RM/S1.1 Room Master,Basic,MDRC 2CDG 110 094 R0011
ABB AG - STOTZ-KONTAKT · Order number 2CDG 110 094 R0011 · Multifunction Room Automation › Room Master Series
Room Master Basic/2.6a
Download .knxprod Room Master Basic/2.6a 2.6 · 410 KB
Product
| Manufacturer | ABB AG - STOTZ-KONTAKT |
|---|---|
| Product name | RM/S1.1 Room Master,Basic,MDRC |
| Order number | 2CDG 110 094 R0011 |
| Hardware | RM/S1.1 |
| Medium | Twisted Pair |
| Bus current (mA) | 12 |
| Rail mounted | Yes |
| Width (mm) | 144 |
| Registration | Certified |
| Languages | en-US, de-DE, es-ES, fr-FR, it-IT, nl-NL, pl-PL, ru-RU |
| Catalog entry | M-0002_H-2CDG.20110.20094.20R0011-1_HP-A053-26-A2A4_CI-2CDG.20110.20094.20R0011-1 |
| Fingerprint | A2A4 |
| SHA-256 | 3104b2ba6754206b7cdb003ba49dd6c7ae6cebcd9857b0f346dda9586ff0161c |
| First seen | 2026-11-25 |
| Markets | 59 markets |
Application program: Room Master Basic/2.6a 2.6
| Application number | $A053 |
|---|---|
| Version | 2.6 |
| Mask version | MV-0701 (7.1) |
| KNX Data Secure | No |
| Parameters | 1811 |
| Group objects | 387 |
Group objects (387)
| No | Name | Function | Size | DPT | Flags |
|---|---|---|---|---|---|
| 0 | System | In operation | 1 Bit | CT | |
| 1 | General | Request status values | 1 Bit | CW | |
| 2 | Room Scenario | 1...10 recall | 1 Byte | CW | |
| 3 | Room Scenario | Switch 1 | 1 Bit | CT | |
| 4 | Room Scenario | Switch 2 | 1 Bit | CT | |
| 5 | Room Scenario | Automatic Blind recall | 1 Bit | CT | |
| 6 | Room scenario | KNX scene recall | 1 Byte | CT | |
| 7 | Room Scenario | Internal block recall | 1 Bit | CT | |
| 8 | Room Scenario | Thermostat ON/OFF | 1 Bit | CT | |
| 9 | Room Scenario | Thermostat operating mode | 1 Byte | CT | |
| 10 | Output D | Switch | 1 Bit | CW | |
| 10 | Fan | Fan speed switch | 1 Byte | CW | |
| 11 | Output D | Permanent ON | 1 Bit | CW | |
| 11 | Fan | Switch | 1 Bit | CW | |
| 11 | Fan | Switch speed 1 | 1 Bit | CW | |
| 12 | Output D | Disable function Time | 1 Bit | CW | |
| 12 | Fan | Switch speed 2 | 1 Bit | CW | |
| 13 | Output D | Scene | 1 Byte | CW | |
| 13 | Fan | Switch speed 3 | 1 Bit | CW | |
| 14 | Output D | Forced operation | 1 Bit | CW | |
| 14 | Output D | Forced operation | 2 Bit | CW | |
| 14 | Fan | Fan speed UP/DOWN | 1 Bit | CW | |
| 15 | Output D | Status Switch | 1 Bit | CRT | |
| 15 | Fan | Status fan ON/OFF | 1 Bit | CT | |
| 16 | Output E | Switch | 1 Bit | CW | |
| 16 | Fan | Status fan speed | 1 Byte | CRT | |
| 17 | Output E | Permanent ON | 1 Bit | CW | |
| 17 | Fan | Status fan speed 1 | 1 Bit | CRT | |
| 18 | Output E | Disable function Time | 1 Bit | CW | |
| 18 | Fan | Status fan speed 2 | 1 Bit | CRT | |
| 19 | Output E | Scene | 1 Byte | CW | |
| 19 | Fan | Status fan speed 3 | 1 Bit | CRT | |
| 20 | Output E | Forced operation | 1 Bit | CW | |
| 20 | Output E | Forced operation | 2 Bit | CW | |
| 20 | Object 20 | Dummy | 1 Bit | ||
| 21 | Output E | Status Switch | 1 Bit | CRT | |
| 21 | Fan | Limitation 1 | 1 Bit | CW | |
| 22 | Output F | Switch | 1 Bit | CW | |
| 22 | Fan | Limitation 2 | 1 Bit | CW | |
| 23 | Output F | Permanent ON | 1 Bit | CW | |
| 23 | Fan | Limitation 3 | 1 Bit | CW | |
| 24 | Output F | Disable function Time | 1 Bit | CW | |
| 24 | Fan | Limitation 4 | 1 Bit | CW | |
| 25 | Output F | Scene | 1 Byte | CW | |
| 25 | Fan | Forced operation | 1 Bit | CW | |
| 26 | Output F | Forced operation | 1 Bit | CW | |
| 26 | Output F | Forced operation | 2 Bit | CW | |
| 26 | Fan | Automatic ON/OFF | 1 Bit | CW | |
| 27 | Output F | Status Switch | 1 Bit | CRT | |
| 27 | Fan | Status automatic | 1 Bit | CRT | |
| 28 | Fan | Status byte mode | 1 Byte | CRT | |
| 29 | Control input | Control value HEATING/COOLING | 1 Byte | CW | |
| 29 | Control input | Control value HEATING | 1 Byte | CW | |
| 30 | Control input | Control value COOLING (extra!) | 1 Byte | CW | |
| 30 | Control input | Control value COOLING | 1 Byte | CW | |
| 31 | Control input | Toggle HEATING/COOLING | 1 Bit | CW | |
| 32 | Control input | Fault control value | 1 Bit | CRT | |
| 33 | Valve HEATING | Block | 1 Bit | CW | |
| 34 | Valve HEATING | Forced operation | 1 Bit | CW | |
| 35 | Valve HEATING | Trigger valve purge | 1 Bit | CW | |
| 36 | Valve HEATING | Status valve purge | 1 Bit | CRT | |
| 37 | Valve HEATING | Status valve position | 1 Byte | CRT | |
| 37 | Valve HEATING | Status valve position | 1 Bit | CRT | |
| 38 | Valve HEATING | Overload | 1 Bit | CT | |
| 39 | Valve COOLING | Block | 1 Bit | CW | |
| 40 | Valve COOLING | Forced operation | 1 Bit | CW | |
| 41 | Valve COOLING | Trigger valve purge | 1 Bit | CW | |
| 42 | Valve COOLING | Status valve purge | 1 Bit | CRT | |
| 43 | Valve COOLING | Status valve position | 1 Byte | CRT | |
| 43 | Valve COOLING | Status valve position | 1 Bit | CRT | |
| 44 | Valve COOLING | Overload | 1 Bit | CT | |
| 45 | Input a: sent Value | Block | 1 Bit | CW | |
| 45 | Input a: Blind Sensor | Block | 1 Bit | CW | |
| 45 | Input a: Switch Sensor | Block | 1 Bit | CW | |
| 45 | Input a: Switch/Dim Sensor | Block | 1 Bit | CW | |
| 46 | Input a: Value/Forced op. | Value 1, unsigned | 2 Bytes | CT | |
| 46 | Input a: Value/Forced op. | Value 1, floating point | 2 Bytes | CT | |
| 46 | Input a: Value/Forced op. | Value 1, forced operation | 2 Bit | CT | |
| 46 | Input a: Value/Forced op. | Value 1, signed | 4 Bytes | CT | |
| 46 | Input a: Value/Forced op. | Value 1, signed | 1 Byte | CT | |
| 46 | Input a: Value/Forced op. | Value 1, unsigned | 1 Byte | CT | |
| 46 | Input a: Value/Forced op. | Value 1, scene number | 1 Byte | CT | |
| 46 | Input a: Value/Forced op. | Value 1 | 1 Bit | CT | |
| 46 | Input a: Value/Forced op. | Value 1, time of day, weekday | 3 Bytes | CT | |
| 46 | Input a: Value/Forced op. | Value 1, signed | 2 Bytes | CT | |
| 46 | Input a: Value/Forced op. | Value 1, unsigned | 4 Bytes | CT | |
| 46 | Input a: Blind Sensor | Blind UP/DOWN | 1 Bit | CWT | |
| 46 | Input a: Switch Sensor | Switch 1 | 1 Bit | CWT | |
| 46 | Input a: Switch/Dim Sensor | Switch | 1 Bit | CWT | |
| 47 | Input a: Value/Forced op. | Value 2, scene number | 1 Byte | CT | |
| 47 | Input a: Value/Forced op. | Value 2, unsigned | 2 Bytes | CT | |
| 47 | Input a: Value/Forced op. | Value 2, signed | 2 Bytes | CT | |
| 47 | Input a: Value/Forced op. | Value 2, unsigned | 4 Bytes | CT | |
| 47 | Input a: Value/Forced op. | Value 2, floating point | 2 Bytes | CT | |
| 47 | Input a: Value/Forced op. | Value 2, unsigned | 1 Byte | CT | |
| 47 | Input a: Value/Forced op. | Value 2, signed | 1 Byte | CT | |
| 47 | Input a: Value/Forced op. | Value 2, signed | 4 Bytes | CT | |
| 47 | Input a: Value/Forced op. | Value 2, time of day, weekday | 3 Bytes | CT | |
| 47 | Input a: Value/Forced op. | Value 2 | 1 Bit | CT | |
| 47 | Input a: Value/Forced op. | Value 2, forced operation | 2 Bit | CT | |
| 47 | Input a: Blind Sensor | STOP/Slat adjustment | 1 Bit | CT | |
| 47 | Input a: Switch Sensor | Switch 2 | 1 Bit | CWT | |
| 47 | Input a: Switch/Dim Sensor | Dimming | 4 Bit | CT | |
| 48 | Input a: Blind Sensor | Upper limit position | 1 Bit | CW | |
| 48 | Input a: Switch Sensor | Switch 3 | 1 Bit | CWT | |
| 49 | Input a: Blind Sensor | Lower limit position | 1 Bit | CW | |
| 49 | Input a: Switch Sensor | Event 0/1 started | 1 Bit | CW | |
| 50 | Input b: sent Value | Block | 1 Bit | CW | |
| 50 | Input b: Blind Sensor | Block | 1 Bit | CW | |
| 50 | Input b: Switch/Dim Sensor | Block | 1 Bit | CW | |
| 50 | Input b: Switch Sensor | Block | 1 Bit | CW | |
| 51 | Input b: Value/Forced op. | Value 1, unsigned | 2 Bytes | CT | |
| 51 | Input b: Value/Forced op. | Value 1, floating point | 2 Bytes | CT | |
| 51 | Input b: Value/Forced op. | Value 1, forced operation | 2 Bit | CT | |
| 51 | Input b: Value/Forced op. | Value 1, signed | 4 Bytes | CT | |
| 51 | Input b: Value/Forced op. | Value 1, signed | 2 Bytes | CT | |
| 51 | Input b: Value/Forced op. | Value 1, unsigned | 4 Bytes | CT | |
| 51 | Input b: Value/Forced op. | Value 1, signed | 1 Byte | CT | |
| 51 | Input b: Value/Forced op. | Value 1, unsigned | 1 Byte | CT | |
| 51 | Input b: Value/Forced op. | Value 1, scene number | 1 Byte | CT | |
| 51 | Input b: Value/Forced op. | Value 1 | 1 Bit | CT | |
| 51 | Input b: Value/Forced op. | Value 1, time of day, weekday | 3 Bytes | CT | |
| 51 | Input b: Blind Sensor | Blind UP/DOWN | 1 Bit | CWT | |
| 51 | Input b: Switch/Dim Sensor | Switch | 1 Bit | CWT | |
| 51 | Input b: Switch Sensor | Switch 1 | 1 Bit | CWT | |
| 52 | Input b: Value/Forced op. | Value 2, time of day, weekday | 3 Bytes | CT | |
| 52 | Input b: Value/Forced op. | Value 2 | 1 Bit | CT | |
| 52 | Input b: Value/Forced op. | Value 2, forced operation | 2 Bit | CT | |
| 52 | Input b: Value/Forced op. | Value 2, scene number | 1 Byte | CT | |
| 52 | Input b: Value/Forced op. | Value 2, unsigned | 2 Bytes | CT | |
| 52 | Input b: Value/Forced op. | Value 2, signed | 2 Bytes | CT | |
| 52 | Input b: Value/Forced op. | Value 2, unsigned | 4 Bytes | CT | |
| 52 | Input b: Value/Forced op. | Value 2, floating point | 2 Bytes | CT | |
| 52 | Input b: Value/Forced op. | Value 2, unsigned | 1 Byte | CT | |
| 52 | Input b: Value/Forced op. | Value 2, signed | 1 Byte | CT | |
| 52 | Input b: Value/Forced op. | Value 2, signed | 4 Bytes | CT | |
| 52 | Input b: Blind Sensor | STOP/Slat adjustment | 1 Bit | CT | |
| 52 | Input b: Switch/Dim Sensor | Dimming | 4 Bit | CT | |
| 52 | Input b: Switch Sensor | Switch 2 | 1 Bit | CWT | |
| 53 | Input b: Blind Sensor | Upper limit position | 1 Bit | CW | |
| 53 | Input b: Switch Sensor | Switch 3 | 1 Bit | CWT | |
| 54 | Input b: Blind Sensor | Lower limit position | 1 Bit | CW | |
| 54 | Input b: Switch Sensor | Event 0/1 started | 1 Bit | CW | |
| 55 | Input c: sent Value | Block | 1 Bit | CW | |
| 55 | Input c: Switch/Dim Sensor | Block | 1 Bit | CW | |
| 55 | Input c: Blind Sensor | Block | 1 Bit | CW | |
| 55 | Input c: Switch Sensor | Block | 1 Bit | CW | |
| 56 | Input c: Blind Sensor | Shutter UP/DOWN | 1 Bit | CWT | |
| 56 | Input c: Value/Forced op. | Value 1, floating point | 2 Bytes | CT | |
| 56 | Input c: Value/Forced op. | Value 1, forced operation | 2 Bit | CT | |
| 56 | Input c: Value/Forced op. | Value 1, signed | 4 Bytes | CT | |
| 56 | Input c: Value/Forced op. | Value 1, signed | 1 Byte | CT | |
| 56 | Input c: Value/Forced op. | Value 1, unsigned | 1 Byte | CT | |
| 56 | Input c: Value/Forced op. | Value 1, scene number | 1 Byte | CT | |
| 56 | Input c: Value/Forced op. | Value 1 | 1 Bit | CT | |
| 56 | Input c: Value/Forced op. | Value 1, time of day, weekday | 3 Bytes | CT | |
| 56 | Input c: Value/Forced op. | Value 1, signed | 2 Bytes | CT | |
| 56 | Input c: Value/Forced op. | Value 1, unsigned | 4 Bytes | CT | |
| 56 | Input c: Value/Forced op. | Value 1, unsigned | 2 Bytes | CT | |
| 56 | Input c: Switch/Dim Sensor | Switch | 1 Bit | CWT | |
| 56 | Input c: Switch Sensor | Switch 1 | 1 Bit | CWT | |
| 57 | Input c: Blind Sensor | STOP/Slat adjustment | 1 Bit | CT | |
| 57 | Input c: Value/Forced op. | Value 2, scene number | 1 Byte | CT | |
| 57 | Input c: Value/Forced op. | Value 2, unsigned | 2 Bytes | CT | |
| 57 | Input c: Value/Forced op. | Value 2, signed | 2 Bytes | CT | |
| 57 | Input c: Value/Forced op. | Value 2, unsigned | 4 Bytes | CT | |
| 57 | Input c: Value/Forced op. | Value 2, floating point | 2 Bytes | CT | |
| 57 | Input c: Value/Forced op. | Value 2, unsigned | 1 Byte | CT | |
| 57 | Input c: Value/Forced op. | Value 2, signed | 1 Byte | CT | |
| 57 | Input c: Value/Forced op. | Value 2, signed | 4 Bytes | CT | |
| 57 | Input c: Value/Forced op. | Value 2, time of day, weekday | 3 Bytes | CT | |
| 57 | Input c: Value/Forced op. | Value 2 | 1 Bit | CT | |
| 57 | Input c: Value/Forced op. | Value 2, forced operation | 2 Bit | CT | |
| 57 | Input c: Switch/Dim Sensor | Dimming | 4 Bit | CT | |
| 57 | Input c: Switch Sensor | Switch 2 | 1 Bit | CWT | |
| 58 | Input c: Blind Sensor | Upper limit position | 1 Bit | CW | |
| 58 | Input c: Switch Sensor | Switch 3 | 1 Bit | CWT | |
| 59 | Input c: Blind Sensor | Lower limit position | 1 Bit | CW | |
| 59 | Input c: Switch Sensor | Event 0/1 started | 1 Bit | CW | |
| 60 | Input d: sent Value | Block | 1 Bit | CW | |
| 60 | Input d: Blind Sensor | Block | 1 Bit | CW | |
| 60 | Input d: Switch/Dim Sensor | Block | 1 Bit | CW | |
| 60 | Input d: Switch Sensor | Block | 1 Bit | CW | |
| 61 | Input d: Value/Forced op. | Value 1, time of day, weekday | 3 Bytes | CT | |
| 61 | Input d: Value/Forced op. | Value 1, signed | 2 Bytes | CT | |
| 61 | Input d: Value/Forced op. | Value 1, unsigned | 4 Bytes | CT | |
| 61 | Input d: Value/Forced op. | Value 1, unsigned | 2 Bytes | CT | |
| 61 | Input d: Value/Forced op. | Value 1, floating point | 2 Bytes | CT | |
| 61 | Input d: Value/Forced op. | Value 1, forced operation | 2 Bit | CT | |
| 61 | Input d: Value/Forced op. | Value 1, signed | 4 Bytes | CT | |
| 61 | Input d: Value/Forced op. | Value 1, signed | 1 Byte | CT | |
| 61 | Input d: Value/Forced op. | Value 1, unsigned | 1 Byte | CT | |
| 61 | Input d: Value/Forced op. | Value 1, scene number | 1 Byte | CT | |
| 61 | Input d: Value/Forced op. | Value 1 | 1 Bit | CT | |
| 61 | Input d: Blind Sensor | Shutter UP/DOWN | 1 Bit | CWT | |
| 61 | Input d: Switch/Dim Sensor | Switch | 1 Bit | CWT | |
| 61 | Input d: Switch Sensor | Switch 1 | 1 Bit | CWT | |
| 62 | Input d: Value/Forced op. | Value 2, scene number | 1 Byte | CT | |
| 62 | Input d: Value/Forced op. | Value 2, unsigned | 2 Bytes | CT | |
| 62 | Input d: Value/Forced op. | Value 2, signed | 2 Bytes | CT | |
| 62 | Input d: Value/Forced op. | Value 2, unsigned | 4 Bytes | CT | |
| 62 | Input d: Value/Forced op. | Value 2, floating point | 2 Bytes | CT | |
| 62 | Input d: Value/Forced op. | Value 2, unsigned | 1 Byte | CT | |
| 62 | Input d: Value/Forced op. | Value 2, signed | 1 Byte | CT | |
| 62 | Input d: Value/Forced op. | Value 2, signed | 4 Bytes | CT | |
| 62 | Input d: Value/Forced op. | Value 2, time of day, weekday | 3 Bytes | CT | |
| 62 | Input d: Value/Forced op. | Value 2 | 1 Bit | CT | |
| 62 | Input d: Value/Forced op. | Value 2, forced operation | 2 Bit | CT | |
| 62 | Input d: Blind Sensor | STOP/Slat adjustment | 1 Bit | CT | |
| 62 | Input d: Switch/Dim Sensor | Dimming | 4 Bit | CT | |
| 62 | Input d: Switch Sensor | Switch 2 | 1 Bit | CWT | |
| 63 | Input d: Blind Sensor | Upper limit position | 1 Bit | CW | |
| 63 | Input d: Switch Sensor | Switch 3 | 1 Bit | CWT | |
| 64 | Input d: Blind Sensor | Lower limit position | 1 Bit | CW | |
| 64 | Input d: Switch Sensor | Event 0/1 started | 1 Bit | CW | |
| 65 | Input e: Switch/Dim Sensor | Block | 1 Bit | CW | |
| 65 | Input e: Blind Sensor | Block | 1 Bit | CW | |
| 65 | Input e: sent Value | Block | 1 Bit | CW | |
| 65 | Input e: Switch Sensor | Block | 1 Bit | CW | |
| 66 | Input e: Switch/Dim Sensor | Switch | 1 Bit | CWT | |
| 66 | Input e: Blind Sensor | Shutter UP/DOWN | 1 Bit | CWT | |
| 66 | Input e: Value/Forced op. | Value 1, floating point | 2 Bytes | CT | |
| 66 | Input e: Value/Forced op. | Value 1, forced operation | 2 Bit | CT | |
| 66 | Input e: Value/Forced op. | Value 1, signed | 4 Bytes | CT | |
| 66 | Input e: Value/Forced op. | Value 1, signed | 1 Byte | CT | |
| 66 | Input e: Value/Forced op. | Value 1, unsigned | 1 Byte | CT | |
| 66 | Input e: Value/Forced op. | Value 1, scene number | 1 Byte | CT | |
| 66 | Input e: Value/Forced op. | Value 1 | 1 Bit | CT | |
| 66 | Input e: Value/Forced op. | Value 1, time of day, weekday | 3 Bytes | CT | |
| 66 | Input e: Value/Forced op. | Value 1, signed | 2 Bytes | CT | |
| 66 | Input e: Value/Forced op. | Value 1, unsigned | 4 Bytes | CT | |
| 66 | Input e: Value/Forced op. | Value 1, unsigned | 2 Bytes | CT | |
| 66 | Input e: Switch Sensor | Switch 1 | 1 Bit | CWT | |
| 67 | Input e: Switch/Dim Sensor | Dimming | 4 Bit | CT | |
| 67 | Input e: Blind Sensor | STOP/Slat adjustment | 1 Bit | CT | |
| 67 | Input e: Value/Forced op. | Value 2, scene number | 1 Byte | CT | |
| 67 | Input e: Value/Forced op. | Value 2, unsigned | 2 Bytes | CT | |
| 67 | Input e: Value/Forced op. | Value 2, signed | 2 Bytes | CT | |
| 67 | Input e: Value/Forced op. | Value 2, unsigned | 4 Bytes | CT | |
| 67 | Input e: Value/Forced op. | Value 2, floating point | 2 Bytes | CT | |
| 67 | Input e: Value/Forced op. | Value 2, unsigned | 1 Byte | CT | |
| 67 | Input e: Value/Forced op. | Value 2, signed | 1 Byte | CT | |
| 67 | Input e: Value/Forced op. | Value 2, signed | 4 Bytes | CT | |
| 67 | Input e: Value/Forced op. | Value 2, time of day, weekday | 3 Bytes | CT | |
| 67 | Input e: Value/Forced op. | Value 2 | 1 Bit | CT | |
| 67 | Input e: Value/Forced op. | Value 2, forced operation | 2 Bit | CT | |
| 67 | Input e: Switch Sensor | Switch 2 | 1 Bit | CWT | |
| 68 | Input e: Blind Sensor | Upper limit position | 1 Bit | CW | |
| 68 | Input e: Switch Sensor | Switch 3 | 1 Bit | CWT | |
| 69 | Input e: Blind Sensor | Lower limit position | 1 Bit | CW | |
| 69 | Input e: Switch Sensor | Event 0/1 started | 1 Bit | CW | |
| 70 | Input f: Switch/Dim Sensor | Block | 1 Bit | CW | |
| 70 | Input f: Blind Sensor | Block | 1 Bit | CW | |
| 70 | Input f: sent Value | Block | 1 Bit | CW | |
| 70 | Input f: Switch Sensor | Block | 1 Bit | CW | |
| 71 | Input f: Value/Forced op. | Value 1, scene number | 1 Byte | CT | |
| 71 | Input f: Value/Forced op. | Value 1, unsigned | 1 Byte | CT | |
| 71 | Input f: Value/Forced op. | Value 1 | 1 Bit | CT | |
| 71 | Input f: Value/Forced op. | Value 1, signed | 2 Bytes | CT | |
| 71 | Input f: Value/Forced op. | Value 1, unsigned | 4 Bytes | CT | |
| 71 | Input f: Value/Forced op. | Value 1, floating point | 2 Bytes | CT | |
| 71 | Input f: Value/Forced op. | Value 1, forced operation | 2 Bit | CT | |
| 71 | Input f: Value/Forced op. | Value 1, unsigned | 2 Bytes | CT | |
| 71 | Input f: Value/Forced op. | Value 1, time of day, weekday | 3 Bytes | CT | |
| 71 | Input f: Value/Forced op. | Value 1, signed | 4 Bytes | CT | |
| 71 | Input f: Value/Forced op. | Value 1, signed | 1 Byte | CT | |
| 71 | Input f: Blind Sensor | Shutter UP/DOWN | 1 Bit | CWT | |
| 71 | Input f: Switch/Dim Sensor | Switch | 1 Bit | CWT | |
| 71 | Input f: Switch Sensor | Switch 1 | 1 Bit | CWT | |
| 72 | Input f: Value/Forced op. | Value 2, unsigned | 1 Byte | CT | |
| 72 | Input f: Value/Forced op. | Value 2 | 1 Bit | CT | |
| 72 | Input f: Value/Forced op. | Value 2, signed | 2 Bytes | CT | |
| 72 | Input f: Value/Forced op. | Value 2, unsigned | 4 Bytes | CT | |
| 72 | Input f: Value/Forced op. | Value 2, floating point | 2 Bytes | CT | |
| 72 | Input f: Value/Forced op. | Value 2, time of day, weekday | 3 Bytes | CT | |
| 72 | Input f: Value/Forced op. | Value 2, forced operation | 2 Bit | CT | |
| 72 | Input f: Value/Forced op. | Value 2, scene number | 1 Byte | CT | |
| 72 | Input f: Value/Forced op. | Value 2, unsigned | 2 Bytes | CT | |
| 72 | Input f: Value/Forced op. | Value 2, signed | 4 Bytes | CT | |
| 72 | Input f: Value/Forced op. | Value 2, signed | 1 Byte | CT | |
| 72 | Input f: Blind Sensor | STOP/Slat adjustment | 1 Bit | CT | |
| 72 | Input f: Switch/Dim Sensor | Dimming | 4 Bit | CT | |
| 72 | Input f: Switch Sensor | Switch 2 | 1 Bit | CWT | |
| 73 | Input f: Blind Sensor | Upper limit position | 1 Bit | CW | |
| 73 | Input f: Switch Sensor | Switch 3 | 1 Bit | CWT | |
| 74 | Input f: Blind Sensor | Lower limit position | 1 Bit | CW | |
| 74 | Input f: Switch Sensor | Event 0/1 started | 1 Bit | CW | |
| 75 | Input g: Switch/Dim Sensor | Block | 1 Bit | CW | |
| 75 | Input g: Blind Sensor | Block | 1 Bit | CW | |
| 75 | Input g: sent Value | Block | 1 Bit | CW | |
| 75 | Input g: Switch Sensor | Block | 1 Bit | CW | |
| 76 | Input g: Switch/Dim Sensor | Switch | 1 Bit | CWT | |
| 76 | Input g: Blind Sensor | Shutter UP/DOWN | 1 Bit | CWT | |
| 76 | Input g: Value/Forced op. | Value 1, unsigned | 4 Bytes | CT | |
| 76 | Input g: Value/Forced op. | Value 1, unsigned | 2 Bytes | CT | |
| 76 | Input g: Value/Forced op. | Value 1, scene number | 1 Byte | CT | |
| 76 | Input g: Value/Forced op. | Value 1, signed | 1 Byte | CT | |
| 76 | Input g: Value/Forced op. | Value 1, unsigned | 1 Byte | CT | |
| 76 | Input g: Value/Forced op. | Value 1, floating point | 2 Bytes | CT | |
| 76 | Input g: Value/Forced op. | Value 1, forced operation | 2 Bit | CT | |
| 76 | Input g: Value/Forced op. | Value 1, signed | 4 Bytes | CT | |
| 76 | Input g: Value/Forced op. | Value 1 | 1 Bit | CT | |
| 76 | Input g: Value/Forced op. | Value 1, time of day, weekday | 3 Bytes | CT | |
| 76 | Input g: Value/Forced op. | Value 1, signed | 2 Bytes | CT | |
| 76 | Input g: Switch Sensor | Switch 1 | 1 Bit | CWT | |
| 77 | Input g: Switch/Dim Sensor | Dimming | 4 Bit | CT | |
| 77 | Input g: Blind Sensor | STOP/Slat adjustment | 1 Bit | CT | |
| 77 | Input g: Value/Forced op. | Value 2, signed | 1 Byte | CT | |
| 77 | Input g: Value/Forced op. | Value 2, signed | 4 Bytes | CT | |
| 77 | Input g: Value/Forced op. | Value 2, time of day, weekday | 3 Bytes | CT | |
| 77 | Input g: Value/Forced op. | Value 2 | 1 Bit | CT | |
| 77 | Input g: Value/Forced op. | Value 2, forced operation | 2 Bit | CT | |
| 77 | Input g: Value/Forced op. | Value 2, scene number | 1 Byte | CT | |
| 77 | Input g: Value/Forced op. | Value 2, unsigned | 2 Bytes | CT | |
| 77 | Input g: Value/Forced op. | Value 2, signed | 2 Bytes | CT | |
| 77 | Input g: Value/Forced op. | Value 2, unsigned | 4 Bytes | CT | |
| 77 | Input g: Value/Forced op. | Value 2, floating point | 2 Bytes | CT | |
| 77 | Input g: Value/Forced op. | Value 2, unsigned | 1 Byte | CT | |
| 77 | Input g: Switch Sensor | Switch 2 | 1 Bit | CWT | |
| 78 | Input g: Blind Sensor | Upper limit position | 1 Bit | CW | |
| 78 | Input g: switch sensor | Switch 3 | 1 Bit | CWT | |
| 79 | Input g: Blind Sensor | Lower limit position | 1 Bit | CW | |
| 79 | Input g: Switch Sensor | Event 0/1 started | 1 Bit | CW | |
| 80 | Input h: shutter sensor | Block | 1 Bit | CW | |
| 80 | Input h: sent Value | Block | 1 Bit | CW | |
| 80 | Input h: Switch/Dim Sensor | Block | 1 Bit | CW | |
| 80 | Input h: Switch Sensor | Block | 1 Bit | CW | |
| 81 | Input h: Blind Sensor | Shutter UP/DOWN | 1 Bit | CWT | |
| 81 | Input h: Value/Forced op. | Value 1, unsigned | 2 Bytes | CT | |
| 81 | Input h: Value/Forced op. | Value 1, floating point | 2 Bytes | CT | |
| 81 | Input h: Value/Forced op. | Value 1, forced operation | 2 Bit | CT | |
| 81 | Input h: Value/Forced op. | Value 1, signed | 4 Bytes | CT | |
| 81 | Input h: Value/Forced op. | Value 1, signed | 1 Byte | CT | |
| 81 | Input h: Value/Forced op. | Value 1, unsigned | 1 Byte | CT | |
| 81 | Input h: Value/Forced op. | Value 1, scene number | 1 Byte | CT | |
| 81 | Input h: Value/Forced op. | Value 1 | 1 Bit | CT | |
| 81 | Input h: Value/Forced op. | Value 1, time of day, weekday | 3 Bytes | CT | |
| 81 | Input h: Value/Forced op. | Value 1, signed | 2 Bytes | CT | |
| 81 | Input h: Value/Forced op. | Value 1, unsigned | 4 Bytes | CT | |
| 81 | Input h: Switch/Dim Sensor | Switch | 1 Bit | CWT | |
| 81 | Input h: Switch Sensor | Switch 1 | 1 Bit | CWT | |
| 82 | Input h: Blind Sensor | STOP/Slat adjustment | 1 Bit | CT | |
| 82 | Input h: Value/Forced op. | Value 2, unsigned | 2 Bytes | CT | |
| 82 | Input h: Value/Forced op. | Value 2, signed | 2 Bytes | CT | |
| 82 | Input h: Value/Forced op. | Value 2, unsigned | 4 Bytes | CT | |
| 82 | Input h: Value/Forced op. | Value 2, floating point | 2 Bytes | CT | |
| 82 | Input h: Value/Forced op. | Value 2, unsigned | 1 Byte | CT | |
| 82 | Input h: Value/Forced op. | Value 2, signed | 1 Byte | CT | |
| 82 | Input h: Value/Forced op. | Value 2, signed | 4 Bytes | CT | |
| 82 | Input h: Value/Forced op. | Value 2, time of day, weekday | 3 Bytes | CT | |
| 82 | Input h: Value/Forced op. | Value 2 | 1 Bit | CT | |
| 82 | Input h: Value/Forced op. | Value 2, forced operation | 2 Bit | CT | |
| 82 | Input h: Value/Forced op. | Value 2, scene number | 1 Byte | CT | |
| 82 | Input h: Switch/Dim Sensor | Dimming | 4 Bit | CT | |
| 82 | Input h: Switch Sensor | Switch 2 | 1 Bit | CWT | |
| 83 | Input h: Blind Sensor | Upper limit position | 1 Bit | CW | |
| 83 | Input h: Switch Sensor | Switch 3 | 1 Bit | CWT | |
| 84 | Input h: Blind Sensor | Lower limit position | 1 Bit | CW | |
| 84 | Input h: Switch Sensor | Event 0/1 started | 1 Bit | CW | |
| 85 | Output A | Switch | 1 Bit | CW | |
| 86 | Output A | Permanent ON | 1 Bit | CW | |
| 87 | Output A | Disable function Time | 1 Bit | CW | |
| 88 | Output A | Scene | 1 Byte | CW | |
| 89 | Output A | Forced operation | 2 Bit | CW | |
| 89 | Output A | Forced operation | 1 Bit | CW | |
| 90 | Output A | Status Switch | 1 Bit | CRT | |
| 91 | Output A | Logical connection 1 | 1 Bit | CW | |
| 92 | Output A | Logical connection 2 | 1 Bit | CW | |
| 93 | Output B | Switch | 1 Bit | CW | |
| 94 | Output B | Permanent ON | 1 Bit | CW | |
| 95 | Output B | Disable function Time | 1 Bit | CW | |
| 96 | Output B | Scene | 1 Byte | CW | |
| 97 | Output B | Forced operation | 2 Bit | CW | |
| 97 | Output B | Forced operation | 1 Bit | CW | |
| 98 | Output B | Status Switch | 1 Bit | CRT | |
| 99 | Output B | Logical connection 1 | 1 Bit | CW | |
| 100 | Output B | Logical connection 2 | 1 Bit | CW | |
| 101 | Output C | Switch | 1 Bit | CW | |
| 102 | Output C | Permanent ON | 1 Bit | CW | |
| 103 | Output C | Disable function Time | 1 Bit | CW | |
| 104 | Output C | Scene | 1 Byte | CW | |
| 105 | Output C | Forced operation | 2 Bit | CW | |
| 105 | Output C | Forced operation | 1 Bit | CW | |
| 106 | Output C | Status Switch | 1 Bit | CRT | |
| 107 | Output C | Logical connection 1 | 1 Bit | CW | |
| 108 | Output C | Logical connection 2 | 1 Bit | CW | |
| 109 | Object 253 | 1 Bit | CWT |
Parameters (351)
| Parameter | Type | Default |
|---|---|---|
| The device is ready for operation on delivery, see documentation! | list | <--- ATTENTION |
| The button "Standard" re-establishes the delivery status! | list | <--- NOTE |
| A not parameterized application can be dowloaded | list | <--- NOTE |
| Sending and switching delay after bus voltage recovery in s [2...255] | unsignedInt 2…255 | 2 |
| Rate of telegrams | list | not limited |
| Send communication object "in operation" | list | send value 0 cyclically |
| Sending cycle time in s [1...65,535] | unsignedInt 1…65535 | 60 |
| Enable communication object "Request status values" 1 bit | list | yes |
| recall with object value | list | 1 |
| Input a (binary input, contact scanning) | list | Switch Sensor/Fault monitoring input |
| Designation (40 characters) | text | Notsignal/Emergency |
| Enable internal blocking | list | no |
| Input b (binary input, contact scanning) | list | Switch Sensor/Fault monitoring input |
| Designation (40 characters) | text | Wassersensor/Water detector |
| Input c (binary input, contact scanning) | list | Switch Sensor/Fault monitoring input |
| Designation (40 characters) | text | Lüfter Badezimmer/Blower bathroom |
| Enable internal blocking | list | yes |
| Input d (binary input, contact scanning) | list | Switch Sensor/Fault monitoring input |
| Designation (40 characters) | text | Nicht stören/Do not disturb |
| Input e (binary input, contact scanning) | list | Switch Sensor/Fault monitoring input |
| Designation (40 characters) | text | Türkontakt/Door contact |
| Input f (binary input, contact scanning) | list | Switch Sensor/Fault monitoring input |
| Designation (40 characters) | text | Keycard/Keycard |
| Input g (binary input, contact scanning) | list | Value/Forced operation |
| Designation (40 characters) | text | Fensterkontakt/Window contact |
| Input h (binary input, contact scanning) | list | Switch Sensor/Fault monitoring input |
| Designation (40 characters) | text | Kondenswasser/Drip tray |
| Enable communication object "Disable" 1 bit | list | no |
| Enable communication object "Event 0/1 started" 1 bit | list | yes |
| Debounce time | list | 50 ms |
| Distinction between short and long operation | list | no |
| Opening the contacts => Event 0 Closing the contacts => Event 1 | list | <--- NOTE |
| Short operation => Event 0 Long operation => Event 1 | list | <--- NOTE |
| Connected contact type | list | close |
| Input is on operation | list | close |
| Activate minimum signal time | list | no |
| Long operation after ... | list | 0.6 s |
| Intern verbinden mit Jalousieausgang | list | no |
| On closing the contact in value x 0.1 s [0...65,535] | unsignedInt 0…65535 | 10 |
| for rising edge in value x 0.1 s [0...65,535] | unsignedInt 0…65535 | 10 |
| On opening the contact in value x 0.1 s [0...65,535] | unsignedInt 0…65535 | 10 |
| for falling edge in value x 0.1 s [0...65,535] | unsignedInt 0…65535 | 10 |
| Scan input after download, ETS reset and bus voltage recovery | list | no |
| Inactive wait state after bus voltage recovery in s [0...30,000] | unsignedInt 0…30000 | 0 |
| Inactive wait state after bus voltage recovery in s [0...30,000] | unsignedInt 0…30000 | 0 |
| Communication object "Switch 1" (cyclic sending possible) | list | yes |
| Function Dimming | list | Dimming and switching |
| Operating functionality of the Blind | list | 2 push buttons op. (short = Stepwise, long = Move) |
| Reaction with event 0 | list | ON |
| Reaction with event 1 | list | ON |
| Short operation: Move UP/DOWN Long operation: STOP/Stepwise | list | <-- NOTE |
| On operation: Slat | list | <-- NOTE |
| On operation: Move UP/DOWN end of operation STOP | list | <-- NOTE |
| Short operation: STOP/Stepwise Long operation: Move UP/DOWN | list | <-- NOTE |
| On operation in succession UP, STOP, DOWN, STOP | list | <-- NOTE |
| Internal connection | list | Room Scenario 3/4 |
| Cyclic sending | list | no |
| Erkennung langer Tastendruck: | list | Standard (only debouncing) |
| Telegram repeated every ... in s [1...65,535] | unsignedInt 1…65535 | 60 |
| on object value | list | 0 or 1 |
| Communication object "Switch 2" | list | no |
| Reaction on long operation NONE | list | no reaction |
| On short operation: switch | list | no reaction |
| Value 1 (rising edge/short operation) | list | 1 byte value [0...255] |
| Reaktion bei Betätigung | list | Moving TOGGLE |
| Reaction on operation | list | STOP/Slat UP |
| Reaction on operation | list | Move UP |
| Reaktion bei Tastendruck | list | Moving TOGGLE |
| Reaction on short operation | list | STOP/Slat UP |
| Reaction with event 0 | list | OFF |
| Internal connection | list | no |
| Communication object "Switch 3" | list | no |
| On operation: dimming direction | list | alternating, DARKER after switching ON |
| On long operation: dimming direction | list | alternating, DARKER after switching ON |
| sent value [0...65,535] | signedInt 0…65535 | 0 |
| sent value | list | 20.00 |
| sent value | list | Disable forced operation |
| sent value [-2,147,483,648...2,147,483,647] | signedInt -2147483648…2147483647 | 0 |
| sent value [-128...127] | signedInt -128…127 | 0 |
| sent value [0...255] | signedInt 0…255 | 0 |
| 8 bit scene | unsignedInt 1…64 | 1 |
| sent value | list | ON |
| Hour [0...23] | unsignedInt 0…23 | 0 |
| sent value [-32,768...32,767] | signedInt -32768…32767 | 0 |
| sent value [0...4,294,967,295] | unsignedInt 0…4294967295 | 0 |
| Reaktion bei Loslassen | list | Lamella dir. reverse to moving (cycl.) |
| Reaction on long operation | list | Move UP |
| Store/Call scene | list | call |
| Minute [0...59] | unsignedInt 0…59 | 0 |
| Seconds [0...59] | unsignedInt 0…59 | 0 |
| Weekday | list | 0 = no day |
| Value 2 (falling edge/long operation) | list | 1 byte value [0...255] |
| Dimming mode | list | START/STOP dimming |
| sent value | list | OFF |
| Telegram "Slat" is repeated every | list | 0.6 s |
| zum Auffüllen | unsignedInt 0…255 | 0 |
| Brightness change on every sent telegram | list | 100% |
| Sending cycle time: Telegram is repeated every ... | list | 0.6 s |
| sent value [0/1] | list | ON |
| Reaktion bei Loslassen | list | STOP |
| sent value [0/1] | list | OFF |
| Telegram "Lamella" is repeated every | list | 0.5 s |
| Sending cycle time: Telegram is repeated every ... | list | 0.5 s |
| Reaction with event 1 | list | no reaction |
| Internal connection | list | Output C (16A/10AX) |
| Telegram "Lamella" is repeated every | list | 0.6 s |
| Communication object "Switch 1" (cyclic sending possible) | list | yes |
| Reaction with event 1 | list | OFF |
| Erkennung langer Tastendruck: | list | Distinction of long/short push button |
| Reaktion bei Tastendruck | list | Moving TOGGLE (via STOP) |
| Reaktion bei Betätigung | list | Moving TOGGLE (via STOP) |
| Reaktion bei Loslassen | list | no reaction |
| Inactive wait state after bus voltage recovery in s [0...30,000] | unsignedInt 0…30000 | 0 |
| Internal connection | list | Room Scenario 5/6 |
| Scan input after download, ETS reset and bus voltage recovery | list | yes |
| Reaction with event 0 | list | TOGGLE |
| sent value [0...255] | signedInt 0…255 | 4 |
| Reaktion bei Tastendruck | list | Lamella direction reverse to moving |
| Reaktion bei Betätigung | list | Lamella direction reverse to moving |
| Output A (20 A/16 AX C-Load) | list | enable |
| Designation (40 characters) | text | Steckdosen/Power outlets (sockets) |
| Output B (16 A/10 AX) | list | enable |
| Designation (40 characters) | text | Licht/Light |
| Output C (16 A/10 AX) | list | enable |
| Output D, E, F (6 A) | list | enable as fan speeds |
| Output D (6 A) | list | disabled |
| DUMMY | list | 0 |
| Output E (6 A) | list | disabled |
| Output F (6 A) | list | disabled |
| Designation (40 characters) | text | - - - TEXT - - - |
| Reglereingang | list | enable |
| Ventil HEIZEN | list | enable |
| Ventil KÜHLEN | list | enable |
| Reaction of output | list | normally open contact |
| Contact position on bus voltage failure | list | unchanged |
| Object value "Switch" on bus voltage recovery | list | not write |
| Enable function Time | list | no |
| Value object "Disable function Time" on bus voltage recovery | list | 1, i.e. Disable function Time |
| Enable function Scene | list | yes |
| Enable function Logic | list | no |
| Enable function Forced operation | list | no |
| Type of object "Forced operation" | list | 1 bit |
| Contact position on Forced operation | list | OFF |
| Contact position with end of the Forced operation | list | calculate present contact position |
| Enable communication object "Status Switch" 1 bit | list | yes |
| Send object value | list | after a change |
| Object value of contact position | list | 1 = closed, 0 = open |
| Function Time | list | Staircase lighting |
| Staircase lighting time in s [1...65,535] | unsignedInt 1…65535 | 30 |
| Switching ON delay in s [0...65,535] | unsignedInt 0…65535 | 5 |
| Switching OFF delay in s [0...65,535] | unsignedInt 0…65535 | 5 |
| Extending Staircase lighting by multiple operation ("Pumping up") | list | yes (retriggerable) |
| Staircase lighting can be switched | list | ON with 1 and OFF with 0 |
| Restart of Staircase lighting after end of permanent ON | list | no |
| Switching delays retriggerable | list | no |
| Value object "Disable function Time" on bus voltage recovery | list | 1, i.e. Disable function Time |
| Dauer-EIN aktivieren | list | yes |
| Set standard value after the download or ETS reset | list | yes |
| Assignment to scene number (no. 1...64, 0 = no assignment) | unsignedInt 0…64 | 1 |
| Standard value | list | ON |
| Assignment to scene number (no. 1...64, 0 = no assignment) | unsignedInt 0…64 | 2 |
| Standard value | list | OFF |
| Assignment to scene number (no. 1...64, 0 = no assignment) | unsignedInt 0…64 | 3 |
| Assignment to scene number (no. 1...64, 0 = no assignment) | unsignedInt 0…64 | 5 |
| Assignment to scene number (no. 1...64, 0 = no assignment) | unsignedInt 0…64 | 15 |
| Assignment to scene number (no. 1...64, 0 = no assignment) | unsignedInt 0…64 | 6 |
| Assignment to scene number (no. 1...64, 0 = no assignment) | unsignedInt 0…64 | 0 |
| Logical connection 1 active | list | no |
| Function of Logical connection | list | AND |
| Result is inverted | list | no |
| Object value "Logical connection 1" after bus voltage recovery | list | not write |
| Gate disabled, if object value "Logical connection 1" is | list | 0 |
| Logical connection 2 active | list | no |
| Object value "Logical connection 2" after bus voltage recovery | list | not write |
| Gate disabled, if object value "Logical connection 2" is | list | 0 |
| Assignment to scene number (no. 1...64, 0 = no assignment) | unsignedInt 0…64 | 4 |
| Enable function Time | list | yes |
| Staircase lighting time in s [1...65,535] | unsignedInt 1…65535 | 300 |
| Extending Staircase lighting by multiple operation ("Pumping up") | list | no (not retriggerable) |
| Value object "Disable function time" on bus voltage recovery | list | 1, i.e. Disable function Time |
| Fan type | list | multi-level |
| "einstufig" DUMMY | list | 0 |
| "mehrstufig = 3" DUMMY | list | 0 |
| Enable function Scene | list | no |
| Standardbegrenzung für 1-stufig DUMMY | list | 1, OFF |
| Fan speeds on 2 limit | list | no |
| Fan operation Mode DUMMY | list | Step switch |
| Fan operation Mode (See techn. data of the fan!) | list | Step switch |
| Delay between fan speed switching in ms [50...5,000] | unsignedInt 50…5000 | 500 |
| Fan speed on bus voltage failure | list | unchanged |
| Fan speed on bus voltage recovery | list | unchanged |
| Enable communication object "Forced operation" 1 bit | list | no |
| Forced operation on object value | list | 1 |
| Behaviour with forced operation | list | ON |
| Limitation on forced operation | list | unchanged |
| Observe contact live and switching number per minutes | list | <--- NOTE |
| Flashing if communication object "Switching" is | list | ON (1) or OFF (0) |
| Duration for ON in value x 0.1 s [5...65,535] | unsignedInt 5…65535 | 10 |
| Duration for OFF in value x 0.1 s [5...65,535] | unsignedInt 5…65535 | 10 |
| Enable automatic operation | list | no |
| Number of impulses [1...100] | unsignedInt 1…100 | 5 |
| Contact position after Flashing | list | calculate present contact position |
| Function time on ON | list | none |
| Enable direct operation | list | no |
| Time in s [1...65,535] | unsignedInt 1…65535 | 20 |
| Time in s [1...65,535 x 0.1] | unsignedInt 1…65535 | 20 |
| Function time on OFF | list | none |
| Starting characteristic of fan | list | no |
| Switch on over fan speed | list | 3 |
| Minimum dwell period in switch on in s [1...65,535] | unsignedInt 1…65535 | 20 |
| Enable communication object "Status fan speed x" 1 bit | list | no |
| Meaning | list | current fan speed |
| Send object values | list | after a change |
| Enable communication object "Status fan speed" 1 byte | list | no |
| Enable communication object "Status byte mode" 1 byte | list | no |
| Enable communication object "Status fan ON/OFF" 1 bit | list | no |
| Enable communication object "Status automatic" 1 bit | list | no |
| Objekt "Automatik EIN/AUS" freigeben DUMMY | list | yes |
| Object value "automatic ON/OFF" switch on to the automatic | list | 1 |
| Threshold value OFF <-> speed 1 in % [1...100] | unsignedInt 1…100 | 10 |
| Threshold value speed 1 <-> speed 2 in % [1...100] | unsignedInt 1…100 | 100 |
| Threshold value OFF <-> ON in % [1...100] | unsignedInt 1…100 | 10 |
| Threshold value speed 2 <-> speed 3 in % [1...100] | unsignedInt 1…100 | 100 |
| Contact position with end of the Forced operation | list | calculate present contact position |
| Hysteresis threshold value in % +/- [0...20 % | unsignedInt 0…20 | 5 |
| Minimum dwell period in fan speed in s [0...65,535] | unsignedInt 0…65535 | 0 |
| Flashing if communication object "Switching" is | list | ON (1) or OFF (0) |
| Enable limitations | list | no |
| Fan with limitation 1 | list | inactive |
| Fan speed with limitation 1 | list | 3, 2, 1, OFF |
| Fan with limitation 2 | list | unchanged |
| Fan speed with limitation 2 | list | unchanged |
| Fan with limitation 3 | list | inactive |
| Fan speed with limitation 3 | list | 3, 2, 1, OFF |
| Fan with limitation 4 | list | unchanged |
| Fan speed with limitation 4 | list | unchanged |
| Enable communication object "Switch speed x" 1 bit | list | yes |
| Enable communication object "Fan speed UP/DOWN" 1 bit | list | no |
| Enable communication object "Fan speed switch" 1 byte | list | no |
| Value object "Disable function Time" on bus voltage recovery | list | 0, i.e. Enable function Time |
| HVAC System | list | 1 Control value/2-pipe |
| Toggle via separately object | list | <--- NOTE |
| Valve COOLING independently usable | list | <--- NOTE |
| Toggle via automatically Valve COOLING not usable | list | <--- NOTE |
| Toggle via separately object Valve COOLING not usable | list | <--- NOTE |
| Toggle via automatically | list | <--- NOTE |
| Dummy: Reaktion auf Stellgr. C | list | (H) 1S/4R obj |
| Dummy: Reaktion auf Stellgr. H | list | (C) 1S/4R obj |
| Operation HEATING/COOLING after bus voltage recovery | list | unchanged |
| Object value for HEATING the object "Toggle HEATING/COOLING" | list | 1 |
| Monitoring control values e.g. thermostat | list | no |
| Monitoring time in s [30...65,535] | unsignedInt 30…65535 | 120 |
| Send object value (Object "Control value fault" 1 bit) | list | after a change |
| Objektwert bei Störung | list | 1 |
| Control value after control fault in % [0...100] | unsignedInt 0…100 | 30 |
| Valve control | list | 3 point, opening and closing |
| Valve type | list | de-energised closed |
| Observe reversing time | list | 300 ms |
| Valve position on bus voltage failure | list | close |
| Valve position on bus voltage failure | list | open |
| Valve position on bus voltage failure in % [0...100] | list | unchanged |
| Valve position after bus voltage recovery | list | unchanged |
| Valve position in % [0...100] | unsignedInt 0…100 | 0 |
| Ventilstellung nach Busspannungs- wiederkehr in % [0...100] | unsignedInt 1…255 | 255 |
| Cycle time of the PWM in s [10...6,000] | unsignedInt 10…6000 | 180 |
| Valve control duration from 0...100 % in s [10...6,000] | unsignedInt 10…6000 | 180 |
| Valve control duration from 100...0 % in s [10...6,000] | unsignedInt 10…6000 | 180 |
| Correct valve characteristic curve | list | no |
| Automatically adjust valve position | list | no |
| Number of valve controls up to adjustment [1...65,535] | unsignedInt 1…65535 | 100 |
| Disable on object value | list | 1 |
| Enable communication object "Forced operation" 1 bit | list | no |
| Valve position on forced operation in % [0...100] | unsignedInt 0…100 | 30 |
| Enable communication object "Valve position status" | list | no |
| Object value with valve position > 0 | list | 1 |
| Enable valve purge | list | no |
| Enable communication object "Status valve purge" 1 bit | list | no |
| Duration of valve purge in min. [1...255] | unsignedInt 1…255 | 10 |
| Automatic valve purge | list | no |
| Purge cycle in weeks [1...12] | unsignedInt 1…12 | 6 |
| Reset purge cycle from control value in % [1...99] | unsignedInt 1…99 | 99 |
| Value pair 1 Control value in % [0...100] | unsignedInt 0…100 | 0 |
| Value pair 2 Control value in % [0...100] | unsignedInt 0…100 | 100 |
| Valve position in % [0...100] | unsignedInt 0…100 | 100 |
| Further value pair | list | no |
| Value pair 3 Control value in % [0...100] | unsignedInt 0…100 | 50 |
| Valve position in % [0...100] | unsignedInt 0…100 | 50 |
| Value pair 4 Control value in % [0...100] | unsignedInt 0…100 | 50 |
| Value pair 3 Control value in % [0…...100] | unsignedInt 0…100 | 50 |
| Room Scenario enable | list | yes |
| Room Scenario 1 and 2 | list | enable |
| Room condition 1 and 2 | list | disabled |
| Designation Room Scenario 1 (40 characters) | text | Check In Willkommenszene/Welcome scene |
| Designation Room Scenario 2 (40 characters) | text | Check Out Service Raum/Service room |
| Room Scenario 3 and 4 | list | enable |
| Room condition 1 and 2 | list | enable |
| Designation Room Scenario 3 (40 characters) | text | Standby Raum frei/Room free |
| Designation Room Scenario 4 (40 characters) | text | Notsignal/Emergency |
| Room Scenario 5 and 6 | list | enable |
| Designation Room Scenario 5 (40 characters) | text | Keycard entfernen/remove |
| Designation Room Scenario 6 (40 characters) | text | Keycard einführen/move |
| Room Scenario 7 and 8 | list | disabled |
| Designation Room Scenario 7 (40 characters) | text | Frei/Free |
| Designation Room Scenario 8 (40 characters) | text | Frei/Free |
| Room Scenario 9 and 10 | list | disabled |
| Designation Room Scenario 9 (40 characters) | text | Frei/Free |
| Designation Room Scenario 10 (40 characters) | text | Frei/Free |
| Recall on object value = 0 (object "Room Scenario 1...10 recall") | list | <--- NOTE |
| On bus voltage recovery recall Room Scenario | list | no |
| Event 1 started immediately | list | yes |
| Scene recall | list | only device internal |
| Scene number [1...64] | unsignedInt 1…64 | 1 |
| Switch 1 send | list | no |
| Switch 2 send | list | no |
| ON/OFF send to thermostat | list | ON |
| 1 byte value send | list | no |
| send value | unsignedInt 0…255 | 0 |
| Automatic Blind output enable | list | no |
| Internal blocking the inputs | list | active |
| Event 2 started with a delay | list | no |
| Delay time in s [0...65,535] | unsignedInt 0…65535 | 30 |
| Scene recall | list | no |
| ON/OFF send to thermostat | list | no |
| Internal blocking the inputs | list | unchanged |
| Recall on object value = 1 (object "Room Scenario 1...10 recall") | list | <--- NOTE |
| Scene number [1...64] | unsignedInt 1…64 | 2 |
| Recall on object value = 2 (object "Room Scenario 1...10 recall") | list | <--- NOTE |
| Scene number [1...64] | unsignedInt 1…64 | 3 |
| ON/OFF send to thermostat | list | OFF |
| Recall on object value = 3 (object "Room Scenario 1...10 recall") | list | <--- NOTE |
| Scene recall | list | device internal and via the bus |
| Scene number [1...64] | unsignedInt 1…64 | 4 |
| Switch 1 send | list | ON |
| Recall on object value = 4 (object "Room Scenario 1...10 recall") | list | <--- NOTE |
| Scene number [1...64] | unsignedInt 1…64 | 5 |
| Switch 2 send | list | OFF |
| Event 2 started with a delay | list | yes |
| Delay time in s [0...65,535] | unsignedInt 0…65535 | 120 |
| Scene number [1...64] | unsignedInt 1…64 | 15 |
| Recall on object value = 5 (object "Room Scenario 1...10 recall") | list | <--- NOTE |
| Scene number [1...64] | unsignedInt 1…64 | 6 |
| Switch 2 send | list | ON |
| Internal blocking the inputs | list | deactivate |
| Recall on object value = 6 (object "Room Scenario 1...10 recall") | list | <--- NOTE |
| Scene number [1...64] | unsignedInt 1…64 | 7 |
| Recall on object value = 7 (object "Room Scenario 1...10 recall") | list | <--- NOTE |
| Scene number [1...64] | unsignedInt 1…64 | 8 |
| Recall on object value = 8 (object "Room Scenario 1...10 recall") | list | <--- NOTE |
| Event 1 started immediately | list | no |
| Recall on object value = 9 (object "Room Scenario 1...10 recall") | list | <--- NOTE |
| english | list | no |
Version history
| Application | App no | Fingerprint | First seen | Size | File |
|---|---|---|---|---|---|
| Room Master Basic/2.6a 2.6 latest | $A053 | A2A4 | 2026-11-25 | 410 KB | Download |
About this file
This is the official ETS product database for the ABB AG - STOTZ-KONTAKT RM/S1.1 Room Master,Basic,MDRC (2CDG 110 094 R0011), published by the manufacturer in the KNX online catalog. To use it, open ETS, go to Catalogs → Import and choose the downloaded .knxprod file. The device then appears in your catalog and can be added to a project. Older versions are kept so existing projects can be matched to the application program they were commissioned with.
More from ABB AG - STOTZ-KONTAKT
- RM/S2.1 Room Master,Premium,MDRC 2CDG 110 095 R0011
- RC/A4.2 Room Controller,4 Modules,SM 2CDG 110 104 R0011
- RC/A8.2 Room Controller,8 Modules,SM 2CDG 110 106 R0011
- RM/S3.1 Room Master,MDRC 2CDG 110 165 R0011
- RM/S4.1 Room Master,MDRC 2CDG 110 170 R0011
- PS5604-KNX AC500 1SAP 195 800 R0101
- EG/A32.2.1 KNX/EnOcean Gateway 2 CDG 120 047 R0011
- Sidus KNX Tastsensor 1-/2-fach, UP 2CCA 380 319 R0001
- Sidus KNX control element 2/4gang, flush-mounted 2CCA 380 339 R0001
- Sidus KNX Tastsensor 4-/8-fach, UP 2CCA 380 375 R0001
- Sidus KNX Movement detector 180° flat 2CCA 388 975 R0001
- Sidus KNX Room temperature controller, FM 2CCA388429R0001