6144/40 4f-Year Time Switch,MDRC 6144/40
ABB AG - BUSCH-JAEGER · Order number 6144/40 · Time Switch › Timer
Download .knxprod Switch Value Time Date Logic/1.5 1.5 · 102 KB
Product
| Manufacturer | ABB AG - BUSCH-JAEGER |
|---|---|
| Product name | 6144/40 4f-Year Time Switch,MDRC |
| Order number | 6144/40 |
| Hardware | 6144/40 4v-Jaarklok,DIN-rail |
| Medium | Twisted Pair |
| Rail mounted | Yes |
| Registration | Certified |
| Languages | de-DE, en-US, nl-NL |
| Catalog entry | M-0007_H-2-1-O00FC_HP-FF11-15-9201-O00FC_CI-6144.2F40-1 |
| Fingerprint | 9201 |
| SHA-256 | a88269f8d396e480021c592f8f24a636d3c7ae8466a55a7a3ad0115a41959fb4 |
| First seen | 2026-11-25 |
| Markets | Australia, Austria, Belgium, Germany, Netherlands |
Application program: Switch Value Time Date Logic/1.5 1.5
| Application number | $FF11 |
|---|---|
| Version | 1.5 |
| Mask version | MV-0705 (7.5) |
| KNX Data Secure | No |
| Minimum ETS version | 3.0d |
| Parameters | 233 |
| Group objects | 131 |
Group objects (131)
| No | Name | Function | Size | DPT | Flags |
|---|---|---|---|---|---|
| 0 | Date | Receive/Send | 3 Bytes | 11.1 date | CT |
| 0 | Date | Receive/Send | 3 Bytes | 11.1 date | CW |
| 1 | Time | Receive/Send | 3 Bytes | 10.1 time of day | CT |
| 1 | Time | Receive/Send | 3 Bytes | 10.1 time of day | CW |
| 3 | Request date/time | Receive | 1 Bit | CW | |
| 4 | Switch channel A | Send | 1 Bit | 1.1 switch | CT |
| 5 | Switch channel B | Send | 1 Bit | 1.1 switch | CT |
| 6 | Switch channel C | Send | 1 Bit | 1.1 switch | CT |
| 7 | Switch channel D | Send | 1 Bit | 1.1 switch | CT |
| 8 | Priority channel A | Send | 2 Bit | 2.1 switch control | CT |
| 9 | Priority channel B | Send | 2 Bit | 2.1 switch control | CT |
| 10 | Priority channel C | Send | 2 Bit | 2.1 switch control | CT |
| 11 | Priority channel D | Send | 2 Bit | 2.1 switch control | CT |
| 12 | Integer 1 byte channel A | Send | 1 Byte | 5.10 counter pulses (0..255) | CT |
| 13 | Integer 1 byte channel B | Send | 1 Byte | 5.10 counter pulses (0..255) | CT |
| 14 | Integer 1 byte channel C | Send | 1 Byte | 5.10 counter pulses (0..255) | CT |
| 15 | Integer 1 byte channel D | Send | 1 Byte | 5.10 counter pulses (0..255) | CT |
| 16 | Integer 2 byte channel A | Send | 2 Bytes | 7.1 pulses | CT |
| 17 | Integer 2 byte channel B | Send | 2 Bytes | 7.1 pulses | CT |
| 18 | Integer 2 byte channel C | Send | 2 Bytes | 7.1 pulses | CT |
| 19 | Integer 2 byte channel D | Send | 2 Bytes | 7.1 pulses | CT |
| 20 | Float 2 byte channel A | Send | 2 Bytes | CT | |
| 21 | Float 2 byte channel B | Send | 2 Bytes | CT | |
| 22 | Float 2 byte channel C | Send | 2 Bytes | CT | |
| 23 | Float 2 byte channel D | Send | 2 Bytes | CT | |
| 24 | Float 4 byte channel A | Send | 4 Bytes | CT | |
| 25 | Float 4 byte channel B | Send | 4 Bytes | CT | |
| 26 | Float 4 byte channel C | Send | 4 Bytes | CT | |
| 27 | Float 4 byte channel D | Send | 4 Bytes | CT | |
| 28 | Scene channel A | Send | 1 Byte | CT | |
| 29 | Scene channel B | Send | 1 Byte | CT | |
| 30 | Scene channel C | Send | 1 Byte | CT | |
| 31 | Scene channel D | Send | 1 Byte | CT | |
| 32 | HVAC channel A | Send | 1 Byte | CT | |
| 33 | HVAC channel B | Send | 1 Byte | CT | |
| 34 | HVAC channel C | Send | 1 Byte | CT | |
| 35 | HVAC channel D | Send | 1 Byte | CT | |
| 36 | Priority value channel A off | Receive | 1 Bit | 1.3 enable | CW |
| 37 | Priority value channel A on | Receive | 1 Bit | 1.3 enable | CW |
| 38 | Priority value channel B off | Receive | 1 Bit | 1.3 enable | CW |
| 39 | Priority value channel B on | Receive | 1 Bit | 1.3 enable | CW |
| 40 | Priority value channel C off | Receive | 1 Bit | 1.3 enable | CW |
| 41 | Priority value channel C on | Receive | 1 Bit | 1.3 enable | CW |
| 42 | Priority value channel D off | Receive | 1 Bit | 1.3 enable | CW |
| 43 | Priority value channel D on | Receive | 1 Bit | 1.3 enable | CW |
| 44 | Integer value 1 byte channel A off | Receive | 1 Byte | 5.10 counter pulses (0..255) | CW |
| 45 | Integer value 1 byte channel A on | Receive | 1 Byte | 5.10 counter pulses (0..255) | CW |
| 46 | Integer value 1 byte channel B off | Receive | 1 Byte | 5.10 counter pulses (0..255) | CW |
| 47 | Integer value 1 byte channel B on | Receive | 1 Byte | 5.10 counter pulses (0..255) | CW |
| 48 | Integer value 1 byte channel C off | Receive | 1 Byte | 5.10 counter pulses (0..255) | CW |
| 49 | Integer value 1 byte channel C on | Receive | 1 Byte | 5.10 counter pulses (0..255) | CW |
| 50 | Integer value 1 byte channel D off | Receive | 1 Byte | 5.10 counter pulses (0..255) | CW |
| 51 | Integer value 1 byte channel D on | Receive | 1 Byte | 5.10 counter pulses (0..255) | CW |
| 52 | Integer value 2 byte channel A off | Receive | 2 Bytes | 7.1 pulses | CW |
| 53 | Integer value 2 byte channel A on | Receive | 2 Bytes | 7.1 pulses | CW |
| 54 | Integer value 2 byte channel B off | Receive | 2 Bytes | 7.1 pulses | CW |
| 55 | Integer value 2 byte channel B on | Receive | 2 Bytes | 7.1 pulses | CW |
| 56 | Integer value 2 byte channel C off | Receive | 2 Bytes | 7.1 pulses | CW |
| 57 | Integer value 2 byte channel C on | Receive | 2 Bytes | 7.1 pulses | CW |
| 58 | Integer value 2 byte channel D off | Receive | 2 Bytes | 7.1 pulses | CW |
| 59 | Integer value 2 byte channel D on | Receive | 2 Bytes | 7.1 pulses | CW |
| 60 | Float value 2 byte channel A off | Receive | 2 Bytes | CW | |
| 61 | Float value 2 byte channel A on | Receive | 2 Bytes | CW | |
| 62 | Float value 2 byte channel B off | Receive | 2 Bytes | CW | |
| 63 | Float value 2 byte channel B on | Receive | 2 Bytes | CW | |
| 64 | Float value 2 byte channel C off | Receive | 2 Bytes | CW | |
| 65 | Float value 2 byte channel C on | Receive | 2 Bytes | CW | |
| 66 | Float value 2 byte channel D off | Receive | 2 Bytes | CW | |
| 67 | Float value 2 byte channel D on | Receive | 2 Bytes | CW | |
| 68 | Float value 4 byte channel A off | Receive | 4 Bytes | CW | |
| 69 | Float value 4 byte channel A on | Receive | 4 Bytes | CW | |
| 70 | Float value 4 byte channel B off | Receive | 4 Bytes | CW | |
| 71 | Float value 4 byte channel B on | Receive | 4 Bytes | CW | |
| 72 | Float value 4 byte channel C off | Receive | 4 Bytes | CW | |
| 73 | Float value 4 byte channel C on | Receive | 4 Bytes | CW | |
| 74 | Float value 4 byte channel D off | Receive | 4 Bytes | CW | |
| 75 | Float value 4 byte channel D on | Receive | 4 Bytes | CW | |
| 76 | Scene value channel A off | Receive | 1 Byte | CW | |
| 77 | Scene value channel A on | Receive | 1 Byte | CW | |
| 78 | Scene value channel B off | Receive | 1 Byte | CW | |
| 79 | Scene value channel B on | Receive | 1 Byte | CW | |
| 80 | Scene value channel C off | Receive | 1 Byte | CW | |
| 81 | Scene value channel C on | Receive | 1 Byte | CW | |
| 82 | Scene value channel D off | Receive | 1 Byte | CW | |
| 83 | Scene value channel D on | Receive | 1 Byte | CW | |
| 84 | Value HVAC channel A off | Receive | 1 Byte | CW | |
| 85 | Value HVAC channel A on | Receive | 1 Byte | CW | |
| 86 | Value HVAC channel B off | Receive | 1 Byte | CW | |
| 87 | Value HVAC channel B on | Receive | 1 Byte | CW | |
| 88 | Value HVAC channel C off | Receive | 1 Byte | CW | |
| 89 | Value HVAC channel C on | Receive | 1 Byte | CW | |
| 90 | Value HVAC channel D off | Receive | 1 Byte | CW | |
| 91 | Value HVAC channel D on | Receive | 1 Byte | CW | |
| 92 | Logic gate 1 communication object I | Receive | 1 Bit | 1.1 switch | CW |
| 93 | Logic gate 1 communication object II | Receive | 1 Bit | 1.1 switch | CW |
| 94 | Logic gate 1 communication object III | Receive | 1 Bit | 1.1 switch | CW |
| 95 | Logic gate 1 communication object IV | Receive | 1 Bit | 1.1 switch | CW |
| 96 | Logic gate 1 output value bit | Send | 1 Bit | 1.1 switch | CT |
| 98 | Logic gate 1 output value byte | Send | 1 Byte | 5.10 counter pulses (0..255) | CT |
| 100 | Logic gate 2 communication object I | Receive | 1 Bit | 1.1 switch | CW |
| 101 | Logic gate 2 communication object II | Receive | 1 Bit | 1.1 switch | CW |
| 102 | Logic gate 2 communication object III | Receive | 1 Bit | 1.1 switch | CW |
| 103 | Logic gate 2 communication object IV | Receive | 1 Bit | 1.1 switch | CW |
| 104 | Logic gate 2 output value bit | Send | 1 Bit | 1.1 switch | CT |
| 106 | Logic gate 2 output value byte | Send | 1 Byte | 5.10 counter pulses (0..255) | CT |
| 108 | Logic gate 3 communication object I | Receive | 1 Bit | 1.1 switch | CW |
| 109 | Logic gate 3 communication object II | Receive | 1 Bit | 1.1 switch | CW |
| 110 | Logic gate 3 communication object III | Receive | 1 Bit | 1.1 switch | CW |
| 111 | Logic gate 3 communication object IV | Receive | 1 Bit | 1.1 switch | CW |
| 112 | Logic gate 3 output value bit | Send | 1 Bit | 1.1 switch | CT |
| 114 | Logic gate 3 output value byte | Send | 1 Byte | 5.10 counter pulses (0..255) | CT |
| 116 | Logic gate 4 communication object I | Receive | 1 Bit | 1.1 switch | CW |
| 117 | Logic gate 4 communication object II | Receive | 1 Bit | 1.1 switch | CW |
| 118 | Logic gate 4 communication object III | Receive | 1 Bit | 1.1 switch | CW |
| 119 | Logic gate 4 communication object IV | Receive | 1 Bit | 1.1 switch | CW |
| 120 | Logic gate 4 output value bit | Send | 1 Bit | 1.1 switch | CT |
| 122 | Logic gate 4 output value byte | Send | 1 Byte | 5.10 counter pulses (0..255) | CT |
| 124 | DST announcement | Send | 1 Bit | 1.2 boolean | CT |
| 125 | State time receiver | Send | 1 Bit | CT | |
| 126 | Percent Channel A | Send | 1 Byte | 5.1 percentage (0..100%) | CT |
| 127 | Percent Channel B | Send | 1 Byte | 5.1 percentage (0..100%) | CT |
| 128 | Percent Channel C | Send | 1 Byte | 5.1 percentage (0..100%) | CT |
| 129 | Percent Channel D | Send | 1 Byte | 5.1 percentage (0..100%) | CT |
| 130 | Value Percent Channel A Off | Receive | 1 Byte | 5.1 percentage (0..100%) | CW |
| 131 | Value Percent Channel A On | Receive | 1 Byte | 5.1 percentage (0..100%) | CW |
| 132 | Value Percent Channel B Off | Receive | 1 Byte | 5.1 percentage (0..100%) | CW |
| 133 | Value Percent Channel B On | Receive | 1 Byte | 5.1 percentage (0..100%) | CW |
| 134 | Value Percent Channel C Off | Receive | 1 Byte | 5.1 percentage (0..100%) | CW |
| 135 | Value Percent Channel C On | Receive | 1 Byte | 5.1 percentage (0..100%) | CW |
| 136 | Value Percent Channel D Off | Receive | 1 Byte | 5.1 percentage (0..100%) | CW |
| 137 | Value Percent Channel D On | Receive | 1 Byte | 5.1 percentage (0..100%) | CW |
Parameters (138)
| Parameter | Type | Default |
|---|---|---|
| Percent Channel A Off | unsignedInt 0…255 | 0 |
| Percent Channel A On | unsignedInt 0…255 | 0 |
| Function channel A | list | none |
| Logik Gatter 1 Ausgabewert | unsignedInt 0…255 | 0 |
| Logik Gatter 1 Funktion | unsignedInt 0…255 | 0 |
| Priority channel A on | list | No priority |
| Priority channel A off | list | No priority |
| Prio Values Eeprom | unsignedInt 0…255 | 0 |
| Percent Channel B Off | unsignedInt 0…255 | 0 |
| Value channel A on | unsignedInt 0…255 | 0 |
| Value channel A off | unsignedInt 0…255 | 0 |
| Percent Channel B On | unsignedInt 0…255 | 0 |
| Percent Channel C Off | unsignedInt 0…255 | 0 |
| Value channel A on | unsignedInt 0…65535 | 0 |
| Value channel A off | unsignedInt 0…65535 | 0 |
| btnValFloat2_0_0 | unsignedInt 0…255 | 0 |
| 2 byte float channel A on | text | 0 |
| 2 byte float channel A off | text | 0 |
| btnValFloat2_1_0_lb | unsignedInt 0…255 | 0 |
| btnValFloat2_1_0_hb | unsignedInt 0…255 | 0 |
| 4 byte float channel A on | text | 0 |
| 4 byte float channel A off | text | 0 |
| Scene channel A on | unsignedInt 1…64 | 1 |
| Scene channel A off | unsignedInt 1…64 | 1 |
| HVAC channel A on | list | Auto |
| HVAC channel A off | list | Auto |
| Percent Channel A On | unsignedInt 0…100 | 0 |
| Percent Channel A Off | unsignedInt 0…100 | 0 |
| Percent Channel C On | unsignedInt 0…255 | 0 |
| Percent Channel D Off | unsignedInt 0…255 | 0 |
| Random function channel A | list | none |
| Shortest delay channel A [minutes] | unsignedInt 0…254 | 0 |
| Longest delay channel A [minutes] | unsignedInt 1…255 | 1 |
| Percent Channel D On | unsignedInt 0…255 | 0 |
| Function channel B | list | none |
| Priority channel B on | list | No priority |
| Zufallsfunktion wählen | unsignedInt 0…255 | 0 |
| Priority channel B off | list | No priority |
| Value channel B on | unsignedInt 0…255 | 0 |
| ParamNumberFloat_0 | unsignedInt 0…255 | 0 |
| ParamNumberFloat_1 | unsignedInt 0…255 | 0 |
| Value channel B off | unsignedInt 0…255 | 0 |
| Value channel B on | unsignedInt 0…65535 | 0 |
| ParamNumberFloat_2 | unsignedInt 0…255 | 0 |
| ParamNumberFloat_3 | unsignedInt 0…255 | 0 |
| Value channel B off | unsignedInt 0…65535 | 0 |
| 2 byte float channel B on | text | 0 |
| 2 byte float channel B off | text | 0 |
| 4 byte float channel B on | text | 0 |
| 4 byte float channel B off | text | 0 |
| Scene channel B on | unsignedInt 1…64 | 1 |
| Scene channel B off | unsignedInt 1…64 | 1 |
| HVAC channel B on | list | Auto |
| HVAC channel B off | list | Auto |
| Percent Channel B On | unsignedInt 0…100 | 0 |
| Percent Channel B Off | unsignedInt 0…100 | 0 |
| Random function channel B | list | none |
| Shortest delay channel B [minutes] | unsignedInt 0…254 | 0 |
| Longest delay channel B [minutes] | unsignedInt 1…255 | 1 |
| Function channel C | list | none |
| Priority channel C on | list | No priority |
| Priority channel C off | list | No priority |
| Value channel C on | unsignedInt 0…255 | 0 |
| Value channel C off | unsignedInt 0…255 | 0 |
| Value channel C on | unsignedInt 0…65535 | 0 |
| Value channel C off | unsignedInt 0…65535 | 0 |
| 2 byte float channel C on | text | 0 |
| 2 byte float channel C off | text | 0 |
| 4 byte float channel C on | text | 0 |
| 4 byte float channel C off | text | 0 |
| Scene channel C on | unsignedInt 1…64 | 1 |
| Scene channel C off | unsignedInt 1…64 | 1 |
| Kanal A Funktionen | unsignedInt 0…255 | 0 |
| Kanal B Funktionen | unsignedInt 0…255 | 0 |
| HVAC channel C on | list | Auto |
| HVAC channel C off | list | Auto |
| Kanal C Funktionen | unsignedInt 0…255 | 0 |
| Kanal D Funktionen | unsignedInt 0…255 | 0 |
| Percent Channel C On | unsignedInt 0…100 | 0 |
| Percent Channel C Off | unsignedInt 0…100 | 0 |
| Logikgatter 2 Funktion | unsignedInt 0…255 | 0 |
| Logikgatter 2 Ausgang | unsignedInt 0…255 | 0 |
| Random function channel C | list | none |
| Shortest delay channel C [minutes] | unsignedInt 0…254 | 0 |
| Logikgatter 3 Funktion | unsignedInt 0…255 | 0 |
| Logikgatter 3 Ausgang | unsignedInt 0…255 | 0 |
| Longest delay channel C [minutes] | unsignedInt 1…255 | 1 |
| Logik Gatter 4 Funktion | unsignedInt 0…255 | 0 |
| Logik Gatter 4 Ausgang | unsignedInt 0…255 | 0 |
| Function channel D | list | none |
| Priority channel D on | list | No priority |
| Priority channel D off | list | No priority |
| Value channel D on | unsignedInt 0…255 | 0 |
| Value channel D off | unsignedInt 0…255 | 0 |
| Value channel D on | unsignedInt 0…65535 | 0 |
| Value channel D off | unsignedInt 0…65535 | 0 |
| 2 byte float channel D on | text | 0 |
| 2 byte float channel D off | text | 0 |
| 4 byte float channel D on | text | 0 |
| 4 byte float channel D off | text | 0 |
| Scene channel D on | unsignedInt 1…64 | 1 |
| Scene channel D off | unsignedInt 1…64 | 1 |
| HVAC channel D on | list | Auto |
| HVAC channel D off | list | Auto |
| Percent Channel D On | unsignedInt 0…100 | 0 |
| Percent Channel D Off | unsignedInt 0…100 | 0 |
| Random function channel D | list | none |
| Shortest delay channel D [minutes] | unsignedInt 0…254 | 0 |
| Longest delay channel D [minutes] | unsignedInt 1…255 | 1 |
| Logic gate 1 | list | inactive |
| Logic function | list | And |
| Input value 1 [bit] | list | unused |
| Input value 2 [bit] | list | unused |
| Input value 3 [bit] | list | unused |
| Input value 4 [bit] | list | unused |
| Output value bit | list | inactive |
| Output value byte | list | inactive |
| Value byte on | unsignedInt 0…255 | 0 |
| Value byte off | unsignedInt 0…255 | 0 |
| ParameterLogic1Input | unsignedInt 0…255 | 4 |
| Extended logic function | list | inactive |
| Input value 1 inverted | list | no |
| Input value 2 inverted | list | no |
| Input value 3 inverted | list | no |
| Input value 4 inverted | list | no |
| Output value inverted | list | no |
| Logic gate 2 | list | inactive |
| ParameterLogic2Input | unsignedInt 0…255 | 4 |
| Logic gate 3 | list | inactive |
| ParameterLogic3Input | unsignedInt 0…255 | 4 |
| Logic gate 4 | list | inactive |
| ParameterLogic4Input | unsignedInt 0…255 | 4 |
| PID_HardwareType | list | PID_HardwareType |
| Send or receive date/time | list | send date/time to bus |
| How to send date and time | list | never |
| Cycle interval for date and time | list | at 00:02 am and change of DST |
| How to send time receiver state | list | never |
| Cycle interval for time receiver state | list | every 6 hours |
Version history
| Application | App no | Fingerprint | First seen | Size | File |
|---|---|---|---|---|---|
| Switch Value Time Date Logic/1.5 1.5 latest | $FF11 | 9201 | 2026-11-25 | 102 KB | Download |
About this file
This is the official ETS product database for the ABB AG - BUSCH-JAEGER 6144/40 4f-Year Time Switch,MDRC (6144/40), published by the manufacturer in the KNX online catalog. To use it, open ETS, go to Catalogs → Import and choose the downloaded .knxprod file. The device then appears in your catalog and can be added to a project. Older versions are kept so existing projects can be matched to the application program they were commissioned with.
More from ABB AG - BUSCH-JAEGER
- 6145/10 Zeitsender DCF, REG 6145/10
- IPS/S3.5.11 IP Interface Secure,MDRC 2CDG 110 204 R0021
- FCC/S1.1.2.11 Fan Coil Controller,PWM,3-speed,manual operation,MDRC 2CDG 110 211 R0021
- FCC/S1.2.2.11 Fan Coil Controller,0-10V,3-speed,manual operation,MDRC 2CDG 110 213 R0021
- FCC/S1.3.2.11 Fan Coil Controller,0-10V,0-10V,manual operation,MDRC 2CDG 110 215 R0021
- VC/S4.1.11 Valve Drive Controller,4-fold,MDRC 2CDG 110 216 R0021
- VC/S4.2.11 Valve Drive Controller,manual operation,4-fold,MDRC 2CDG 110 217 R0021
- FCC/S1.5.2.11 Fan Coil Controller,PWM,0-10V,manual operation,MDRC 2CDG 110 235 R0021
- SAH/S8.10.7.11 Switch/Shutter Act, 8-f, 10A, MDRC 2CDG 110 247 R0021
- SAH/S16.10.7.11 Switch/Shutter Act, 16-f, 10A, MDRC 2CDG 110 248 R0021
- SAH/S24.10.7.11 Switch/Shutter Act, 24-f, 10A, MDRC 2CDG 110 249 R0021
- SAH/S8.16.7.11 Switch/Shutter Act, 8-f, 16A, MDRC 2CDG 110 250 R0021