Ave S.p.A.  444KNXT2OT 444KNXT2OT Toggle push-buttons 1 mod. S44

444KNXT2OT Toggle push-buttons 1 mod. S44 444KNXT2OT

Ave S.p.A. · Order number 444KNXT2OT · Command devices

444KNXT2OT Toggle push-buttons 1 mod. S44

Download .knxprod Ave. Toggle push-buttons 2 ch 1 mod. S44 0.1 · 214 KB

Product

ManufacturerAve S.p.A.
Product name444KNXT2OT Toggle push-buttons 1 mod. S44
Order number444KNXT2OT
Hardware444KNXT2xx
MediumTwisted Pair
Bus current (mA)8.5
Rail mountedNo
RegistrationRegistered · 2020-10-08
Languagesde-DE, fr-FR, it-IT, en-US
Catalog entryM-01A7_H-0x01A720800000-1_HP-0004-01-5D1B_CI-444KNXT2OT-1
Fingerprint5D1B
SHA-256372a7300ec50526e2bac075d0167fb68b7d06d8d1d9b70b2f753f6c12032df48
First seen2026-11-25
Markets59 markets

Application program: Ave. Toggle push-buttons 2 ch 1 mod. S44 0.1

Application number$0004
Version0.1
Mask versionMV-07B0 (System B)
KNX Data SecureNo
Minimum ETS version4.0
Parameters178
Group objects118
Group objects (118)
NoNameFunctionSizeDPTFlags
1Device lockActivate1 Bit1.3 enableCWU
2Device lockActivate status1 Bit1.11 stateCRT
3LED modeSet day/night1 Bit1.3 enableCWU
4LED modeDay/night status1 Bit1.11 stateCRT
5LED brightnessSet standard/reduced1 Bit1.3 enableCWU
6LED brightnessStandard/reduced status1 Bit1.11 stateCRT
7LEDEnable1 Bit1.3 enableCWU
8LEDEnable status1 Bit1.11 stateCRT
9LEDSet ON/OFF1 Bit1.1 switchCWU
10LEDON/OFF status1 Bit1.11 stateCRT
11LEDSet alarm 11 Bit1.1 switchCWU
12LEDAlarm 1 status1 Bit1.11 stateCRT
13LEDSet alarm 21 Bit1.1 switchCWU
14LEDAlarm 2 status1 Bit1.11 stateCRT
15Position 1Enable function lock1 Bit1.3 enableCWU
16Position 1Function lock enable status1 Bit1.11 stateCRT
17Position 1Switching1 Bit1.1 switchCWTU
18Position 1Switching (long press)1 Bit1.1 switchCWTU
19Position 1Scene (long press)1 Byte17.1 scene numberCT
20Position 1Update for switching1 Bit1.1 switchCWU
21Position 1Update for switching (long press)1 Bit1.1 switchCWU
22Position 1Switching1 Bit1.1 switchCWTU
23Position 1Dimming4 Bit3.7 dimming controlCT
24Position 1Update for switching1 Bit1.3 enableCWU
25Position 1Scene1 Byte18.1 scene controlCT
26Position 1Shutter stop1 Bit1.7 stepCT
27Position 1Shutter move1 Bit1.8 up/downCT
28Position 1Cyclic values sending1 Byte5.10 counter pulses (0..255)CT
29Position 1Cyclic values sending (long press)1 Byte5.10 counter pulses (0..255)CT
30Position 1Forcing2 Bit2.1 switch controlCWTU
31Position 1Action 1 - Switching1 Bit1.1 switchCT
31Position 1Action 1 - Shutter move1 Bit1.8 up/downCT
31Position 1Action 1 - Scene1 Byte17.1 scene numberCT
31Position 1Action 1 - Value sending (0-255)1 Byte5.10 counter pulses (0..255)CT
31Position 1Action 1 - Value sending (%)1 Byte5.1 percentage (0..100%)CT
31Position 1Action 1 - Clima1 Byte20.102 HVAC modeCT
32Position 1Action 2 - Switching1 Bit1.1 switchCT
32Position 1Action 2 - Shutter move1 Bit1.8 up/downCT
32Position 1Action 2 - Scene1 Byte17.1 scene numberCT
32Position 1Action 2 - Value sending (0-255)1 Byte5.10 counter pulses (0..255)CT
32Position 1Action 2 - Value sending (%)1 Byte5.1 percentage (0..100%)CT
32Position 1Action 2 - Clima1 Byte20.102 HVAC modeCT
33Position 1Action 3 - Switching1 Bit1.1 switchCT
33Position 1Action 3 - Shutter move1 Bit1.8 up/downCT
33Position 1Action 3 - Scene1 Byte17.1 scene numberCT
33Position 1Action 3 - Value sending (0-255)1 Byte5.10 counter pulses (0..255)CT
33Position 1Action 3 - Value sending (%)1 Byte5.1 percentage (0..100%)CT
33Position 1Action 3 - Clima1 Byte20.102 HVAC modeCT
34Position 1Action 1 (long press) - Switching1 Bit1.1 switchCT
34Position 1Action 1 (long press) - Shutter move1 Bit1.8 up/downCT
34Position 1Action 1 (long press) - Scene1 Byte17.1 scene numberCT
34Position 1Action 1 (long press) - Value sending (0-255)1 Byte5.10 counter pulses (0..255)CT
34Position 1Action 1 (long press) - Value sending (%)1 Byte5.1 percentage (0..100%)CT
34Position 1Action 1 (long press) - Clima1 Byte20.102 HVAC modeCT
35Position 1Action 2 (long press) - Switching1 Bit1.1 switchCT
35Position 1Action 2 (long press) - Shutter move1 Bit1.8 up/downCT
35Position 1Action 2 (long press) - Scene1 Byte17.1 scene numberCT
35Position 1Action 2 (long press) - Value sending (0-255)1 Byte5.10 counter pulses (0..255)CT
35Position 1Action 2 (long press) - Value sending (%)1 Byte5.1 percentage (0..100%)CT
35Position 1Action 2 (long press) - Clima1 Byte20.102 HVAC modeCT
36Position 1Action 3 (long press) - Switching1 Bit1.1 switchCT
36Position 1Action 3 (long press) - Shutter move1 Bit1.8 up/downCT
36Position 1Action 3 (long press) - Scene1 Byte17.1 scene numberCT
36Position 1Action 3 (long press) - Value sending (0-255)1 Byte5.10 counter pulses (0..255)CT
36Position 1Action 3 (long press) - Value sending (%)1 Byte5.1 percentage (0..100%)CT
36Position 1Action 3 (long press) - Scene1 Byte20.102 HVAC modeCT
37Position 2Enable function lock1 Bit1.3 enableCWU
38Position 2Function lock enable status1 Bit1.11 stateCRT
39Position 2Switching1 Bit1.1 switchCWTU
40Position 2Switching (long press)1 Bit1.1 switchCWTU
41Position 2Scene (long press)1 Byte17.1 scene numberCT
42Position 2Update for switching1 Bit1.1 switchCWU
43Position 2Update for switching (long press)1 Bit1.1 switchCWU
44Position 2Switching1 Bit1.1 switchCWTU
45Position 2Dimming4 Bit3.7 dimming controlCT
46Position 2Update for switching1 Bit1.3 enableCWU
47Position 2Scene1 Byte18.1 scene controlCT
48Position 2Shutter stop1 Bit1.7 stepCT
49Position 2Shutter move1 Bit1.8 up/downCT
50Position 2Cyclic values sending1 Byte5.10 counter pulses (0..255)CT
51Position 2Cyclic values sending (long press)1 Byte5.10 counter pulses (0..255)CT
52Position 2Forcing2 Bit2.1 switch controlCWTU
53Position 2Action 1 - Switching1 Bit1.1 switchCT
53Position 2Action 1 - Shutter move1 Bit1.8 up/downCT
53Position 2Action 1 - Scene1 Byte17.1 scene numberCT
53Position 2Action 1 - Value sending (0-255)1 Byte5.10 counter pulses (0..255)CT
53Position 2Action 1 - Value sending (%)1 Byte5.1 percentage (0..100%)CT
53Position 2Action 1 - Clima1 Byte20.102 HVAC modeCT
54Position 2Action 2 - Switching1 Bit1.1 switchCT
54Position 2Action 2 - Shutter move1 Bit1.8 up/downCT
54Position 2Action 2 - Scene1 Byte17.1 scene numberCT
54Position 2Action 2 - Value sending (0-255)1 Byte5.10 counter pulses (0..255)CT
54Position 2Action 2 - Value sending (%)1 Byte5.1 percentage (0..100%)CT
54Position 2Action 2 - Clima1 Byte20.102 HVAC modeCT
55Position 2Action 3 - Switching1 Bit1.1 switchCT
55Position 2Action 3 - Shutter move1 Bit1.8 up/downCT
55Position 2Action 3 - Scene1 Byte17.1 scene numberCT
55Position 2Action 3 - Value sending (0-255)1 Byte5.10 counter pulses (0..255)CT
55Position 2Action 3 - Value sending (%)1 Byte5.1 percentage (0..100%)CT
55Position 2Action 3 - Clima1 Byte20.102 HVAC modeCT
56Position 2Action 1 (long press) - Switching1 Bit1.1 switchCT
56Position 2Action 1 (long press) - Shutter move1 Bit1.8 up/downCT
56Position 2Action 1 (long press) - Scene1 Byte17.1 scene numberCT
56Position 2Action 1 (long press) - Value sending (0-255)1 Byte5.10 counter pulses (0..255)CT
56Position 2Action 1 (long press) - Value sending (%)1 Byte5.1 percentage (0..100%)CT
56Position 2Action 1 (long press) - Clima1 Byte20.102 HVAC modeCT
57Position 2Action 2 (long press) - Switching1 Bit1.1 switchCT
57Position 2Action 2 (long press) - Shutter move1 Bit1.8 up/downCT
57Position 2Action 2 (long press) - Scene1 Byte17.1 scene numberCT
57Position 2Action 2 (long press) - Value sending (0-255)1 Byte5.10 counter pulses (0..255)CT
57Position 2Action 2 (long press) - Value sending (%)1 Byte5.1 percentage (0..100%)CT
57Position 2Action 2 (long press) - Clima1 Byte20.102 HVAC modeCT
58Position 2Action 3 (long press) - Switching1 Bit1.1 switchCT
58Position 2Action 3 (long press) - Shutter move1 Bit1.8 up/downCT
58Position 2Action 3 (long press) - Scene1 Byte17.1 scene numberCT
58Position 2Action 3 (long press) - Value sending (0-255)1 Byte5.10 counter pulses (0..255)CT
58Position 2Action 3 (long press) - Value sending (%)1 Byte5.1 percentage (0..100%)CT
58Position 2Action 3 (long press) - Clima1 Byte20.102 HVAC modeCT
Parameters (56)
ParameterTypeDefault
Function position 1listSwitch
Lock message valuelistMessage 1
Function locklistDisable
Long press modelistNone
Release mode after long presslistDisable
Long press timelist10 s
Long press timelist1.5 s
Press and release modelistDisable
Long press modelistIncrease/decrease
Long press modelistNo forcing, ON
Short press modelistStop
Short press modelistNo forcing, OFF
Short press modelistON/OFF
Long press modelistUp/down
Status group objectslistDisable
Status group objects (long press)listDisable
Value 2unsignedInt 0…2552
Value 3unsignedInt 0…2553
Value 4unsignedInt 0…2554
Value 1unsignedInt 0…2551
Dimmer steplist100%
Number of valueslist4
Number of valueslist1
Scene numberlist1
Action 3 (long press)listNone
ValuelistOFF
Action 3listNone
Action 2listNone
ValuelistUp
Action 1 (long press)listNone
Action 1listNone
Action 2 (long press)listNone
ValueunsignedInt 0…1000
ModelistOFF
ValueunsignedInt 0…2550
Alarm 2 colorlistOFF
LED modelistDay
Alarm 1 colorlistOFF
ON colorlistRed
OFF modelistSteady
Alarm 1 blink periodlist1 s
Alarm 2 modelistSteady
OFF colorlistBlue
Alarm 1 modelistSteady
Alarm 2 blink periodlist1 s
LEDlistEnable
Device locklistDisable
ON blink periodlist1 s
ON modelistSteady
LED brightnesslistStandard
OFF blink periodlist1 s
Long press modelistDisable
Function position 2listSwitch
Long press modelistNo forcing, OFF
LoadedParametersunsignedInt 0…255170
HardwareChecklistHardwareType

Version history

ApplicationApp noFingerprintFirst seenSizeFile
Ave. Toggle push-buttons 2 ch 1 mod. S44 0.1 latest$00045D1B2026-11-25214 KBDownload

About this file

This is the official ETS product database for the Ave S.p.A. 444KNXT2OT Toggle push-buttons 1 mod. S44 (444KNXT2OT), published by the manufacturer in the KNX online catalog. To use it, open ETS, go to Catalogs → Import and choose the downloaded .knxprod file. The device then appears in your catalog and can be added to a project. Older versions are kept so existing projects can be matched to the application program they were commissioned with.

More from Ave S.p.A.

All Ave S.p.A. products