Input 8Stop Slat Angle1 Bit1.1 switchCT
36Input 8Long Press Luminosity2 Bytes9.4 lux (Lux)CT
36Input 8Long Press Percentage1 Byte5.1 percentage (0..100%)CT
36Input 8Long Press Temperature2 Bytes9.1 temperature (°C)CT
36Input 8Long Press 1 Byte1 Byte5.10 counter pulses (0..255)CT
36Input 8Long Press 2 Byte2 Bytes7.1 pulsesCT
36OUT 8Blink1 Bit1.1 switchCT
36Input 8Long Press Toggle1 Bit1.1 switchCT
37Input 8Status1 Bit1.1 switchCR
37Input 8Short Press Status1 Bit1.11 stateCR
38Input 8Long Press Status1 Bit1.1 switchCR
39Input 8Locking1 Bit1.3 enableCWU
40RTC 1[AC] On Off Heating1 Bit1.1 switchCT
42RTC 1Threshold Low1 Bit1.2 booleanCRT
43RTC 1Threshold High1 Bit1.2 booleanCRT
44RTC 1Heating - Cooling Mode Change1 Bit1.100 cooling/heatingCT
44RTC 1HVAC Control Mode [1-Heat; 3-Cool]1 Byte20.105 HVAC control modeCT
45RTC 1Heating - Cooling Mode Status1 Bit1.100 cooling/heatingCRWU
45RTC 1HVAC Control Mode Status [1-Heat; 3-Cool]1 Byte20.105 HVAC control modeCRWU
46RTC 1Command Value For Heating Bit1 Bit1.1 switchCT
47RTC 1Command Value For Heating Byte1 Byte5.1 percentage (0..100%)CT
48RTC 1Command Value For Cooling Bit1 Bit1.1 switchCT
49RTC 1Command Value For Cooling Byte1 Byte5.1 percentage (0..100%)CT
50RTC 1Command Value For Heating-Cooling Bit1 Bit1.1 switchCT
51RTC 1Command Value For Heating-Cooling Byte1 Byte5.1 percentage (0..100%)CT
52RTC 1Control Of Additional Heating Byte1 Byte5.1 percentage (0..100%)CT
52RTC 1Control Of Additional Heating Bit1 Bit1.1 switchCT
53RTC 1Control Of Additional Cooling Byte1 Byte5.1 percentage (0..100%)CT
53RTC 1Control Of Additional Cooling Bit1 Bit1.1 switchCT
54RTC 1Fan Automatic - Manual1 Bit1.2 booleanCT
55RTC 1Fan Automatic - Manual Status1 Bit1.2 booleanCRWU
56RTC 1Control Fan Level 11 Bit1.3 enableCT
57RTC 1Control Fan Level 21 Bit1.3 enableCT
58RTC 1Control Fan Level 31 Bit1.3 enableCT
59RTC 1Status Fan Level 11 Bit1.11 stateCRWU
60RTC 1Status Fan Level 21 Bit1.11 stateCRWU
61RTC 1Status Fan Level 31 Bit1.11 stateCRWU
62RTC 1Fan Controller Stage1 Byte5.100 fan stage (0..255)CT
62RTC 1Fan Controller Percentage1 Byte5.1 percentage (0..100%)CT
63RTC 1Fan Controller Stage Status1 Byte5.100 fan stage (0..255)CRWU
63RTC 1Fan Controller Percentage Status1 Byte5.1 percentage (0..100%)CRWU
64RTC 1[RM] On Off1 Bit1.1 switchCWU
65RTC 1[RM] Status1 Bit1.11 stateCRT
66RTC 1[RM] Setpoint + / - Control1 Bit1.7 stepCWU
67RTC 1[RM] Actual Internal Temperature °C2 Bytes9.1 temperature (°C)CRT
67RTC 1[RM] Actual Internal Temperature °F2 Bytes9.27 temperature (°F)CRT
68RTC 1[RM] Actual Setpoint Temperature Control °C2 Bytes9.1 temperature (°C)CWU
68RTC 1[RM] Actual Setpoint Temperature Control °F2 Bytes9.27 temperature (°F)CWU
69RTC 1[RM] Actual Setpoint Temperature Status °C2 Bytes9.1 temperature (°C)CRT
69RTC 1[RM] Actual Setpoint Temperature Status °F2 Bytes9.27 temperature (°F)CRT
70RTC 1[RM] HVAC Mode Change1 Byte20.102 HVAC modeCWU
71RTC 1[RM] HVAC Mode Status1 Byte20.102 HVAC modeCRT
72RTC 1[RM] Reset Manual Setpoint Operation1 Bit1.15 resetCWU
73RTC 1[RM] Disable Additional Heating1 Bit1.3 enableCWU
74RTC 1[RM] Disable Additional Cooling1 Bit1.3 enableCWU
75RTC 1[RM] Fan Automatic Manual1 Bit1.2 booleanCWU
76RTC 1[RM] Fan Automatic Manual Status1 Bit1.2 booleanCRT
77RTC 1[RM] Heating - Cooling Mode Change1 Bit1.100 cooling/heatingCWU
77RTC 1[RM] HVAC Control Mode [1-Heat; 3-Cool]1 Byte20.105 HVAC control modeCWU
78RTC 1[RM] Heating - Cooling Mode Status1 Bit1.100 cooling/heatingCRT
78RTC 1[RM] HVAC Control Mode Status [1-Heat; 3-Cool]1 Byte20.105 HVAC control modeCRT
79RTC 1[RM] Fan Controller Stage1 Byte5.100 fan stage (0..255)CWU
79RTC 1[RM] Fan Controller Percentage1 Byte5.1 percentage (0..100%)CWU
80RTC 1[RM] Fan Controller Stage Status1 Byte5.100 fan stage (0..255)CRT
80RTC 1[RM] Fan Controller Percentage Status1 Byte5.1 percentage (0..100%)CRT
81RTC 1[AC] On Off Cooling1 Bit1.1 switchCT
83RTC 2[AC] On Off Heating1 Bit1.1 switchCT
85RTC 2Threshold Low1 Bit1.2 booleanCRT
86RTC 2Threshold High1 Bit1.2 booleanCRT
87RTC 2Heating - Cooling Mode Change1 Bit1.100 cooling/heatingCT
87RTC 2HVAC Control Mode [1-Heat; 3-Cool]1 Byte20.105 HVAC control modeCT
88RTC 2Heating - Cooling Mode Status1 Bit1.100 cooling/heatingCRWU
88RTC 2HVAC Control Mode Status [1-Heat; 3-Cool]1 Byte20.105 HVAC control modeCRWU
89RTC 2Command Value For Heating Bit1 Bit1.1 switchCT
90RTC 2Command Value For Heating Byte1 Byte5.1 percentage (0..100%)CT
91RTC 2Command Value For Cooling Bit1 Bit1.1 switchCT
92RTC 2Command Value For Cooling Byte1 Byte5.1 percentage (0..100%)CT
93RTC 2Command Value For Heating-Cooling Bit1 Bit1.1 switchCT
94RTC 2Command Value For Heating-Cooling Byte1 Byte5.1 percentage (0..100%)CT
95RTC 2Control Of Additional Heating Byte1 Byte5.1 percentage (0..100%)CT
95RTC 2Control Of Additional Heating Bit1 Bit1.1 switchCT
96RTC 2Control Of Additional Cooling Byte1 Byte5.1 percentage (0..100%)CT
96RTC 2Control Of Additional Cooling Bit1 Bit1.1 switchCT
97RTC 2Fan Automatic - Manual1 Bit1.2 booleanCT
98RTC 2Fan Automatic - Manual Status1 Bit1.2 booleanCRWU
99RTC 2Control Fan Level 11 Bit1.3 enableCT
100RTC 2Control Fan Level 21 Bit1.3 enableCT
101RTC 2Control Fan Level 31 Bit1.3 enableCT
102RTC 2Status Fan Level 11 Bit1.11 stateCRWU
103RTC 2Status Fan Level 21 Bit1.11 stateCRWU
104RTC 2Status Fan Level 31 Bit1.11 stateCRWU
105RTC 2Fan Controller Stage1 Byte5.100 fan stage (0..255)CT
105RTC 2Fan Controller Percentage1 Byte5.1 percentage (0..100%)CT
106RTC 2Fan Controller Stage Status1 Byte5.100 fan stage (0..255)CRWU
106RTC 2Fan Controller Percentage Status1 Byte5.1 percentage (0..100%)CRWU
107RTC 2[RM] On Off1 Bit1.1 switchCWU
108RTC 2[RM] Status1 Bit1.11 stateCRT
109RTC 2[RM] Setpoint + / - Control1 Bit1.7 stepCWU
110RTC 2[RM] Actual Internal Temperature °C2 Bytes9.1 temperature (°C)CRT
110RTC 2[RM] Actual Internal Temperature °F2 Bytes9.27 temperature (°F)CRT
111RTC 2[RM] Actual Setpoint Temperature Control °C2 Bytes9.1 temperature (°C)CWU
111RTC 2[RM] Actual Setpoint Temperature Control °F2 Bytes9.27 temperature (°F)CWU
112RTC 2[RM] Actual Setpoint Temperature Status °C2 Bytes9.1 temperature (°C)CRT
112RTC 2[RM] Actual Setpoint Temperature Status °F2 Bytes9.27 temperature (°F)CRT
113RTC 2[RM] HVAC Mode Change1 Byte20.102 HVAC modeCWU
114RTC 2[RM] HVAC Mode Status1 Byte20.102 HVAC modeCRT
115RTC 2[RM] Reset Manual Setpoint Operation1 Bit1.15 resetCWU
116RTC 2[RM] Disable Additional Heating1 Bit1.3 enableCWU
117RTC 2[RM] Disable Additional Cooling1 Bit1.3 enableCWU
118RTC 2[RM] Fan Automatic Manual1 Bit1.2 booleanCWU
119RTC 2[RM] Fan Automatic Manual Status1 Bit1.2 booleanCRT
120RTC 2[RM] Heating - Cooling Mode Change1 Bit1.100 cooling/heatingCWU
120RTC 2[RM] HVAC Control Mode [1-Heat; 3-Cool]1 Byte20.105 HVAC control modeCWU
121RTC 2[RM] Heating - Cooling Mode Status1 Bit1.100 cooling/heatingCRT
121RTC 2[RM] HVAC Control Mode Status 1-Heat; 3-Cool]1 Byte20.105 HVAC control modeCRT
122RTC 2[RM] Fan Controller Stage1 Byte5.100 fan stage (0..255)CWU
122RTC 2[RM] Fan Controller Percentage1 Byte5.1 percentage (0..100%)CWU
123RTC 2[RM] Fan Controller Stage Status1 Byte5.100 fan stage (0..255)CRT
123RTC 2[RM] Fan Controller Percentage Status1 Byte5.1 percentage (0..100%)CRT
124RTC 2[AC] On Off Cooling1 Bit1.1 switchCT
126RTC 3[AC] On Off Heating1 Bit1.1 switchCT
128RTC 3Threshold Low1 Bit1.2 booleanCRT
129RTC 3Threshold High1 Bit1.2 booleanCRT
130RTC 3Heating - Cooling Mode Change1 Bit1.100 cooling/heatingCT
130RTC 3HVAC Control Mode [1-Heat; 3-Cool]1 Byte20.105 HVAC control modeCT
131RTC 3Heating - Cooling Mode Status1 Bit1.100 cooling/heatingCRWU
131RTC 3HVAC Control Mode Status [1-Heat; 3-Cool]1 Byte20.105 HVAC control modeCRWU
132RTC 3Command Value For Heating Bit1 Bit1.1 switchCT
133RTC 3Command Value For Heating Byte1 Byte5.1 percentage (0..100%)CT
134RTC 3Command Value For Cooling Bit1 Bit1.1 switchCT
135RTC 3Command Value For Cooling Byte1 Byte5.1 percentage (0..100%)CT
136RTC 3Command Value For Heating-Cooling Bit1 Bit1.1 switchCT
137RTC 3Command Value For Heating-Cooling Byte1 Byte5.1 percentage (0..100%)CT
138RTC 3Control Of Additional Heating Byte1 Byte5.1 percentage (0..100%)CT
138RTC 3Control Of Additional Heating Bit1 Bit1.1 switchCT
139RTC 3Control Of Additional Cooling Byte1 Byte5.1 percentage (0..100%)CT
139RTC 3Control Of Additional Cooling Bit1 Bit1.1 switchCT
140RTC 3Fan Automatic - Manual1 Bit1.2 booleanCT
141RTC 3Fan Automatic - Manual Status1 Bit1.2 booleanCRWU
142RTC 3Control Fan Level 11 Bit1.3 enableCT
143RTC 3Control Fan Level 21 Bit1.3 enableCT
144RTC 3Control Fan Level 31 Bit1.3 enableCT
145RTC 3Status Fan Level 11 Bit1.11 stateCRWU
146RTC 3Status Fan Level 21 Bit1.11 stateCRWU
147RTC 3Status Fan Level 31 Bit1.11 stateCRWU
148RTC 3Fan Controller Stage1 Byte5.100 fan stage (0..255)CT
148RTC 3Fan Controller Percentage1 Byte5.1 percentage (0..100%)CT
149RTC 3Fan Controller Stage Status1 Byte5.100 fan stage (0..255)CRWU
149RTC 3Fan Controller Percentage Status1 Byte5.1 percentage (0..100%)CRWU
150RTC 3[RM] On Off1 Bit1.1 switchCWU
151RTC 3[RM] Status1 Bit1.11 stateCRT
152RTC 3[RM] Setpoint + / - Control1 Bit1.7 stepCWU
153RTC 3[RM] Actual Internal Temperature °C2 Bytes9.1 temperature (°C)CRT
153RTC 3[RM] Actual Internal Temperature °F2 Bytes9.27 temperature (°F)CRT
154RTC 3[RM] Actual Setpoint Temperature Control °C2 Bytes9.1 temperature (°C)CWU
154RTC 3[RM] Actual Setpoint Temperature Control °F2 Bytes9.27 temperature (°F)CWU
155RTC 3[RM] Actual Setpoint Temperature Status °C2 Bytes9.1 temperature (°C)CRT
155RTC 3[RM] Actual Setpoint Temperature Status °F2 Bytes9.27 temperature (°F)CRT
156RTC 3[RM] HVAC Mode Change1 Byte20.102 HVAC modeCWU
157RTC 3[RM] HVAC Mode Status1 Byte20.102 HVAC modeCRT
158RTC 3[RM] Reset Manual Setpoint Operation1 Bit1.15 resetCWU
159RTC 3[RM] Disable Additional Heating1 Bit1.3 enableCWU
160RTC 3[RM] Disable Additional Cooling1 Bit1.3 enableCWU
161RTC 3[RM] Fan Automatic Manual1 Bit1.2 booleanCWU
162RTC 3[RM] Fan Automatic Manual Status1 Bit1.2 booleanCRT
163RTC 3[RM] Heating - Cooling Mode Change1 Bit1.100 cooling/heatingCWU
163RTC 3[RM] HVAC Control Mode [1-Heat; 3-Cool]1 Byte20.105 HVAC control modeCWU
164RTC 3[RM] Heating - Cooling Mode Status1 Bit1.100 cooling/heatingCRT
164RTC 3[RM] HVAC Control Mode Status [1-Heat; 3-Cool]1 Byte20.105 HVAC control modeCRT
165RTC 3[RM] Fan Controller Stage1 Byte5.100 fan stage (0..255)CWU
165RTC 3[RM] Fan Controller Percentage1 Byte5.1 percentage (0..100%)CWU
166RTC 3[RM] Fan Controller Stage Status1 Byte5.100 fan stage (0..255)CRT
166RTC 3[RM] Fan Controller Percentage Status1 Byte5.1 percentage (0..100%)CRT
167RTC 3[AC] On Off Cooling1 Bit1.1 switchCT
169RTC 4[AC] On Off Heating1 Bit1.1 switchCT
171RTC 4Threshold Low1 Bit1.2 booleanCRT
172RTC 4Threshold High1 Bit1.2 booleanCRT
173RTC 4Heating - Cooling Mode Change1 Bit1.100 cooling/heatingCT
173RTC 4HVAC Control Mode [1-Heat; 3-Cool]1 Byte20.105 HVAC control modeCT
174RTC 4Heating - Cooling Mode Status1 Bit1.100 cooling/heatingCRWU
174RTC 4HVAC Control Mode Status [1-Heat; 3-Cool]1 Byte20.105 HVAC control modeCRWU
175RTC 4Command Value For Heating Bit1 Bit1.1 switchCT
176RTC 4Command Value For Heating Byte1 Byte5.1 percentage (0..100%)CT
177RTC 4Command Value For Cooling Bit1 Bit1.1 switchCT
178RTC 4Command Value For Cooling Byte1 Byte5.1 percentage (0..100%)CT
179RTC 4Command Value For Heating-Cooling Bit1 Bit1.1 switchCT
180RTC 4Command Value For Heating-Cooling Byte1 Byte5.1 percentage (0..100%)CT
181RTC 4Control Of Additional Heating Byte1 Byte5.1 percentage (0..100%)CT
181RTC 4Control Of Additional Heating Bit1 Bit1.1 switchCT
182RTC 4Control Of Additional Cooling Byte1 Byte5.1 percentage (0..100%)CT
182RTC 4Control Of Additional Cooling Bit1 Bit1.1 switchCT
183RTC 4Fan Automatic - Manual1 Bit1.2 booleanCT
184RTC 4Fan Automatic - Manual Status1 Bit1.2 booleanCRWU
185RTC 4Control Fan Level 11 Bit1.3 enableCT
186RTC 4Control Fan Level 21 Bit1.3 enableCT
187RTC 4Control Fan Level 31 Bit1.3 enableCT
188RTC 4Status Fan Level 11 Bit1.11 stateCRWU
189RTC 4Status Fan Level 21 Bit1.11 stateCRWU
190RTC 4Status Fan Level 31 Bit1.11 stateCRWU
191RTC 4Fan Controller Stage1 Byte5.100 fan stage (0..255)CT
191RTC 4Fan Controller Percentage1 Byte5.1 percentage (0..100%)CT
192RTC 4Fan Controller Stage Status1 Byte5.100 fan stage (0..255)CRWU
192RTC 4Fan Controller Percentage Status1 Byte5.1 percentage (0..100%)CRWU
193RTC 4[RM] On Off1 Bit1.1 switchCWU
194RTC 4[RM] Status1 Bit1.11 stateCRT
195RTC 4[RM] Setpoint + / - Control1 Bit1.7 stepCWU
196RTC 4[RM] Actual Internal Temperature °C2 Bytes9.1 temperature (°C)CRT
196RTC 4[RM] Actual Internal Temperature °F2 Bytes9.27 temperature (°F)CRT
197RTC 4[RM] Actual Setpoint Temperature Control °C2 Bytes9.1 temperature (°C)CWU
197RTC 4[RM] Actual Setpoint Temperature Control °F2 Bytes9.27 temperature (°F)CWU
198RTC 4[RM] Actual Setpoint Temperature Status °C2 Bytes9.1 temperature (°C)CRT
198RTC 4[RM] Actual Setpoint Temperature Status °F2 Bytes9.27 temperature (°F)CRT
199RTC 4[RM] HVAC Mode Change1 Byte20.102 HVAC modeCWU
200RTC 4[RM] HVAC Mode Status1 Byte20.102 HVAC modeCRT
201RTC 4[RM] Reset Manual Setpoint Operation1 Bit1.15 resetCWU
202RTC 4[RM] Disable Additional Heating1 Bit1.3 enableCWU
203RTC 4[RM] Disable Additional Cooling1 Bit1.3 enableCWU
204RTC 4[RM] Fan Automatic Manual1 Bit1.2 booleanCWU
205RTC 4[RM] Fan Automatic Manual Status1 Bit1.2 booleanCRT
206RTC 4[RM] Heating - Cooling Mode Change1 Bit1.100 cooling/heatingCWU
206RTC 4[RM] HVAC Control Mode [1-Heat; 3-Cool]1 Byte20.105 HVAC control modeCWU
207RTC 4[RM] Heating - Cooling Mode Status1 Bit1.100 cooling/heatingCRT
207RTC 4[RM] HVAC Control Mode Status [1-Heat; 3-Cool]1 Byte20.105 HVAC control modeCRT
208RTC 4[RM] Fan Controller Stage1 Byte5.100 fan stage (0..255)CWU
208RTC 4[RM] Fan Controller Percentage1 Byte5.1 percentage (0..100%)CWU
209RTC 4[RM] Fan Controller Stage Status1 Byte5.100 fan stage (0..255)CRT
209RTC 4[RM] Fan Controller Percentage Status1 Byte5.1 percentage (0..100%)CRT
210RTC 4[AC] On Off Cooling1 Bit1.1 switchCT
212Converter 1Input 1 Bit1 Bit1.1 switchCWU
212Converter 1Input 2 Bit2 Bit2.1 switch controlCWU
212Converter 1Input 1 Byte1 Byte5.10 counter pulses (0..255)CWU
212Converter 1Input 2 Byte2 Bytes7.1 pulsesCWU
213Converter 1Output 1 Bit1 Bit1.1 switchCRT
213Converter 1Output 2 Bit2 Bit2.1 switch controlCRT
213Converter 1Output 1 Byte1 Byte5.10 counter pulses (0..255)CRT
213Converter 1Output 2 Byte2 Bytes7.1 pulsesCRT
214Converter 2Input 1 Bit1 Bit1.1 switchCWU
214Converter 2Input 2 Bit2 Bit2.1 switch controlCWU
214Converter 2Input 1 Byte1 Byte5.10 counter pulses (0..255)CWU
214Converter 2Input 2 Byte2 Bytes7.1 pulsesCWU
215Converter 2Output 1 Bit1 Bit1.1 switchCRT
215Converter 2Output 2 Bit2 Bit2.1 switch controlCRT
215Converter 2Output 1 Byte1 Byte5.10 counter pulses (0..255)CRT
215Converter 2Output 2 Byte2 Bytes7.1 pulsesCRT
216Converter 3Input 1 Bit1 Bit1.1 switchCWU
216Converter 3Input 2 Bit2 Bit2.1 switch controlCWU
216Converter 3Input 1 Byte1 Byte5.10 counter pulses (0..255)CWU
216Converter 3Input 2 Byte2 Bytes7.1 pulsesCWU
217Converter 3Output 1 Bit1 Bit1.1 switchCRT
217Converter 3Output 2 Bit2 Bit2.1 switch controlCRT
217Converter 3Output 1 Byte1 Byte5.10 counter pulses (0..255)CRT
217Converter 3Output 2 Byte2 Bytes7.1 pulsesCRT
218Converter 4Input 1 Bit1 Bit1.1 switchCWU
218Converter 4Input 2 Bit2 Bit2.1 switch controlCWU
218Converter 4Input 1 Byte1 Byte5.10 counter pulses (0..255)CWU
218Converter 4Input 2 Byte2 Bytes7.1 pulsesCWU
219Converter 4Output 1 Bit1 Bit1.1 switchCRT
219Converter 4Output 2 Bit2 Bit2.1 switch controlCRT
219Converter 4Output 1 Byte1 Byte5.10 counter pulses (0..255)CRT
219Converter 4Output 2 Byte2 Bytes7.1 pulsesCRT
224Logic Gate 1Input 11 Bit1.2 booleanCWU
225Logic Gate 1Input 21 Bit1.2 booleanCWU
226Logic Gate 1Input 31 Bit1.2 booleanCWU
227Logic Gate 1Input 41 Bit1.2 booleanCWU
228Logic Gate 1Output 11 Bit1.2 booleanCRT
229Logic Gate 2Input 11 Bit1.2 booleanCWU
230Logic Gate 2Input 21 Bit1.2 booleanCWU
231Logic Gate 2Input 31 Bit1.2 booleanCWU
232Logic Gate 2Input 41 Bit1.2 booleanCWU
233Logic Gate 2Output 21 Bit1.2 booleanCRT
234Logic Gate 3Input 11 Bit1.2 booleanCWU
235Logic Gate 3Input 21 Bit1.2 booleanCWU
236Logic Gate 3Input 31 Bit1.2 booleanCWU
237Logic Gate 3Input 41 Bit1.2 booleanCWU
238Logic Gate 3Output 31 Bit1.2 booleanCRT
239Logic Gate 4Input 11 Bit1.2 booleanCWU
240Logic Gate 4Input 21 Bit1.2 booleanCWU
241Logic Gate 4Input 31 Bit1.2 booleanCWU
242Logic Gate 4Input 41 Bit1.2 booleanCWU
243Logic Gate 4Output 41 Bit1.2 booleanCRT
254FTR-UN8.1.1Device Notification1 Bit1.2 booleanCT
Parameters (212)
ParameterTypeDefault
HVAC Control Mode SelectionlistDPT 1.100 [Bit]
Receive Status FromlistStatus From Controlled Device
Operation Heating Cooling Mode After ResetlistHeating
Fan Has Auto ModeunsignedInt 0…10
Fan Control TypelistScaling [DPT 5.001: %]
Command Value Data TypelistSwitching (1 Bit)
Temperature UnitlistCelcius
Weighting Factor (Internal + External)list100 % / 0 %
Temperature Sensor SelectlistInternal
Temperature ThresholdlistDisable
Min ± Value Of Temperature To Send To BUSlistDisabled
Internal Sensor CalibrationsignedInt -50…500
External Sensor CalibrationsignedInt -50…500
Lower Limitlist5 °C
Lower Limitlist41.0 °F
Higher Limitlist30 °C
Higher Limitlist86.0 °F
Sending Interval For TemperatureunsignedInt 1…255180
Room Controller FunctionlistHeating
Command Value Objectlist1 Common Object
Heating Cooling ChangeoverlistAutomatic
Operation Mode After ResetlistAuto
Type Of Heating SystemlistWarm Water Heating
Type Of Cooling SystemlistCool Ceiling
Heating Control Typelist2 - Points
Cooling Control Typelist2 - Points
Heating Hysteresislist0.2 °C
Cooling Hysteresislist0.2 °C
Heating Sending Of Command Value PeriodunsignedInt 0…2550
Cooling Sending Of Command Value PeriodunsignedInt 0…2550
Heating Minimum Control Valuelist0 %
Heating Maximum Control Valuelist70 %
Cooling Minimum Control Valuelist0 %
Cooling Maximum Control Valuelist70 %
Heating Minimum Oscillation Value SendunsignedInt 1…1001
Cooling Minimum Oscillation Value SendunsignedInt 1…1001
Additional Heating SystemunsignedInt 0…10
Additional Cooling SystemunsignedInt 0…10
Heating Control Data TypelistSwitching (1 Bit)
Cooling Control Data TypelistSwitching (1 Bit)
Heating Offset From Setpoint Activelist1.0 °C
Cooling Offset From Setpoint Activelist1.0 °C
Heating Additional Hysteresislist0.2 °C
Cooling Additional Hysteresislist0.2 °C
Heating Sending Of Control Value PeriodicallyunsignedInt 0…2550
Cooling Sending Of Control Value PeriodicallyunsignedInt 0…2550
Disable Additional HeatingunsignedInt 0…10
Disable Additional CoolingunsignedInt 0…10
Sending Of SetpointlistOn Change
Period Of SendingunsignedInt 1…1001
Maximum Manual Setpoint Adjustment Allowedlist± 1.0 °C
End Of Manual OperationlistReset Manual Operation Object
Behaviour After Receiving New Mode SetpointlistReset Manual Operation
Setpoint Temperature After Power FailurelistNo Reaction
Heating Setpoint Comfort Modelist10.0 °C
Heating Setpoint Standby Modelist10.0 °C
Heating Setpoint Night Modelist10.0 °C
Heating Setpoint Frost Protectionlist0.0 °C
Cooling Setpoint Comfort Modelist10.0 °C
Cooling Setpoint Standby Modelist10.0 °C
Cooling Setpoint Night Modelist27.0 °C
Cooling Setpoint Heat Protectionlist25.0 °C
Minimum Dead Bandlist1.0 °C
Number Of Fan LevellistDisable
Fan Control ConnectlistHeating
Fan Level Control Individual ObjectunsignedInt 0…10
Fan Level Control Object ByteunsignedInt 0…10
Manual / Automatic Control Objectlist0: Manual / 1: Auto
Fan Level 1 Lower LimitunsignedInt 1…1001
Fan Level 2 Lower LimitunsignedInt 1…1001
Fan Level 3 Lower LimitunsignedInt 1…1001
Feedback Fan Level Individual ObjectunsignedInt 0…10
Feedback Fan Level Control ObjectunsignedInt 0…10
Feedback Manual / Automatic Objectlist0: Manual / 1: Auto
Fan Level After ResetlistOff
Pwm Cycle TimeunsignedInt 1…1001
Maximum Manual Setpoint Adjustment Allowedlist± 1.0 °F
Heating Hysteresislist0.4 °F
Cooling Hsyteresislist0.4 °F
Minimum Dead Bandlist1.0 °F
Heating Setpoint Comfort Modelist50.0 °F
Heating Setpoint Standby Modelist50.0 °F
Heating Setpoint Night Modelist50.0 °F
Cooling Setpoint Comfort Modelist50.0 °F
Cooling Setpoint Standby Modelist50.0 °F
Cooling Setpoint Night Modelist50.0 °F
Heating Offset From Setpoint Activelist1.0 °F
Cooling Offset From Setpoint Activelist1.0 °F
Heating Setpoint Frost Protectionlist32.0 °F
Cooling Setpoint Heat Protectionlist77.0 °F
AC ControlunsignedInt 0…10
Heating Additional Hysteresislist1.2 °F
Cooling Additional Hysteresislist1.2 °F
Send Temperature Value PeriodicallyunsignedInt 0…10
Step Count 1unsignedInt 0…1000
Step Count 1unsignedInt 0…500
Step Count 1unsignedInt 32…12232
Step Count 1unsignedInt 0…100000
Step Count 1unsignedInt 0…2550
Step Count 1unsignedInt 0…655350
Step Count 1unsignedInt 1…641
Step Count 2unsignedInt 0…1000
Step Count 2unsignedInt 0…500
Step Count 2unsignedInt 32…12232
Step Count 2unsignedInt 0…100000
Step Count 2unsignedInt 0…2550
Step Count 2unsignedInt 0…655350
Step Count 2unsignedInt 1…641
Step Count 3unsignedInt 0…1000
Step Count 3unsignedInt 0…500
Step Count 3unsignedInt 32…12232
Step Count 3unsignedInt 0…100000
Step Count 3unsignedInt 0…2550
Step Count 3unsignedInt 0…655350
Step Count 3unsignedInt 1…641
Step Count 4unsignedInt 0…1000
Step Count 4unsignedInt 0…500
Step Count 4unsignedInt 32…12232
Step Count 4unsignedInt 0…100000
Step Count 4unsignedInt 0…2550
Step Count 4unsignedInt 0…655350
Step Count 4unsignedInt 1…641
Step Count 5unsignedInt 0…1000
Step Count 5unsignedInt 0…500
Step Count 5unsignedInt 32…12232
Step Count 5unsignedInt 0…100000
Step Count 5unsignedInt 0…2550
Step Count 5unsignedInt 0…655350
Step Count 5unsignedInt 1…641
SelectionlistPercentage
Step Count BehaviorlistCycle Mode
Step NumberunsignedInt 1…51
Temperature UnitlistCelcius [°C]
Module Alive NotificationunsignedInt 0…10
Module Alive PeriodlistDisable
Channel 1listDisabled
Channel 2listDisabled
Channel 3listDisabled
Channel 4listDisabled
Channel 5listDisabled
Channel 6listDisabled
On Press / On ReleaselistOn / -
Storage FunctionunsignedInt 0…10
Periodical SendingunsignedInt 0…10
LockinglistDisabled
Sending DelayunsignedInt 0…2550
Periodical Sending IntervalunsignedInt 1…2551
On Press / On ReleaselistToggle / -
Dimming SelectionlistDimming With 1 Button
DirectionlistUp
Long Press Durationlist0.4 sec
SelectionlistShutter / Blinds With 1 Button
ValueunsignedInt 0…1000
ValueunsignedInt 0…500
ValueunsignedInt 0…100000
ValueunsignedInt 0…2550
ValueunsignedInt 0…655350
On Press / On ReleaselistSend / -
On Short PresslistDisable
On Long PresslistDisable
Channel 7listDisabled
Channel 8listDisabled
Convert FunctionunsignedInt 0…10
Convert 1unsignedInt 0…10
Logic Gate 1listDisable
Logic Gate FunctionunsignedInt 0…10
Convert 2unsignedInt 0…10
Convert 3unsignedInt 0…10
Convert 4unsignedInt 0…10
Logic Gate 2listDisable
Logic Gate 3listDisable
Logic Gate 4listDisable
Send StatuslistEach Input Event
Number of Inputslist1 Input
Output BehaviourlistNormal
Switch On DelayunsignedInt 0…2550
Switch Off DelayunsignedInt 0…2550
Cyclical Sending of StatuslistDisable
Convert Input Typelist1 Bit
Convert Output Typelist1 Bit
Convert Input ValueunsignedInt 0…655350
Convert Output ValueunsignedInt 0…655350
Convert Input ValueunsignedInt 0…2550
Convert Input ValueunsignedInt 0…30
Convert Input ValueunsignedInt 0…10
Convert Output ValueunsignedInt 0…2550
Convert Output ValueunsignedInt 0…30
Convert Output ValueunsignedInt 0…10
Scene NumberunsignedInt 1…641
Proportional Band (K)text4.0 K
Integral Timetext90
Proportional Band (K)text5.0 K
Integral Timetext240
Integral Timetext150
Integral Timetext100
Long Pres DurationunsignedInt 5…1005
Switch On Polaritylist1: On
On DelayunsignedInt 0…10
Out FunctionlistOn / Off
Delay TimeunsignedInt 0…2550
Out Blink On DelayunsignedInt 0…2550
Out Blink Off DelayunsignedInt 0…2550
Status ObjectunsignedInt 0…10
Led Bus Voltage RecoverylistOn
Short PresslistStop / Step
pidChecklist
Fahrenheitfloat -1800…18500
Degree Celciusfloat -1800…18500
Heating Setpoint Auto Modelist10.0 °C
Cooling Setpoint Auto Modelist10.0 °C
Heating Setpoint Auto Modelist21.0 °C
Cooling Setpoint Auto Modelist24.0 °C

Version history

ApplicationApp noFingerprintFirst seenSizeFile
FTR-UN8.1.1 1.1 latest$0002E1582026-11-25460 KBDownload

About this file

This is the official ETS product database for the AYPRO Technology FutureKNX Universal Interface 8 Fold [FTR-UN8.1.1] (FTR-UN8.1.1), published by the manufacturer in the KNX online catalog. To use it, open ETS, go to Catalogs → Import and choose the downloaded .knxprod file. The device then appears in your catalog and can be added to a project. Older versions are kept so existing projects can be matched to the application program they were commissioned with.