6122/20-500 Busch-Watchdog, flush-mounted 6122/20-500
ABB AG - STOTZ-KONTAKT · Order number 6122/20-500 · User Operation Millenium › Motion Detectors
Download .knxprod Switching, value, cyclic, message, twilight/6.1 5.3 · 131 KB
Product
| Manufacturer | ABB AG - STOTZ-KONTAKT |
|---|---|
| Product name | 6122/20-500 Busch-Watchdog, flush-mounted |
| Order number | 6122/20-500 |
| Hardware | 6122/20-500 Busch-Wächter, UP |
| Medium | Twisted Pair |
| Bus current (mA) | 4 |
| Rail mounted | No |
| Registration | Registered · 2015-02-27 |
| Languages | en-US, de-DE, es-ES, fr-FR, it-IT, nl-NL, pl-PL, ru-RU |
| Catalog entry | M-0002_H-6122.2F20.2D500-0-O0007_HP-6122-53-14C7-O0007-6122-63-2FD0-O0007_CI-6122.2F20.2D500-1 |
| Fingerprint | 14C7 |
| SHA-256 | 35f4771906c267dcdc51aaff6d9549908fb00bee8520034b1037a7f3204128b3 |
| First seen | 2026-11-25 |
| Markets | 59 markets |
Application program: Switching, value, cyclic, message, twilight/6.1 5.3
| Application number | $6122 |
|---|---|
| Version | 5.3 |
| Mask version | MV-07B0 (System B) |
| KNX Data Secure | No |
| Minimum ETS version | 4.0 |
| Parameters | 389 |
| Group objects | 64 |
Group objects (64)
| No | Name | Function | Size | DPT | Flags |
|---|---|---|---|---|---|
| 1 | Enable movement | 1 Bit | 1.1 switch | CWU | |
| 2 | Input switch-OFF delay | 2 Bytes | 7.5 time (s) | CWU | |
| 3 | Input Slave | 1 Bit | 1.1 switch | CWU | |
| 4 | Input actuator status | 1 Bit | 1.1 switch | CWU | |
| 5 | Input independent detection of brightness | 1 Bit | 1.1 switch | CWU | |
| 6 | Input external brightness | 2 Bytes | DPT.9 | CWU | |
| 7 | Input brightness threshold external | 2 Bytes | DPT.9 | CWU | |
| 8 | Input brightness threshold internal | 2 Bytes | DPT.9 | CWU | |
| 9 | Output status LED | 1 Bit | 1.1 switch | CT | |
| 10 | Output movement (Master) | 1 Bit | 1.1 switch | CT | |
| 10 | Output movement (Master) | 1 Byte | 5.1 percentage (0..100%) | CT | |
| 10 | Output movement (Master) | 1 Byte | 5.10 counter pulses (0..255) | CT | |
| 10 | Output movement (Master) | 1 Byte | 18.1 scene control | CT | |
| 11 | Output movement (Slave) | 1 Bit | 1.1 switch | CWT | |
| 12 | Input switchover manual operation | 1 Bit | 1.1 switch | CWU | |
| 13 | Input external button | 1 Bit | 1.1 switch | CWU | |
| 14 | Enable movement | 1 Bit | 1.1 switch | CWU | |
| 15 | Input switch-OFF delay | 2 Bytes | 7.5 time (s) | CWU | |
| 16 | Input Slave | 1 Bit | 1.1 switch | CWU | |
| 17 | Input actuator status | 1 Bit | 1.1 switch | CWU | |
| 18 | Input independent detection of brightness | 1 Bit | 1.1 switch | CWU | |
| 19 | Input external brightness | 2 Bytes | DPT.9 | CWU | |
| 20 | Input brightness threshold external | 2 Bytes | DPT.9 | CWU | |
| 21 | Input brightness threshold internal | 2 Bytes | DPT.9 | CWU | |
| 22 | Output status LED | 1 Bit | 1.1 switch | CT | |
| 23 | Output movement (Master) | 1 Bit | 1.1 switch | CT | |
| 23 | Output movement (Master) | 1 Byte | 5.1 percentage (0..100%) | CT | |
| 23 | Output movement (Master) | 1 Byte | 5.10 counter pulses (0..255) | CT | |
| 23 | Output movement (Master) | 1 Byte | 18.1 scene control | CT | |
| 24 | Output movement (Slave) | 1 Bit | 1.1 switch | CWT | |
| 25 | Input switchover manual operation | 1 Bit | 1.1 switch | CWU | |
| 26 | Input external button | 1 Bit | 1.1 switch | CWU | |
| 27 | Enable movement | 1 Bit | 1.1 switch | CWU | |
| 28 | Input switch-OFF delay | 2 Bytes | 7.5 time (s) | CWU | |
| 29 | Input Slave | 1 Bit | 1.1 switch | CWU | |
| 30 | Input actuator status | 1 Bit | 1.1 switch | CWU | |
| 31 | Input independent detection of brightness | 1 Bit | 1.1 switch | CWU | |
| 32 | Input external brightness | 2 Bytes | DPT.9 | CWU | |
| 33 | Input brightness threshold external | 2 Bytes | DPT.9 | CWU | |
| 34 | Input brightness threshold internal | 2 Bytes | DPT.9 | CWU | |
| 35 | Output status LED | 1 Bit | 1.1 switch | CT | |
| 36 | Output movement (Master) | 1 Bit | 1.1 switch | CT | |
| 36 | Output movement (Master) | 1 Byte | 5.1 percentage (0..100%) | CT | |
| 36 | Output movement (Master) | 1 Byte | 5.10 counter pulses (0..255) | CT | |
| 36 | Output movement (Master) | 1 Byte | 18.1 scene control | CT | |
| 37 | Output movement (Slave) | 1 Bit | 1.1 switch | CWT | |
| 38 | Input switchover manual operation | 1 Bit | 1.1 switch | CWU | |
| 39 | Input external button | 1 Bit | 1.1 switch | CWU | |
| 40 | Enable movement | 1 Bit | 1.1 switch | CWU | |
| 41 | Input switch-OFF delay | 2 Bytes | 7.5 time (s) | CWU | |
| 42 | Input Slave | 1 Bit | 1.1 switch | CWU | |
| 43 | Input actuator status | 1 Bit | 1.1 switch | CWU | |
| 44 | Input independent detection of brightness | 1 Bit | 1.1 switch | CWU | |
| 45 | Input external brightness | 2 Bytes | DPT.9 | CWU | |
| 46 | Input brightness threshold external | 2 Bytes | DPT.9 | CWU | |
| 47 | Input brightness threshold internal | 2 Bytes | DPT.9 | CWU | |
| 48 | Output status LED | 1 Bit | 1.1 switch | CT | |
| 49 | Output movement (Master) | 1 Bit | 1.1 switch | CT | |
| 49 | Output movement (Master) | 1 Byte | 5.1 percentage (0..100%) | CT | |
| 49 | Output movement (Master) | 1 Byte | 5.10 counter pulses (0..255) | CT | |
| 49 | Output movement (Master) | 1 Byte | 18.1 scene control | CT | |
| 50 | Output movement (Slave) | 1 Bit | 1.1 switch | CWT | |
| 51 | Input switchover manual operation | 1 Bit | 1.1 switch | CWU | |
| 52 | Input external button | 1 Bit | 1.1 switch | CWU |
Parameters (66)
| Parameter | Type | Default |
|---|---|---|
| Application | list | Movement detector |
| Size of structure | unsignedInt 0…65535 | 28 |
| Number of sensors | unsignedInt 0…15 | 2 |
| Type of output | list | Master |
| Input Slave | list | deactivated |
| Output object | list | 1 bit |
| Output object sends at | list | Switching On/Off |
| CalcParam | unsignedInt 0…255 | 0 |
| Value for switch on | list | On |
| Value for switch on (%) | unsignedInt 0…100 | 100 |
| Value for switch on (%) | unsignedInt 0…255 | 255 |
| Value for switch on | unsignedInt 0…255 | 255 |
| Value for switch on | list | 1 |
| Sending value for switch-on cyclic | list | deactivated |
| Value for switch off | list | Off |
| Value for switch off (%) | unsignedInt 0…100 | 0 |
| Value for switch off (%) | unsignedInt 0…255 | 0 |
| Value for switch off | unsignedInt 0…255 | 0 |
| Value for switch off | list | 1 |
| Send value for switch-off cyclic | list | deactivated |
| Cyclical repeating time | time | 90 |
| Switch-OFF delay | time | 180 |
| Brightness threshold internal (lux) | float 1…500 | 5 |
| Sensitivity of watchdog | list | High |
| High sensitivity | unsignedInt 0…65535 | 65535 |
| Mean sensitivity | unsignedInt 0…65535 | 39321 |
| Low sensitivity | unsignedInt 0…65535 | 28270 |
| Extended parameter settings | list | deactivated |
| Extended parameters status | list | deactivated |
| Extended parameters Brightness | list | deactivated |
| Extended parameters external button | list | deactivated |
| Operating mode | list | Automatic |
| Setting the switch-OFF delay via | list | ETS |
| Object for timeout | list | deactivated |
| Setting the brightness-value threshold via | list | ETS |
| Operating mode of the movement detector | list | Normal |
| Activating sensors | list | Both |
| Enable object movement detector | list | deactivated |
| Enable with | list | ON telegram |
| After bus voltage recovery movement detector is | list | enabled |
| Output sends at enable | list | Current status |
| Output sends at blockage | list | No telegram |
| Dead-time (ms) | unsignedInt 100…60000 | 1250 |
| Dead-time (ms) | unsignedInt 100…60000 | 10000 |
| Overwrite settings for download | list | activated |
| activate input for actuator status | list | deactivated |
| LED status | list | deactivated |
| Object for brightness-independant detection | list | deactivated |
| Brightness-independent detection activation with | list | On telegram |
| Brightness independent detection after busvoltage return | list | deactivated |
| Input Slave takes the brightness into consideration | list | deactivated |
| activating / connection int. or ext. brightness | list | internal only |
| Object for internal brightness threshold | list | deactivated |
| Object for external brightness threshold | list | deactivated |
| Brightness threshold external (lux) | float 1…500 | 5 |
| Object input external button | list | deactivated |
| Object input external button | list | activated |
| External button switches on with | list | On telegram |
| Object input manual operation | list | deactivated |
| Manual mode is activated with | list | On telegram |
| Config length | unsignedInt 0…65535 | 14 |
| Config | unsignedInt 0…4294967295 | 1638900 |
| Config | unsignedInt 0…65535 | 2000 |
| Config | unsignedInt 0…4294967295 | 0 |
| Config | unsignedInt 0…65535 | 0 |
| Application | list | Inactive |
Application program: Switching, value, cyclic, message, twilight/7.1 6.3
| Application number | $6122 |
|---|---|
| Version | 6.3 |
| Mask version | MV-07B0 (System B) |
| KNX Data Secure | No |
| Minimum ETS version | 4.0 |
| Parameters | 0 |
| Group objects | 0 |
Group objects (0)
| No | Name | Function | Size | DPT | Flags |
|---|
Parameters (0)
| Parameter | Type | Default |
|---|
Version history
| Application | App no | Fingerprint | First seen | Size | File |
|---|---|---|---|---|---|
| Switching, value, cyclic, message, twilight/6.1 5.3 latest | $6122 | 14C7 | 2026-11-25 | 131 KB | Download |
About this file
This is the official ETS product database for the ABB AG - STOTZ-KONTAKT 6122/20-500 Busch-Watchdog, flush-mounted (6122/20-500), published by the manufacturer in the KNX online catalog. To use it, open ETS, go to Catalogs → Import and choose the downloaded .knxprod file. The device then appears in your catalog and can be added to a project. Older versions are kept so existing projects can be matched to the application program they were commissioned with.
More from ABB AG - STOTZ-KONTAKT
- 6124/08-500 Room temperature controller 6124/08-500
- 6125/20 Millenium Control element 2gang, flush-mounted 6125/20-500
- 6126/20 Millenium Control element 4gang, flush-mounted 6126/20-500
- 6129/20 Millenium Control element 6gang, flush-mounted 6129/20-500
- 6129/21 Millenium Control element 6gang with IR, flush-mounted 6129/21-500
- PS5604-KNX AC500 1SAP 195 800 R0101
- EG/A32.2.1 KNX/EnOcean Gateway 2 CDG 120 047 R0011
- Sidus KNX Tastsensor 1-/2-fach, UP 2CCA 380 319 R0001
- Sidus KNX control element 2/4gang, flush-mounted 2CCA 380 339 R0001
- Sidus KNX Tastsensor 4-/8-fach, UP 2CCA 380 375 R0001
- Sidus KNX Movement detector 180° flat 2CCA 388 975 R0001
- Sidus KNX Room temperature controller, FM 2CCA388429R0001