ABB AG - BUSCH-JAEGER 6197/70 6197/70 Light Controller, 2fold, 1-10V, 16A, MDRC

6197/70 Light Controller, 2fold, 1-10V, 16A, MDRC 6197/70

ABB AG - BUSCH-JAEGER · Order number 6197/70 · Lighting Control › 1-10V Switch / Dim Actuators and Light Controllers

Download .knxprod Control Dim 2f 1-10V/1.2a 1.2 · 218 KB

Product

ManufacturerABB AG - BUSCH-JAEGER
Product name6197/70 Light Controller, 2fold, 1-10V, 16A, MDRC
Order number6197/70
Product textLight Controller, 2fold, 1-10V, 16A, MDRC
HardwareLR/S2.16.1
MediumTwisted Pair
Bus current (mA)12
Rail mountedYes
Width (mm)72
RegistrationRegistered · 2012-01-11
Languagesde-DE, en-US, fr-FR
Catalog entryM-0007_H-2CDG.20110.20087R0011-2-O0002_HP-A049-12-BCE4-O0002_CI-6197.2F70-1
FingerprintBCE4
SHA-2565f3b35400971e422b1fa06179e5bfddad0acda3ca370f9c221064fb278aeface
First seen2026-11-25
MarketsAustria, Belgium, Germany, Netherlands

Application program: Control Dim 2f 1-10V/1.2a 1.2

Application number$A049
Version1.2
Mask versionMV-0701 (7.1)
KNX Data SecureNo
Parameters528
Group objects84
Group objects (84)
NoNameFunctionSizeDPTFlags
0GeneralIn Operation1 Bit1.2 booleanCRT
1GeneralExcess temperature1 BitCRT
2GeneralCritical excess temperature1 BitCRT
3GeneralStatus function1 ByteCRT
4Dummy 04Dummy1 BitCT
5Dummy 05Dummy1 BitCT
6Dummy 06Dummy1 BitCT
7Dummy 07Dummy1 BitCT
8Dummy 08Dummy1 BitCT
9Dummy 09Dummy1 BitCT
10Output ASwitch1 Bit1.1 switchCWT
10Output ASwitch/Status1 Bit1.1 switchCRWT
10Output ASwitch1 Bit1.1 switchCW
11Output AStatus switch1 Bit1.1 switchCRT
12Output ARelative dimming4 Bit3.7 dimming controlCW
13Output ABrightness value1 Byte5.1 percentage (0..100%)CWT
13Output ABrightness value/Status1 Byte5.1 percentage (0..100%)CRWT
14Output AStatus brightness value1 Byte5.1 percentage (0..100%)CRT
15Output ADimming speed 0...100 %2 BytesCRWU
16Output AForced operation2 Bit2.1 switch controlCW
16Output AForced operation1 Bit1.3 enableCW
17Output ACall preset 1 and 21 BitCW
18Output ASet preset 1 and 21 BitCW
19Output ACall preset 3 and 41 BitCW
20Output ASet preset 3 and 41 BitCW
21Output A8 bit scene1 ByteCW
22Output ARestore standard scene1 BitDPT.1CW
22Output ARestore standard scene1 BitCW
23Output ABlock1 Bit1.3 enableCW
24Output Aactivate control1 Bit1.3 enableCRW
24Output AActivate staircase function1 Bit1.3 enableCW
24Output AActivate slave mode1 Bit1.3 enableCW
25Output APermanent ON1 Bit1.1 switchCW
25Output ABrightness value of slave1 Byte5.1 percentage (0..100%)CWT
25Output AEnable calibration1 Bit1.3 enableCRWT
26Output ADuration of staircase lighting2 BytesCRW
26Output ACalibration lighting1 Bit1.3 enableCRW
27Output AWarning staircase lighting1 BitCT
27Output ACalibration daylight1 Bit1.3 enableCRW
28Output AMaster: Slave brightness value1 Byte5.1 percentage (0..100%)CRT
29Output ASetpoint1 Byte5.1 percentage (0..100%)CRW
30Output AActual value1 Byte5.1 percentage (0..100%)CRW
30Output ADummy1 BitCT
31Output ADummy1 BitCT
32Output ASensor value1 Byte5.1 percentage (0..100%)CR
33Output AError signal1 Bit
34Output AStatus byte1 ByteCRT
35Output BSwitch1 Bit1.1 switchCWT
35Output BSwitch/Status1 Bit1.1 switchCRWT
36Output BStatus switch1 Bit1.1 switchCRT
37Output BRelative dimming4 Bit3.7 dimming controlCW
38Output BBrightness value/Status1 Byte5.1 percentage (0..100%)CRWT
38Output BBrightness value1 Byte5.1 percentage (0..100%)CWT
39Output BStatus brightness value1 Byte5.1 percentage (0..100%)CRT
40Output BDimming speed 0...100 %2 BytesCRWU
41Output BForced operation2 Bit2.1 switch controlCW
41Output BForced operation1 Bit1.3 enableCW
42Output BCall preset 1 and 21 BitCW
43Output BSet preset 1 and 21 BitCW
44Output BCall preset 3 and 41 BitCW
45Output BSet preset 3 and 41 BitCW
46Output B8 bit scene1 ByteCW
47Output BRestore standard scene1 BitCW
48Output BBlock1 Bit1.3 enableCW
49Output BActivate staircase function1 Bit1.3 enableCW
49Output BActivate slave mode1 Bit1.3 enableCW
49Output Bactivate control1 Bit1.3 enableCRW
50Output BPermanent ON1 Bit1.1 switchCW
50Output BBrightness value of slave1 Byte5.1 percentage (0..100%)CWT
50Output BEnable calibration1 Bit1.3 enableCRWT
51Output BDuration of staircase lighting2 BytesCRW
51Output BCalibration lighting1 Bit1.3 enableCRW
52Output BWarning staircase lighting1 BitCT
52Output BCalibration daylight1 Bit1.3 enableCRW
53Output BDummy1 BitCT
53Output BMaster: Slave brightness value1 Byte5.1 percentage (0..100%)CRT
54Output BDummy1 BitCT
54Output BSetpoint1 Byte5.1 percentage (0..100%)CRW
55Output BDummy1 BitCT
55Output BActual value1 Byte5.1 percentage (0..100%)CRW
56Output BDummy1 BitCT
57Output BSensor value1 Byte5.1 percentage (0..100%)CR
58Output BError signal1 Bit
59Output BStatus byte1 ByteCRT
Parameters (143)
ParameterTypeDefault
Parameter settingslistchannel setting global (together)
Sending and switching delay after bus voltage recovery in s [2...255]unsignedInt 2…2552
During sending and switching delay outputs are unchangedlist<--- NOTE
Send object "in operation"listno
Sending cycle time in s [1...65,535]unsignedInt 1…6553560
send 0unsignedInt 0…2550
send ONEunsignedInt 0…2550
Limit number of telegramslistno
Max. number of sent telegramsunsignedInt 0…2552
Max. number of sent telegramsunsignedInt 1…25520
In Periodlist10 s
Period of observationsignedInt -32768…327671
Sending rate to 1...10V outputslist1800 Kbit
Light sensorunsignedInt 0…2550
Free light sensor setting to the outputslistno
Actual value (Control input)listlower sensor value
lowerlistupper sensor value
lowerlistlower sensor value
no calculationunsignedInt 0…2550
Light sensor A is allocated tolistOutput A
Light sensor B is allocated tolistOutput B
Output A: Sensitivity of allocated light sensorlistnormal
Output B: Sensitivity of allocated light sensorlistnormal
Please only use plausible settingslist<--- NOTE
ETS do not check plausibility!list<--- NOTE
ramp for manual useunsignedInt 0…25515
Select additional functionlistLight control
Status response of switching statelistno
Sendlistonly after changing
invertedlistno, 0 = OFF, 1 = ON
Status response of brightness valuelistno
Disable time after sending object "Status brightness value" in s [0..10]unsignedInt 0…100
Disable time after sending object "Brightness value" in s [0..10]unsignedInt 0…100
State of switching on supply voltage failurelistContact unchanged
Value of object "Switch" on bus voltage recoverylistrestore status before failure
Enable function "1 bit Preset"listno
Restore presets with standard value during downloadlistyes
Enable function "8 bit scene"listno
Restore scene values with standard valueslistvia download
Object "Restore standard scene" must be assigned to a group addresslist<--- NOTE
Enable function "forced operation"listno
Brightness while object value = 3 (forced operation = active, ON)list100 % (255)
Brightness while object value = 1 (forced operation = active, ON)list100 % (255)
Setting force operation after bus voltage recoverylistinactive (value 0)
Setting force operation after bus voltage recoverylistinactive
Enable function "Blocking"listno
Enable characteristic adjustmentlistno
Sensorwert zyklisch senden in s 0 = nicht senden";"Sensorwert zyklisch senden iunsignedInt 0…2550
Sensowert zyklisch senden in s 0 = nicht senden";"Sensowert zyklisch senden inunsignedInt 0…2550
Switch ON vialist100 % (255)
while switching off (0 = immediately)unsignedInt 0…655350
while switching on (0 = immediately)unsignedInt 0…655350
Dimming speed 0...100 % in s [0...65,535]unsignedInt 0…655356
Maximum dimming valuelist100 % (255)
Minimum dimming valuelist20 % (51)
Dimming value apply to Switch, Dimming and staircase lighting functionlist<--- NOTE
Allow switching on via relative dimminglistyes
Allow switching off via rel. dimminglistyes
Dim period changeable via object (Object: Dimming speed 0...100 %)listno
Time for passing from 0...100 % while setting brightness, in s [0...65,535]unsignedInt 0…655350
Maximum brightness valuelist100 % (255)
Minimum brightness valuelist20 % (51)
Brightness values apply to set brightness slave-, preset and scene functionlist<--- NOTE
Allow switching on via brightness valueslistyes
Allow switching off via brightness valuelistyes
Reaction on preset 1 (telegr. value 0)list0 % (switch off)
Reaction on preset 2 (telegr. value 1)list100 % (255)
Time to set new brightness value "Transition time" in s [0...65,535]unsignedInt 0…655350
Preset 1 and 2 can be set via the buslistno
Reaction on preset 3 (telegr. value 0)list0 % (switch off)
Reaction on preset 4 (telegr. value 1)list50 % (128)
Preset 3 and 4 can be set via the buslistno
Assignment to scene number 1...64listno assignment
Standard brightness valuelist100 % (255)
Time to set new brightness value "Transition time" in s [0...65,535]unsignedInt 0…655353
Enable more scene assignmentslistno
Scenelistnot used
Enable more scene Assignmentslistno
Number of value pairsunsignedInt 0…2550
Number of value pairslist2
X0 lower sensor value (input)unsignedInt 1…2551
Y0 Adjusted brightness value (output)unsignedInt 1…2551
X1 upper sensor value (input)unsignedInt 2…255255
X1 average sensor value (input) [2...254]unsignedInt 2…254127
X1 average sensor value (input) [2...127]unsignedInt 2…12785
Y1 Adjusted brightness value (output)unsignedInt 1…255127
X2 upper sensor value (input)unsignedInt 1…255255
X2 average sensor value (input) [128...254]unsignedInt 128…254180
Y2 Adjusted brightness value (output)unsignedInt 1…255255
X3 upper sensor value (input)unsignedInt 1…255255
Y3 Adjusted brightness value (output)unsignedInt 1…255255
dummylistyes
Brightness value after switching onlist100 % (255)
Upper dimming limit for relative dimmingunsignedInt 0…255255
Time duration in sec [0...65,535]unsignedInt 0…65535180
After staircase time dimming to basis brightnesslist0 % (off)
dummyunsignedInt 1…2551
Time for dimming down in s [0...65,535]unsignedInt 0…6553560
Switching onlistno reaction
Extending staircase lighting by multiple operation ("pumping up")listyes (retriggerable)
Light controller controls as "master" other dimmer actuatorslistno
Reaction on switching off via object "switch"listno reaction
Relative dimminglistSlave mode can be deactivated
Changing brightness during lighting controllistmedium
Changing brightness during lighting controllistfast
Brightness value during permanent ONlist100 % (255)
Brightness value or preset or scene recalllistno reaction
Upper control limit during active lighting controllist100 % (255)
Restart of staircase time after end of permanent ONlistyes
Slave mode after bus voltage recoverylistactive
Lower control limit during lighting controllist20 % (51)
Warning during dimming down (object "Warning stairc. lighting")listyes
Slave is controlled vialistExternal via object
Allow switching on/off during lighting controllistno, illumination is always on
max. lower threshold for switching on/off-> adjust parameterlist10 % (26) Attention: illuminated charact.
Switch off if control deviation is greater than [0...30]unsignedInt 0…305
Channel B is masterlistno
Channel B is masterlistyes
no masterlistno
Channel A is no masterlistno
masterlistno
Compensation factor for daylight calibration automaticallylistyes
Factor for daylight compensation in % [0...99]unsignedInt 0…9935
Restore factor for daylight compensation during Downloadlistyes
Adjustable control dynamicslistno
Step time for slow approachlist2 s
Control deviation for medium dimming speedunsignedInt 0…5020
Maximum brightness change per control stepunsignedInt 1…101
Control deviation for high increments (max. control step)unsignedInt 10…25530
Control deviation for high incrementsunsignedInt 0…301
Step time for slow approachlist0.1 s
Attention: These parameters have effect on the lighting control function.list<--- NOTE
Maximum brightness changeunsignedInt 1…101
Control deviation for high increments (max. control step)unsignedInt 10…25530
relative dimminglistno reaction
Brightness value or Scene-/Preset calllistno reaction
Brightness value or Scene-/Preset calllistno reaction
Brightness value when lighting control is activatedlist70 % (179)
Follow-up time of the inactive control in s [0...65,535]unsignedInt 0…6553560
Channel A is no masterlistyes
Restore factor for daylight compensation during Downloadlistyes
Step time for slow approachlist4 s
Step time for slow approachlist1 s

Version history

ApplicationApp noFingerprintFirst seenSizeFile
Control Dim 2f 1-10V/1.2a 1.2 latest$A049BCE42026-11-25218 KBDownload

About this file

This is the official ETS product database for the ABB AG - BUSCH-JAEGER 6197/70 Light Controller, 2fold, 1-10V, 16A, MDRC (6197/70), published by the manufacturer in the KNX online catalog. To use it, open ETS, go to Catalogs → Import and choose the downloaded .knxprod file. The device then appears in your catalog and can be added to a project. Older versions are kept so existing projects can be matched to the application program they were commissioned with.