IMPZ2 REG 60201202
Arcus-eds · Order number 60201202 · IMPZ2
Download .knxprod IMPZ_DUO 0.1 · 68 KB
Product
| Manufacturer | Arcus-eds |
|---|---|
| Product name | IMPZ2 REG |
| Order number | 60201202 |
| Hardware | IMPZx |
| Medium | Twisted Pair |
| Rail mounted | Yes |
| Width (mm) | 35 |
| Registration | Certified |
| Catalog entry | M-0076_H-0001-0_HP-0029-01-1BB1_CI-60201202-2 |
| Fingerprint | 1BB1 |
| SHA-256 | 94579f47d375ab136e0e1f047e1ab6d8078bd5607e5e9bc5c7b4cad7f6fbdfd8 |
| First seen | 2026-11-25 |
| Markets | 18 markets |
Application program: IMPZ_DUO 0.1
| Application number | $0029 |
|---|---|
| Version | 0.1 |
| Mask version | MV-0701 (7.1) |
| KNX Data Secure | No |
| Minimum ETS version | 3.0d |
| Parameters | 33 |
| Group objects | 31 |
Group objects (31)
| No | Name | Function | Size | DPT | Flags |
|---|---|---|---|---|---|
| 0 | Value Channel 1 | Counted Value | 4 Bytes | 14.5 amplitude | CRT |
| 0 | Value Scale 1 | Counted Value | 4 Bytes | 14.5 amplitude | CRT |
| 1 | Value Channel 2 | Counted Value | 4 Bytes | 14.5 amplitude | CRT |
| 1 | Value Scale 2 | Counted Value | 4 Bytes | 14.5 amplitude | CRT |
| 2 | Flow Rate Channel 1 | Calculated Flow Rate | 4 Bytes | 14.5 amplitude | CRT |
| 2 | Flow Rate | Calculated Flow Rate | 4 Bytes | 14.5 amplitude | CRT |
| 3 | Flow Rate Channel 2 | Calculated Flow Rate | 4 Bytes | 14.5 amplitude | CRT |
| 4 | Reference Value Channel 1 | Consumption Last Due Date | 4 Bytes | 14.5 amplitude | CRT |
| 4 | Reference Value Scale 1 | Consumption Last Due Date | 4 Bytes | 14.5 amplitude | CRT |
| 5 | Reference Value Channel 2 | Consumption Last Due Date | 4 Bytes | 14.5 amplitude | CRT |
| 5 | Reference Value Scale 2 | Consumption Last Due Date | 4 Bytes | 14.5 amplitude | CRT |
| 6 | Consumption Value Channel 1 | Consumption Value | 4 Bytes | 14.5 amplitude | CRT |
| 6 | Consumption Value Scale 1 | Consumption Value | 4 Bytes | 14.5 amplitude | CRT |
| 7 | Consumption Value Channel 2 | Consumption Value | 4 Bytes | 14.5 amplitude | CRT |
| 7 | Consumption Value Scale 2 | Consumption Value | 4 Bytes | 14.5 amplitude | CRT |
| 8 | Serialnumber Channel 1 | Serialnumber | 14 Bytes | 16.0 Character String (ASCII) | CRT |
| 8 | Serialnumber | Serialnumber | 14 Bytes | 16.0 Character String (ASCII) | CRT |
| 9 | Serialnumber Channel 2 | Serialnumber | 14 Bytes | 16.0 Character String (ASCII) | CRT |
| 9 | Selected Scale | Scale | 1 Bit | 1.1 switch | CRT |
| 10 | Limit Alarm Channel 1 | Limit | 1 Bit | 1.1 switch | CRWU |
| 10 | Limit Alarm Scale 1 | Limit | 1 Bit | 1.1 switch | CRWU |
| 11 | Limit Alarm Channel 2 | Limit | 1 Bit | 1.1 switch | CRWU |
| 11 | Limit Alarm Scale 2 | Limit | 1 Bit | 1.1 switch | CRWU |
| 12 | Current Time | Time | 3 Bytes | 10.1 time of day | CRWTU |
| 13 | Current Date | Date | 3 Bytes | 11.1 date | CRWTU |
| 14 | Last Reference Date | Due Date | 3 Bytes | 11.1 date | CRT |
| 15 | Next Reference Date | Due Date | 3 Bytes | 11.1 date | CRWTU |
| 16 | Consumption Reset | Consumption Reset | 2 Bytes | 7.1 pulses | CRWU |
| 17 | Consumption Reset Time | Reset Time | 3 Bytes | 10.1 time of day | CRT |
| 18 | Consumption Reset Date | Reset Date | 3 Bytes | 11.1 date | CRT |
| 19 | Alarm Profile | Limit Selection | 1 Bit | 1.1 switch | CRWU |
Parameters (26)
| Parameter | Type | Default |
|---|---|---|
| Use Daylight Saving Time | list | Yes |
| Reset Pin [ 0 without Pin ] | unsignedInt 0…65535 | 0 |
| Type of Counter | list | 2 Independent Counters |
| If Flowrate drops | list | Send Nothing |
| Use Limit Profile | list | No |
| Sending Values Cyclically | list | Do Not Send |
| Counts per Unit | unsignedInt 0…99 | 10 |
| [ Exponent ] | list | * 1 |
| Preset Counter Value [ 0 - no changes ] | unsignedInt 0…4294967295 | 0 |
| Type of Flow Rate Measurement | list | Volumetric Flow |
| Flow Measurement Period | list | Per Second |
| Use of Limit 1 | list | Value Limit |
| Limit 1 | unsignedInt 0…99 | 0 |
| Use of Limit 2 | list | Value Limit |
| Limit 2 | unsignedInt 0…99 | 0 |
| Preset Counter Value Scale 1 [ 0 - no changes ] | unsignedInt 0…4294967295 | 0 |
| Preset Counter Value Scale 2 [ 0 - no changes ] | unsignedInt 0…4294967295 | 0 |
| Type of Flow Rate | list | Volumetric Flow |
| Use of Limit 1 Scale 1 | list | Value Limit |
| Limit 1 Scale 1 | unsignedInt 0…99 | 0 |
| Use of Limit 2 Scale 1 | list | Value Limit |
| Limit 2 Scale 1 | unsignedInt 0…99 | 0 |
| Use of Limit 1 Scale 2 | list | Value Limit |
| Limit 1 Scale 2 | unsignedInt 0…99 | 0 |
| Use of Limit 2 Scale 2 | list | Value Limit |
| Limit 2 Scale 2 | unsignedInt 0…99 | 0 |
Version history
| Application | App no | Fingerprint | First seen | Size | File |
|---|---|---|---|---|---|
| IMPZ_DUO 0.1 latest | $0029 | 1BB1 | 2026-11-25 | 68 KB | Download |
About this file
This is the official ETS product database for the Arcus-eds IMPZ2 REG (60201202), published by the manufacturer in the KNX online catalog. To use it, open ETS, go to Catalogs → Import and choose the downloaded .knxprod file. The device then appears in your catalog and can be added to a project. Older versions are kept so existing projects can be matched to the application program they were commissioned with.
More from Arcus-eds
- IMPZ2 SK01 60201201
- SK80_F 1180440001
- Touch_IT-Plugin 22310xxx
- Sensor Temperature IP65 30101xxx
- Sensor Temperature SK03 30103xxx
- Sensor Temperature/Humidity 30201xxx
- Sensor Temperature/Humidity SK03 30203xxx
- Sensor Temperature/Humidity/Climatecontrol IP65 30301xxx
- Sensor Temperature/Humidity/Climatecontrol SK02 30302xxx
- Sensor Temperature/Humidity/Climatecontrol SK03 30303xxx
- Sensor Temperature/Humidity/Climatecontrol+ IP65 30401xxx
- HLK305-FC 305xxxxFC